SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

Similar documents
SecuriFire SecuriLine extended board B5-DXI2

SecuriFire 500. Mounting and Installation. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

BX-MDI8 Input module for SecuriLine extended

Sonos-SB Siren/Beacon

ASD 535 Aspirating Smoke Detector

SecuriFire 500/1000/2000/3000

SecuriFire fire detection systems. System description

ASD 533 Aspirating Smoke Detector

ASD 535 Aspirating smoke detector

ADW 535 Line type heat detector

ASD 535 Aspirating Smoke Detector

ASD 535 Aspirating Smoke Detector

SecuriFire 500/1000/2000/3000

Schrack Seconet Fire Alarm Systems.

Universal fault annunciator for panel mounting

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ASD 532 Aspirating Smoke Detector

SecuriFire FCP 500 Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ASD 531 Aspirating Smoke Detector

Fire control panels FC360

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Fire alarm system EBL512 G3

RAYCHEM NGC-30 COMPONENTS

Planning Instructions MEW01776 Revision -

Interface Modules for SENTRI

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

IntesisBox BACnet/IP Server - Notifier ID3000 series

Control and Indicating Equipment

1. MAIN CONTROL UNIT MCU Accessories for MCU OPERATING AND DISPLAY PANELS... 10

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

On the job around the clock 24/7: Fire detection systems

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Interface and EOL Modules 8

SecuriSens LIST Product Catalogue 2015

600 Range Dialer Installation Manual. Version 1.0

High-precision aspirating smoke detectors for every requirement.

Fire control panel detect 3004 plus and accessories

FP120-Z1 Power supply kit A (70 W) Technical Manual

ASD 531 Aspirating Smoke Detector

Engineering Guideline. pac- Carriers Type Universal

FC700A Fire detection control unit

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

ME 3011C / Alarm Indication / Quick Reference Guide

Synova TM product catalog.

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Fire control panels FC726 FC726-XA

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDCL221 Line separator

CODESEC FIRE ALARM SYSTEMS. security technologies

SecuriRAS ASD 535 Product Catalogue 2015

Danfoss gas detection Controller unit

ARGUS Smoke Detectors. The next generation. Safety and security electronics

ASD 531 Aspirating Smoke Detector

PRELIMINARY EDITION

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Planning Instructions MEW01090 Revision 4

Sinteso TM product catalog.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

OOH740, OOHC740 Automatic fire detectors

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

APPLICATION DATA SHEET

Building Technologies. FDUL221 en Line tester operating instructions for electricians

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Ethernet General Purpose

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Call stations and extensions

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

compact office 24V compact office 24V Lux

SCR100 User Manual. Version:1.1 Date:Dec 2009

Basic Fire Alarm SystemTraining. Arman Alnasar

M2500 Engine Controller Installation Manual

Intelligent Addressable Fire Alarm System

Rules for Intruder Alarm Systems

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Remote alarm indicator and test combination MK2430

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

FC723 Fire control panel

UNC100 Integra Manual

FC724 Fire control panel

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

RS485 MODBUS Module 8AI

Barrier. ED /07/09 Release to production R.P. A ECO N DATE DESCRIPTION OF CHANGE CHG By ISSUE TITLE TC842B1007 AE PRODUCT SPECIFICATION

HRX Technical Manual. Version 1.2

FC724 Fire control panel

SITESTAR CABINET DESCRIPTION

Original operating instructions Safety switch with guard locking AC901S AC902S

Laser Distance Sensor Type M Analog-Output

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

FDCW241 Radio gateway Mounting

Fire & Security Products. Cerberus D100 Multifunctional process control for company security

Planning Instructions MEW00443 Revision -

561-MB256 plus. Intruder alarm control panel. Performance features

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Operation Manual Part-No

RVP310. Heating Controller. Building Technologies HVAC Products

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Transcription:

SecuriFire SecuriLine Unit B6-LXI2 Technical Description Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 8 067 en

Imprint Imprint This document, T 8 067, is valid only for the product described in Section. This document is subject to change or withdrawal without prior notice. The validity of the statements made in this document applies until the statements are revised by a new edition of the document (T number with new index). The user of this document is responsible for staying up to date with the current status through the editor/publisher. We accept no responsibility for claims against any incorrect statements in this document which were unknown to the publisher at the time of publication. Handwritten changes and additions are not valid. This document is protected by copyright. Foreign language documentation as listed in this document is always released or changed at the same time as the German edition. If there are inconsistencies between the foreign language documentation and the German documentation, the German documentation is binding. Some words in this document are highlighted in blue. These are terms and designations which are the same in all languages and are not translated. Users are encouraged to contact the editor/publisher if there are statements which are unintelligible, misleading, incorrect, or if there are errors. Securiton AG, Alpenstrasse 20, 3052 Zollikofen, Switzerland This document, T 8 067, is available in the following languages: German T 8 067 de English T 8 067 en French T 8 067 fr Current edition: 06.09.202 Rd Reference document: B6-LXI2, V.0 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 3 / 7

Safety information Safety information Provided the product is deployed by trained and qualified persons in accordance with this document (T 8 067) and the hazard, safety and general information in this technical documentation is observed, there is no danger to persons or property under normal conditions and when used properly. National and state-specific laws, regulations and guidelines must be observed and adhered to in all cases. Below are the designations, descriptions and symbols of general, danger, and safety information as found in this document. Danger If the Danger notice is not properly observed, the product and other system parts may present a hazard for persons and property, or the product and other system parts may be damaged to the extent that malfunctioning results in danger to persons and property. Description of which dangers can occur Measures and preventative actions How dangers can be averted Other safety-relevant information Warning The product may be damaged if the safety information is not heeded. Description of which damage can occur Measures and preventative actions How dangers can be averted Other safety-relevant information The product may malfunction if this notice is not observed. Description of which malfunctions can be expected Measures and preventative actions Other safety-relevant information Environmental protection / recycling Neither the product nor product components present a hazard to the environment provided they are handled properly. Description of which parts have environmental protection issues Description of how devices and their parts have to be disposed of in an environmentally-friendly way Description of the recycling possibilities 4 / 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en

Document history Document history First edition Date 06.09.202 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 5 / 7

Contents Contents General 9. Validity 9.2 General 9.3 Compatibility notice 9 2 Design and function 9 2. Overview 9 2.2 Interfaces 0 2.2. Loop interface (X2) 0 3 Programming and planning 3 4 Fault displays 3 5 Connection examples 3 5. SecuriLine connection extended 3 5.2 Stub line connection 4 5.3 SecuriLine extended modules connection 4 6 Technical data 6 7 Article numbers / spare parts 7 8 List of figures 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 7 / 7

Contents General. Validity The following documentation is valid for the SecuriFire B6-LXI2 SecuriLine Unit with edition 20-00002-0-0..2 General The B6-LXI2 (Dialog Analog Interface) can be fitted to the B6-BCB3 main control unit of the SCP2000 if required and serves to connect two additional SecuriLine extended loops with their associated detectors and modules. In addition, the module has a LAN interface..3 Compatibility notice The B6-LXI2 is supported beginning with SecuriFire Studio V.2. The B6-LXI2 meets both the specification of SecuriLine extended as also that of SecuriLine. 2 Design and function The B6-LXI2 SecuriLine Unit is used for power supply and evaluation of two addressable loops with the associated detectors and modules of the SecuriLine extended. Alternatively, an addressable loop and two stub lines or four stub lines can also be connected. In addition, the module has a LAN interface. Thus even with 4 loops, all options of the LAN interface (ISP-IP for connecting alarm management systems, VirtualMIC, remote access, etc.) can be used. 2. Overview The B6-LXI2 printed circuit board can be used as an option to the SCP2000. The system connection to the B6- BCB3 is on the rear side with a 48-pin male connector. The fire detection lines are connected on the front side with a 6-pin plug-in screw terminal. Fig. B6-LXI2 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 9 / 7

Design and function 2.2 Interfaces X Interface for the B6-BCB3 main control unit X X2 Connection plug for 2 addressable loops or 4 stub lines X3 Connection plug for the LAN-Interface (RJ45) X3 X2 6 Fig. 2 Interfaces to the B6-LXI2 2.2. Loop interface (X2) The B6-LXI2 is designed for connecting 2 addressable loops. Each loop interface has its own current-limited output driver which supplies the connected loop with power. There is only one transmission and reception part per loop. When it is operated as a stub, communication alternates between the two stubs. Logical limitations: The number of elements per loop depends on the type of used/connected elements and is logically limited. One panel can manage in sum 768 zones, outputs and inputs. Physical limitations: The actual loop length depends on the number and type (power consumption, inner resistance) of participants, on additional power load (number of switched on alarm LEDs, telegram current), and on the cable crosssection. This means that for the optimal configuration the number of participants and the coverage range of the loop must be matched to each other. A tool is available for calculating the maximum possible loop length and the maximum number of participants. 0 / 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en

Design and function Connection SecuriLine extended SecuriLine Addressable loops per board: max. 2 Stubs per board: max. 4 Main processing units: B6-BCB3 Participants per loop: max. 250 max. 28 Participants per stub: max. 64 max. 64 Logical elements: max. 768 / B6-LXI2 Modules: ) BX-AIM, BX-IM4, BX-IOM, BX-OI3, BX-O, BX-I2, BX-REL4,BX-RGW SDI8X, SDI82X BA-AIM, BA-IM4, BA-IOM, BA-OI3, BA-REL4,BA-RGW SDI8, SDI82, COM8, SLI5A, SLM35 Detectors: MCD 573X, MCP 535X, MCP 545X MCD 573, STD 53, SSD 53, UTD 53, MCP 535, MCP 545 Alarm units: BX-SOL, BX-FOL, BX-SBL 50, BX-SBL 502, BX-API BA-SOL, BA-FOL, SBL 50, SBL 502, BA-API Loop length: max. 3 500 m max. 2 000 m Max. line resistance: 255 Ω 50 Ω ) The maximum number of connectable modules is found in these documentations: SF-AI-04 or SF-Release-Notes The properties of the SecuriLine extended (e.g. 250 participants per ring) apply only when SecuriLine extended elements are used. Since the SecuriLine extended elements are backwards compatible, mixed operation with elements of SecuriLine is also possible; in this case, however, the performance features of the conventional Se-curiLine apply to the ring. Loop connector plug (X2) Loop mode of operation Stub mode of operation Loop no. Designation Function Stub no. Designation Function 2 Not available Not available G4 Screen G4 Screen 4 C4 loop end C4 stub 4 L4 +24 V loop end L4 +24 V stub 4 Not available Not available G3 Screen G3 Screen 3 C3 loop beginning C3 stub 3 L3 +24 V loop beginning L3 +24 V stub 3 Not available Not available G2 Screen G2 Screen 2 C2 loop end C2 stub 2 L2 +24 V loop end L2 +24 V stub 2 Not available Not available G Screen G Screen C loop beginning C stub L +24 V loop beginning L +24 V stub B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en / 7

Design and function Electrical: Loop voltage: +30 V ±3 % Loop current: 50mA max. Short-circuit current: 232mA typ. Loop length: max. 3500m (according to loop length calculation) max. line resistance 255 Ω Transmission type: Start-stop operation, 8 data bits Manchester format Baud rate: 9 600 Baud / 4 800 b/s Direction: Bidirectional Cable: J-Y(St)Y x2x0.8 rt; pair, screened, twisted Capacity: max. 20 nf / km Line capacity: max. 350 nf Protection: EMC, ESD by means of Transzorp diodes and high-voltage capacitors Mechanical design: 6-pin plug-in screw terminal, max..5mm 2 LAN Interface (X3) Pin Function TX+ 2 TX- 3 RX+ 4 Termination 5 Termination 6 RX- 7 Termination 8 Termination Connection: Transmission type: Direction: Protection: Mechanical design: Ethernet 0/00 BaseTx TCP/IP Bidirectional, full duplex EMC, ESD by means of high-voltage capacitors RJ-45 connector, 8 pin 2 / 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en

Programming and planning 3 Programming and planning SecuriFire software documentation for programming and planning is in preparation. 4 Fault displays The plain text information of a fault code can be called up with the Additional info MIC button (magnifying glass). 5 Connection examples 5. SecuriLine connection extended All modules and detectors of the SecuriLine extended are fully symmetrical with respect to the input circuit and short-circuit isolators. When wiring, it is therefore unimportant from which side of the loop INCOMING and OUTGOING are connected. For purposes of clarity, however, we recommend continuing with one wiring system once begun. 6 5 4 3 2 MCP 545X MCP 545N MCP 545 USB 50 6 5 4 3 2 4 3 L 2 8 7 L2 6 5 6 5 L2 4 3 2 L B6-BCB2 (X2) B6-BCB3 (X2) B6-LXI2 (X2) B5-DXI2 (X2) SCHIRM BX-AIM / BA-AIM BX-OI3 / BA-OI3 BX-REL4 / BA-REL4 BX-IOM / BA-IOM BX-IM4 / BA-IM4 BX-RGW / BA-RGW BX-FOL / BA-FOL BX-SOL / BA-SOL BX-ESL BX-O2I4 BX-SBL50 / SBL50 BX-SBL502 / SBL502 BX-I2 BX-O XLM35 L2 L XY 2 3 4 5 6 7 8 L MCP 535 MCP 535X L2 Fig. 3 SecuriLine extended connection B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 3 / 7

Connection examples 5.2 Stub line connection According to EN 54 standards max. 32 detectors (sum of automatic + manual detectors) must be installed on a stub line. 5 4 3 6 2 6 5 4 3 2 6 5 4 3 2 B6-BCB2 (X2) B6-BCB3 (X2) B6-LXI2 (X2) B5-DXI2 (X2) 6 5 4 3 2 6 5 4 3 2 6 5 4 3 2 USB 50 USB 50 USB 50 L2 8 7 6 5 L 4 3 2 L2 8 7 6 5 L 4 3 2 L2 L 6 5 4 3 2 MCP 545X MCP 545N MCP 545X MCP 545N Fig. 4 Stub line connection MCP 545 5.3 SecuriLine extended modules connection The BX-AIM advanced input module functions as a DC-line branch on the addressable loop and can be planned either as a monitored input for polling potential-free contacts or as a detection zone for connecting collective detectors. Among other things, it serves to connect intrinsically safe threshold detectors (Ex-i) with intermediate (in-line) switching of a Zener barrier; the module also has an output for a parallel indicator. The BX-OI3 output/input module can be planned either as an output/input module (x relay output, 2x monitored inputs, x opto-isolator) or as a detector or detection zone for connecting special detectors. The BX-REL4 relay module has 4 potential-free relay outputs for switching loads. All relays are bistable changeover contacts and each one has a screw terminal for the normally closed contact and normally open contact. For each output an Aktiv in Fail-Safe-Lage can be programmed in the event of loop voltage failure. The BX-IOM input/output module has a monitored output and a galvanically isolated input. It is for actuating monitored consumers (e.g. sirens) which are supplied with power from external voltage sources. The input can be used to poll potential-bound voltage sources. The BX-IM4 input module has 4 inputs for monitored and unmonitored polling of potential-free contacts. 4 / 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en

Connection examples The input module BX-I2 contains one primary input for polling potential-free contacts and one opto-isolator input, which can be used for monitoring an external voltage if necessary. The output module BX-O comprises a potential-free relay output for switching loads of up to 2 A and up to 230 V. The BX-RGW radio module serves to link radio detectors to the fire alarm control panel. The BX-FOL addressable loop flashlight serves to visually signal a fire alarm in interior rooms and is suitable for connecting directly to the X-LINE. The BX-SOL addressable loop siren serves to audibly signal a fire alarm in interior rooms. The BX-SBL 50 loop design base and the BX-SBL 502 loop ceiling siren audibly signal a fire alarm in interior rooms. BX-AIM / BA-AIM BX-OI3 / BA-OI3 BX-REL4 / BA-REL4 BX-IOM / BA-IOM BX-IM4 / BA-IM4 BX-RGW / BA-RGW BX-FOL / BA-FOL BX-SOL / BA-SOL BX-ESL BX-O2I4 BX-SBL50 / SBL50 BX-SBL502 / SBL502 BX-I2 BX-O XLM35 L2 L X2 L2 L Fig. 5 Connecting SecuriLine extended modules Further information and detailed descriptions of how to connect the SecuriLine extended modules are found in the relevant technical documentation. B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 5 / 7

Technical data 6 Technical data Power supply The power supply of the B6-LXI2 SecuriLine unit is internal via the B6-BCB3 main control unit. Supply voltage:: VCC +3,4 V ±2 % VCC 2 +5, V ±2 % Power consumption: ICC approx. 3 ma Power requirement In the event of a power failure, the fire alarm control panel is powered by batteries. Depending on the configuration and connected peripheral devices (unit, detectors, sirens, etc.), it is important to ensure that the batteries have sufficient capacity to operate the fire alarm control panel for the specified time (e.g. according to a standard or directive). For the power requirement calculation there is a power calculation tool in which the battery types in use and the necessary bridging time (according to local standards and directives) are entered. Ambient conditions Ambient temperature: Relative humidity: Air pressure: Contact protection: -5 C to +50 C, measured at natural convection under the unit 5% to 95% without condensation 80 kpa, up to 2,000 m above sea level IP00, no protection against contact, foreign matter or water EMC: EN 5030-4 Electromagnetic compatibility EN 5008- Emission standard for residential environments EN 50082-2 Immunity for industrial environments EN 55022 Radio disturbance characteristics VdS 20 Schutz gegen Umwelteinflüsse Norms: EN54-7, EN54-8 Security: VDE 0800 Telecommunications Security VDE 0804 Telecommunications Additional definitions EN60950- Safety Part : General Requirements Dimensions Unit (H x D x W): 42,5 x 93,5 x 8 mm 6 / 7 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en

Article numbers / spare parts 7 Article numbers / spare parts Short designation Swiss art. number Art. number SecuriLine unit B6-LXI2 5.2488 20-00002-0-0 Connector plug ST-LOOP/DAI 239.2463 YK30295 8 List of figures Fig. B6-LXI2... 9 Fig. 2 Interfaces to the B6-LXI2... 0 Fig. 3 SecuriLine extended connection... 3 Fig. 4 Stub line connection... 4 Fig. 5 Connecting SecuriLine extended modules... 5 B6-LXI2 SecuriLine Unit, Technical Description, T 8 067 en 7 / 7