Wöhler DM Operating Manual Digital Manometer

Similar documents
MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Manual Wöhler Rotary Viper Vent M 10

SIMPLE. QUICK. CLEAN.

Pressure measuring instruments

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Importance of a Draught Regulator

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

portable gas analyser

Website:

portable gas analyser

Riva Studio Dedicated Sealed External Air Kit

Forced draught gas burner

ST 40 Oil Burner. Installation & Maintenance Manual

Tune-Rite Software Operation Manual

eurofire BIG 100, 200, 300 kw

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Dovre 250 Cast Iron Gas Stove

ADC150 Automatic Draft Control

99 Washington Street Melrose, MA Phone Toll Free Visit us at

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Light oil burners. One stage operation

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTALLATION AND OPERATION MANUAL

Operating Instructions

1. GENERAL SAFETY RULES

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

100 step modulated Wood Pellet Boiler

Forced draught gas burner

BG2000S PRE-MIX GAS BURNER

USER S INFORMATION MANUAL

Operating instructions

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Log fired heating system

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Operating Instructions

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

INSTRUCTION FOR THE USER THC V E OIL BLU

Instructions Manual SHC520X - SHC700X

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

Columbia Boiler Company

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Boiler Technical Specifications (2013)

EBC 12 Modulating Fan Control

Gebrauchsanweisung User manual 使用手冊マニュアル

GB162 Concentric Horizontal Vent Kit

Installation & Maintenance Manual

USERS MANUAL FOR GAS BOILERS

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

GAS ANALYSIS / DETECTION Gas Detector

Settings and Maintenance of the CombinAir

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Owner s Manual for. PennStoker

WHE 2.24 / WHE 2.24 FF

TECHNICAL AND OPERATIONAL DOCUMENTATION

TDS 100. EN Operating Manual Electrical Fan Heater

Manual Vane Anemometer PCE-VA 20

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

FORCED DRAFT CONVERSION KIT #253

Twin Wall Installation Instructions And Maintenance Guide

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR

The Gas Safety (Installations and Use) Regulations 1998.

Light oil - kerosene burner

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

USER MANUAL. Cooker Hood ZHG51250GA

Instruction Manual. Electronic gas and smoke detector GRM

Operating Instructions

Technical data Chimney fans, controllers and accessories in systems for gas fireplaces, stoves and single non-modulating gas boilers

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

1 VICTRIX ZEUS Superior kw I features

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

User s Information Manual

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

modern heating devices

Carbon Monoxide Safety

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

MANUAL Overflow sensor NVF-104/34-PF

SG Burner Only

VH60SS 60CM VISOR HOOD STAINLESS STEEL

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Transcription:

Operating Manual Digital Manometer EN Wöhler DM 2000 Best.-Nr. 23861 2016-07-07 UK & Ireland Partner A1 Services Limited 5 Enterprise Way Jubilee Business Park Derby DE21 4BB Tel +44 (0)1332 382233 Email info@wohler-cameras.co.uk

Garantie und Service Content 1 General... 10 1.1 Information about this operating manual... 10 1.2 Symbols used in this operating manual... 10 1.3 Proper use... 10 1.4 Basic equipment... 10 1.5 Disposal... 11 1.6 Manufacturer's address... 11 2 Technical Data... 12 3 Components... 13 4 Flue Draft Test... 14 5 Temperature... 16 6 Printing... 16 7 Accessories... 16 8 Warranty and Service... 17 8.1 Warranty... 17 8.2 Service... 17 9

General 1 General 1.1 Information about this operating manual 1.2 Symbols used in this operating manual This operation manual allows you to work safely with the Wöhler DM 2000 Digital Manometer. Please keep this operating manual in a safe place for future reference. The Wöhler DM 2000 Digital Manometer should be employed by professionals for its intended use only. We accept no responsibility for any damage or loss resulting from any failure to observe this operating manual. WARNING! Not following this warning can cause injury or death. NOTE! Highlights tips and other useful information. 1.3 Proper use The meter is suitable for the fine tuning of boilers, The draft measurement and the differential pressure measurement Einstellungen des Gasdrucks an Gasfeuerstätten, zur Messung des Gebläsedifferenzdrucks ab 1 Pa/0,01 mbar sowie zur Messung des Schornsteinzugs. 1.4 Basic equipment Meter Scope of supply Wöhler DM 2000 Digital Manometer with batteries Hose 1.5 m 10

General 1.5 Disposal Do not dispose of electronic equipment along with household waste. Dispose of electronic equipment in accordance with valid environmental regulations. Damaged rechargeable batteries are considered hazardous waste. Dispose of damaged or used rechargeable batteries at the collection points provided. 1.6 Manufacturer's address Wöhler Technik GmbH Schützenstr. 41 33181 Bad Wünnenberg, Germany Tel.: +49 2953 73-100 Fax: +49 2953 73-250 E-Mail: info@woehler.de 11

Technical Data 2 Technical Data Beschreibung Differential Pressure Range Angabe ± 2 bar Accuracy < 3 % o.r. ± 200 Pa whichever is greater Temperature (optional) Range -20 C up to +99 C Accuracy: < 1 C Resolution: 0.1 C Unit Power supply Depending on the version mbar or Pa 2 batteries AA, 1,5 V Storage temperature -20 C up to +60 C Working temperature -5 C up to +60 C 12

Components 3 Components IR port negative pressure positive pressure Opperator button : Press button to turn on Press during measurement to zero Press twice during measurement to print Hold button for 3 sec. to turn off temperature 13

Flue Draft Test 4 Flue Draft Test Safety Warning! You must be qualified to work on heat appliances and gas, oil or other fuel supplies. For further instructions contact your local authorities before you start the job. The constant flow of flue gases at the correct rate of flow with the least possible variation is required for safe and efficient combustion. Insufficient flue draft will cause ignition difficulties and is likely to result in fume emission and potential health risk. Too much draft will make control of the fire difficult and may result in overheating. In this instance, fitting a draft stabiliser may be required. An appliance manufacturer will specify a range of flue draft conditions under which their appliance will operate. Choosing the correct place for measuring The correct place for measuring the chimney draft is close to the appliance and at least 2 x flue-pipe diameter above the spigot and 15 cm away from any draft stabiliser. Some appliances include purpose made flue draught test points for insertion of test equipment sampling probes. Where no purposemade flue draught point is included a suitable point will need to be provided adjacent to the appliance outlet. In some instances, a draft measurement can be taken by temporarily removing a sweeping access cover and using a cone or plate with a hole in the centre to prevent secondary air entry and to enable the sampling probe to be inserted. A flue draught reading should be taken before the appliance is lit to identify any potential problems which will result from down draught. 14

Flue Draft Test Procedure for Taking Flue Draft Readings The typical procedure when using a Wohler mechanical draft gauge is as follows: 7. Visually inspect the draft gauge for signs of damage and/or defect. 8. Ignite a small amount of fuel in the appliance and leave to burn for 20 minutes. 9. Turn on the unit and allow the display to stabilise and settle to zero. 10. Connect the rubber hose to the negative connector on the unit. 11. Connect the stainless steel probe to the end of the rubber hose. 12. Insert metal sampling tube into test point preventing secondary air entry. 13. Wait approximately 30 seconds for stabilisation and then take a draught reading. NOTE! Atmospheric or weather conditions may cause incorrect draft readings. Depending upon the draft reading obtained, it may be necessary to adjust the appliance air control devices and/or the flue draft stabiliser (if fitted). Any adjustment should be made in accordance with the manufacturer s instructions and the draught reading should be retaken after each adjustment. If acceptable draft conditions are not able to be achieved, the appliance should be taken out of service and where appropriate the HETAS Unsafe Situations Procedure should be followed whilst the fault is rectified. Refer to Unit HTU03K Section 8 for more details. 15

Temperature 5 Temperature The meter has an internal temperature sensor. An external temperature sensor can be connected to the bottom of the meter, see accessories. NOTE! The temperature reading will not appear in the display but only on the printout. 6 Printing The pressure and the temperature readings can be printed on the Wöhler TD 100 Thermoprinter, see accessories. Switch on the printer. Position the meter next to the printer, so that the IR ports of meter and printer are opposite to each other. Start printing with a doubleclick on the opreation-button of the Wöhler DM 2000. 7 Accessories Hose with draft probe 6 mm Ø, 200 mm long, cone 6 mm Ø and hose 1,5 m long Art n 4578 Pressure Measurement Set for Wöhler Digital Manometer Art n 56126 Combustion air temperature probe, 280 mm, with 1.7 m cable Art n 9611 16

Warranty and Service 8 Warranty and Service 8.1 Warranty Each Wöhler DM 2000 will be tested in all functions and will leave our factory only after extensive quality control testing. If used properly, the warranty period for the DM 2000 will be 12 month from the date of sale. Not covered by the warranty are the batteries and the costs for transport and package. Service by non authorized personnel or making modifications to the meter voids any warranty. 8.2 Service We see SERVICE as a very important element in our business. That is why we are still available to you even after the guarantee period has expired. An immediate repair will be carried out if you bring your meter to one of our approved service centers listed below. You can obtain immediate help from our engineers by telephone. UK & Ireland Partner A1 Services Limited 5 Enterprise Way Jubilee Business Park Derby DE21 4BB Tel +44 (0)1332 382233 Email info@wohler-cameras.co.uk 17