PRASA S MISSION CRITICAL SERVICES UPS & ATS AMC BATTERY & INVERTER AMC DATA CENTERS AMC GRID-TO-CHIP MAINTENANCE FIRE DETECTION AMC DATA CENTER AMC

Similar documents
SECTION AUTOMATIC TRANSFER SWITCHES

Spectron LSN (Life Safety Network) Suggested Specifications

Standard PRC Protection System and Automatic Reclosing Maintenance. Standard Development Roadmap

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

SECTION POWER SUPPLIES AND DISTRIBUTION

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Property risk solutions

NERC PRC Compliance Guide

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SECTION AUTOMATIC TRANSFER SWITCHES

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

Maintenance Best Practices & Intervals for Substation Equipment. Presented by: Paul Schlies, President/CEO Energis High Voltage Services, Inc.

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Electrical Safety Compliance: NFPA 70E

Advantage Services Capabilities

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Standard Development Roadmap

A WORLD WITHOUT DOWNTIME

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION ENCLOSED CONTROLLERS

ASCO PowerQuest Power Monitoring and Control Systems

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

B. Section Transfer Switches: Automatic transfer switch.

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

DISTRIBUTION OPERATIONS AND MAINTENANCE

Workflow Performance Assurance

Electrical Preventive Maintenance (EPM) Program

Semiconductor Solutions. Your global source for industrial automation, control, and power distribution products and services

Your specialist partner for total electrical compliance. Electrical Testing

PROFILE. industrial services rental trading

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

CHAPTER 20 SERVICE EQUIPMENT

Healthcare Electrical Reference Architecture for Large Hospitals in North America

A. This Section includes transfer switches rated 600 V and less, including the following:

COMPANY OVERVIEW MISSION: THE PURPOSE OF OUR BUSINESS IS TO PROVIDE CONTINUITY OF ELECTRICAL POWER TO KEEP BUSINESSES IN BUSINESS.

An ISO 9001 Certified Company SAFE INDIA HI-TECH SYSTEMS LLP. Company Profile

Security CCTV System Construction Checklist

June 4, 2014 VIA ELECTRONIC FILING. Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C.

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Standard PRC-005-3(i) Protection System and Automatic Reclosing Maintenance

ASCO PowerQuest Critical Power Management System

R S Enterprises.

Dependable Solutions for Gas Detection

Heat Exchanger Excellence DESIGN BUILD SUPPLY INSTALL MAINTAIN.

infrared inspections efficient solutions. focused results.

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Preliminary Operations and Maintenance Plan Baron Winds Project

SEL Arc-Flash Solutions

CONTENTS AUTOMATIC TRANSFER SWITCHES

Liebert PPC Second Generation Power Distribution Cabinet

SECTION SECURITY TESTING AND COMMISSIONING

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Standard PRC-005-3(X) Protection System and Automatic Reclosing Maintenance

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

SEL Arc-Flash Solutions

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

Batt-Safe Battery String Monitoring System

Improving Productivity, Quality and Security

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

SPM Flex Chemcassette Tape-Based Gas Detector

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

SECTION GAS-FIRED RADIANT HEATERS

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

4. Applicability: 4.1. Functional Entities: 4.2. Facilities:

Energy Commander Paralleling Switchgear

Standard PRC-005-4(X) Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

G- CORP SOLUTION. (SAFETY.CONSULTANCY.MANAGEMENT) ISO 9001 :2015 Certified.

C. B. Trading Corporation

*************************************************************************** SECTION D50 ELECTRICAL 02/18

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

CLIMATE SEPARATION SOLUTION. SensAir

Your partner for maintenance of electrical systems. We take care of it.

Today s world has more risk than ever. Today s G4S has more ways to protect you.

Life Sciences Solutions. Better Solutions. Faster Results.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Installation Instructions

Every day is filled with decisions let us simplify your day with our technical solutions

APC BC300 Series 40kW 208/450/480V User Guide

Balance of Plant Maintenance

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Em-powering the nation!!!

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Transcription:

PRASA S MISSION CRITICAL SERVICES UPS & ATS AMC BATTERY & INVERTER AMC DATA CENTERS AMC GRID-TO-CHIP MAINTENANCE FIRE DETECTION AMC DATA CENTER AMC

Downtime Is Not An Option The industrial uninterruptible power supply (UPS) is the foundation of your emergency power system. Unlike the commercial UPS designed to protect critical IT loads, the industrial UPS protects critical processes, control systems and fire/life safety systems. For applications such as oil and gas, petrochemical and power generation plants, when the power is interrupted, it can cause dangerous chemical process instability, damage to process equipment, or in some cases, the complete shutdown of the facility costing millions in lost production, damaged equipment, and loss of production time. when so much at stake, it s important to protect your emergency power system by performing routine preventive maintenance ensuring maximum reliability of the backup system including the UPS, batteries, chargers, inverters and static switches, electrical filters etc. Ensure the Continuous Operation of Your Facility Services for UPS, Batteries, power, Static Switches & Data Centers. Every emergency power system contains life-limited components that must be maintained according to the manufacturer s specifications. To maximize the life of these components, regular maintenance is critical. An effective preventive maintenance strategy can be one of the most cost-effective measures you can take to ensure the continuous power to both your critical processes and your entire plant. PRASA s Electrical Reliability Services is an authorized Emerson service provider with access to their OEM parts, technical support and design engineering resources. With this expertise, PRASA can provide solutions for Chloride, Custom Power, and any other manufacturer s emergency power system. PRASA offers a wide variety of services to ensure these systems are performing properly and will support the critical load when power is interrupted. Whether you need startup support, routine maintenance or emergency response, we have the personnel and the technical expertise to support your service needs. Startup and Commissioning Services Maintenance & Testing Services Life-Extension Services Battery Replacements Emergency Services

UPS Maintenance We ll test your UPS systems safety functions, control function, batteries and connections to ensure proper operation. This includes a visual and mechanical inspection, thermographic scan, electrical and mechanical interlock systems tests, alarm history review, insulation resistance tests, electronics calibration, verification of alarm circuits and indicators, replacement of life-limited components as required, static transfer tests, battery operation and return test, load balancing evaluation, phase rotation and site wiring checks. Battery Maintenance In the event of a power outage, a single bad cell in a string of batteries could compromise your entire backup system and leave you without protection. Frequent battery inspections identify weak or failing batteries. Timely assessments of the cell and string state of health helps identify when batteries need replaced to ensure system reliability. PRASA s technicians and engineers can design a maintenance plan based around tests and procedures that meet the requirements of NETA, IEEE, and/or NERC depending on your application. Start-up and Commissioning Services New equipment installations require startup and commissioning to ensure your emergency power system has been correctly installed and configured and will perform as designed. PRASA s highly qualified personnel will conduct testing to verify the system operates as an integrated system and will support the critical load during power interruptions. All testing is conducted in accordance with the manufacturer s and NETA s testing specifications. This includes the following tests: Visual and mechanical inspection of the equipment including subassemblies, wiring harnesses, contacts, cables and major components Electrical and mechanical functional tests. Thermographic scan to check temperatures on all breakers, connections, and associated controls. (Optional) Verification of alarm circuits and indicators for static switch bypass switches Maintenance and Testing Services A regular preventive maintenance program from PRASA ensures maximum reliability of your equipment by providing systematic inspections, detection, and correction of incipient failures before they develop into major defects that could translate into costly downtime. Our trained technicians understand the critical nature of working on your emergency power system. All testing will be performed based on the maintenance recommendations from NETA and NFPA for UPS, batteries, inverters, and associated components. PRASA will also ensure compliance with IEEE standards.

UPS Maintenance PRASA technicians will also inspect and verify the UPS features and functionality including proper operation; input/output voltage and currents; system alignment; and verification of DC bus voltage and ripple on the battery plant. Emergency Power System Recommended Maintenance The Electric Power Research Institute (EPRI) estimates the national cost of power interruptions is approximately $80 billion per year to U.S. electrical customers, with momentary interruptions accounting for two-thirds of the total cost. Studies have also shown that nearly 67 percent of all load losses are preventable. Because companies rely on their emergency power system to deliver continuous power without any disruption to their business, a maintenance program, similar to the one outlined below, is critical to ensure that your emergency power system minimizes your risk of downtime. Battery Maintenance PRASA ensure that the battery maintain the appropriate level of charge. Periodic UPS Systems Data Centres maintenance should verify proper operation and examine interconnection cables, cell connectors, and other conductors for wear, contamination, corrosion and discolorations. Racks should be checked for corrosion, cleanliness and structural integrity. Conduct visual and mechanical inspection Perform functional testing Thermographic scan of breakers, connections Perform electrical and mechanical interlock systems tests 1 Month 2 Months UPS Preventive Maintenance Precision Air Conditioner Maintenance Fire Detection Preventive Maintenance WLD Maintenance 3 Month Parts Availability Our field service technicians adhere to recommended parts replacement cycles and have access to local OEM spare parts inventory to perform corrective maintenance Review alarm history inspect filters and vents Measure voltage readings for input/output and bypass; measure power supply levels and harmonic currents Calibrate electronics to system specifications VESDA Nozzel Clean-up & Maintenance Rodent Repellent Transducer check-up & Services CCTV Camera Lens Clean-up & Preventive Maintenance as required. Technicians can also provide spare part recommendations to reduce downtime should a failure occur. Verify alarm circuits and indicators for static witch and bypass switches Replace life-limited components as required Test static transfer from invert to bypass and back Verify battery operation and return tests to UPS, generator, and ATS functions Evaluate load balancing Access Control Functional Test & report generation BMS Transducer Maintenance Electrical switchgear check-up & Short Circuit check-up Services DG Set Preventive Maintenance (Excluding Oil Change) 2 Months Check phase rotation and site wiring

Batteries Auto Transfer Switch Conduct visual and mechanical inspection 3 Month Perform functional testing 2 Month Perform battery resistance testing Inspect physical and mechanical condition Record float and supply voltage measurements Inspect electrolytes Record specific gravity readings Test battery bank capacity including load testing with individual cell monitoring Static Switches Inspect and verify operation and system alignment As Per Manufacturer Specification 3 Month Inspect bolted electrical connections Perform manual transfer operation Verify positive mechanical interlocking Perform insulation resistance tests, contact/ pole-resistance tests Verify setting and operation of control devices Calibrate and set all relays and timers Perform automatic transfer tests to simulate loss of normal power, return emergency power, and simulate all forms of single-phase conditions Record inverter and bypass input voltage and currents Verify correct operation and timing of relays, engine start sequence, time operation; Record output voltage and currents

RELIABILITY Ensure operational reliability with preventive maintenance Minimize risk of downtime Enhance effective life and backup time of battery SAFETY Improve worker safety Improve risk management and reduce catastrophic failures Ensure regulatory compliance BANKING LOGISTICS EDUCATION IT DATA CENTER TELECOM HOSPITAL MANUFACTURING RETAIL COST Eliminate unplanned outages and lost income as a result of downtime Reduce maintenance costs by extending time between planned outages Extend life of equipment

Experience You Can Trust For more than 20 years we have been providing electrical testing, maintenance and engineering services to more than 4,000 valued repeat customers in the industrial, chemical, power, food and beverage, life sciences, data centres, education, BFI, Corporate, Transport, Communication, IT, healthcare industries etc. Take a look at our proven track record and discover how we can help & ensure your success. Your Accredited Partner As a full charter member of the Inter-National Electrical Testing Association (NETA), you are assured that the people working on your equipment are trained and qualified. And, as an active participant in the national standards organizations such as the National Fire Protection Association (NFPA), National Electrical Code (NEC), and the Institute of Electrical and Electronics Engineers (IEEE), you know that all test and inspection procedures are done in accordance with industry and regulatory standards. When and Where You Need Us With strategically located service locations across the INDIA and the largest national service workforce comprised of professional engineers, electrical engineers, and certified field technicians, you are assured that we can respond when and where you need us. Comprehensive Service & Support Whether you need startup support, routine maintenance or emergency service, you can count on Us along with Emerson to deliver complete life cycle service and support for all your electrical assets. we ll ensure your equipment operates within factory specifications ensuring continuous power to all your critical operations for years to come. We Abide by: PRASA INFOCOM & POWER SOLUTIONS P. LTD. PUNE OFFICE : 001, CASABLANCA, SANGAM PRESS ROAD, KOTHRUD, PUNE 411 038 (INDIA) PH: (020) 25434958/25446690 FAX: (020) 25468388 E-MAIL: business@prasa-pl.com URL: www.prasa-pl.com MUMBAI OFFICE : 101, Balaji CHS Ltd, Plot No.34&35, Near Petrol Pump, Sector No.5, Airoli, Navi Mumbai 400 708. PH: (022) 27793070 KOLHAPUR OFFICE : "ADINATH" 9th 'A' Road, Opp. Shirol Sangh, Jaysingpur, Dist. Kolhapur - 416101(INDIA) PH: (02322) 227639 FAX: (02322) 227639 PUNE MUMBAI KOLHAPUR

PARTIAL CLIENT LIST: AIR INDIA BAJAJ AUTO LIMITED BAJAJ ORGANICS LIMITED BAJAJ AUTO FINNCE LIMITED FINOLEX CABLES LIMITED FINOLEX INDUSTRIES LIMITED LG ELECTRONICS LUPIN PHAMRA TIMES OF INDIA LIMITED BHARAT PETROLEUM CORPORATION LIMITED TATA MOTORS LIMITED TATA INTERNATIONAL LMITED TATA CONSULTANCY SERVICES SWOROSKI AKER KVAERNER POWER GAS P. LIMITED IDEAL ROAD BUILDERS JEHANGIR HOSPITAL DEENANATH MANGESHKAR HOSPITAL SAHYANDRI HOSPITAL CUMMINS COLLEGE OF ENGINEERING CANARA BANK DENA BANK CENTRAL BANK OF INDIA IDBI BANK IDIBI HOME FINANCE PUNE DISTRICT CENTRAL CO-OP BANK SATARA DISTRICT CENTRAL CO-OP BANK KOTAK MAHINDRA BANK RAJGURUNAGAR CO-OP BANK RAJARAMBAPU CO-OP BANK VARNA SAHAKARI CO-OP BANK SANGLI URBAN CO-OP BANK KARAD URBAN CO-OP BANK THANE JANATA SAHAKARI CO-OP BANK MAHARASHTRA STATE CO-OP BANK MAX NEWYORK LIFE INSURANCE SYNYGY INDIA P. LIMITED SIGMA SOFTWARE P. LIMITED VERAZ NETWORKS NIIT NATIONAL CHEMICAL LABORATORY NATIONAL CENTER FOR CELL SCIENCES NATIONAL CENTER FOR RADIOLOGY & ASTROPHYSICS NATIONAL RESEARCH CENTER FOR GRAPES NATIONAL RESEARCH CENTER FOR ONION & GARLIC HIGH ENERGY MATERIAL RESEARCH LABS IUCCA INDIAN INSTITUTE OF SCIENCE EDUCATION & RESEARCH GE FANUC VA TECH WABAG LIMITED TETRA PAK INDIA P. LIMITED ROCKWELL AUTOMATION FORBES MARSHALL KHRONE MARSHALL KSB PUMPS BOSCH CHASSIS MAHICO SEEDS KIROLSKAR EB HENKEL ADHESIVES TECH INDIA P. LIMITED