This series of articles is written by senior boiler tech (and all around swell guy) Justin Skinner. Thanks Justin.

Similar documents
Laboratory exercise 3: Condensing water heater

Eligibility criteria

Boiler. Fire tube Boiler:

Best Practices for Condensing Boilers

Energy recovery from exhaust gases using Heat Pipe technology

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

CHAPTER 3 BASIC STEAM CYCLE

CONDENSING BOILER TECHNOLOGY. James Romersberger Quintessence Corporation

The Evolution of. Hot Water. Generation Systems. -Ron George. Geysir at Haukadalur, Iceland ( Ron George, 2016)

SB615/310 Stainless Steel Condensing Boiler

INDUSTRIAL / DOMESTIC WATER HEATERS

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

Design and Construction Standards SECTION PLUMBING EQUIPMENT

2012 UPC Chapter 5 Water Heaters RV

Draft Controls. When to use a Draft Control

Subclass F24H covers heater as such, i.e. the arrangements where the heat is generated.

Intelligent Heating for Your Home

SIOUX HYBRID WATER HEATER

SECTION PLUMBING EQUIPMENT

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

FIELD DRAFT CONTROLS

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

Green Energy Engineering, Inc.

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

WOOD PELLET BOILER QUICK START USER GUIDE

Installation Instructions

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

Buildings that Connect People to Nature. Heating/Cooling/Ventilation Strategy. Create an efficient building envelope.

HYDROCARBONENGINEERING June June 2015

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

Hydronic Product & Application Catalog

A CASE OF BOILER FAILURE DUE TO OVERSIZING OF BOILER FEED PUMP

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

TopGas Wall Hung Condensing Gas Boiler

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

anti-condensation valve

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

2 Minimiser SE - User's

Daikin Altherma hybrid heat pump. The natural combination

DIRECT-CONTACT CONDENSING TECHNOLOGY WATER TUBE BOILERS

G315/6 Cast Iron Boiler

BASIC BOILERS NAME :- DATE :-

- Essay Control Functions and Benefits

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS


Zantingh Burner systems. Reliable energy-saving and environmentally friendly heating solutions

ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES

Considerations for INDUSTRIAL COMBUSTION

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

G315/5 Cast Iron Boiler

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Refrigeration Basics from a Brewery Perspective

G515/7 Cast Iron Boiler

Cow Dung Boiler. An emergency source of steam for solar powered steam pumping systems like the Sunflower.

RHCC Heating System Upgrade. Project Summary

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

G615/11 Cast Iron Boiler

BIOMASS BOILER DUAL THERM

Solar Information. Solar Radiant Heating. Innovating Today s Solar Technology for the Future of Tomorrow

Improving Boiler Stability Through Advanced Regulatory Control

Energy Efficiency Business Rebates Natural Gas Catalog

Selecting a New Water Heater

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

Switching off the heating when you leave the house - is it worth it? John S. Reid

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

Attention is drawn to the following places, which may be of interest for search:

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Laboratory Techniques

Development of Boiler Design

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

G215 G315 Cast Iron Residential Boilers

INSTRUCTION MANUAL FOR OIL BURNER MODELS

solar thermic systems

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

SECTION PLUMBING EQUIPMENT

NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Use of energy recovery systems in air conditioning, ventilation or screening

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Get Wise to ThermWise. An Insider s Guide to ThermWise Rebates

2.0 VISIT TO SITE. It was immediately evident entering the boiler house that there are several issues with the existing installation.

Heating and Cooling IN THIS CHAPTER

User s Information Manual

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

systems); a burner by-

tççç= ÜÉ~íáåÖ çéíáçåë

Transcription:

Boiler Basics Part 1 Types and Components This series of articles is written by senior boiler tech (and all around swell guy) Justin Skinner. Thanks Justin. There are quite a few different types of boilers out in the world. They come in all shapes, sizes, pressures, and types of fuel burned. I m going to go over some of the more common ones, their common components, and why it all matters. First, lets establish what a boiler is. A Boiler is defined as a fuel-burning apparatus or container for heating water, in particular. The in particular part is thrown in there because a lot of boiler systems heat a fluid other than water. Glycol, oil, and process chemicals to name a few. But to keep things fairly simple, we will stick with water. So your basic boiler burns a fuel source to heat water. A water heater, basically. But water heaters are used to produce domestic hot water for showers,sinks, and other household hot water uses. Boilers are used to produce hot water for space heating purposes, dehumidification, and other processes (or even potable water indirectly through and exchanger). For residential and commercial/industrial purposes, there are 2 types of boilers. The most common is the fire tube design. This would include the common sectional type boiler seen in most residential applications. The fuel is burned, and the hot gases pass through a series of flue passages or tubes that are generally steel. The steel composing the flue passages or tubes is heated by the gases passing through. This area does not contain any water, only heat and combustion gases. Water surrounds the flue gas area, but does not actually enter the area. Heat transfer to the water occurs by conduction,

primarily. The steel comprising the flue passages becomes heated, and transfers the heat to water. Hopefully these illustrations help. Commercial Style Fire tube

Residential style sectional, note flue passes As you can see, the tubes or sections that contain the hot flue gases are surrounded by water, which is how this boilers transfer the heat to water. The passages that contain the hot gases also act as the heat exchanger in the boiler. The FIRE (flue gases) is contained in the TUBE (tubes or passages). A water tube boiler is typically used in commercial and industrial applications, and not seen often in residential. As the name implies, the tubes contain the water being heated, and are surrounded by the hot combustion gases. This type often looks like a rectangular box with a burner mounted to it. Its virtually a large fire box with water tubes.

Water Tube Boiler Design Whats the difference in application and why use one type over the other? Water tubes are generally considered safer. They contain much less water than fire tubes, so if a disturbance occurs (tube breaks, boiler melt down) there isn t as much water/steam to have the potential to escape the boiler. The main determining factor of water or fire tube is application. Water tubes are able to handle much higher pressure ( 1000s of psi), and fire tubes generally aren t

designed to be used over 350 psi. Water tubes are available in much larger capacities than fire tubes, and are able to recover a lot faster from a large increase in load demand from a pressure stand point. Meaning if the pressure drops on a fire tube boiler, it takes longer to come back up than on a similarly rated water tube boiler. Fire tube boilers typically have lower operating and maintenance costs, have easier access to the fire and water sides for inspections, and its much easier to replace tubes on a fire tube than a water tube. Generally speaking, if you have fluctuating demand and large swings in steam requirements, a water tube is probably a better fit. If you have a pretty constant load requirement without a lot of swing in steam demands, a fire tube would work fine. My next article will cover boiler components and safeties. Justin

Water Tube Boilers

Fire Tube Boiler