THERMASREG TR 040 THERMASREG TR 060

Similar documents
THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

for relative humidity and temperature

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

for relative humidity and temperature

Process Alarm Module RTA 421

ECL Comfort V a.c. and 24 V a.c.

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Temperature Sensors

ClimaSys Resistance heaters Selection guide

Frost Protection Thermostat

PRELIMINARY EDITION

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

ECL Comfort 300 / V a.c. and 24 V a.c.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Room Temperature Controller

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Thermal Management Products & Accessories for Enclosures

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

KPSW CONSOLE TERMINAL UNIT

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Immersion Temperature Controller

The Right Temperature, Always THS Series Modular Thermostats

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Thermostat RT. Data sheet

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Use. Functions. Key function. Other functions

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers

Manual Power relay SR853

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

DESIGN GUIDELINES. THERMAL building SOLUTIONS

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Temperature Control and Monitoring. innovations in heat tracing

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Frost Units for air temperature monitoring

ECL Comfort V a.c. and 24 V a.c.

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

OPERATING INSTRUCTIONS MAXIMAT LW CX COMPACT LEAKAGE SENSOR

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Operating Manual TR600

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Temperature & Humidity Controllers

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

ECL Comfort V a.c. and 24 V a.c.

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PEPPERL+FUCHS GmbH

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Wind Alarm Instrument

RVL480. Heating Controller

for relative humidity and temperature with calibration certificates

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Self-learning Room Temperature Controller

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Operating Manual MS220KA and MSR220KA

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Inductive slot sensor

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

Differential pressure sensors

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

IT system floor-standing distribution

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Rittal roof-mounted fans Efficiency on top

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

RVL481. Heating Controller. including d.h.w. heating

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

ACS-30-EU-EMDR- 10-MOD

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

ST Wiring diagram. Product description. Four-stage controller. Order number

Duct Air Quality Sensors

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

Fan heater Panther Powerful fan heater for large premises

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Transcription:

THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary (spiral coil sensor), working without external voltage. They are used for monitoring and to control temperatures in heat generation plants, in heating, ventilation and air conditioning systems, for ventilation, cooling and climate control in halls, cold storage rooms, greenhouses, nurseries, stables, breeding rooms, as industrial room thermostat or surface - mounted thermostat in industrial applications as well as in wet room and outdoor areas. Contact:... dustproof switch block unit as potential-free, single-pole or two-pole changeover contact Enclosure temperatur:... - 35 C...+ 65 C Capillary:... stainless steel, 1.4303, V2A Tolerance:... T min ± 3 K; T max ± 3 K; at 20 C ± 1K :... The preset setpoint (scale value) is equivalent to the switch-off value of the heating. The switch-on value is lower by the amount of operating difference. Contact 2-3 breaks when temperature :... The preset setpoint (scale value) is equivalent to the switch-on value of the cooling. The switch-off value is lower by the amount of operating difference. Contact 1-2 closes when temperature TR 040 TR TR 040 U U TW Dimensional drawing TR 040 Connecting diagram TR 040 THERMASREG TR 040, TR - 040 0 C +40 C 2 K +65 C External setting, TR TR - 040 U 0 C +40 C 2 K +65 C Internal setting, TW TR - 060 0 C +60 C 2 K +75 C External setting, TR TR - 060 U 0 C +60 C 2 K +75 C Internal setting, TW 128

THERMASREG TR 22 Temperature controllers, one-step, Mechanical temperature controller wet room temperature controller THERMASREG TR 22 with switching output and copper capillary, working without external voltage. It is used for moni toring and to control temperatures in heat generation plants, in heating, ventilation and air conditioning systems, for ventilation, cooling and climate control in halls, cold storage rooms, greenhouses, nurseries, stables, breeding rooms, as industrial room thermostat or surface-mounted thermostat in industrial applications as well as in wet room and outdoor areas. Contact:... dustproof switch block unit as potential-free single-pole changeover contact Enclosure temperatur:... - 35 C...+ 65 C Design principle:... torsion meter with liquid filling Capillary:... copper Tolerance:... T min ± 3 K; T max ± 3 K :... The preset setpoint (scale value) is equivalent to the switch-off value of the heating. The switch-on value is lower by the amount of operating difference. Contact 2-3 breaks when temperature :... The preset setpoint (scale value) is equivalent to the switch-on value of the cooling. The switch-off value is lower by the amount of operating difference. Contact 1-2 closes when temperature TR 22 TR TR 22 U TW Dimensional drawing TR 22 Connecting diagram TR 22 THERMASREG TR 22 TR - 22-35 C +35 C 3 K ± 1K +60 C External setting, TR TR - 22 U - 35 C +35 C 3 K ± 1K +60 C Internal setting, TW 129

THERMASREG TR 04040 Temperature controllers, two-step, Mechanical temperature controller wet room temperature controller THERMASREG TR 04040 with two independently switching outputs, which are separately adjustable (e.g. for switching between day and night time) and stainless steel capillary (spiral coil sensor), working without external voltage. It is used for monitoring and to control temperatures in heat generation plants, in heating, ventilation and air conditioning systems, for ventilation, cooling and climate control in halls, cold storage rooms, greenhouses, nurseries, stables, breeding rooms, as industrial room thermostat or surface-mounted thermostat in industrial applications as well as in wet room and outdoor areas. Contact:... dustproof switch block unit as potential-free single-pole changeover contact (two changeover contacts, separately adjustable) Cable gland:... 2x M 20 x 1.5 ; including strain relief Enclosure temperatur:... - 10 C...+ 65 C Capillary:... stainless steel, 1.4303, V2A Tolerance:... T min ± 3 K; T max ± 3 K; at 20 C ± 1K :... Contacts 2-3 and 5-6 break when temperature :... Contacts 2-1 and 5-4 break when temperature drops to the preset value. TR 04040 TR 04040 U Dimensional drawing TR 04040 Connecting diagram TR 04040 5 4 6 Step 1 Step 2 THERMASREG TR 04040 1. 2. 1. 2. Temperature Temperature Thermal Operating Thermal Operating Max. Capillary Type WG2 Range Range Difference (fixed) ca. Difference (fixed) ca. Temperature Function TR-04040 0 C +40 C 0 C +40 C 2 K 2 K +65 C TR +TW TR-04040 U 0 C +40 C 0 C +40 C 2 K 2 K +65 C TW +TW Features: TR = 1. Range: External setting (TR) and 2. range: Internal setting (TW) TR - U = 1. and 2. range: Internal setting (TW+TW) 130

THERMASREG TR - F Temperature controllers, one-step, with remote sensor, Mechanical temperature controller THERMASREG TR-F with remote sensor and switching output, working as capillary thermostat capillary controller without external voltage. This capillary controller is used for monitoring and to control temperatures of non-aggressive liquid or gaseous media in heating, ventilation and air conditioning technology as well as in mechanical and apparatus engineering, for installation in immersion sleeves or air conditioning ducts. Contact:... dustproof switch block unit as potential-free single-pole changeover contact Enclosure temperatur:... - 10 C...+ 65 C Design principle:... torsion meter with liquid filling Sensor:... copper tube, length of capillary = 1 m with PVC protective hose, Ø 6.8 mm Tolerance:... T min ± 3 K; T max ± 3 K Inserted length:... 130 mm or 200 mm in immersion sleeves Ø 8 x 0.5 mm (e. g. TH-ms - 30 14, accessories see table) Electrical connection:... 0.14-2.5 mm 2 via terminal screws :... wire contacts 2-3 :... wire contacts 2-1 - U Dimensional drawing Connecting diagram THERMASREG TR - F TR -1 - F - 35 C +35 C 3 K ± 1K +60 C TR TR - 060 - F 0 C +60 C 3 K ± 1K +75 C TR TR - 090 - F 0 C +90 C 3 K ± 1K +120 C TR TR - 0120 - F 0 C +120 C 5 K ± 1K +135 C TR TR - 50140 - F +50 C +140 C 5 K ± 1K +150 C TR Optional: U = Internal setting TW Accessories: THR - ms - 08 130 Brass immersion sleeve,130 mm, Ø 8 x 0.5 mm THR - VA - 09 130 Stainless steel immersion sleeve,130 mm, Ø 9 x 1.0 mm 131

THERMASREG Temperature controller for top hat rail installation for remote sensor, with multi-range switching and switching output Electronic top hat rail thermostat top hat rail temperature controller THERMASREG for installation in distributor boxes or control cabinets, with switching output, multi-range switching, and adjustable hysteresis. It is used for electronic control and monitoring of temperatures by remote sensors in the residential sector (e.g. in connection with floor heating systems), in halls and greenhouses and in the industrial sector. This controller is provided with sensor breakage detection and a switch-off function. Power supply:... 24 V DC, +10 % 15 %; 24 V AC or 230 V AC, +10 % 15 %, 50-60 Hz Power consumption:... 2.5 VA Control range:... -10 C +30 C; +20 C +80 C; +60 C +120 C, selectable Input:... Pt1000 Output:... relay as single-pole, potential-free changeover contact (1x) Switching capacity:... max. 6 A 250 V AC (Contact load) Ue le AC-15, 120 V 3,5 A, 240 V 3 A Ue le DC-13, 24 V 2.5 A EN 60947-5-1, VDE 0435 Operating Difference:... adjustable Lifetime:... changeover contact mechanical: 5 x 10 6 changeover contact electrical: 1 x 10 5 Ambient conditions:... -20 C...+60 C, non-precipitating air Operating mode indicator:... LED Enclosure:... plastic, colour black-grey (similar RAL 7021) and light grey (similar RAL 7035), width: 45 mm, 3TE Electrical connection:... 0.14-2.5 mm 2 via terminal screws Mounting:... on DIN top hat rail Humidity:... < 90 % r. H., non-precipitating air Protection class:... II (according to EN 60730) Protection type:... IP 20 at front side (according to EN 60529) Standards:... CE conformity, electromagnetic compatibility according to EN 61 326 + A1 + A2, EMC directive 2004 108 EC, low-voltage directive 73 23 EEC The range of interpretation is selected at the lower potentiometer. Three measuring ranges can be chosen: -10 C +30 C; +20 C +80 C; +60 C +120 C. The temperature to be monitored is determined by the potentiometer»setpoint«and the switchpoints (hysteresis) are defined at the potentiometer»hyst.«when temperature at the Pt1000 exceeds the value of»setpoint + Hyst.«, the output relay switches to rest position (switched off). When temperature falls below»setpoint - Hyst.«, the output relay is reactivated. The following conditions result in a drop of the relay to rest position: Excess temperature, short circuit, or wire breakage at the Pt 1000 sensor, failure of power supply. Measuring input and power supply have no electric connection i.e. are galvanically isolated. Connecting diagram A1 A2 11 14 12 T1 Supply voltage max. 8A Rx T2 Dimensional drawing Scheme THERMASREG Type WG2 Supply Voltage Input Output Sensor 230V AC 230 V AC, 2.5 VA Pt1000 1 x changeover contact (potential-free) 24V AC 24 V AC, 2.5 VA Pt1000 1 x changeover contact (potential-free) 24V DC 24 V DC, 2.5 VA Pt1000 1 x changeover contact (potential-free) 155