Concealed ceiling unit with medium ESP

Similar documents
Fully Flat Cassette Design & Genius in one

Concealed ceiling units

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

VRV IV i-series heat pump

Air Conditioners. Technical Data FBQ-C

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Sky Air. Product catalogue 2017 for professionals. Get ahead of the competition R-32 IS AN INDUSTRY REVOLUTION. BE PART OF IT.

VRV IV S-series heat pump

technical data air conditioning systems Indoor Units FBQ-C7VEB

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology. Our mission Achieve the lowest environmental impact

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

technical data air conditioning systems Indoor Units FCQ-C8VEB

VRV IV heat recovery Best efficiency and comfort solution

Replacement VRV Quick & quality replacement for R-22 and R-407C systems

Sky Air. Product catalogue for installers Your business is our concern

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioners Heating & Cooling

Daikin leads the way:

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Water cooled VRV IV W-series

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioner SVC MANUAL(Exploded View)

Air conditioners Heating & Cooling

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioners Heating & Cooling

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Daikin air conditioners for your home, shops, restaurants and offices

Remote control infrared ARC433B76 ARC433A8 ARC433B69

FBQ. DC Duct Heat Pump or Cooling Only

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Air Conditioning Systems

Air Conditioners Heating & Cooling

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Infrastructure cooling solution

for small rooms in multi application

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Air Conditioners Technical Data

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

FCQH-D8 / RZQ-D3V1/D9V1

Air conditioners Cooling only

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

Air Conditioners Heating & Cooling

High temperature hydrobox for VRV

Air Conditioners Heating & Cooling

Heating & Cooling. Air conditioners. M u l t i m o d e l a p p l i c a t i o n. » SEER up to A ++ » Energy efficient heating & cooling

Ducted inverter reverse cycle air conditioning

Ventilation Product catalogue 2017 for professionals

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Just feel well. 2017/2018 Air conditioning

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Inverter Ducted Air Conditioners

where innovation meets creativity

Ventilation. Product catalogue 2019 for professionals

Air Conditioners. Technical Data RZQG-L

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Inverter Ducted Air Conditioners

Air conditioners Heating & Cooling

THE CARRIER COMFORT LINE

LV Series. SEER 15+ Concealed Built in Heat Pump

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

Samsung 360 Cassette, Single Zone, Split System

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Digital Inverter 4 series 8 & 10HP

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Heat Pump Air Conditioning Systems

Air Conditioners Heating & Cooling

VRV IV 360 efficiency

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

Prices and technical information for Sky Air products. Pricelist Sky Air A-series

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

usiness concern our SKY AIR PRODUCT RANGE COMMERCIAL CATALOGUE

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Multi Air Conditioning System for Buildings

FTQ. Daikin Inverter Ducted Heat Pump

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

Air conditioners, heating & cooling for shops,restaurants and offices

Transcription:

FXSQ-A Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market Slimmest unit in class, only 245mm (3mm built-in height) and therefore narrow ceiling voids are no longer a challenge outblow bottom suction rear suction FXSQ-A Whisper quiet operation: down to 25dBA sound pressure level Medium external static pressure up to 1Pa facilitates using flexible ducts of varying lengths Possibility to change ESP via wired remote control allows optimisation of the supply air volume Discretely concealed in the wall: only the suction and discharge grilles are visible 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc. Reduced energy consumption thanks to specially developed DC fan motor and drain pump Optional fresh air intake Flexible installation: air suction direction can be altered from rear to bottom suction and choice between free use or connection to optional suction grilles BRC1E53A-B-C BRC4C65 For free use into a false ceiling For connecting onto a suction canvas (not supplied by Daikin) For direct connection to Daikin panel (via EYBSD kit) Standard built-in drain pump with 625mm lift increases flexibility and installation speed 156

FXSQ-A Automatic Airflow Adjustment function Automatically selects the most appropriate fan curve to achieve the units nominal air flow within ±1% External static pr essure (Pa) Fan characteristic curves Why? After installation the real ducting will frequently differ from the initially calculated air flow resistance the real air flow may be much lower or higher than nominal, leading to a lack of capacity or uncomfortable air temperature Automatic Airflow Adjustment function will adapt the unit s fan speed to any ducting automatically(1 or more fan curves are available on every model), making installation much faster Duct resistance curves ± matic adjustment ) min) Indoor unit FXSQ 15A 2A 25A 32A 4A A 63A 8A A 125A 14A Cooling capacity Nom. kw 7 2 8 3.6 4.5 5.6 7.1 9. 12 14. 16. Heating capacity Nom. kw 9 5 3.2 4. 5. 6.3 8. 15 16. 18. Power input - Hz Cooling Nom. kw.41.45.92.95.121.157.214.243 Heating Nom. kw.38.42.89.92.118.154.211.24 Dimensions Unit Height mm 245 Width mm 5 7 1, 1,4 1,5 Depth mm 8 Weight Unit kg 23.5 24 28.5 29 35.5 36.5 46 47 51 Casing Colour Not painted (galvanised) Material Galvanised steel plate Fan-Air flow rate - Cooling HighNom.Low m³min 8.77.56.5 97.56.5 9.587. 151511 15.21511 21815 2319.516 322723 363526 393428 Hz Heating HighNom.Low m³min 8.77.56.5 97.56.5 9.587 151511 15.21511 211815 2319.516. 322723 363526 393428 Fan-External static HighNom. Pa pressure - Hz 13 14 1 Air filter Type Resin net with mold resistance Sound power level Cooling Nom. dba 54 55 6 59 61 64 Sound pressure level Cooling HighNom.Low dba 29.52825 32825 312926 353229 33327 353229 363431 393633 453834 Heating HighNom.Low dba 352926 322926 33327 373429 353228 37343 373431 43733 4238.534 Refrigerant Type R-41A GWP 2,87.5 Piping connections Liquid OD mm 6.35 9.52 Gas OD mm 17 15.9 Drain VP2 (I.D. 2O.D. 26) Power supply PhaseFrequencyVoltage HzV 1~622-2422 Current - Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC4C65 Wired remote control BRC1E53A BRC1E53B BRC1E53C BRC1D52 Simplified wired remote control for hotel applications BRC2E52C (heat recovery type) BRC3E52C (heat pump type) 157

Detailed technical drawings VIEW ALL FXSQ-A TECHNICAL FXSQ15-32A FXSQ15-32A 17 Ø Suspension bolt 5 69 ( Knockout hole. ) 342 4 Fresh air intake position 65 38 19 2x65=13 25 8 31 3 or more 14 126 P.C.D. 4-M4 (CLASS 2) 245 178 2x14=28 365 588Suspension position 4x65=26 32 or more 179.2 4 145 1 145 11 21 95 21 Suspension position 63 Item Name Description Liquid pipe connection port Gas pipe connection port Drain pipe connection Wiring connection Power supply connection Drain outlet Air filter Air suction side Air discharge side Nameplate Ø6.35 flared connection Ø17 flared connection VP2 (OD Ø26, ID Ø2) VP2 (OD Ø26, ID Ø2) When installing optional accessories, refer to their respective documentation. The ceiling depth varies according to the documentation of the specific system. 3D94888A FXSQ4-A FXSQ4-A 17 Ø ( Knockout hole. ) Fresh air intake position Suspension bolt 65 7 492 69 4 38 19 2x65=13 25 8 31 3 or more 14 126 P.C.D. 4-M4 (CLASS 2) 245 178 3x14=42 515 738 Suspension position 6x65=39 32 or more 179 654 4x145=59 11 21 95 21 63 Suspension position 42 155 13 13 12 5- Ø 4.7 HOLE Item Name Description Liquid pipe connection port Gas pipe connection port Drain pipe connection Wiring connection Power supply connection Drain outlet Air filter Air suction side Air discharge side Nameplate Ø6.35 flared connection Ø17 flared connection VP2 (OD Ø26, ID Ø2) VP2 (OD Ø26, ID Ø2) When installing optional accessories, refer to their respective documentation. The ceiling depth varies according to the documentation of the specific system. 3D94919A 158

FXSQ63-8A FXSQ63-8A VIEW ALL FXSQ-A TECHNICAL Detailed technical drawings 17 Ø ( Knockout hole. ) Fresh air intake position Suspension bolt 65 69 792 4 38 19 2x65=13 25 31 8 3 or more 14 126 P.C.D. 4 x M4 (CLASS 2) 245 178 5x146=73 815 32 or more 179 11 21 138 Suspension position 11x65=715 954 6x145=89 95 21 Suspension position 63 42 135 125 98 117 135 125 8- Ø4.7 HOLE Item Name Description Liquid pipe connection port Gas pipe connection port Drain pipe connection Wiring connection Power supply connection Drain outlet Air filter Air suction side Air discharge side Nameplate Ø9.52 flared connection Ø15.9 flared connection VP2 (OD Ø26, ID Ø2) VP2 (OD Ø26, ID Ø2) When installing optional accessories, refer to their respective documentation. The ceiling depth varies according to the documentation of the specific system. 3D94916A FXSQ-125A FXSQ-125A 17 Ø ( Knockout hole. ) Fresh air intake position Suspension bolt 65 14 69 1192 4 38 19 2x65=13 25 31 8 3 or more 14 126 P.C.D. 4 x M4 (CLASS 2) 245 178 7x156= 192 32 179 1215 or more 11 21 1438Suspension position 16x65=14 1354 8X1=12 63 95 226 Suspension position 42 1 147.5 147.5 115 115 1 147.5 147.5 115 1x Ø 4.7 HOLE Item Name Description Liquid pipe connection port Ø9.52 flared connection Gas pipe connection port Ø15.9 flared connection Drain pipe connection VP2 (OD Ø26, ID Ø2) Wiring connection Power supply connection Drain outlet VP2 (OD Ø26, ID Ø2) Air filter Air suction side Air discharge side Nameplate When installing optional accessories, refer to their respective documentation. The ceiling depth varies according to the documentation of the specific system. 3D94917A 159

FXSQ14A Detailed technical drawings FXSQ14A VIEW ALL FXSQ-A TECHNICAL 17 Ø ( ) Knockout hole. Fresh air intake position Suspension bolt 65 15 69 1342 4 38 62 19 2x65=13 25 31 8 3 or more 14 126 P.C.D. 4 x M4 (CLASS 2) 245 178 8x156=1248 1365 1588 Suspension position 32 or more 179 14 9x1=13 11 21 6 18x65= 117 6 95 21 63 Suspension position 42 151 123 122 123 116 115 151 123 122 123 116 1x Ø4.7 HOLE Item Name Description Liquid pipe connection port Ø9.52 flared connection Gas pipe connection port Ø15.9 flared connection Drain pipe connection VP2 (OD Ø26, ID Ø2) Wiring connection Power supply connection Drain outlet VP2 (OD Ø26, ID Ø2) Air filter Air suction side Air discharge side Nameplate When installing optional accessories, refer to their respective documentation. The ceiling depth varies according to the documentation of the specific system. 3D94928A FXSQ15A 2 Fan characteristics (1) 2 Air flow autoadjustment 1 1 L T () limit L of T ESP () ESP Upper Lower limit of of ESP Upper limit 5,5 6,5 7,5 8,5 9,5 Air flow rate [m³min] ESP MAX 1 - STD 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 7,5 Airflow rate [m 3 min] 8,5 9,5 5,5 6,5 7,5 8,5 9,5 Airflow rate [m 3 min] by air flow auto adjustment by air flow auto adjustment The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure 3D96999 16

VIEW ALL FXSQ-A TECHNICAL Detailed technical drawings FXSQ2-25A 2 1 5,5 6,5 7,5 8,5 9,5 ESP MAX 1 - STD 3 Fan characteristics (1) Air flow rate [m 3 min] 2 1 5,5 6,5 7,5 8,5 9,5 Air flow rate [m 3 min] by air flow auto adjustment by air flow auto adjustment 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 8 9 Air flow rate [m 3 min] 1 The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure FXSQ32A 3D9568A 2 Fan characteristics (1) 2 1 1 5,5 6,5 7,5 8,5 9,5 1,5 ESP MAX 1 - STD 3 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 8 9 Air flow rate [m 3 min] Air flow rate [m 3 min] 1 11 5,5 6,5 7,5 8,5 9,5 1,5 Air flow rate [m 3 min] by air flow auto adjustment by air flow auto adjustment The fan characteristics shown are in "fanonly" mode. ESP: External Static Pressure 3D95681A 161

Detailed technical drawings VIEW ALL FXSQ-A TECHNICAL FXSQ4A 2 Fan characteristics (1) 2 1 ESP MAX 1 - STD 3 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 9 1 11 12 13 14 15 16 17 Air flow rate [m 3 min] 13 14 15 16 17 Air flow rate [m 3 min] 1 9 1 11 12 13 14 15 16 17 The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure Air flow rate [m 3 min] by air flow auto adjustment by air flow auto adjustment 3D95682A FXSQA 2 1 9 1 11 12 13 14 15 16 17 9 1 11 12 13 14 15 16 17 Air flow rate [m³min] Air flow rate [m³min] ESP MAX 1 - STD 3 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 Fan characteristics (1) 13 14 15 16 17 Air flow rate [m³min] Field settingwith remote control 2 1 by air flow auto adjustment by air flow autoa djustment The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure 3D95688A 162

VIEW ALL FXSQ-A TECHNICAL Detailed technical drawings FXSQ63A 2 Fan characteristics (1) 1 L T () limit of Upper ESP 12 13 14 15 16 17 18 19 2 21 22 23 24 Air flow rate[m³min] 2 1 12 13 14 15 16 17 18 19 2 21 22 23 24 Air flow rate[m³min] ESP MAX 1 - STD 3 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 18 19 2 21 22 23 24 Air flow rate[m³min] The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure by air flow auto adjustment by air flow auto adjustment 3D9569A FXSQ8A 2 1 13,5 14,5 15,5 16,5 17,5 18,5 19,5 2,5 21,5 22,5 23,5 24,5 25,5 26,5 Air flow rate[m³min] ESP MAX 1 - STD 4 Fan characteristics (1) 2 1 13,5 14,5 15,5 16,5 17,5 18,5 19,5 2,5 21,5 22,5 23,5 24,5 25,5 26,5 Air flow rate[m³min] by air flow auto adjustment by air flow auto adjustment 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 19,5 2,5 21,5 22,5 23,5 24,5 25,5 26,5 Air flow rate[m³min] The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure 3D95692A 163

Detailed technical drawings VIEW ALL FXSQ-A TECHNICAL FXSQA 2 Fan characteristics (1) 2 1 1 19,5 2,5 21,5 22,5 23,5 24,5 25,5 26,5 27,5 28,5 29,5 3,5 31,5 32,5 33,5 34,5 35,5 36,5 Air flow rate[m³min] 19,5 2,5 21,5 22,5 23,5 24,5 25,5 26,5 27,5 28,5 29,5 3,5 31,5 32,5 33,5 34,5 35,5 36,5 Air flow rate[m³min] ESP MAX 1 - STD 4 by air flow auto adjustment by air flow auto adjustment 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 27 28 29 3 31 32 33 34 35 36 37 The fan characteristics shown are in "fan only" mode. Air flow rate[m³min] ESP: External Static Pressure 3D95696A FXSQ125A 2 1 22 23 24 25 26 27 28 29 3 31 32 33 34 35 36 37 38 39 4 41 Air flow rate[m³min] ESP MAX 1 - STD Fan characteristics (1) 2 1 22 23 24 25 26 27 28 29 3 31 32 33 34 35 36 37 38 39 4 41 Air flow rate[m³min] by air flow auto adjustment by air flow auto adjustment 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 3,5 31,5 32,5 33,5 34,5 35,5 36,5 37,5 38,5 39,5 4,5 41,5 Air flow rate[m³min] The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure 3D95697A 164

VIEW ALL FXSQ-A TECHNICAL Detailed technical drawings FXSQ14A 2 Fan characteristics (1) 2 1 25 26 27 28 29 3 31 32 33 34 35 36 37 38 39 4 41 42 Air flow rate[m³min] ESP MAX 1 - STD 2 19 18 17 16 1 14 13 12 11 9 8 7 6 4 3 2 1 35 36 37 38 39 4 41 42 Air flow rate[m³min] 1 23 24 25 26 27 28 29 3 31 32 33 34 35 36 37 38 39 4 41 42 43 44 45 Air flow rate[m³min] by air flow auto adjustment by air flow auto adjustment The fan characteristics shown are in "fan only" mode. ESP: External Static Pressure 3D96688A 165