Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Similar documents
Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

Genie Heated Regulator Installation & Operation Instructions

Physikalisch-Technische Bundesanstalt

Performance Data. curus Component Recognized; File No. E IP 20

Manual OW Caution:

Manual Isolating Barrier D461R1 (Revision 01)

The CE Marking Access to the European Market

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Manual Isolating Barrier D461 (Revision 05)

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

MANUAL. for heat press. Secabo TC2

MANUAL. for heat presses. Secabo TC5 and TC7

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

Operating Manual MS220Vi and MSR220Vi

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

Manual Power relay SR853

Operating Manual MS220VA and MSR220VA

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Technical Data. General specifications. Rated operating distance s n 5 mm

Documentation. Parallel Heating Cable. Type: ELP

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

IECEx Certificate of Conformity

DL/DLM. Operating instructions Manuel d instructions Instrucciones de uso

Inductive slot sensor

INSTRUCTION & SERVICE MANUAL

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Indoor/outdoor resistance thermometer Model TR60

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Flameproof Manual Call Points Series MCP

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PEPPERL+FUCHS GmbH

PIT UMF2 (B) Magnetic-Inductive Flow Velocity Sensor. Operating Manual. Page 1 of 14

Technical Data. Dimensions

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Manual Distribution box

Technical Data. Dimensions

805QS Pressure Switch-Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Manual MS220DA

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Gas cylinder scale Model GCS-1

Rev Installation Guide. Sondex Industrial and Marine Pumps

Electrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex)

OPTIBAR P 1010/2010 C Supplementary instructions

Operating Manual Ionizer

Operating Instructions

Certification Supplement Manual

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Electrical Installations Design, Selection, Erection and Inspection

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Level Electrode NRG Original Installation Instructions English

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

REC LRD0 / LGD0 DE EN FR IT ES NL RU PL LT LV SR CZ RO BG HU

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Technical Data. Dimensions

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

standards: standards:

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Temperature Measurement Transmitters for field mounting

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

Safety instructions VEGAPULS 64

PROTECT SRB 200EXi-1A

Earth-Rite II PLUS Static Earthing System

Technical Data. Dimensions

Certificate of Compliance

IECEx Certificate of Conformity

IECEx Certificate of Conformity

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Flameproof Manual Call Points

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Frost Protection Thermostat

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Certification Supplement Manual

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Transcription:

Hazardous Location Heaters Thermostat INSTRUCTION MANUAL Rev. K 2018 nvent P/N 89115890

TABLE OF CONTENTS Warranty and Return Policy...2 Application...3 Control Accuracy...3 Technical Data...3 Design Data...3 HLTSTAT Thermostat Nominal Setpoints...3 Explosion Protection...4 Installation Instructions...4 ROUTINE CHECK TESTS...5 Initial Operation...5 Wiring Diagram...7 Maintenance...7 CE Declaration of Conformity...8 NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact nvent if further information is required. WARRANTY AND RETURN POLICY https://hoffman.nvent.com/en/hoffman/warranty-information - 2-2018 nvent

APPLICATION When connected to an electric heater, the thermostat can regulate the temperature in a housing to the pre-set, nominal, setpoint; see HLTSTAT Thermostat Nominal Setpoints table below. The thermostat closes the circuit when the temperature is below the setpoint and opens it when the temperature is above the setpoint. CONTROL ACCURACY The air temperature in a heated housing is not the same everywhere. Depending on the difference between inside and outside temperature (delta T), insulation, configuration of the heater and the installed equipment etc., the temperature (e.g. between top and bottom) can fluctuate by 18 F [10 C] or more. For exact temperature control of an instrument, a proportional controller with temperature sensor should be used. TECHNICAL DATA DESIGN DATA Rated voltage (VAC or VDC) Maximum Rated Current (Amps) (acc. to DIN VDE 0298) HLTSTAT10C, HLTSTAT20C 0-275V Temperature Tolerance +/- 5 F [3 C] Temperature class Ambient temperature Maximum permissible operating temperature range at normal rating Connection cable Conduit connection Ingress Protection Material 10 T6-76 to +140 F (-60 to +60 C) -76 to +302 F (-60 to +150 C) 39 (1m) long silicone cable, notch and oil resistant, 3x AWG16; Ø 0.37 (9.4mm) ½ NPT IP66 / IP68 (1bar/30min) seawater-proof aluminium, black anodized Length (in./mm) 3.5 (89) Width (in./mm) 1.6 (41) Depth (in./mm) 1.2 (30) Weight (lb./g) 1.1 (28) HLTSTAT THERMOSTAT NOMINAL SETPOINTS Type Switch on Switch off HLTSTAT10C 50 F / 10 C 64 F / 18 C HLTSTAT20C 68 F / 20 C 82 F / 28 C 2018 nvent - 3 -

Manufacturer CSA Certificate CSA Type of Protection EXPLOSION PROTECTION TAE INTERTEC-Hess 1655545 (LR43674) Cl. I, Grp. ABCD T6 Cl. II Grp. EFG IEC Scheme Certificate IECEx PTB 07.0054X EC Type Examination Certificate Marking PTB 03 ATEX 1136 X II 2 G Ex db IIC T6 II 2 D Ex tb IIIC T80 C INSTALLATION INSTRUCTIONS The thermostat must be attached to the face of the heater as noted. nvent DAHHL finned heaters are equipped with slotted mounting rails in the fins. Slightly loosen the mounting bolt included in the thermostat. Insert the head of the bolt into one of the slotted mounting rails of the finned profile. The PTFE spacer must remain outside, as this provides the right gap from the thermostat to the surface of the heater fins. Carefully tighten the bolt by turning the thermostat. DO NOT OVERTIGHTEN. The thermostat is equipped with a ground terminal. Use a cable gland or a ½ NPT conduit depending on the application. Be careful not to bend or exert any load on the connection cable during unpacking and transport. Before entering the customer-supplied Ex junction box, the connection cable must be firmly installed and mechanically protected observing the permissible bending radius of 5 times the outside cable diameter. If the connection is made in a hazardous area, the connection cable must be connected in a housing that meets the requirements of one of the types of ignition protection mentioned in EN 50014 Section 1.2. When determining the operating temperature, the maximum permissible ambient temperature, self-heating and, possibly, heat transfer (medium) must be considered. In dust hazardous areas, the applicable requirements of the EN 60079-14 have to be observed. CAUTION! Remove the RED protection cap only for ½ NPT conduit installation. Never remove the adapter. See Figure 3 on page 6 The components must only be connected and secured by certified technical personnel in accordance with the label specifications rated voltage and rated current. Circuit breakers suitable for up to 16 A can be used for short circuit and line protection. A ground terminal is provided for the purpose of ensuring potential equalization; see Figure 1 on page 5. The terminal is marked as such. - 4-2018 nvent

ROUTINE CHECK TESTS The following check tests have to be carried out on the installed heating system: Do a Visual inspection to determine if the conditions specified under Installation Instructions are met. Conduct an insulation test. INITIAL OPERATION When the routine tests are successfully completed, the device can be switched on. Spacer Mounting Surface Figure 1 2018 nvent - 5 -

Figure 2 Figure 3-6 - 2018 nvent

WIRING DIAGRAM L N PE Junction Box (Customer Supplied) bn bu bn bu ye/gn ϑ> PA. Thermostat PA. Heater bu =blue bn=brown ye/gn=yellow/green Figure 4 MAINTENANCE The thermostat is completely encapsulated in silicone, and requires no maintenance. Performance and safety tests can be conducted at intervals as determined by the operator in compliance with current regulations. Repairs must only be done by the manufacturer. In dust hazardous areas, applicable requirements of EN 60079-17 and EN 60079-19 must be observed. 2018 nvent - 7 -

CE DECLARATION OF CONFORMITY EU-Konformitätserklärung C EU Declaration of Conformity ЕС декларация соответствия INTERTEC Hess GmbH Raffineriestraße 8 93 333 Neustadt / Donau Wir We Мы erklären in alleiniger Verantwortung, dass das Produkt auf das sich diese Erklärung bezieht den Bestimmungen der folgenden Richtlinien entspricht 2014/34/EU (ATEX) 2014/35/EU (LVD) 2014/30/EU (EMC) 2011/65/EU (RoHS) 2012/19/EU (WEEE) und mit folgenden Normen oder normativen Dokumenten übereinstimmt INTERTEC Hess GmbH, declare under our sole responsibility that the product TA to which this declaration relates is in accordance with the provision of the following directives 2014/34/EU (ATEX) 2014/35/EU (LVD) 2014/30/EU (EMC) 2011/65/EU (RoHS) 2012/19/EU (WEEE) and is in conformity with the following standards or other normative documents заявляем под свою исключительную ответственность, что продукция на которую распространяется данное заявление, соответствует следующим директивам 2014/34/EU (ATEX) 2014/35/EU (LVD) 2014/30/EU (EMC) 2011/65/EU (RoHS) 2012/19/EU (WEEE) и соответствует следующим стандартам или другим нормативным документам EN IEC 60079-0:2012+A11:2013 EN IEC 60079-1:2014 EN IEC 60079-31:2014 EN IEC 60529:1991+A1:2000+A2:2013 EN IEC 61000-6-4:2007+A1:2011 Kennzeichnung Marking Маркировка C 0102 ` II 2 G Ex db IIC T6 ` II 2 D Ex tb IIIC T80 C Degree of protection IP66/ IP68 1bar/ 30min PTB 03 ATEX 1136 X Neustadt, den 25.05.2018 Dipl.-Ing. Martin Hess Geschäftsführer BINT040 INTERTEC-Hess GmbH Raffineriestr. 8 93333 Neustadt/Donau Germany +49 9445 9532-0 info@intertec.info - 8-2018 nvent

NOTES 2018 nvent - 9 -

NOTES - 10-2018 nvent

NOTES 2018 nvent - 11 -

Rev. K 2018 nvent P/N 89115890