E-PLEX 5x70 Series Stand-Alone Access Controller. Installation Instructions

Similar documents
Model NT20e Installation Guide

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

WARNING Important Safety Information

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

FLCH4R Garage and Utility Electric Heater

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

WARNING Important Safety Information

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

WARNING Important Safety Information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

WARNING Important Safety Information

Document No

VX SERIES Wireless Thermostat with Occupancy Sensor

IMPORTANT INFORMATION

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Item no PERSONAL V2.0. User s Manual

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Proliphix Thermostat Installation Guide. Release 2.0

DIGITAL STEEL FIRE & SECURITY

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

LIGHTNING VAULT WALL MOUNT SINGLE HANDGUN

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

2 - Wire Programmable Digital Thermostat

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

240 ASSEMBLY & OPERATION MANUAL

Model 3901T / 3902T / 3903T

OWNERS MANUAL MODEL 451 (-101 & -201)

DE5300 Delayed Egress System. General Information

Environmental Monitoring SmartSlot Card

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Addendum for STI-6406 with Dual Access Control

WARNING Important Safety Information

M770 ph Controller Owner s Manual

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

MGC Dock User s Manual

Installation Guide for models:

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

FUME HOOD MONITOR ALNOR AIRGARD 200

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

OPTICAL TURNSTILE SYSTEM

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

EcoBrite Smooth Light LED Light Fixtures

Series. Access Power Controllers. Installation Guide

KT-100 Door Controller

ALM100 Alarm Module. User s Manual

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

2010 Sedona Series Components

owner s manual MX650-CCX

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

DIGITAL STEEL FIRE & SECURITY

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

User's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access

SC Installation, Operation & Application Guide

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

THUNDER LOW FREQUENCY AMPLIFIER INSTALLATION MANUAL

Installation & Operation Manual

MODEL B2 INSTALLATION MANUAL

HI Industrial Utility Heater HI Soleus Air International

CORNELL Emergency Response Systems

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Model: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.

INSTALLATION AND OPERATION INSTRUCTIONS

Owner s Manual. PIR-1 IR Learner

Owner s Manual. 5 year parts limited warranty. See inside for details

HD-26, HD-36, HD-48 Heated Displays

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

shine TM Manual User guide and installation instructions The global leader in door opening solutions

Power Locking Installation Manual

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

DIGITAL. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS2054DF84DF18DFE0809 ENGLISH

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

Installation Instructions EFS Hand Washing Station

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

Installation & Operation Manual

Model 405 AIRGARD Fume Hood Monitor

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

Environmental Monitoring Card

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

Installation Guide for models:

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

636 and 646 Keypads. User s Manual

WVD100. EZ Loop. Product Manual. Wireless Vehicle Detector. Installation Instructions Program Instructions. AP100 Relay Board S200 Sensor

MGC Dock User s Manual

INSTRUCTION MANUAL P Heating and 1 Cooling

Remote Chexit Module (RCM) System. General Information

Transcription:

E-PLEX 5x70 Series Stand-Alone Access Controller Installation Instructions 1

Table of Contents STEP...PAGE Tools Required... 2 A-1 Wall Installation...4 A-2 Gang Box Installation... 5 B-1 System Components...6 C-1 Component Wiring Connections...6 D-1 Tamper and Security Features...16 E-1 Software Setting...18 F-1 Hard Rest Procedure...18 Warranty Card... 7 Template... 10 11 WARNING: The Master Code of this unit has been factory preset: 1, 2, 3, 4, 5, 6, 7, 8. To activate lock functions, the master combination must be changed at time of installation. Warning and Cautions IMPORTANT: Carefully inspect windows, doorframes, door, lights, etc. to ensure that the recommended procedures will not cause any damage. Kaba Access Control's warranty does not cover damages caused by installation. CAUTION: Wear safety glasses during installation. TOOLS REQUIRED Electric Drill/Screwdriver with Variable Speed and Torque Various Flat and Phillips Bits for Power Driver Wire Cutter/Stripper Small Straight (Flat Head) Manual Screwdriver Wall Anchors with #10 and or #6 Flat Head Screws or Masonry Screws Masonry or Wood Drill Bits for Various Surfaces For technical assistance please call 1.800.849.TECH (8324) or 336.725.1331

ACU PIU 3

A-1 Wall Installation A-1.1 Please place the template (located in the middle of this. manual) on mounting surface to ensure that there are no obstructions; this allows the keypad housing to be moved up, then in and down onto the base plate. Mark and drill four holes for wood screws, wall anchors, or masonry screws and a. 1 2" diameter cable hole. Remove the template. A-1.2 A-1.3 A-1.4 Thread the cable from the back of the Outside Housing,... through the large hole in the Shim and into the hole in the wall. Remove the two security screws from the bottom of the Backplate & Gasket using the small wrench provided in the bag. Slide the back down about one inch while pulling it away from the housing. Position Shim, Gasket & Backplate and fasten with #10 Flat Head screws in the four large holes or with two #6 Flat Head screws in the two smaller holes or any combination of each.. A minimum of two #6 screws is recommended. Push all excess cable into the wall. Hold the top of the Outside Housing about one inch above the top of the Baseplate that is now screwed to the wall and push until the Gasket is flush with the back edges of the Outside Housing. Now push in and down until the bottom of the Baseplate and the bottom of the. Outside Housing are flush. Use the wrench provided to replace the security screws. TEMPLATE SHIM BACKPLATE & GASKET OUTSIDE HOUSING WITH KEYPAD SECURITY SCREWS 4

A-2 Gang Box Installation A-2.1 Mount Gang Box on the wall referring to the Template to insure clearance above the box. This allows the Keypad. Housing to be moved up, then in and down onto the Baseplate. Mark and drill holes for wood screws, wall anchors, or masonry screws and a 1 2 " diameter cable hole. A-2.2 Thread the cable from the back of the Outside Housing... through the large hole in the Shim, into the hole in the Gang Box and into the wall. Remove the two security screws from the bottom of the Backplate & Gasket using the small wrench provided in the bag. Slide the back down about one inch while pushing it away from the housing. A-2.3 Position the Backplate & Gasket, sandwiching the Shim against the Gang Box and fasten the Backplate & Gasket with #6 Flat Head screws into the two smaller holes that line up with the holes in the Gang Box. A-2.4 Push all excess cable into the wall conduit. Hold the top of the Outside Housing about one inch above the top of the Baseplate that is now screwed to the Gang Box and push until the Gasket is flush with the back edges of the Outside Housing. Now push in and down until the bottom of the Baseplate and the bottom of the Outside Housing are flush. Use the wrench provided to replace the security screws. GANG BOX SHIM BACKPLATE & GASKET OUTSIDE HOUSING WITH KEYPAD SECURITY SCREWS 5

B SYSTEM COMPONENTS B-1 Kaba s E-Plex Stand-Alone Access Controller consists of the Access Control Unit (ACU) and the Power Interface Unit (PIU). It is typically used in conjunction with an off-the shelf door controller or power extender (not included) connected to. either a magnetic lock or electric strike for securing doors or. a parking gate for access control of parking areas. The door controller which must have battery back-up (manufactured by Securitron, Altronix, and others) is typically mounted on the inside wall next to the door or up in a drop ceiling for control of the door through interface with the magnetic lock or. electric strike. Door Controller (other) Kaba PIU Kaba ACU C COMPONENT WIRING CONNECTIONS C-1 Installation of this system is really quite simple. The door. controller is interfaced to the device that permits access to the door which typically provides support for either a. magnetic lock or electric strike, along with inputs for remote 6 exit (RE) and Fire alarm access.

KABA E-PLEX LIMITED WARRANTY Kaba Access Control warrants this product to be free from defects in material and workmanship under normal use and service for a period of three (3) years. Kaba Access Control will repair or replace, at our discretion, locks found by Kaba Access Control analysis to be defective during this period. Our only liability, whether in tort or in contract, under this warranty is to repair or replace products that are returned to Kaba Access Control within the three (3) year warranty period. This warranty is in lieu of and not in addition to any other warranty or condition, express or implied, including without limitation merchantability, fitness for purpose or absence of latent defects. ATTENTION: This warranty does not cover problems arising out of. improper installation, neglect or misuse. All warranties implied or written will be null and void if the lock is not installed properly and/or if any. supplied component part is substituted with a foreign part. If the lock is used with a wall bumper, the warranty is null and void. If a doorstop is required, we recommend the use of a floor secured stop. The environment and conditions of use determine the life of finishes on Kaba Access Control products. Finishes on Kaba Access Control products are subject to change due to wear and environmental corrosion. Kaba. Access Control cannot be held responsible for the deterioration. of finishes. Authorization to Return Goods Returned merchandise will not be accepted without prior approval.. Approvals and Returned Goods Authorization Numbers (RGA Numbers) are available through our Customer Service department in Winston-Salem, NC (800) 849.8324. The serial number of a lock is required to obtain this RGA Number. The issuance of an RGA does not imply that a credit or replacement will be issued. The RGA number must be included on the address label when material is returned to the factory. All component parts including latches and strikes (even if not inoperative) must be included in the package with return. All merchandise must be returned prepaid and properly packaged to the. address indicated. 7

For your records. Model No.: Date Purchased: Dealer: Name: Telephone: Notes For technical assistance please call 1.800.849.TECH (8324) or 336.725.1331 8

7.000 'B' 'W' 'W' 4.000 1.250 1.531 3.250 'B' 'W' 'W' 10 1.500 3.000.750

2 HOLES B, ARE SPACED FOR DUPLEX OUTLETS, WHEN MOUNTING TO A SINGLE GANG OUTLET BOX. ALIGN THE HOLE IN THE BACK OF THE BOX TO THE HOLE IN THE WALL MADE FOR THE CABLE, SCREW THE BACK OF THE BOX TO THE WALL, DRILL A 3/8" HOLE INTO A BLANK OUTLET COVER THEN THREAD THE CABLE THROUGH THE SUPPLIED SHIM PLATE, AND ON THROUGH THE BACK OF THE BOX INTO THE WALL HOLE, USE 2 #6 FLAT HEAD SCREWS TO GO THROUGH THE ACU S BASE HOLES THEN THROUGH THE BLANK COVER INTO THE SINGLE GANG BOX HOLES. (SCREWS NOT PROVIDED) AFTER THE SAC BASE IS SCREWED INTO PLACE, PRESS THE RUBBER BUMPER INTO THE SAC BASE HOLE TO ADHERE TO THE SUPPLIED SHIM PLATE BEFORE YOU SLIDE THE KEY- PAD HOUSING ONTO IT S BASE. 1.750 KABA ACCESS CONTROL TEMPLATE FOR KABA ACCESS MOUNTING CONTROL THE TEMPLATE ACCESS CONTROLLER FOR MOUNTING (ACU) THE ACCESS UNIT CONTROLLER (ACU) UNIT 3.281 1/2" HOLE FOR CABLE WHEN NOT MOUNTING TO AN OUTLET BOX, USE THESE 4 HOLE POSITIONS, W, TO LOCATE DRILL POINTS FOR WALL ANCHORS THAT USE #10 FLAT HEAD SCREWS. FOR MASONRY, 2 DIAGONAL HOLES MAY BE SUFFICIENT. (DO NOT OVERTIGHTEN AND WARP BASE) (WALL ANCHORS ARE NOT PROVIDED.) ALTER- NATIVELY, 4 PILOT HOLES FOR #10 WOOD SCREW FOR CLAPBOARD CONSTRUCTION MAY BE POSITIONED AT THESE LOCATIONS. THIS RECTANGULAR OUTLINE IS THE APPROXIMATE AREA THAT MUST BE CLEARED AROUND THE ACU. NOT TO SCALE 11

BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 1563 WINSTON-SALEM, NC POSTAGE WILL BE PAID BY ADDRESSEE KABA ACCESS CONTROL 2941 INDIANA AVENUE WINSTON-SALEM, NC 27199-3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES

REGISTRATION CARD Thank you for purchasing our product. In order to protect your investment and to enable us to better serve you in the future, please fill out this registration card and return it to Kaba Access Control, or register online at www.kabaaccess.com. Name Position Company Address City State ZIP (Postal Code) Country Phone Email Name of Dealer Purchased From Date of Purchase Lock Model Number This lock will be used in what type of facility? Commercial Building Industrial / Manufacturing Airport College / University Government / Military School / Educational Hospital / Healthcare. Other (please specify) What area is being secured with this lock? (e.g. Front Door,. Common Door, Exercise Room) This lock is: New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other than Kaba How did you learn about Kaba Access Control Pushbutton Locks? Advertisement Previous Use Internet / Web Another Use Locksmith Maintenance Training Class Other (please specify) What was your reason for buying this lock? Who installed your lock? Locksmith Maintenance Other Check here if you would like more information on Kaba Access Control locks.

C-2 The PIU requires a four (4) wire interface from the door. controller. Two wires provide +12 or +24 VDC to the power. interface unit and two wires support normally open (N.O.) switch closure from the power interface unit. DOOR CONTROLLER AND ALARM BOX ALTRONIX, SECURITRON, ETC. MAG OR STRIKE 12 24 VDC + SECURITY ALARM BACK-UP BATTERY (ON INSIDE WALL) RED BLACK POWER FROM ALARM BOX SAC INTERFACE (IN P.I.U.) CONTROLLER INTERFACE J5 CONTACT CLOSURE BLACK RED + SW6 ALARM SW5 LOCK INTERFACE J6 RED BLACK ORANGE WHITE BLUE GREEN PURPLE J7 YELLOW CONTACT CLOSURE SHUNT RESET C-3 The interface between the PIU and the ACU requires an eight wire connection using the screw terminals on the interface board assembly inside the PIU enclosure. On the opposite. end, the eight wires are expanded inside the ACU which also. includes 10 feet of cable for ease of installation in most door installations. 15

C-4 Each of the wire colors is plainly labeled on the PIU s. interface board assembly next to the connector J6. (See Figure 1) The standard cable length is 10 feet. Typical installation will have Kaba s ACU mounted on the unsecured side of the wall next to the door controlled. The door. controller and Kaba s PIU are mounted on the secure side of the door. The ACU is designed to be mounted directly onto. different types of wall surfaces or on a single gang. electrical box. D TAMPER AND SECURITY FEATURES D-1 Kaba s Stand-Alone Access Controller has features built in that can provide an extra layer of security to the installa-..tion. The Shim Plate installed between the ACU and mounting surface has a bump that extends through a hole in the Backplate. This bump depresses a security switch in the controller to indicate that the installation is secure. If the ACU is opened, vandalized, or removed from the surface it is mounted to, the switch will trigger a disarming of the lock. If tampering is. detected by the ACU, the lights at the top of the unit will glow blue until the unit is reset. The ACU must be returned to the secure position and the reset button pressed on the PIU (See Figure 1) to restore the door access and operation. Since the reset occurs at the PIU which is on the secure side of the door, another point of access must be available. This feature may be disabled by turning the bottom switch on SW6 off. (Refer to Figure 3 on Page 19) D-2 Another feature of this lock is the SHUNT circuit. SW5 allows selection of one of four switches to control the duration of the Shunt. A SHUNT is typically used to indicate a valid access to a central alarm system. Different alarm systems require different period closures for this purpose and therefore the selections are.1,.2,.5, and 1 second duration. Only ONE switch may be selected. This SHUNT period is also part of the overall period selected for opening. If the SHUNT is one second and the period for opening is three seconds, the opening will only last 2 seconds. The door remains secure until the end of the SHUNT period. The SHUNT closure is factory set to normally open (N.O.) but may be changed by changing the jumper on J7 from 1->2 to 2->3. This will make the SHUNT. normally closed (N.C.). (See Figure 2) 16

Figure 1 (ON INSIDE WALL) DOOR CONTROLLER AND ALARM BOX ALTRONIX, SECURITRON, ETC. (ON INSIDE WALL) RED BLACK MAG OR STRIKE 12 24 VDC + SECURITY ALARM BACK-UP BATTERY FIRE ALARM LOCKING DEVICE KABA Access Controll Unit (ACU) (ON OUTSIDE WALL) KABA POWER INTERFACE UNIT (P.I.U.) SAC INTERFACE (IN P.I.U.) 8 CONDUCTOR CABLE FROM SAC OUTSIDE (TO P.I.U.) POWER FROM ALARM BOX SAC INTERFACE (IN P.I.U.) CONTROLLER INTERFACE J5 CONTACT CLOSURE BLACK RED + SW6 ALARM SW5 SHUNT LOCK INTERFACE J6 RED BLACK ORANGE WHITE BLUE GREEN PURPLE YELLOW CONTACT CLOSURE FOIL CENTRAL ALARM (OPTIONAL) RESET DOOR Close-up SAC INTERFACE (IN P.I.U.) CONTROLLER INTERFACE J5 CONTACT CLOSURE BLACK RED + ALARM J7 LOCK INTERFACE J6 RED BLACK ORANGE WHITE BLUE GREEN PURPLE YELLOW CONTACT CLOSURE SHUNT J7 Figure 2 J7 SW6 SW5 3 3 2 2 1 1 RESET Factory Setting Normally Open (N.O.) Normally Closed (N.C.) 17

E Software Settings for Kaba s Stand-Alone Access Controller (SAC) E-1.. When configuring the E5070 series SAC using the optional.. Standard Software, choose the box that contains Entry Lock.. with Passage (Cylindrical or Mortise without Deadbolt) during.. lock setup. E-2 When configuring the E5270/5770 series SAC using the... mandatory ACS Software, select the Cylindrical or Mortise.. without Deadbolt box during lock setup. F Hard Reset Procedure for Kaba s Stand-Alone Access Controller (SAC) F-1.. A hard reset may be necessary if the master code for the lock.. is lost. A hard reset erases all user codes including the master user and all lock parameters go back to factory default. See the Operations Manual for information on other.. types of resets that can be performed at the ACU s keypad... This procedure requires two people within hearing range of.. each other to verify the sequence below. One person must.. have access to the Lock Interface board assembly inside the.. PIU enclosure on the secure side and another person must be.. located at the ACU unit on the non-secure side of the door... Steps 2, 3, and 4 below must be completed within 5 seconds 1. Person 1: Unlock and open cover to PIU unit 2. Person 1: Slide the TOP switch of SW6 on the PIU s Lock.. Interface board to ON (See Figure 3) 3. Person 2: Press the # key on the ACU s keypad 4. Person 1: Slide the TOP switch of SW6 on the PIU s Lock.. Interface board to OFF and close cover on PIU unit 5. Person 2: Observe Green and Red LEDs flashing on ACU 6. Person 2: Press 1-2-3-4-5-6-7-8 on Keypad, then press # 7. The ACU is now in Factory Default Setup 18

SAC INTERFACE (IN P.I.U.) CONTROLLER INTERFACE J5 CONTACT CLOSURE BLACK RED + ALARM LOCK INTERFACE J6 RED BLACK ORANGE WHITE BLUE GREEN PURPLE J7 YELLOW CONTACT CLOSURE SHUNT 1 2 SW6 N O (TOP) (BOTTOM) SW6 SW5 Figure 3 RESET Notes For technical assistance please call 1.800.849.TECH (8324) or 336.725.1331 19

Kaba Access Control 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849.8324 (336) 725.1331 Fax: (800) 346.9640 (336) 725.3269 For Technical Assistance Tel: 1.800.849.TECH (336) 725.1331 www.kabaaccess.com PKG3239 0808