Mail to: Service at Account: 25980 Little Rock-fox Fire Dept Plano Molding Company 5 EAST NORTH STREET 431 E. South Street PLANO, Illinois 60545 Plano, IL 60545 Test Type Summary Total Pass Fail Not Tested Audio - s 1 1 0 0 Control Valve 13 12 1 0 Fire Pump - Loss of Power 1 1 0 0 Fire Pump - Running 1 1 0 0 Pull Station 14 14 0 0 Smoke/Heat Combo 11 8 0 3 Supv H/L Air 1 1 0 0 Temperature Sensor 12 12 0 0 W-F Pressure 1 1 0 0 WF-Vane 8 7 0 1 Total 63 58 1 4 Inspection Tasks Monitoring station? ADS 630-844-6302 Time Out? 08:39 By Who? 1446 Owner (or rep) name and number? Was the onsite person notified of test results? Time In? 12:20 By Whom? 1203 Inspector's Notes Inspector's suggested improvements, but are not the result of an engineering survey: Panel Section Hallway by lunch room Make & Model 7200 FCI Battery Size & Date 2-12v18ah 12/17 Local trouble sounder, lights, displays, buttons, and switches functional? Panel-NAC 1 of 6
Panel-NAC Radio Device Area Location Zone ID Result Smoke/Heat Combo File room Z3 01002780 Smoke/Heat Combo By conference room B Z1 01002781 Smoke/Heat Combo Lower level Z2 01002782 Pull Station At panel Z70 01002748 Pull Station At panel Z11 01002749 Pull Station Area 7 Z8 01002754 Pull Station Plano store Z7 01002757 Pull Station Engineering office exit door Z6 01002762 Pull Station At shipping dock area door 4 Z9 01002763 Pull Station At main entrance Z3 01002767 Pull Station At employee entrance Z4 01002768 Pull Station Area 1 Z2 01002770 Pull Station Area 1 west exit Z8 01002772 Pull Station Area 2 Z1 01002776 Pull Station Area 1 south exit Z7 01002778 Pull Station At engineering exit Z5 01002789 Audio - s 27 AVS/11 strobes Temperature Sensor Pump room Z55 01002735 Temperature Sensor Area 7 east wall Z52 01002739 Temperature Sensor Finishing room Z51 01002756 Temperature Sensor Plano store storage Z50 01002758 Temperature Sensor Area 6 warehouse Z59 01002759 Temperature Sensor Tool room Z47 01002761 Temperature Sensor Area 4 materials office Z44 01002764 Temperature Sensor Front office Z41 01002766 Temperature Sensor Area 2 East Z39 01002769 Temperature Sensor Area 2 by Riser Z38 01002773 Temperature Sensor Area 1 Z37 01002777 Control Valve Pump room Z56 01002732 Control Valve Pump room Z56 01002733 Control Valve East riser area 7 Z53 01002736 Control Valve Riser 5 area 4 in closet Z45 01002740 Control Valve Area 2 riser 3/outside Z40 01002743 Control Valve Area 3 outside/main parking lo Z43 01002744 FAIL Device Failure Comment: seized Control Valve Riser 6/ outisde PIV Z48 01002745 Control Valve Riser 8/ outside PIV Z49 01002746 Control Valve Area 4 riser 5 outside PIV Z45 01002747 Control Valve Building 5 riser Z49 01002760 2 of 6
Device Area Location Zone ID Result Control Valve Area 2 riser 2/outside Z36 01002774 Control Valve Area 2 riser 1 lube/outside Z36 01002775 Fire Pump - Running Fire Pump - Loss of Power Pump room Z57 Supv H/L Air Riser 2 Area 7 Z54 01002737 W-F Pressure Area 7 Z63 01002738 WF-Vane Building area 4 Z66 01002742 WF-Vane Area 2 riser 2 Z68 01002750 WF-Vane Building 4 area 3 Z67 01002751 WF-Vane Building 5 Z65 01002752 WF-Vane Building 6 Z64 01002753 WF-Vane Building 7 Z61 01002755 WF-Vane Area 2 riser 3 Z69 01002771 WF-Vane Area 2 riser 1 Z60 01002779 Device Failure Comment: blocked, no access WF Trip Delay Building 6 Z64 **002753 Time to alarm? 25 seconds WF Trip Delay Building area 4 Z66 *1002742 Time to alarm? 15 seconds WF Trip Delay Area 2 riser 2 Z68 *1002750 Time to alarm? 65 seconds WF Trip Delay Building 4 area 3 Z67 *1002751 Time to alarm? 75 seconds WF Trip Delay Building 5 Z65 *1002752 Time to alarm? 10 seconds WF Trip Delay Building 7 Z61 *1002755 Time to alarm? 50 seconds WF Trip Delay Area 2 riser 3 Z69 *1002771 Time to alarm? 45 seconds WF Trip Delay Area 2 riser 1 Z60 *1002779 Time to alarm? Smoke/Heat Combo 2nd Floor Upper level Z11 01002783 Smoke/Heat Combo 2nd Floor At sales Z12 01002785 Smoke/Heat Combo 2nd Floor At sales Z13 01002786 Smoke/Heat Combo 2nd Floor Marketing Z10 01002787 Smoke/Heat Combo 2nd Floor Marketing room Z14 01002788 Pull Station 2nd Floor At sales 2nd floor Z10 01002784 Smoke/Heat Combo Annual Building 4 Z4 01190471 Smoke/Heat Combo Annual Building 8 Z6 01190472 3 of 6
Device Area Location Zone ID Result Smoke/Heat Combo Annual Building 6 Z5 01190473 Control Valve City pressure Pump room Z58 01002734 Temperature Sensor Office area Area 3 engineer closet Z42 01002765 Transmitter Section Radio Outside lunch room west wall Transmitter Type? Radio Battery Size & Date 12v8ah 8/16 Fire Signal Received? Trouble Signal Received Supervisory Signal Received 4 of 6
Inspection Discrepancies Mail to: Service at Account: 25980 Little Rock-fox Fire Dept Plano Molding Company 5 EAST NORTH STREET 431 E. South Street PLANO, Illinois 60545 Plano, IL 60545 Panel-NAC Panel-NAC Radio Control Valve Area 3 outside/main parking lo Z43 01002744 FAIL FAIL Mechanically frozen Comment/Reason: seized WF-Vane Area 2 riser 1 Z60 01002779 Comment/Reason: blocked, no access Smoke/Heat Combo Annual Building 4 Z4 01190471 Smoke/Heat Combo Annual Building 8 Z6 01190472 Smoke/Heat Combo Annual Building 6 Z5 01190473 Summary for Ticket: Device Test Type Summary Count Pass Fail Not Tested 5 of 6
Audio - s 1 1 0 0 Control Valve 13 12 1 0 Fire Pump - Loss of Power 1 1 0 0 Fire Pump - Running 1 1 0 0 Pull Station 14 14 0 0 Smoke/Heat Combo 11 8 0 3 Supv H/L Air 1 1 0 0 Temperature Sensor 12 12 0 0 W-F Pressure 1 1 0 0 WF-Vane 8 7 0 1 Total 63 58 1 4 6 of 6