Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Similar documents
Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Thermal Management Products & Accessories for Enclosures

HEATING. Anticondensation Heaters

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Stego accessories for cabinets

Water Detection Controllers

Heaters, Thermostats and Hygrostats

Oxygen (O2) Single-Point Gas Detection System

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

HUMIDISTATS and Electronic humidity controls

Life insurance for your electronics

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Cooling unit Mechanical control

BC3250. Blowdown Controller

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

INPUT / OUTPUT MINI MODULES

Enclosure Heaters and Fan Heaters

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Danfoss gas detection units

UDC100 Universal Digital Controller Specifications

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Control and Annunciator Panels. Compact systems of signalling and control

02/11/2015

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Flush-mounted room thermostat

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

CLEANROOM MONITOR CR3A Network - Installation Instructions

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

UDC 700 Universal Digital Controllers and Indicator Specifications

02/11/2015

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

I/A Series 716C 1/16 DIN Temperature Controller

JDDT1 - Single Stage Digital Thermostat

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Rittal roof-mounted fans Efficiency on top

Process Alarm Module RTA 421

Danfoss gas detection units

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Technical Manual. Level Alarm Unit CARLA & WIDS

T7984 A,B,C Electronic Modulating Control Thermostats

DEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications

eed quality electronic design USER s MANUAL

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Model A1600 Series Annunciator

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

DIGITAL ALARM UNIT Model ALU-AP

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Two-Channel Gas Controller

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ClimaSys Resistance heaters Selection guide

Introduction to Flow Switch

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Power Supply Display Module PSDM. Installation and Operation Manual

Unipower HPL420. User s Manual. True Motor Power Monitor with... Typical Applications. High Trip Alarm. Low Trip Alarm.

Instruction Manual Model A

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard 2-channel Gas Controller MGC-03

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

T5000 LCD Digital Fan Coil Thermostat

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Tower & Obstruction Lighting Controls

Acessories BROCHURE JUNHO 2013

Ionisation single-tube smoke detector for duct mounting

Sitron s CF Line of Flow Switch Monitors

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Speed and Frequency Seite 1 von 7

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Operating Instructions. For. Alarm Control Module. Model SSR 500

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Thermal management for your cabinets!

ST Wiring diagram. Product description. Standard temperature controller. Order number

Dixell Installing and Operating Instructions release 7.0

General Specifications

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Retroreflective sensor with polarization filter

Instruction FH-CWP Thermostat

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Dissolved Oxygen Analyzers

Semi flush-mount room thermostat

Plug-in Base, Long Range Sensor E3B2

Transcription:

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

CONTROL CONTROLLO THV THR THERMOSTATS Compact Thermostat for DI 35 mm. rail mounting. Based on bimetallic junction, provides high capacity O or C contact. Two versions available. THVx NO Contact Typically used for controlling ventilation devices THRx NC Contact Typically used for controlling heaters Features Unit THR1 THR2 THR3 THV1 THV2 THV3 Contact function NC NC NC NO NO NO Temperature setting range C 10/+50 0/+60 +20/+80 10/+50 0/+60 +20/+80 Precision C ±4 Hysteresis C 7 250Vac resistive load (inductive load) A 10 (1.6) 125Vac resistive load (inductive load) A 15 (2.5) Max. switching power in Vdc W 30 Temperature sensor type Thermostatic bimetal Contact type Snap action Contact resistance mohm < 10 Service life cycles > 100 000 Electrical connections 2pole terminal for 2.5 mm² wire Operating temperature C ( F) 25/+80 (13/+176) Storage temperature C ( F) 45/+80 (49/+176) Installation position Variable UL File n. E348803 Dimensions HxWxD mm 61x34x35 Weight (with packaging) kg 0.048 (0.055) 47

Thermostats THRV THVV DOUBLETHERMOSTATS Compact double thermostat for DI 35 mm. rail mounting. Based on bimetallic junction, provide high capacity and separated O and C contacts in different combinations. Three versions available. THRV13 NC NO THRV22 NC NO THVV22 NO NO Features Unit THRV13 THRV22 THVV22 Contact function NC NO NC NO NO NO Temperature setting range C 10/+50 +20/+80 0/+60 0/+60 0/+60 0/+60 Precision C ±4 Hysteresis C 7 250Vac resistive load (inductive load) A 10 (1.6) 125Vac resistive load (inductive load) A 15 (2.5) Max. switching power in Vdc W 30 Temperature sensor type Thermostatic bimetal Contact type Snap action Contact resistance mohm < 10 Service life cycles > 100 000 Electrical connections 2pole terminal for 2.5 mm² wire Operating temperature C ( F) 25/+80 (13/+176) Storage temperature C ( F) 45/+80 (49/+176) Installation position Variable UL File n. E348803 Dimensions HxWxD mm 61x53x35 Weight (with packaging) kg 0.080 (0.09) 48

CONTROLLO Thermostats THRF THVF BIMETALLIC THERMOSTAT FIXED SET Fixed set point compact thermostat for DI 35 mm. rail mounting. Based on bimetallic junction, provides high capacity O or C contact. Two versions available. Features Unit THRF05 THVF35 THVF50 Contact function NC NO NO Temperature set (hysteresis) C +5 (10) +35 (10) +50 (10) Precision C ±4 240Vac resistive load (inductive load) A 5 (1.6) 120Vac resistive load (inductive load) A 10 (2.0) Max. switching power in Vdc W 30 Temperature sensor type Thermostatic bimetal Contact type Snap action Contact resistance mohm < 10 Service life cycles > 100.000 Electrical connections 2pole terminal for 2.5 mm² wire Operating temperature C ( F) 40/+80 (40/+176) Storage temperature C ( F) 45/+80 (49/+176) Installation position Variable Dimensions HxWxD mm 43x27x35 Weight (with packaging) kg 0.024 (0.056 2pcs x pack) THRF THVF 49

Thermostats THS THERMOSTAT CHANGEOVER CONTACT WITH LOW HYSTERESIS Features Unit THS2 Contact function Change over contact Temperature setting range C 0 / +60 Precision C ±3 Hysteresis C 1 NC 100250VAC (inductive load cos phi 0.6) A 10 (2) NO 100250VAC (inductive load cos phi 0.6) A 5 (2) Max. switching power in Vdc W 30 Temperature sensor type Thermostatic bimetal Service life cycles > 100 000 Electrical connections 4pole terminal for 2.5 mm² wire Operating temperature C ( F) 40/+80 (40/+176) Storage temperature C ( F) 45/+80 (49/+176) Installation position Variable Dimensions HxWxD mm 64x37x45 Weight (with packaging) kg 0.07 (0.08) 50

CONTROLLO Hygrostat EUH HYGROSTAT Electronic Hygrostat for DI 35 mm. rail mounting. Typically used to control enclosure heaters. LED display of power on and status. Features Unit EUH11 EUH22 Power supply V/Hz 115/5060 230/5060 Relative Humidity setting range RH% 2090 Relative Humidity Hysteresis % 5 Reaction time sec 60 NO at 250Vac resistive load A 10 NO at 30Vdc resistive load A 8 NO at 240Vac motor load Hp 1/2 NO at 120Vac motor load Hp 1/4 NC at 250Vac resistive load A 10 NC at 30Vdc resistive load A 8 Contact type Change over Contact resistance < 10 Service life cycles > 100 000 Electrical connections 5pole terminal for 2.5 mm² wire Optical signal LED Operating / Storage temperature C ( F) 40/+80 (40/+176) Installation position Vertical Dimensions HxWxD mm 69x53x50 Weight (with packaging) kg 0.11 (0.12) 53 50 50 60 40 70 30 80 20 90 RH % 69 51

ThermoHygrostat ETUH THERMOHYGROSTAT Electronic Hygrothermostat for DI 35 mm. rail mounting. Typically used to control enclosure heaters. The change over contact triggers either for high humidity or low temperature, independently set adjustable. LED display of power on and status. Features Unit ETUH11 ETUH22 Power supply V/Hz 115/5060 230/5060 Temperature setting range C 0 / +60 Precision C ±1 Temperature Hysteresis C 2 Relative Humidity setting range RH% 2090 Relative Humidity Hysteresis % 5 Reaction time sec 60 NO at 250Vac resistive load A 10 NO at 30Vdc resistive load A 8 NO at 240Vac motor load Hp 1/2 NO at 120Vac motor load Hp 1/4 NC at 250Vac resistive load A 10 NC at 30Vdc resistive load A 8 Contact type Change over Contact resistance < 10 Service life cycles > 100 000 Electrical connection 5pole terminal for 2.5 mm² wire Optical signal LED Operating / Storage temperature C ( F) 40/+80 (40/+176) Installation position Vertical UL File n. E348803 Dimensions HxWxD mm 69x53x50 Weight (with packaging) kg 0.11 (0.12) 53 50 50 60 40 70 30 80 20 90 RH % 86 68 30 104 20 40 50 122 10 50 0 60 32 140 T C/ F 69 52

CONTROLLO Hygrostat MUH MECHANICAL HYGROSTAT Hygrostat for DI 35 mm. rail mounting. Typically used to control enclosure heaters. Features Unit MUH Relative Humidity setting range RH% 2090 Relative Humidity Hysteresis RH% 5 (max 10) Precision RH% ±4 NC at 240Vac resistive load A 2.2 NC at 120Vac resistive load A 4.4 NO at 240Vac resistive load A 5 NO at 120Vac resistive load A 10 Contact type Change over Electrical connection 3pole terminal for 2.5 mm² wire Operating temperature C ( F) 10/+50 (+14/+122) Storage temperature C ( F) 45/+80 (49/+176) Installation position Vertical Dimensions HxWxD mm 91x54x48 Weight (with packaging) kg 0.15 (0.17) 53

Thermostats ETHM ETHDM TEMPERATURE CONTROLLERS Compact Size 1 DI Module (17,5mm) or 2 DI modules (35mm) Supply 2030 VAC/DC or 200240 VAC Din rail mounting Analog temperature adjustment Suitable for temperature control inside electric panel (Fan control and resistor control) One or two independent TC probe inputs 1 relay output x 8A (ETHM10,ETHM14), 2 relay outputs x 16A (ETHDM10, ETHDM14) Features Unit ETHM10 ETHM14 ETHDM10 ETHDM14 Power supply V 200240 VAC 2030 VAC/DC 200240 VAC 2030 VAC/DC Input NTC (10k 25 C) Relay 1 SPDT output (8A) 2 SPDT outputs (16AAC1) Control ON/OFF Measurement range C NTC 20 ~ +60 C Sampling rate Hz 12 Symmetric hysteresis Adjustable from +1 to +5 C on both outputs Operating temperature C ( F) 20/+65 (4/+149) Operating humidity (no condensate) RH% 30 ~ 95 Housing selfextinguishing plastic UL94V0 Dimensions HxWxD mm 17.5x64x98mm 1 Din rail module 35x64x98mm 2 Din rail module Connessions 2.5 mm² screw terminal block Weight (with packaging) Kg 0,045 (0,055) 0,070 (0,090) The ETHDM10 and ETHDM14 are factory equipped with an integral TC on the thermostat (terminals 12) and a bridge between terminals 2 and 1A. In this con guration the two set points of outputs OUT1 and OUT2 will refer to the temperature measured by the integrated TC probe. Replacing the bridge between terminals 2 and 1A with a second TC probe, output OUT1 will be controlled by the temperature measured at TC probe 1 (on the thermostat), output OUT2 will be controlled by the temperature measured at TC probe 2 (terminals 2 and 1A). 54

CONTROLLO Thermostats ETH ETHD TEMPERATURE CONTROLLERS Compact Size 1 DI Module (17,5mm) or 2 DI modules (35mm) Supply 1030AC/DC or 200240VAC Din rail mounting Digital adjustment of tempearture (2 red digit) Appropriate for temperature control inside electric panel (fan and resistor control) TC probe input 1 or 2 relay outputs Features Unit ETH10 ETH14 ETHD10 ETHD14 Power supply V 200240 VAC 1030 VAC/DC 200240 VAC 1030 VAC/DC Input NTC (10k 25 C) Relay 1 SPDT output (10AAC1) 2 SPDT outputs (10AAC1) Control ON/OFF Overall accuracy % +/ 0.5 full scale Display resolution 1 Measurement range C NTC 20 ~ +65 C probe on the controller / NTC 35 ~ +99 C external probe Sampling rate Hz 12 Display 2 red digit Parameters programming by keyboard Operating temperature C ( F) 20/+65 (4/+149) Operating humidity (no condensate) RH% 30 ~ 95 Housing selfextinguishing plastic Dimensions HxWxD mm 17.5x64x98mm 1 Din rail module 35x64x98mm 2 Din rail module Connessions 2.5 mm² screw terminal block Weight (with packaging) Kg 0,045 (0,055) 0,070 (0,090) 55

Thermostats Fan speed controller FSC FAN SPEED CONTROLLER Electronic temperatureregulated fan speed controller for DI 35 mm. rail mounting. Speed controller helps to reduce fan noise, air ow rate is reduced to the optimum speed required. Features Unit FSC Power supply V/Hz 100230/5060 Temperature setting range C +20 / +60 Fan speed setting range % 0 100 Speed controller partialization of wave Input NTC sensor Max. output fan 300 W (100230/5060Hz) Electrical connection terminal for 2.5 mm² wire Optical signal LED Operating / Storage temperature C ( F) 10/+70 (+14/+158) Installation position Vertical Dimensions HxWxD mm 68x53x38 Weight (with packaging) kg 0.10 (0.11) 56

CONTROLLO Safety FS FLASHING SAFETY DEVICE The ashing safety devices series FS prevents accidents, alerting the operator that the electrical system is live. The FS devices are suitable for connection to three or singlephase lines. FS is also a phaseloss and phasesequence control device: in case of failure, it points out the missing phase. The device functions can be increased with auxiliary contacts that allow to switchon the lamp when opening the cabinet door or to control other equipment inside the cabinet (air conditioner, etc.) Features Unit FS FSL FSLA Power supply V/Hz 1ph 115230/5060 or 3ph 400/5060 Power on, Phase sequence, Yes/No Yes Yes Yes Phase loss Signal n 3 LEDs, red n 3 LEDs, red n 3 LEDs, red Contact for lamp Yes/No No Yes Yes Contact type NC NC Max current A 5 5 Service life Cycles > 25.000 > 25.000 FUNCTIONS Auxiliary Contact Contact type Max current Service life Yes/No A Cycles No No Yes Change over 5 > 25.000 Probe extension mm Adjustable 1116 Casing Polycarbonate, Yellow Connection on terminals mm 2 n. 6x4 n. 8x4 n. 11x4 Mounting Adjustable fixing bracket 125 mm interlock Protection class I Operating/Storage temperature C( F) 10 +70 (+14 +158)/20 +80(4 +176) Installation position Variable Dimensions HxWxD mm 34x112x68 (+16) Weight (with packaging) kg 0.15 (0.25) Package dimensions HxWxD mm 46x145x88 FIN DOOR LIMIT SWITCH Features Unit FINCOR FINRIP Contacts type Zb type snap action (1NO+1NC) Rated current at 230V(400V) AC15 A 3.1(1.9) Protection degree EN60529 IP65 Protection Class II Operating temperature C ( F) 25/+70 (13/+158) Rated insulation voltage Ui V 690 Service life Cycles > 25.000 Cable inlet PG13,5 cable gland Mechnical lock Yes/No No Yes Dimensions HxWxD mm 75x31x31 91x31x39 Weight (with packaging) kg 0.04 (0.10) 0.05 (0.11) EN6094751, IEC 94751 Required on most enclosures for safety and operation of auxiliary circuits, such as switching on lamps or switching off ventilation/air conditioning when the door is open. FI Limit switches can be equipped with the optional bracket FI STAFF for xing and positioning. 300 Roundhill Dr. Rockaway, NJ 07866 Tel: 9735862500 www.norstat.com