TMBU & SCBU CLEANING AND DISINFECTION POLICY

Similar documents
The individual indicated in the responsible person column must decontaminate the item as indicated in the method column.

Decontamination of Reusable Equipment - Standard Operating Procedure (A-Z Cleaning Guide)

Version date: April 2012 Updated: 17/06/15 Updated 16/12/2016. Approved by IPCC Oct 2015 Next Review date Oct 2018

APPENDIX J Decontamination of Medical Equipment, Fittings and Rooms A Z

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

DRAFT. Module 4. Decontamination & Environmental Cleaning

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Policy on Cleaning and Disinfection of Equipment, Surfaces, Environment and Skin

Housekeeping. Note. Areas that are not covered under contractor services must adhere to the same cleaning standards as specified in this section.

INFECTION PREVENTION AND CONTROL ENVIRONMENTAL AUDIT TOOL

Newcastle Hospital NHS Foundation Trust Control of Infection Committee Water Coolers and Ice-Making Machines Policy

Policy on Cleaning and Disinfection of Equipment, Surfaces, Environment and Skin

Policy on Cleaning and Disinfection of Equipment, Surfaces, Environment and Skin

4/8/2014 GOAL PATIENT EQUIPMENT

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

National Maternity Hospital. Founded in 1894

Redefining Healthcare Solutions

Cleaning & Care. Washing Breast Pump Parts

Infection Control Policy and Procedures

A basic introduction about the principles of humidity

Corporate. Laundry SOP. Document Control Summary

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

Always ensure that surfaces that are being disinfected are compatible with the product being used.

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Harvey Chemiclave 5000 Owner And Operator Guide

Environmental Cleaning Tool Kit

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Housekeeping and Laundry Ulrika Ransjö

Report Market survey: infant warming and phototherapy. January Health and social care working together

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Bipap A30/40 ventilator and System One humidifier

CleaningProtocol. Guidelines for Frontline Staff

The list is not exhaustive and where there is any doubt about the VAT status of items not included here please contact the UCL Tax Team.

Simple and Versatile

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Discharge and Transfer Cleaning - Isolation

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

M ECG MACHINES Digital 12 channel digital MAS 1112 M Meditech Spirometry SpirOx Digital single channel ECG machine MAS-1201G Spirometer MAS99 Digital

AUSTVET. April/May 2015 $2,900 $3,500 $3,900 $1,200 $1,500 $1,900

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

A Caregiver Guide for Tracheostomy Care at Home

INFECTION PREVENTION AND CONTROL MASTER EQUIPMENT CLEANING & DISINFECTING MANUAL

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

CHILDCARE SETTINGS. Childcare Settings

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Disposable Medical Pulp Containers

Jennings Street School

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Discharge and Transfer Cleaning

The Do's and Don ts in the Instrument Sterilisation Process

Staff can demonstrate how to access Infection Control policies. b. Staff can articulate the procedure for reportable diseases

PERFORM Operating Document

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

An MRI Centre An MRI centre shall be defined as a facility with the following minimum requirements as listed in sections A to G below:

UTILITY & PAN ROOM EQUIPMENT DDC SANITISERS & MACERATORS OPTIMISING INFECTION CONTROL

Cavitron Systems, Sterilizable Handpieces and Reservoir Bottles INFECTION CONTROL PROCEDURES

Dietary Department, Infection Control

KEY OPERATOR STUDY GUIDE

Guidance on Environmental Requirements for Minor Surgery in General Practice

Policy Document Control Page

OXYGEN CONCENTRATORS Information For Our Customers

I.F.U Re/Processing Reusable Medical Devices

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

Reusable Laryngoscope Blades and Handles

Babytherm 8000 OC Resuscitation/Open Care Unit. Instructions for Use

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Clean to go - the entire solution

Invacare Propad. General. Cushion User Manual. General information. Warranty. Standards and regulations. Symbols in this user manual.

HYGIENE, CLEANING AND INFECTION CONTROL POLICY


Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

Professional Design Project

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

Clean Kitchen Premises and Equipment

OPERATING INSTRUCTIONS & TROUBLESHOOTING GUIDE ECO MODELS FLUID WARMING CABINETS BLANKET WARMING CABINETS

Planning for the optimal sluice room

Cleaning Telemonitor & Accessories

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Home Medical Equipment Oxygen

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members

The Memorial Souad Kafafi Medical Center Skills Competency Checklist

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Caring for your Child with a Tracheostomy at home

NZX Australasian Media Day 12 November 2003

TLC-30 eco Intensive Care Unit / Brooder Operating Manual

The Lee Wiggins Childcare Centre ENVIRONMENTAL CLEANING AND DISINFECTING POLICY AND PROCEDURE

CLEANING AND SANITATION Policy Owner: Erica Tennessen Policy Originated by (program or department): Program Applicable Programs: All Programs

H4i. User Guide HEATED HUMIDIFIER. English

Holland Park Child Care Centre

Operating / User Manual

Cleaning & Sterilization

When you successfully complete the test, you will receive a certificate and a registered key ring. We look forward to hearing from you.

HEALTH AND HYGIENE POLICY

Tropic 2.0 ultrasonic nebuliser

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Octagon 20 Parrot Rearing Module

PIHA DUTIES HANDBOOK. 64 Glenesk Road, Piha

Transcription:

TMBU & SCBU CLEANING AND DISINFECTION POLICY This policy is to be used in conjunction with the Brighton and Sussex University Hospitals NHS Trust Infection Prevention & Control Decontamination Policy (see here) and must not be read as a stand alone document Further references: Brighton and Sussex University Hospitals. 2015. Cleaning and storage of breast milk collection sets (RB/Trevor Mann Baby Unit Guideline) Brighton and Sussex University Hospitals. 2015. Cleaning and sterilisation of pacifiers (WC/Trevor Mann Baby Unit Guideline) http://sterilus.com/about.html ( Steri-sac manufacturer instructions) Updated by: Rachel Burton (Infection Control Link Nurse) Judith Simpson (Infection Control Link Sister) Date: August 2015 Policy No: IC02 Review Date: August 2016 As agreed by: Andrew Davies Infection Prevention and Control Team

CLEANING AND DISINFECTION POLICY Clinell Universal Sanitising Wipes are effective against 99.999% of germs and they act as a disinfectant and detergent wipe for hands, surfaces and equipment. The wipes are not effective against spores so if there is a case of Clostridium difficile on the unit, Tristal or anti-sporicidal Clinell red wipes should be used for cleaning (obtain from Sodexo / stores). Please ensure that 60 seconds contact time is given for the wipes to work. If after this time the surface remains visibly damp, then the item can be dried with paper towels. Once the item is clean, complete and attach a green decontamination label and put into storage (larger items should be covered with a plastic sheet when in storage). When the item is in use, remove the green label. Follow the guidelines set out in this policy when cleaning equipment on the neonatal unit. Single-use equipment must only be used once and then disposed of. Single-patient-use equipment must only be used for one patient (but can be used more than once for that single patient). All reusable equipment must be cleaned in between patients to prevent cross infection from one baby to another.

Airways Single use. Dispose of after use. Ambubags Single patient use. Dispose of after use. Baby baths Baby / bed linen All dirty linen to be disposed of into laundry trolleys in the nurseries; these should be taken to the cot side rather than the linen to the trolley. Linen should be washed at a minimum temperature of 65 o C. Posey limb covers are disposable and should not be washed for reuse. Bassinet (plastic) covers Bilibed Dedicated sleep suit to be washed as per instructions for general baby linen. Bed to be cleaned with Clinell universal sanitising wipes. Bili blanket Blood warmer Bottles and teats In most cases, disposable bottles and teats are used and discarded immediately following use. When babies are using their own bottles, for example when nearing discharge or specialised squeezy bottles due to cleft palate, rinse the bottle and teat using hot soapy water and then sterilise using the Steri-sac (see manufacturer instructions). The reusable bottles and teats should be sterilised immediately prior to use due to lack of appropriate storage for sterilised items. Breast pump (humilactor) Cleaned every day by the HCAs with Clinell universal sanitising wipes. Breast pump accessories (including the filter) are single patient use. Please refer to Cleaning and storage of breast milk collection sets for further advice. Cerebral function monitor (CFM) Clean the outer case and cable with Clinell universal sanitising wipes.

Cots When in use, clean daily with Clinell universal sanitising wipes. After transfer / discharge, completely dismantle the cot and clean thoroughly with Clinell universal sanitising wipes. CPAP machines All tubing and humidity chamber are disposable and renewed every 7 days (remember to label the humidifier with the date that it is due to be changed). Clean machine with Clinell universal sanitising wipes. CPAP mask and prongs are single use. Hats and chin straps are single patient use and should be changed when visibly soiled Clipboards Dummies (pacifiers) Single patient use. Rinse with hot water and detergent and sterilise once a day using the Steri-sac (see manufacturer instructions); once sterilised, document on patient care plan. Store in closed plastic container if not in use. Feeding pumps (Neothrive) Clean daily and in between patient use. Clean using Clinell universal sanitising wipes paying particular attention to the grooves and recesses of the pump. Fibre optic light Gas calibration unit for the TCM Graseby apnoea monitors Probes are single patient use and are disposable. Clean monitor with Clinell universal sanitising wipes. Hot cots including gel mattress / Kanmed Babybed Heatshields HHFNC All tubing and humidity chamber are disposable and renewable every 7 days (remember a label should be attached to the chamber stating when the change is next due). Clean machine with Clinell universal sanitising wipes.

Prongs are single patient use. Dispose of after use. Humidifiers (on ventilators, CPAP or HHFNC) The wires are non-disposable and should be wiped thoroughly with Clinell universal sanitising wipes. The chamber is disposable and should be changed every 7 days and a label attached stating when the next change is due. Incubators Airshields Isolette T1500/500 (transport incubators); Ohmeda Giraffe and Drager Babytherm 8010 (Open Incubator): When in use damp dust daily with Clinell universal sanitising wipes. Change weekly (when possible) and completely dismantle and clean the incubator with Clinell universal sanitising wipes. If the baby has had an infection, clean incubator as above but any concerns should be discussed with the Infection Control Link nurse or sister, or the Infection Control Department (ext 4595). Humidification chambers are non-disposable and are changed every 7 days with the incubators. Infusion devices > Syringe drivers (Alaris Asena CC ) > Alaris VP Plus pumps Ensure that all spilt blood, fluids, and drugs are cleaned off the pump immediately Pay particular attention to the grooves and recesses of the pump. Instruments from sterile packs Place into red and white striped bag with its ID tag and put in the sluice for return to CSSD for sterilisation. Intravenous drip stands Clean with Clinell universal sanitising wipes (remember to clean the base). Laryngoscope blades Single patient use and disposable. M3/M4 monitor (These are the small cardiac monitors e.g. transport incubator). Monitor, SaO 2 probe, ECG cable, pressure transducer, temperature probe and NBP cable can all be cleaned with Clinell universal sanitising wipes. Masks Ambubag / neopuff masks are single patient use. Can be cleaned using Clinell universal sanitising wipes if visibly soiled. Nebuliser masks are single patient use and should be wiped clean with Clinell universal sanitising wipes.

Multi-function monitors and appropriate wires at each bed space (Solar monitors by GE Healthcare in N1 and N2; Dash monitors by GE Healthcare in N3) TCM transducer the membrane and retaining rings are changed between patients. Nebulisers Controller unit & wire (neither is disposable): Clean with Clinell universal sanitising wipes. Do not immerse. Nebulizer adapter: change after 28 days if used in intermittent mode, or 7 days if used in continuous mode. T-piece: change after 7 days. Nitric Oxide (INOvent) To be cleaned following technician s instructions. cleaned using Clinell universal sanitising wipes. Outer casing can be Oxygen tubing Used from equipment to patient needs to be discarded after patient discharge / transfer. Used from equipment to equipment can be kept unless contaminated, damaged or dirty. If baby infected then all tubing discarded. Phototherapy light and monitoring box Clean with Clinell universal sanitising wipes (remember to clean the base). Phototherapy shield Razors Single use and are disposable. Retcam Lens: The lens should first be cleaned with Tristel pre-clean wipes to remove any organic matter Following this, the lens should be cleaned with Tristel Duo for Ophthalmology (effective in 30 seconds contact time) using a Tristel dry-wipe for application Finally the lens should be wiped with a Tristel rinse wipe to remove any Duo residue The rest of the monitor and leads can be cleaned with Clinell universal sanitising wipes. Saturation monitors Clean monitor with Clinell universal sanitising wipes.

2 types of probe: Disposable single patient use. Reusable - clean with Clinell universal sanitising wipes. Scales (small and large) Clean with Clinell universal sanitising wipes immediately after each use. Skin temperature probes Disposable single patient use. Non-disposable - clean with Clinell universal sanitising wipes. Spotlight Clean with Clinell universal sanitising wipes (remember to clean the base). Stethoscopes Clean daily and between patients using Clinell universal sanitising wipes. Remove ear pieces only. Leave chest piece intact unless visibly dirty. Suction reservoir and liners Reservoir - not disposable clean between patients with Clinell universal sanitising wipes. Liners are disposable and should be discarded when full or dirty, or between each patient. Current liners can go into clinical waste even when full as there is an absorbent substance in them that solidifies any secretions. Suction tubing Patient to reservoir - change daily and between patients. Wall to reservoir change between patients. Suction catheter Single use. TCM monitoring The module, leads and probes can be cleaned with Clinell universal sanitising wipes. Teats See Baby bottles and teats. Tecotherm Neo (cooling mattress) The machine and mattress should be cleaned with Clinell universal sanitising wipes. Thermometers (electronic) Probe covers are single patient use. Clean case with Clinell universal sanitising wipes.

Trolleys Silver trolleys should be cleaned immediately before and after use with Clinell universal sanitising wipes. Equipment trolleys (such as resuscitation and cannulation) should be damp dusted daily and thoroughly cleaned weekly with Clinell universal sanitising wipes. Bedside trolleys in the nurseries (cot space) should be damp dusted daily and thoroughly cleaned weekly with Clinell universal sanitising wipes; remembering to clean the drawer runners and trays. Notes trolleys and COWs (computers on wheels) should be cleaned with Clinell universal sanitising wipes. Ventilators All model casings can be cleaned with Clinell universal sanitising wipes. See technician guide for dismantling and cleaning instructions for specific models. X-ray lead squares Any concerns or queries regarding this policy, please contact either:- Rachel Burton Judith Simpson John Caisley TMBU Infection Control Link Nurse TMBU Infection Control Link Sister TMBU Technician