technical catalogue omicron kw Multifunctional Air/Water/Water

Similar documents
ZETA kw. Installation, operating, and maintenance manual. Manual B02 Issue Replaces 04.02

Water chillers water/water type SIGMA Technical information manual

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

CYANTM. Manual for installation, operation and maintenance

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR


WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CRIMSON & CRIMSON MAX

CHAPTER 6 CONDENSING UNITS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

WZH Ground source heat pumps

nemo a hp rcgroupairconditioning R410A

Galletti Water chillers and heat pumps catalogue

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Blue Box Epsilon Echos +

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

kw COOLING kw HEATING

44,9 202,0 kw. technicalcatalogue

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

pyxis pyxisa NEW rcgroupairconditioning

PRODUCT GUIDE

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

PYXIS U PYXIS U. rcgroupairconditioning

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Aquaflair TRAC-TRAF-TRAH

Air Cooled Chillers & Heat Pumps WinPACK HE-A

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

kw. technicalcatalogue

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

Aquaflair. Residential and Industrial Cooling Systems

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

kw. technicalcatalogue

21,8 222 kw COOLING 25,2 236 kw HEATING

HYDRONIC RESIDENTIAL

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Ultimate energy saving technology

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Water cooled chillers and heat pumps

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Transcription:

technical catalogue omicron 37 260 kw Multifunctional Air/Water/Water

INDEX OMICRON MULTIFUNCTIONALS UNITS OMICRON 4T 1 OMICRON 2T 1 LA SERIE 7 OMICRON 8 OMICRON - ELECTRICAL CHARACTERISTICS 12 OMICRON - VERSION WITH STORAGE TANK 14 OMICRON - SOUND POWER AND PRESSURE LEVELS 15 OMICRON /CF 17 OMICRON /CF - - ELECTRICAL CHARACTERISTICS 18 OMICRON /CF - VERSION WITH STORAGE TANK 19 OMICRON /CF - SOUND POWER AND PRESSURE LEVELS 20

Omicron multifunctional units The Omicron are polyvalent units for outdoor installation applied to 2 pipe water air conditioning systems providing chiller water for summer cooling, hot water for winter heating on the same hydraulic circuit, and in a completely autonomous way, hot water for sanitary use all year via one or more dedicated heat recovery condensers. The units have one or two refrigerant circuits according to the capacity and have two hermetic scroll type compressors with orbital motion on each circuit. OMICRON 4T Unit for 4 pipes hydronic air conditioning systems, which enables to have all year around chiller water for the summer cooling and hot water for the winter heating contemporaneously (heat recovery) or in a autonomous way on two dedicated heat exchangers. OMICRON 2T Reversible air/water heat pump with production of sanitary hot water for 2 pipe water air conditioning systems. Blue Box 1

OMICRON 4T: Operation of unit in summer mode - The unit operates in cooling only mode provides chilled water at the heat exchanger user side (evaporator - 03) while heat is rejected by the external side heat exchanger (condenser - 02). - The unit operates in cooling + heat recovery mode provides chilled water on the user side heat exchanger (evaporator - 03) while free heat is recovered to heat the water of the hydro sanitary system through the sanitary side heat exchanger (24). - The unit operates in summer heting only mode provides the facility to produce only hot water on the hot side heat exchanger (24) also when the chilled water temperature of the system is at steady conditions. The electronic control allows the unit to meet the various different requirements of the system throughout the year (see operating limits) via fan speed control. Operation of unit in winter mode - The unit operates in winter heating only mode provides hot water on the on the hot side heat exchanger (24); evaporation occurs on the external side heat exchanger (02). - Defrost is the system where ice formation on the external side exchanger (02), which could let to stop the unit, is eliminated. Blue Box 2

OMICRON 2T: Operation of unit in summer mode - The unit operates in cooling only mode provides chilled water at the heat exchanger user side (evaporator - 03) while heat is rejected by the external side heat exchanger (condenser - 02). - The unit operates in cooling + sanitary hot water mode provides the facility to produce chilled water on the user side heat exchanger (evaporator - 03) while free heat is recovered to heat the water of the hydro sanitary system through the sanitary side heat exchanger (24). - The unit operates in summer sanitary hot water only mode provides the facility to produce only sanitary hot water on the sanitary side heat exchanger (24); evaporation occurs on the heat exchanger situated in the external side (02). Operation of unit in winter mode - The unit operates in room heating only mode provides hot water on the user side exchanger (condenser - 03); evaporation occurs on the external side heat exchanger (02). - The unit operates in winter sanitary hot water only mode provides the facility to produce only sanitary hot water on the sanitary side heat exchanger (24); evaporation occurs on the heat exchanger situated in the external side (02). Given that the unit cannot also produce hot water for room heating simultaneously, priority can be given to demands for sanitary hot water or heating circuit via the proper parameter of the microprocessor control. - Defrost is the system where ice formation on the external side exchanger (02), which could let to stop the unit, is eliminated. Note: Simultaneous operation of heat pump + recovery is not possible because one mode must take priority. It is necessary to give the priority to either the heat pump or the recovery. Blue Box 3

Control of condensation and evaporation pressure This function, required to allow the unit to meet the various different requirements of the system throughout the year, is performed by fan speed control in accordance with the pressure read by the transducers. - Unit OMICRON: Condensing pressure control by fan speed regulator Fan speed is regulated in accordance with the condensation pressure read by the pressure transducers. This allows to extend the operating limits and allows the use under various environment conditions. - Unit OMICRON/CF: Condensation pressure regulation using modulating dampers Regulation is achieved by varying the flow rate of air through the coil in accordance with the condensation pressure read by the pressure transducers. This allows to extend the operating limits and allows the use under various environment conditions. UNIT FRAME Self-supporting frame with removable panels clad with expanded polyurethane sound-absorbing matting, made of galvanised sheet steel with 180 C baked-on polyester powder coating (Colour RAL 5014) to provide a durable weatherproof finish. Threaded fasteners in stainless steel. COMPRESSORS Hermetic type orbital scroll compressors, connected in tandem and equipped with an oil level sight glass, Klixon internal thermal protection and oil equalisation line. The enclosure, which accommodates the compressors and separates them from the air stream, is acoustically insulated by means of sound-absorbing material. Access to the enclosure is permitted even when the unit is running, by removing specifically designed panels. CONDENSER (in chiller mode)/evaporator (heat pump mode) Composed of a high efficiency coil manufactured from copper tubes and aluminium fins. Metal filters are installed as standard to protect the finned core. FANS Units OMICRON: Axial fans directly coupled to 6 pole motors with internal Klixon overload protection. The motor protection is IP 54. The fan is equipped as standard with a safety mesh grille in accordance with UNI EN 294. Unit OMICRON/CF: Centrifugal double inlet type, statically and dynamically balanced, with belt, pulley and three -phase 4-pole motor drive. The fan is equipped with a safety grille to UNI EN 294. EVAPORATOR Stainless steel 316 AISI brazed plate exchanger, thermally insulated with closed cell expanded material. Each evaporator is equipped with a freeze protection temperature probe and each unit features a mechanical flow switch. HEAT RECOVERY CONDENSER Stainless steel 316 AISI brazed plate exchanger, thermally insulated with closed cell expanded material or with pressed polystyrene. REFRIGERANT CIRCUIT Includes: liquid line shut-off valve, charge connections, liquid line sight glass, filter dryer, thermostatic expansion valve with external pressure equalisation, high and low pressure switches for 2 compressors units. For 4-compressor models high and low pressure values and relative condensation and evaporation temperatures are measured by pressure transducers that relay the signals to the controller so that they can be read directly on the display. The high pressure side of the circuit is also equipped with high pressure switches and relief valves. ELECTRICAL PANEL The electrical panel includes: - Main switch; - Thermal-magnetic circuit breakers for the pumps (if available) - Compressor fuses for the power circuit - Fan fuses on OMICRON units and Thermal-magnetic circuit breakers on OMICRON/FC units Blue Box 4

- Compressor contactors; - Fan contactors; - Pump contactors(only version ST P); - Microprocessor to control the following functions: - water temperature regulation; - Freeze protection; - Compressor time intervals; - Compressor start sequence and automatic lead/lag selection; - Alarm signalling; - Alarm reset; - Common alarm contact for remote signalling; - Display for: - inlet and outlet water temperature; - Programmed temperature set-point and differentials; - Alarm descriptions; - Compressor hours run meter; - Number of starts of the unit and the compressors; - High and low pressure values and relative condensation and evaporation temperature values. - Black box function. Electrical power supply [V/f/Hz]: 400/3~/50 ±5% CONTROLS AND SAFETY DEVICES - Chilled water temperature probe (at evaporator inlet) - Freeze protection probe at the outlet of each evaporator - Safety high pressure switch with manual reset - Low pressure switch (with automatic/manual reset controlled by the control) - High pressure relief valve - Compressors over temperature protection; - Fans over temperature protection; - Mechanical flow switch, supplied as standard on all units, as kit for units 3.2 to 13.2, and factory installed for units 14.4 to 26.4 - Probe to control inlet and outlet water temperature (on inlet and outlet of condenser) TESTING The units are tested in the factory and supplied complete with oil and refrigerant. HYDRAULIC MODULE OPTIONS Omicron /ST 2PS : unit with storage tank and pumps. n addition to the components of version STD, this unit includes: insulated storage tank; run and standby circulating pumps, with automatic changeover, expansion tank, check valves and gate valves. Version ST is available in the following additional four configurations: - ST 1PS : with 1 pump and tank; - ST 1P : with 1 pump and no tank. - ST 2P : with 2 pumps and no tank; - ST S : with tank and no pumps; ACCESSORY VERSIONS Version LN: low noise unit In addition to the components of version OMICRON, this unit includes: compressor compartment with full sound insulation using expanded polyurethane sound absorption material with an intermediate layer of high acoustic impedance material applied to the sides of the compartment. Version SLN: extra low noise unit. In addition to the components of version LN, this unit is designed to operate with a slower fan speed to further reduce noise levels. REFRIGERANT CIRCUIT ACCESSORIES - Pressure gauges Blue Box 5

- High and low pressure gauges are available,as an option, for all models. As standard on 4-compressor units low pressure values and relative, condensation and evaporation temperatures are measured by pressure transducers that relay signals that are displayed on the controller. - Compressor suction and discharge valves. HYDRAULIC CIRCUIT ACCESSORIES - Water side relief valve (version ST only). The value is set at 6 bar, corresponding to the maximum permissible working pressure. ELECTRICAL ACCESSORIES - Leaving water temperature control; - RS485 serial interface supporting Carel, Modbus, Echelon and Bacnet protocols; can also be interfaced with Johnson and Trend supervision; - SMS service for management of service; - Single voltage-free contacts for machine status signals; - Power factor correction cosfi >= 0.9 at nominal operating conditions; VARIUOS ACCESSORIES - Rubber anti-vibration mounts on all models - Spring type anti-vibration mounts on models 18.4 to 26.4; - Timber crate packing; - Pallet/skid for container shipment; - Mesh coil guard with metallic filter. Standard equipment on models from 14.4 to 26.4. - Anti-corrosion treatment of coils for use in aggressive environments - Non-standard RAL paint colours - Electronic thermostatic valve - Anti-freeze heater (on heat exchanger sanitary side and heat echanger user side; version ST also on hydraulic circuit and storage tank) Blue Box 6

SERIES The OMICRON series of chillers and heat pums are available in various sizes with capacities from 38 to 266 kw. The model, serial number, characteristics, power supply, the refrigerant gas quantity, etc. are shown by means of decals on the unit. Modello/Model Modell/Modèle Tipo refrigerante Refrigerant type Kältemitteltyp Type rèfrigèrant IP quadro elettrico IP electrical panel IP Schaltschrank IP tableau électrique Matricola Serial number Seriennumer Matricule Corrente massima assorbita Max. absorbed current Max.Stromaunfnahme Courant maxi absorbée Corrente massima di spunto Max starting current Max. Anlaufstrom Courant maxi de démarrage A A Tensione-Fasi-Frequenza Voltage-Phases-Frequency Spannung-Phasen-Frequenz Tension-Phases-Fréquence Tensione circuiti ausiliari Auxiliary circuit voltage Steuerspannung Tension circuits auxiliares Numero circuiti refrigerante Refrigerant circuit number Anzahl der Kältekreise Nombre circuits réfrigérant Press. max refriger. alta/bassa Max. Refrig. pressure high/low Max. N/n Kaltemrttelbetriebsaruck Pression maxi refrig. haute/basse Press. massima circuito idraulico Data di produzione Max. hydraulic circuit pressure Date of manufacture Max. zulässigerdruck im Wassersystem Herstellungstatum Press. Maxi circuit hydraulique Date de production kpa bar Carica refrigerante per circuito(kg)/refrigerant charge per circuit (kg) Kältemittel Füllmenge je Kreislauf (kg)/ Charge r éfrigérant par circuit (kg) C1 C2 C3 C4 kpa bar MODELLO - MODELE - MODEL - TYP MATRICOLA - MATRICULE - SERIAL NO. - SERIENUMMER REFRIGERANTE - REFRIGERANT - KÄLTEMITTEL - REFRIGERANT Blue Box 7

TECHNICAL DATA - OMICRON Refrigerant R4O7C OMICRON 3.2 4.2 5.2 6.2 Cooling (*) Nominal capacity kw 37,1 44,7 51,4 60.3 Evaporator water flow l/s 1,77 2,13 2,45 2.88 l/h 6.377 7.682 8.833 10.379 Evaporator pressure drop kpa 57,2 55,4 45,9 51.4 Heating (**) Nominal capacity kw 36,4 44,8 51,9 60 Condenser water flow l/s 1,74 2,14 2,48 2,87 l/h 6.267 7.968 8.923 10.138 Condenser pressure drop kpa 55,3 55,6 46,8 50,8 Total heat recovery Nominal capacity kw 49,4 59,5 69,4 80,1 Recovery condenser water l/s 2,36 2,84 3,31 3,287 flow l/h 8496,8 10234 11936 13777 Recovery condenser pressure drop kpa 34 35 35 24 Compressors Type scroll Quantità n 2 2 2 2 Circuiti frigoriferi n 1 1 1 1 Absorbed power in cooling (*) kw 12,3 14,8 17.5 19.7 Absorbed power in heating (**) kw 12,7 15,9 18.4 20.9 Absorbed power in heat kw 12,3 14,8 17.1 60.4 recovery Capacity steps % 0-50-100 0-50-100 0-50-100 0-50-100 Fans Type Axial Total air flow m 3 /s 4,47 4.47 4.47 4.53 m 3 /h 16.100 16.100 16.100 16.300 Fan motor power n x kw 2 x 0,6 2 x 0,6 2 x 0,6 2 x 0,6 Revolution speed RPM 860 Fan power supply V/ph/Hz 230/~/50 Refrigerant charge Version 4T kg 1 x 14,5 1 x 14,5 1 x 14,5 1 x 19,5 Version 2T kg 1 x 15 1 x 15 1 x 15 1 x 22 Oil Charge l 1 x 7,5 1 x 7,5 1 x 10 1 x 10 Brand Maneurop Type 160 SZ Evaporator Type Plates Water volume l 4,6 5,7 7,4 8,4 Max operating pressure water bar 30 side Length mm 2.233 2.233 2.233 2.233 Width mm 1.043 1.043 1.043 1.043 Heigth mm 1.740 1.740 1.740 1.740 Operating weight kg 594 604 625 672 (*) ambient air temperature 35 C; evaporator entering/leaving water temperature 12-7 C (**) ambient air temperature 8 C DB, 70%RH; condenser entering/leaving water temperature 40-45 C Blue Box 8

TECHNICAL DATA - OMICRON Refrigerant R4O7C OMICRON 3.2 4.2 5.2 6.2 Cooling (*) Nominal capacity kw 67,5 77,6 91,6 102,4 Evaporator water flow l/s 3,23 3,71 4,37 4,89 l/h 11.608 13.347 15.748 17.611 Evaporator pressure drop kpa 43,7 45,4 47,9 44,8 Heating (**) Nominal capacity kw 68,1 78,7 92,7 106,6 Condenser water flow l/s 3,25 3,76 4,43 5,10 l/h 11.712 13.530 15.937 18.343 Condenser pressure drop kpa 44,4 46,5 49 48,4 Total heat recovery Nominal capacity kw 90,8 104,9 123,6 142,4 Recovery condenser water l/s 4,34 5,011 5,9 6,8 flow l/h 15617,6 18042,8 21259 24492,8 Recovery condenser pressure drop kpa 24 25 28 27 Compressors Type scroll Quantità n 2 2 2 2 Circuiti frigoriferi n 1 1 1 1 Absorbed power in cooling (*) kw 22,7 26,6 31,3 37,6 Absorbed power in heating (**) kw 23,4 27,5 32,1 36,7 Absorbed power in heat kw 22,2 26 30,6 35,2 recovery Capacity steps % 0-50-100 0-50-100 0-50-100 0-50-100 Fans Type Axial Total air flow m 3 /s 4,53 4,39 6,83 6,83 m 3 /h 16.300 15.800 24.600 24.600 Fan motor power n x kw 2 x 0,6 2 x 0,6 3 x 0,6 3 x 0,6 Revolution speed RPM 860 Fan power supply V/ph/Hz 230/~/50 Refrigerant charge Version 4T kg 1 x 19,5 1 x 22 1 x 27,5 1 x 27,5 Version 2T kg 1 x 22 1 x 27 1 x 32 1 x 32 Oil Charge l 2 x 4 2 x 6,6 1 x 8 + 1 x 6,6 2 x 8 Brand Maneurop Type 160 SZ Evaporator Type Plates Water volume l 4,2 4,8 6,3 7,3 Max operating pressure water bar 30 side Length mm 2.233 2.233 3.234 3.234 Width mm 1.043 1.043 1.144 1.144 Heigth mm 1.740 1.740 1.740 1.740 Operating weight kg 690 737 981 1.058 (*) ambient air temperature 35 C; evaporator entering/leaving water temperature 12-7 C (**) ambient air temperature 8 C DB, 70%RH; condenser entering/leaving water temperature 40-45 C Blue Box 9

TECHNICAL DATA - OMICRON Refrigerant R4O7C OMICRON 12.2 13.2 14.4 16.4 Cooling (*) Nominal capacity kw 117,9 126,6 137 157,6 Evaporator water flow l/s 5,63 6,05 6,55 7,53 l/h 20.283 21.780 23.567 27.103 Evaporator pressure drop kpa 50,7 43,2 51,8 55,8 Heating (**) Nominal capacity kw 119,5 132,4 136,2 157,3 Condenser water flow l/s 5,71 6,33 6,51 7,52 l/h 20.561 22.779 23.425 27.061 Condenser pressure drop kpa 52 47 51,2 55,6 Total heat recovery Nominal capacity kw 158,9 175,4 181,6 209,7 Recovery condenser water l/s 7,59 8,38 8,67 10,01 flow l/h 27330 30168 31235 36068 Recovery condenser pressure drop kpa Compressors Type scroll Quantità n 2 2 4 4 Circuiti frigoriferi n 1 1 2 2 Absorbed power in cooling (*) kw 40 45,9 44,4 52 Absorbed power in heating (**) kw 40,5 44,4 46,8 55 Absorbed power in heat kw 39,1 43,1 44,4 52 recovery Capacity steps % 0-50-100 0-50-100 0-25-50-75 100 0-25-50-75 100 Fans Type Axial Total air flow m 3 /s 6,60 6,58 11,27 11,27 m 3 /h 23.760 23.700 40.560 40.560 Fan motor power n x kw 3 x 0,6 3 x 0,6 2 x 2,0 2 x 2,0 Revolution speed RPM 860 Fan power supply V/ph/Hz 230/~/50 400/3~/50 Refrigerant charge Version 4T kg 1 x 32 1 x 32 2 x 19,5 2 x 21 Version 2T kg 1 x 36 1 x 36 2 x 22 2 x 23 Oil Charge l 2 x 8 2 x 8 4 x 4 4 x 6,6 Brand Maneurop Type 160 SZ Evaporator Type Plates Water volume l 8,4 9,4 5,2 4,8 Max operating pressure water bar 30 side Length mm 3.234 3.234 3.234 3.234 Width mm 1.144 1.144 1.119 1.119 Heigth mm 1.740 1.740 2.380 2.380 Operating weight kg 1.124 1,158 1.400 1.464 (*) ambient air temperature 35 C; evaporator entering/leaving water temperature 12-7 C (**) ambient air temperature 8 C DB, 70%RH; condenser entering/leaving water temperature 40-45 C Blue Box 10

TECHNICAL DATA - OMICRON Refrigerant R4O7C OMICRON 18.4 20.4 24.4 26.4 Cooling (*) Nominal capacity kw 185,8 211 235,8 260,7 Evaporator water flow l/s 8,88 10,08 11,27 12,45 l/h 31.965 36.296 40.565 44.834 Evaporator pressure drop kpa 62 63,8 71,1 70,6 Heating (**) Nominal capacity kw 185,3 213,3 239,1 264,9 Condenser water flow l/s 8,85 10,19 11,42 12,66 l/h 31.873 69.686 41.122 45.558 Condenser pressure drop kpa 61,6 65,1 73 72,8 Total heat recovery Nominal capacity kw 247,3 284,8 317,8 350,7 Recovery condenser water l/s 11,8 13,6 15,18 16,7 flow l/h 42535,6 48985,6 54611,6 60320,4 Recovery condenser pressure drop kpa 28 27 30 29 Compresores Type scroll Quantità n 4 4 4 4 Circuiti frigoriferi n 2 2 2 2 Absorbed power in cooling (*) kw 61,2 72 80 88,1 Absorbed power in heating (**) kw 64,2 73,3 81,1 88,8 Absorbed power in heat kw 61,2 70,4 78,3 86,1 recovery Capacity steps % 0-25-50-75 100 0-25-50-75 100 0-25-50-75 100 0-25-50-75 100 Fans Type Axial Total air flow m 3 /s 16,38 16,42 19,39 18,50 m 3 /h 58.950 59.100 69.800 66.600 Fan motor power n x kw 3 x 2,0 3 x 2,0 4 x 2,0 4 x 2,0 Revolution speed RPM 860 Fan power supply V/ph/Hz 400/3~/50 Refrigerant charge Version 4T kg 2 x 27 2 x 27 2 x 26 2 x 31,5 Version 2T kg 2 x 30 2 x 30 2 x 30 2 x 35 Oil Charge l 2 x 8 + 2 x 6,6 4 x 8 4 x 8 4 x 8 Brand Maneurop Type 160 SZ Evaporator Type Plates Water volume l 6,3 7,3 8,4 9,4 Max operating pressure water bar 30 side Length mm 4.234 4.234 4.234 4.234 Width mm 1.119 1.119 1.119 1.119 Heigth mm 2.380 2.380 2.380 2.380 Operating weight kg 1.930 2.089 2.208 2.349 (*) ambient air temperature 35 C; evaporator entering/leaving water temperature 12-7 C (**) ambient air temperature 8 C DB, 70%RH; condenser entering/leaving water temperature 40-45 C Blue Box 11

ELECTRICAL CHARACTERISTICS Refrigerant R407C OMICRON 3.2 4.2 5.2 6.2 Maximum absorbed power (1) kw 17,6 20,6 25,6 28,5 kw (18,1) (21,1) (26,1) (29,6) Maximum starting current A 120,4 155,4 150,4 205,4 A (122,1) (157,1) (152,1) (208,3) Maximum absorbed current (2) A 39,4 45,4 55,4 65,4 A (41,1) (47,1) (57,1) (68,3) Fan nominal power n x kw 2 x 0,6 2 x 0,6 2 x 0,6 2 x 0,6 Fan nominal current n x A 2 x 2,7 2 x 2,7 2 x 2,7 2 x 2,7 Pump nominal power n x kw (1 x 0,5) (1 x 0,5) (1 x 0,5) (1 x 1,1) Pump nominal current n x A (1 x 1,7) (1 x 1,7) (1 x 1,7) (1 x 2,9) Power supply V/ph/Hz 400V 3 ~ 50Hz ±5% V Control power supply V/ph/Hz 230V 1 ~ 50Hz ±5% V Control circuit supply V/ph/Hz 24V ~ 50Hz Fans supply V/ph/Hz 230V/ ~ /50Hz Pump supply V/ph/Hz 400V/3 ~ /50 OMICRON 7.2 8.2 9.2 10.2 Maximum absorbed power (1) kw 31,4 37,4 43,2 48,4 kw (32,5) (38,5) (44,7) (49,9) Maximum starting current A 215,4 215,4 258,1 273,1 A (218,3) (218,3) (262,4) (277,4) Maximum absorbed current (2) A 75,4 75,4 93,1 108,1 A (78,3) (78,3) (97,4) (112,4) Fan nominal power n x kw 2 x 0,6 2 x 0,6 3 x 0,6 3 x 0,6 Fan nominal current n x A 2 x 2,7 2 x 2,7 3 x 2,7 3 x 2,7 Pump nominal power n x kw (1 x 1,1) (1 x 1,1) (1 x 1,5) (1 x 1,5) Pump nominal current n x A (1 x 2,9) (1 x 2,9) (1 x 4,3) (1 x 4,3) Power supply V/ph/Hz 400V 3 ~ 50Hz ±5% V Control power supply V/ph/Hz 230V 1 ~ 50Hz ±5% V Control circuit supply V/ph/Hz 24V ~ 50Hz Fans supply V/ph/Hz 230V/ ~ /50Hz Pump supply V/ph/Hz 400V/3 ~ /50 (1) mains power supply to allow unit operation. (2) maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). All values in brackets are refer to /ST version (units with storage tank) or units with pump. Blue Box 12

ELECTRICAL CHARACTERISTICS Refrigerant R407C OMICRON 12.2 13.2 14.4 16.4 Maximum absorbed power (1) kw 53,4 58,4 64,4 76,4 kw (55,6) (60,6) (66,6) (78,6) Maximum starting current A 328,1 347,1 288 288 A (333,4) (352,4) (293,3) (293,3) Maximum absorbed current (2) A 127,1 146,1 148 148 A (132,4) (151,4) (153,3) (153,3) Fan nominal power n x kw 3 x 0,6 3 x 0,6 2 x 2,0 2 x 2,0 Fan nominal current n x A 3 x 2,7 3 x 2,7 2 x 4,0 2 x 4,0 Pump nominal power n x kw (1 x 2,2) (1 x 2,2) (1 x 2,2) (1 x 2,2) Pump nominal current n x A (1 x 5,3) (1 x 5,3) (1 x 5,3) (1 x 5,3) Power supply V/ph/Hz 400V 3 ~ 50Hz ±5% V Control power supply V/ph/Hz 230V 1 ~ 50Hz ±5% V Control circuit supply V/ph/Hz 24V ~ 50Hz Fans supply V/ph/Hz 230V/ ~ /50Hz 400V/3 ~ /50 Pump supply V/ph/Hz 400V/3 ~ /50 OMICRON 18.4 20.4 24.4 26.4 Maximum absorbed power (1) kw 88,8 99,2 111,2 121,2 kw (92,8) (103,2) (115,2) (126,7) Maximum starting current A 347 377 455 493 A (36,5) (386,5) (464,5) (505) Maximum absorbed current (2) A 182 212 254 292 A (191,5) (221,5) (263,5) (304) Fan nominal power n x kw 3 x 2,0 3 x 2,0 4 x 2,0 4 x 2,0 Fan nominal current n x A 3 x 4,0 3 x 4,0 4 x 4,0 4 x 4,0 Pump nominal power n x kw (1 x 4,0) (1 x 4,0) (1 x 4,0) (1 x 5,5) Pump nominal current n x A (1 x 9,5) (1 x 9,5) (1 x 9,5) (1 x 12,0) Power supply V/ph/Hz 400V 3 ~ 50Hz ±5% V Control power supply V/ph/Hz 230V/~/50 Control circuit supply V/ph/Hz 24V ~ 50Hz Fans supply V/ph/Hz 400V/3 ~ /50 Pump supply V/ph/Hz 400V/3 ~ /50 (1) mains power supply to allow unit operation. (2) maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). All values in brackets are refer to /ST version (units with storage tank) or units with pump. Blue Box 13

VERSION WITH STORAGE TANK Refrigerant R407C OMICRON 3.2 4.2 5.2 6.2 Pump section Evaporator water flow l/s 1,77 2,13 2,45 2,88 l/h 6.377 7.682 8.833 10.379 Pump nominal power kw 0,5 0,5 0,5 1,1 Static available pressure kpa 117 103 96 139 Storage tank volume l 200 200 200 200 Length mm 2.233 2.233 2.233 2.233 Width mm 1.043 1.043 1.043 1.043 Heigth mm 1.740 1.740 1.740 1.740 Operating weight kg 724 734 755 807 OMICRON 7.2 8.2 9.2 10.2 Pump section Evaporator water flow l/s 3,23 3,71 4,37 4,89 l/h 11.608 13.347 15.748 17.611 Pump nominal power kw 1,1 1,1 1,5 1,5 Static available pressure kpa 134 112 122 109 Storage tank volume l 200 200 450 450 Length mm 2.233 2.233 3.234 3.234 Width mm 1.043 1.043 1.144 1.144 Heigth mm 1.740 1.740 1.740 1.740 Operating weight kg 825 868 1.142 1.219 OMICRON 12.2 13.2 14.4 16.4 Pump section Evaporator water flow l/s 5,63 6,05 6,55 7,53 l/h 20.283 21.780 23.567 27.103 Pump nominal power kw 2,2 2,2 2,2 2,2 Static available pressure kpa 115 110 134 96 Storage tank volume l 450 450 340 340 Length mm 3.234 3.234 3.234 3.234 Width mm 1.144 1.144 1.119 1.119 Heigth mm 1.740 1.740 2.380 2.380 Operating weight kg 1.275 1.309 1.642 1.678 OMICRON 18.4 20.4 24.4 26.4 Pump section Evaporator water flow l/s 8,88 10,8 11,27 12,45 l/h 31.965 36.296 40.565 44.834 Pump nominal power kw 4 4 4 5,5 Static available pressure kpa 138 124 101 159 Storage tank volume l 700 700 700 700 Length mm 5.234 5.234 5.234 5.234 Width mm 1.119 1.119 1.119 1.119 Heigth mm 2.380 2.380 2.380 2.380 Operating weight kg 2.290 2.449 2.622 2.749 Blue Box 14

OMICRON - SOUND POWER AND PRESSURE LEVELS STANDARD UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 96,1 78,8 87,3 70,0 81,2 63,8 79,7 62,4 78,6 61,3 73,2 55,9 69,8 52,4 60,7 43,4 83,0 65,7 4.2 96,5 79,1 87,7 70,3 81,5 64,2 80,0 62,7 78,9 61,6 73,6 56,2 70,1 52,8 61,0 43,7 83,3 66,0 5.2 96,6 79,2 87,8 70,4 81,6 64,3 80,1 62,8 79,0 61,7 73,7 56,3 70,2 52,9 61,1 43,8 83,4 66,1 6.2 97,3 79,9 88,5 71,1 82,3 65,0 80,8 63,5 79,7 62,4 74,4 57,0 70,9 53,6 61,8 44,5 84,1 66,8 7.2 97,5 80,1 88,7 71,3 82,5 65,2 81,0 63,7 79,9 62,6 74,6 57,2 71,1 53,8 62,0 44,7 84,3 67,0 8.2 98,1 80,8 89,3 72,0 83,2 65,8 81,7 64,4 80,6 63,2 75,2 57,9 71,8 54,4 62,7 45,3 85,0 67,7 9.2 99,7 81,8 90,9 73,0 84,8 66,8 83,3 65,4 82,2 64,2 76,9 58,9 73,4 55,4 64,3 46,3 86,6 68,7 10.2 100,0 82,0 91,2 73,2 85,0 67,0 83,5 65,6 82,4 64,5 77,1 59,1 73,6 55,6 64,5 46,6 86,8 68,9 12.2 100,1 82,2 91,3 73,4 85,1 67,3 83,7 65,8 82,6 64,7 77,2 59,3 73,7 55,9 64,7 46,8 87,0 69,1 13.2 100,3 82,3 91,5 73,5 85,3 67,3 83,8 65,9 82,7 64,8 77,4 59,4 73,9 55,9 64,8 46,9 87,1 69,2 14.4 101,1 82,5 92,3 73,7 86,1 67,5 84,6 66,0 83,5 64,9 78,2 59,6 74,7 56,1 85,6 47,0 87,9 69,3 16.4 103,6 85,0 94,8 76,2 88,6 70,1 87,2 68,6 96,1 67,5 80,7 62,1 77,2 58,7 68,2 49,6 90,5 71,9 18.4 104,5 85,4 95,7 76,6 89,6 70,5 88,1 69,0 87,0 67,9 81,6 62,5 78,2 59,1 69,1 50,0 91,4 72,3 20.4 105,2 86,1 96,4 77,3 90,3 71,2 88,8 69,7 87,7 68,6 82,3 63,2 78,9 59,8 69,8 50,7 92,1 73,0 24.4 106,1 87,0 97,3 78,2 91,2 72,1 89,7 70,6 88,6 69,5 83,2 64,1 79,8 60,7 70,7 51,6 93,0 73,9 26.4 106,2 87,1 97,4 78,3 91,3 72,2 89,8 70,7 88,7 69,6 83,3 64,2 79,9 60,8 70,8 51,7 93,1 74,0 LOW NOISE UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 93,4 76,0 84,6 67,2 78,4 61,1 76,9 59,6 75,8 58,5 70,5 53,1 67,0 49,7 57,9 40,6 80,2 62,9 4.2 93,5 76,2 84,7 67,4 78,5 61,3 77,0 59,8 75,9 58,7 70,6 53,3 67,1 49,9 58,0 40,8 80,3 63,1 5.2 93,7 76,4 84,9 67,6 78,7 61,5 77,2 60,0 76,1 58,9 70,8 53,5 67,3 50,1 58,2 41,0 80,5 63,3 6.2 94,3 77,0 85,5 68,2 79,3 62,1 77,8 60,6 76,7 59,5 71,4 54,1 67,9 50,7 58,8 41,6 81,1 63,9 7.2 94,4 77,1 85,6 68,3 79,4 62,2 77,9 60,7 76,8 59,6 71,5 54,2 68,0 50,8 58,9 41,7 81,2 64,0 8.2 96,3 79,0 87,5 70,2 81,3 64,1 79,8 62,6 78,7 61,5 73,4 56,1 69,9 52,7 60,8 43,6 83,1 65,9 9.2 97,3 79,0 88,5 70,6 82,3 64,5 80,9 63,0 79,8 61,9 74,4 56,5 70,9 53,1 61,9 44,0 84,2 66,3 10.2 97,8 79,5 89,0 71,1 82,8 65,0 81,4 63,5 80,3 62,4 74,9 57,0 71,4 53,6 62,4 44,5 84,7 66,8 12.2 97,3 79,0 88,5 70,6 82,3 64,5 80,9 63,0 79,8 61,9 74,4 56,5 70,9 53,1 61,9 44,0 84,2 66,3 13.2 97,6 79,3 88,8 70,9 82,6 64,8 81,2 63,3 80,1 62,2 74,7 56,8 71,2 53,4 62,2 44,3 84,5 66,6 14.4 99,1 80,5 90,3 71,7 54,1 65,5 82,6 64,0 81,5 62,9 76,2 57,6 72,7 54,1 63,6 45,0 85,9 67,3 16.4 101,8 82,6 93,0 74,4 96,8 68,3 85,4 66,8 84,3 65,7 78,9 60,3 75,4 56,9 66,4 47,8 88,7 70,1 18.4 102,6 82,7 93,8 74,7 87,7 68,6 86,2 67,1 85,1 66,0 79,7 60,6 76,3 57,2 67,2 48,1 89,5 70,4 20.4 103,0 83,1 94,2 75,1 88,1 69,0 86,6 67,5 85,5 66,4 80,1 61,0 76,7 57,6 67,6 48,5 89,9 70,8 24.4 103,9 84,0 95,1 76,0 89,0 69,9 87,5 68,4 86,4 67,3 81,0 61,9 77,6 58,5 68,5 49,4 90,8 71,7 26.4 104,0 84,1 95,2 76,1 89,1 70,0 87,6 68,5 86,5 67,4 81,1 62,0 77,7 58,6 68,6 49,5 90,9 71,8 Lw: sound power values in free field conditions are calculated in accordance with ISO 3744. Lp : sound pressure values measured at 1 m from the unit in free field conditions in compliance with ISO 3744 Blue Box 15

OMICRON - SOUND POWER AND PRESSURE LEVELS SUPER LOW NOISE UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 90,2 73,0 81,4 64,2 75,3 58,1 73,8 56,6 72,7 55,5 67,3 50,1 63,9 46,7 54,8 37,6 77,1 59,9 4.2 90,6 73,5 81,8 64,7 75,7 58,6 74,2 57,1 73,1 56,0 67,7 50,6 64,3 47,2 55,2 38,1 77,5 60,4 5.2 91,1 73,9 82,3 65,1 76,2 59,0 74,7 57,5 73,6 56,4 68,2 51,0 64,8 47,6 55,7 38,5 78,0 60,8 6.2 91,8 74,6 83,0 65,8 76,9 59,7 75,4 58,2 74,3 57,1 68,9 51,7 65,5 48,3 56,4 39,2 78,7 61,5 7.2 92,1 74,9 83,3 66,1 77,2 60,0 75,7 58,5 74,6 57,4 69,2 52,0 65,8 48,6 56,7 39,5 79,0 61,8 8.2 94,8 76,8 86,0 68,0 79,9 61,9 78,4 60,4 77,3 59,3 71,9 53,9 68,5 50,5 59,4 41,4 81,7 63,7 9.2 95,0 77,1 86,2 68,3 80,1 62,2 78,6 60,7 77,5 59,6 72,1 54,2 68,7 50,8 59,6 41,7 81,9 64,0 10.2 95,7 77,8 86,9 69,0 80,8 62,9 79,3 61,4 78,2 60,3 72,8 54,9 69,4 51,5 60,3 42,4 82,6 64,7 12.2 95,3 77,4 86,5 68,6 80,4 62,5 78,9 61,0 77,8 59,9 72,4 54,5 69,0 51,1 59,9 42,0 82,2 64,3 13.2 95,6 77,7 86,8 68,9 80,7 62,8 79,2 61,3 78,1 60,2 72,7 54,8 69,3 51,4 60,2 42,3 82,5 64,6 14.4 97,1 78,1 88,3 69,3 82,1 63,1 80,6 61,6 79,5 60,5 74,2 55,2 70,7 51,7 61,6 42,6 83,5 64,9 16.4 99,6 81,0 90,8 72,2 84,7 66,1 83,2 64,6 82,1 63,5 76,7 58,1 73,3 54,7 64,2 45,6 86,5 67,9 18.4 100,1 80,9 91,3 72,1 85,2 66,0 83,7 64,5 82,6 63,4 77,2 58,0 73,8 54,6 64,7 45,5 87,0 67,8 20.4 100,7 81,5 91,9 72,7 85,8 66,6 84,3 65,1 83,2 64,0 77,8 58,6 74,4 55,2 65,3 46,1 87,6 68,4 24.4 101,6 82,5 92,8 73,7 86,7 67,6 85,2 66,1 84,1 65,0 78,7 59,6 75,3 56,2 66,2 47,1 88,5 69,4 26.4 102,3 82,7 93,5 73,9 87,4 67,8 85,9 66,3 84,8 65,2 79,4 59,8 76,0 56,4 66,9 47,3 89,2 69,6 Lw: sound power values in free field conditions are calculated in accordance with ISO 3744. Lp : sound pressure values measured at 1 m from the unit in free field conditions in compliance with ISO 3744 Blue Box 16

TECHNICAL DATA - OMICRON /CF WITH CENFRIFUGAL FANS Refrigerant R4O7C OMICRON /CF 3.2 4.2 5.2 6.2 Fans Type Centifugal Total air flow m 3 /s 5,28 5,28 5,28 5,83 m 3 /s 19.000 19.000 19.000 21.000 Static available pressure Pa 50 50 50 50 Fan motor power n x kw 2 x 1,5 2 x 1,5 2 x 1,5 2 x 2,2 Revolution speed RPM 627 628 628 671 Fan power supply V/Ph/Hz 400/3 ~ /50 Length mm 2.233 2.233 2.233 2.233 Width mm 1.043 1.043 1.043 1.043 Heigth mm 1.630 1.630 1.630 1.630 Operating weight kg 670 680 701 748 OMICRON /CF 7.2 8.2 9.2 10.2 Fans Type Centifugal Total air flow m 3 /s 5,83 6,11 8,33 8,33 m 3 /s 21.000 22.000 30.000 30.000 Static available pressure Pa 50 50 50 50 Fan motor power n x kw 2 x 2,2 2 x 2,2 3 x 2,2 3 x 2,2 Revolution speed RPM 672 712 639 639 Fan power supply V/Ph/Hz 400/3 ~ /50 Length mm 2.233 2.233 3.234 3.234 Width mm 1.043 1.043 1.144 1.144 Heigth mm 1.630 1.630 1.630 1.630 Operating weight kg 766 813 1.096 1.173 OMICRON /CF 12.2 13.2 14.4 16.4 Fans Type Centifugal Total air flow m 3 /s 8,33 8,33 10,00 13,33 m 3 /s 30.000 30.000 36.000 48.000 Static available pressure Pa 50 50 50 50 Fan motor power n x kw 3 x 2,2 3 x 2,2 2 x 4,0 3 x 3,0 Revolution speed RPM 660 660 644 611 Fan power supply V/Ph/Hz 400/3 ~ /50 Length mm 3.234 3.234 3.234 3.234 Width mm 1.144 1.144 1.119 1.119 Heigth mm 1.630 1.630 2.130 2.130 Operating weight kg 1.238 1.273 1.441 1.575 OMICRON /CF 18.4 20.4 24.4 26.4 Fans Type Centifugal Total air flow m 3 /s 15,83 19,44 19,44 18,50 m 3 /s 57.000 70.000 70.000 66.600 Static available pressure Pa 50 50 50 50 Fan motor power n x kw 3 x 4,0 4 x 4,0 4 x 4,0 4 x 4,0 Revolution speed RPM 667 656 656 646 Fan power supply V/Ph/Hz 400/3 ~ /50 Length mm 4.234 4.234 4.234 4.234 Width mm 1.119 1.119 1.119 1.119 Heigth mm 2.130 2.130 2.130 2.130 Operating weight kg 1.894 2.182 2.301 2.442 Blue Box 17

OMICRON /CF - ELECTRICAL CHARACTERISTICS Refrigerant R407C OMICRON/CF 3.2 4.2 5.2 6.2 7.2 8.2 Maximum absorbed power (1) kw 19,4 22,4 27,4 31,7 34,6 40,6 kw (19,9) (22,9) (27,9) (32,8) (35,7) (41,7) Maximum starting current A 122,2 157,2 152,2 210,2 220,2 220,2 A (123,9) (158,9) (153,9) (213,1) (223,1) (223,1) Maximum absorbed current (2) A 41,2 47,2 57,2 70,2 80,2 80,2 A (42,9) (48,9) (58,9) (73,1) (83,1) (83,1) Fan nominal power n x kw 2 x 1,5 2 x 1,5 2 x 1,5 2 x 2,2 2 x 2,2 2 x 2,2 Corriente nominal motor vent. n x A 2 x 3,6 2 x 3,6 2 x 3,6 2 x 5,1 2 x 5,1 2 x 5,1 Pump nominal power n x kw (1 x 0,5) (1 x 0,5) (1 x 0,5) (1 x 1,1) (1 x 1,1) (1 x 1,1) Pump nominal current n x A (1 x 1,7) (1 x 1,7) (1 x 1,7) (1 x 2,9) (1 x 2,9) (1 x 2,9) OMICRON/CF 9.2 10.2 12.2 13.2 14.4 Maximum absorbed power (1) kw 48 53,2 58,2 63,2 68,4 kw (49,5) (54,7) (60,4) (65,4) (70,6) Maximum starting current A 265,3 280,3 335,3 354,3 298 A (269,6) (284,6) (340,6) (359,6) (303,3) Maximum absorbed current (2) A 100,3 115,3 134,3 153,3 158 A (104,6) (119,6) (139,6) (158,6) (163,3) Fan nominal power n x kw 3 x 2,2 3 x 2,2 3 x 2,2 3 x 2,2 2 x 4,0 Corriente nominal motor vent. n x A 3 x 5,1 3 x 5,1 3 x 5,1 3 x 5,1 2 x 9,0 Pump nominal power n x kw (1 x 1,5) (1 x 1,5) (1 x 2,2) (1 x 2,2) (1 x 2,2) Pump nominal current n x A (1 x 4,3) (1 x 4,3) (1 x 5,3) (1 x 5,3) (1 x 5,3) OMICRON/CF 16.4 18.4 20.4 24.4 26.4 Maximum absorbed power (1) kw 81,4 94,8 109,2 119,2 129,2 kw (83,6) (98,8) (113,2) (123,2) (134,7) Maximum starting current A 301,3 362 401 475 513 A (306,6) (371,5) (410,5) (484,5) (525) Maximum absorbed current (2) A 161,3 362 401 475 513 A (166,6) (206,5) (245,5) (283,5) (324) Fan nominal power n x kw 3 x 3,0 4 x 3,0 4 x 3,0 4 x 3,0 4 x 3,0 Corriente nominal motor vent. n x A 3 x 7,1 4 x 9,0 4 x 9,0 4 x 9,0 4 x 9,0 Pump nominal power n x kw (1 x 2,2) (1 x 4,0) (1 x 4,0) (1 x 4,0) (1 x 5,5) Pump nominal current n x A (1 x 5,3) (1 x 9,5) (1 x 9,5) (1 x 9,5) (1 x 12,0) OMICRON/CF Power supply V/ph/Hz 400V 3N ~ 50Hz ± 5% V Control power supply V/ph/Hz 230/ ~ /50 Control circuit supply V/ph/Hz 24V ~ 50Hz Fans supply V/ph/Hz 400V/3 ~ 50Hz Pump supply V/ph/Hz 400V/3 ~ 50 (1) mains power supply to allow unit operation. (2) maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). All values in brackets are refer to /ST version (units with storage tank) or units with pump. Blue Box 18

OMICRON/CF - VERSION WITH STORAGE TANK Refrigerant R407C OMICRON /CF 3.2 4.2 5.2 6.2 Pump section Evaporator water flow l/s 1,77 2,13 2,45 2,88 l/h 6.377 7.682 8.833 10.379 Pump nominal power kw 0,5 0,5 0,5 1,1 Static available pressure kpa 117 103 96 139 Storage tank volume l 200 200 200 200 Length mm 2.233 2.233 2.233 2.233 Width mm 1.043 1.043 1.043 1.043 Heigth mm 1.630 1.630 1.630 1.630 Operating weight kg 800 810 831 883 OMICRON /CF 7.2 8.2 9.2 10.2 Pump section Evaporator water flow l/s 3,23 3,71 4,37 4,89 l/h 11.608 13.347 15.748 17.611 Pump nominal power kw 1,1 1,1 1,5 1,5 Static available pressure kpa 134 112 122 109 Storage tank volume l 200 200 450 450 Length mm 2.233 2.233 3.234 3.234 Width mm 1.043 1.043 1.144 1.144 Heigth mm 1.630 1.630 1.630 1.630 Operating weight kg 901 944 1.257 1.334 OMICRON /CF 12.2 13.2 14.4 16.4 Pump section Evaporator water flow l/s 5,63 6,05 6,55 7,53 l/h 20.283 21.780 23.567 27.103 Pump nominal power kw 2,2 2,2 2,2 2,2 Static available pressure kpa 115 110 134 96 Storage tank volume l 450 450 340 340 Length mm 3.234 3.234 3.234 4.234 Width mm 1.144 1.144 1.119 1.119 Heigth mm 1.630 1.630 2.130 2.130 Operating weight kg 1.389 1.424 1.677 1.898 OMICRON /CF 18.4 20.4 24.4 26.4 Pump section Evaporator water flow l/s 8,88 10,8 11,27 12,45 l/h 31.965 36.296 40.565 44.834 Pump nominal power kw 4 4 4 5,5 Static available pressure kpa 138 124 101 159 Storage tank volume l 700 700 700 700 Length mm 5.234 5.234 5.234 5.234 Width mm 1.119 1.119 1.119 1.119 Heigth mm 2.130 2.130 2.130 2.130 Operating weight kg 2.304 2.449 2.568 2.749 Blue Box 19

OMICRON /CF - SOUND POWER AND PRESSURE LEVELS STANDARD UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total /CF db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 96,7 79,7 89,3 72,3 85,4 68,3 85,6 68,6 82,2 65,2 79,3 62,3 90,1 63,0 76,7 59,7 88,4 71,4 4.2 97,1 80,1 89,7 72,7 85,7 68,8 85,9 69,0 82,5 65,6 79,7 62,7 80,4 63,5 77,0 60,1 88,8 71,8 5.2 97,2 80,2 89,8 72,8 85,8 68,9 86,0 69,1 82,6 65,7 79,8 62,8 80,5 63,6 77,1 60,2 88,9 71,9 6.2 97,7 80,7 89,9 72,9 86,3 69,4 86,1 69,2 83,2 66,3 80,0 63,0 81,6 64,7 78,1 61,2 89,4 72,4 7.2 97,8 80,8 90,3 73,3 86,4 69,5 86,3 69,4 83,0 66,1 80,3 63,3 81,9 65,0 78,6 61,7 89,6 72,6 8.2 98,9 81,9 93,9 76,9 86,6 69,5 87,9 70,9 84,5 67,5 79,6 62,6 83,3 66,2 7,4 60,3 90,6 73,6 9.2 100,3 82,6 98,9 81,3 87,0 69,3 88,4 70,7 85,9 68,2 80,9 63,2 84,7 67,0 78,8 61,1 92,0 74,3 10.2 99,9 82,2 99,5 81,8 86,5 68,8 88,6 70,9 85,9 68,2 81,0 63,3 84,6 66,9 77,5 59,9 92,1 74,4 12.2 101,2 83,5 97,9 80,2 87,1 69,5 88,3 70,6 86,4 68,7 83,1 65,4 85,8 68,2 81,0 63,3 92,7 75,0 13.2 101,4 83,7 98,1 80,4 87,3 69,6 88,4 70,8 86,5 68,9 83,3 65,6 86,0 68,3 81,1 63,5 92,9 75,2 14.4 100,6 82,2 92,9 74,5 88,8 70,4 89,2 70,8 86,8 68,4 83,9 65,5 85,0 66,6 81,4 63,0 92,7 74,4 16.4 102,8 84,5 95,4 77,1 91,4 73,1 91,6 73,4 88,2 70,0 85,4 67,1 86,1 67,8 82,7 64,5 94,5 76,2 18.4 103,6 85,3 96,2 77,9 92,2 73,9 92,5 74,2 89,1 70,8 86,2 67,9 86,9 68,6 83,6 65,3 95,3 77,0 20.4 105,1 86,8 97,7 79,4 93,7 75,4 94,0 75,7 90,6 72,3 87,7 69,4 88,4 70,1 85,1 66,8 96,8 78,5 24.4 105,1 86,8 97,7 79,4 93,7 75,4 94,0 75,7 90,6 72,3 87,7 69,4 88,4 70,1 85,1 66,8 96,8 78,5 26.4 105,2 86,9 97,8 79,5 93,8 75,5 94,1 75,8 90,7 72,4 87,8 69,5 88,5 70,2 85,2 66,9 96,9 78,6 LOW NOISE UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total /CF db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 94,2 77,2 86,7 69,6 83,0 66,0 83,2 66,2 79,9 62,8 76,5 59,5 77,3 60,2 74,5 57,5 58,9 68,9 4.2 94,6 77,6 87,0 69,9 83,7 66,6 83,9 66,8 80,3 63,2 76,8 59,8 78,0 61,0 74,6 57,6 86,4 69,4 5.2 94,3 77,3 87,4 70,4 83,0 66,1 83,7 66,8 79,8 62,8 77,3 60,3 77,9 61,0 74,2 57,3 86,3 69,3 6.2 95,6 78,6 87,0 70,1 83,6 66,7 84,1 67,2 80,8 63,8 77,0 60,1 78,8 61,8 75,3 58,3 86,9 69,9 7.2 95,4 78,4 88,1 71,0 84,1 67,0 83,8 66,8 80,1 63,0 78,3 61,2 79,0 61,9 76,0 59,0 86,9 69,9 8.2 96,4 79,5 91,8 74,9 83,7 66,8 85,0 68,0 81,7 64,7 77,0 60,1 80,6 63,7 74,4 57,5 87,9 70,9 9.2 98,2 80,4 96,6 78,8 84,9 67,2 85,6 67,8 83,7 65,9 78,0 60,3 82,6 64,8 76,6 58,8 89,7 71,9 10.2 97,4 79,6 96,9 79,1 84,2 66,3 86,0 68,1 82,9 65,1 78,4 60,5 81,7 63,8 75,0 57,1 89,3 71,5 12.2 98,7 80,9 95,5 77,7 85,0 67,2 86,1 68,4 84,0 66,2 80,1 62,3 83,1 65,3 78,2 60,4 90,2 72,4 13.2 98,5 80,7 95,8 78,1 84,7 66,9 86,3 68,5 83,6 65,8 80,7 65,3 83,0 67,9 78,2 60,4 90,2 72,4 14.4 97,8 79,5 90,2 71,9 86,3 68,1 87,1 68,9 84,6 66,4 81,0 62,8 82,1 63,8 78,7 60,5 90,3 72,0 16.4 100,4 82,1 93,0 74,7 89,0 70,7 89,2 71,0 85,8 67,6 83,0 64,7 83,7 65,4 80,3 62,1 92,1 73,8 18.4 101,3 82,4 93,9 75,0 89,9 71,0 90,2 71,3 86,8 67,9 83,9 65,0 84,6 65,7 81,3 62,4 93,0 74,1 20.4 102,9 83,0 95,5 75,6 91,5 71,6 91,8 71,9 88,4 68,5 85,5 65,6 86,2 66,3 82,9 63,0 94,6 74,7 24.4 103,0 83,1 95,6 75,7 91,6 71,7 91,9 72,0 88,5 68,6 85,6 65,7 86,3 66,4 83,0 63,1 94,7 74,8 26.4 103,0 83,1 95,6 75,7 91,6 71,7 91,9 72,0 88,5 68,6 85,6 65,7 86,3 66,4 83,0 63,1 94,7 74,8 Lw: sound power values in free field conditions are calculated in accordance with ISO 3744. Lp : sound pressure values measured at 1 m from the unit in free field conditions in compliance with ISO 3744 Blue Box 20

OMICRON /CF - SOUND POWER AND PRESSURE LEVELS SUPER LOW NOISE UNITS Octave band [Hz] OMICRON 63 125 250 500 1000 2000 4000 8000 Total /CF db db db db db db db db db(a) Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp Lw Lp 3.2 92,0 74,9 84,4 67,3 80,8 63,7 81,0 63,9 77,6 60,5 74,3 57,2 75,0 57,9 72,3 55,2 83,7 66,6 4.2 92,5 75,4 84,9 67,8 81,3 64,2 81,5 64,4 78,1 61,0 74,8 57,7 75,5 58,4 72,8 55,7 84,2 67,1 5.2 92,4 75,3 84,8 67,7 81,2 64,1 81,4 64,3 78,0 60,9 74,7 57,6 75,4 58,3 72,7 55,6 84,1 67,0 6.2 93,1 75,9 85,5 68,3 81,9 64,7 82,1 64,9 78,7 61,5 75,4 58,2 76,1 58,9 73,4 56,2 84,8 67,6 7.2 93,1 75,9 85,5 68,3 81,9 64,7 82,1 64,9 78,7 61,5 75,4 58,2 76,1 58,9 73,4 56,2 84,8 67,6 8.2 95,1 7702 87,5 69,6 83,9 66,0 84,1 66,2 80,7 62,8 77,4 59,5 78,1 60,2 75,4 57,5 86,8 68,9 9.2 96,0 78,1 88,4 70,5 84,8 66,9 85,0 67,1 81,6 63,7 78,3 60,4 79,0 61,1 76,3 58,4 87,7 69,8 10.2 95,5 77,5 87,9 69,9 84,3 66,3 84,5 66,5 81,1 63,1 77,8 59,8 78,5 60,5 75,8 57,8 87,2 69,2 12.2 96,8 78,9 89,2 71,3 85,6 67,7 85,8 67,9 82,4 64,5 79,1 61,2 79,8 61,9 77,1 59,2 88,5 70,6 13.2 96,8 78,9 89,2 71,3 85,6 67,7 85,8 67,9 82,4 64,5 79,1 61,2 79,8 61,9 77,1 59,2 88,5 70,6 14.4 96,8 78,9 89,2 70,6 85,6 67,0 85,8 67,2 82,4 63,8 79,1 60,5 79,8 61,2 77,1 58,5 88,5 69,9 16.4 98,6 80,0 91,0 72,4 87,4 68,8 87,6 69,0 84,2 65,6 80,9 62,3 81,6 63,0 78,9 60,3 90,3 71,7 18.4 99,5 80,4 91,9 72,8 88,3 69,2 88,5 69,4 85,1 66,0 81,8 62,7 82,5 63,4 79,8 60,7 91,2 72,1 20.4 100,1 80,9 92,5 73,3 88,9 69,7 89,1 69,9 85,7 66,5 82,4 63,2 83,1 63,9 80,4 61,2 91,8 72,6 24.4 100,2 81,0 92,6 73,4 89,0 69,8 89,2 70,0 85,8 66,6 82,5 63,3 83,2 64,0 80,5 61,3 91,9 72,7 26.4 100,8 81,1 93,2 73,5 89,6 69,9 89,8 70,1 86,4 66,7 83,1 63,4 83,8 64,1 81,1 61,4 92,5 72,8 Lw: sound power values in free field conditions are calculated in accordance with ISO 3744. Lp : sound pressure values measured at 1 m from the unit in free field conditions in compliance with ISO 3744 Blue Box 21