fmap Log / Troubleshooting Manual Release 8.0 Issue 1

Similar documents
SimpleComTools, LLC 1

Alarm Monitoring and Management

Configuring and Monitoring Alarm

Alarms for the Cisco ISA 3000

Alarm Monitoring and Management

Alarm Monitoring and Management

Monitor Alarms and Events

Simplex Panel Interface Guide

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

Alarm Monitoring and Management

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

RAy SNMP. Application notes.

UAS 7000 Local Management

Common Alarms CHAPTER

Contact Product Manager, with details of the application.

FCD-wire Contents. List of Figures

Digivance CXD/NXD Element Management System EMS. User Manual ADCP Part Number Rev A Issue 1

Managing Network Alarms and Events

Avaya Proactive Contact Release 5.x

USER MANUAL FOR OPERATING SYSTEM

Batt-Safe Battery String Monitoring System

Added password for IP setup page : Password must be in IP format!

QS941A Controller User Interface

Monitor Alarms and Events

Trident User s Manual

Making the Most of Alarms

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Power Management and Environmental Monitoring

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Setting up and Managing Alarms in McAfee ESM 10.x

FlameGard 5 UV/IR HART

Manage Alarms. Before You Begin CHAPTER

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/

IRIS Touch Firmware Enhancements and Additions from Version to Version

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Yokogawa DX Ethernet Driver Help Kepware Technologies

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

Manage Alarms. Before You Begin CHAPTER

Thresholding Configuration Guide, StarOS Release 16

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

Installer Certification Expiration. Terms

Model 135 Reference Document

I-HUB Chassis. Operation Manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

DTSX200 Communications(Modbus) Guide

Galaxy Pulsar Plus Digital Battery Plant Controller

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Alarm setup and definitions in Cisco Unified Serviceability

Bosch TCU Integration Module Administrator's Guide

Sensaphone 400 Telemetry System Integration

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

BTI7800 Series Alarm and Troubleshooting Guide

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

F Technical Bulletin SC 370 SMART Modbus Interface

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER

Alarm module for leak detection with webserver

HERCULES 6 GRAPHICS SYSTEM

Innovative Circuit Technology Ltd.

For Raychem ACS-30 Controls Systems

COMMUNICATOR ET08 / ET081

Subscriber Data Management

MicroTech Series 200 Centrifugal Chiller

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

Cisco Transpath TP MIBs

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Oracle Communications Performance Intelligence Center

Advanced Power Monitor (APM)

LineGuard 2300 Program User Manual (FloBoss 107)

FlameGard 5 MSIR HART

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071

Using ANM Mobile CHAPTER

Innovative Circuit Technology Ltd.

Modbus TCP/IP Option Instruction Manual

ECO N DATE DESCRIPTION OF CHANGE CHG

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

C&I SYSTEM DIAGNOSTICS WITH SELF MONITORING AND REPORTING TECHNOLOGY (SMART)

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

DAP III Zone Master User s Guide

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

Fire Alarm Network Reference

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Advanced Features Guide of Visual MIBrowser Pro

FortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Lighting Xpert Insight User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ESAC ebacgw Tecnoalarm

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Customer Training Catalog Course Descriptions Network OSS Training

Alarm handling by SMS in ALERT

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Transcription:

613-000626 Rev.A 061006 fmap Log / Troubleshooting Manual Release 8.0 Issue 1 2006 Allied Telesis Holdings K.K. All rights reserved. Information subject to change without notice.

About this Manual This manual includes all log messages produced by the fmap products, helps to isolate any problems associated with the log message and alarm to a specific component, and provides steps to repair or replace the component and clear the log message or alarm. Section 1 provides an overview of how the log message and alarm system is designed so that messages and alarms are generated at the local, remote (server), and NMS interfaces. Section 2 lists all of the log messages produced by the fmap products and includes their associated Log Categories (such as CARD005), as well as Traps and Reason Codes. From this list the user can understand the scope of the problem and know which components to test. Section 3 lists the alarm messages (usually the Reason Code/Alarm Message) of the log and associates it with the specific log, the status of the alarm, and the status of the card LEDs. Sections 4 lists the traps/mib specifications for fmap devices. Highlighted are whether a MIB and an associated trap come from standards or from a fmap MIB. 2006 Allied Telesis Holdings K.K. All rights reserved. Information subject to change without notice. ii

Table of Contents 1 Overview of Logs / Alarms System- - - - - - - - - - - - - - - - - - -1-1 1.1 Interfaces for Communicating with Devices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-1 1.2 Types of Alarm Indicators - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-3 1.2.1 Alarm Severity- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-3 1.2.2 Port Outage Threshold Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-5 1.2.3 Logs- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 1.2.4 Relationship of Logs and Traps with Device Interfaces- - - - - - - - - - - - - - - - - - - - - 1-7 1.2.5 CARD and PORT Logs (Information, Degrading and Failing Conditions) - - - - - - - - 1-7 1.2.6 LED- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-7 2 Interpreting Log Messages - - - - - - - - - - - - - - - - - - - - - - - -2-1 2.1 Log Formats - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-1 2.1.1 Log Messages from the CLI- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-1 2.1.2 Examples - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-1 2.2 Log Message Reference- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-3 2.3 Network Loops - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-3 Telesyn Log / Troubleshooting Manual (Table of Contents)

TOC-2 Telesyn Log / Troubleshooting Manual (Table of Contents)

1. Overview of Logs / Alarms System 1.1 Interfaces for Communicating with Devices To receive event and alarm indicators from the fmap devices, interfaces must have been configured so that these indicators are sent to the proper place and are filtered when necessary. This Section provides an overview of these interfaces. Note: It is assumed that the user has set up the interfaces described in this Section and can readily communicate with the system through the MGMT or inband upstream port. However, a condition or conditions may exist where the user cannot communicate with the system or the user is not receiving logs on their configured log server or the NMS. If the condition(s) cannot be cleared, the user should contact Allied Telesis Technical Support. 1.1.0.1 fmap Figure 1-1 shows the physical and protocol interfaces that allow the fmap product to communicate with management systems. One of two IP interfaces can be used: The MGMT Ethernet interface that transports only management data packets. An in-band Ethernet interface that interleaves user data packets with management data packets on the uplink, using a VLAN interface. In using a VLAN interface the management data packets are always VLAN-tagged. Over these two interfaces, the TELNET or SNMP agent can be configured. Note: Only one interface can be enabled at a time; enabling an interface will disable an interface already enabled. If necessary, the ENABLE IP INTERFACE command will automatically disable the other IP Interface. 1-1

Interfaces for Communicating with Devices FIGURE 1-1 Connections for Management Interfaces for the fmap To enable TELNET access for the management ethernet interfaces, TELNET must be enabled. The user can then choose which interface to use and supply the IPADDRESS and SUBNETMASK for the fmap product that will be used by the management device when a user logs in. Note: These interfaces should be set up using the local RS232 interface. See the following Caution. If the user disables or deletes an IP interface, and the user is currently using that interface to communicate with the fmap product, the interface will be immediately disconnected. 1-2

Alarm Severity Types of Alarm Indicators 1.1.0.2 PING The system provides the user with the ability to ping network devices from the CLI command line interface. An example of the PING command: officer SEC> PING 172.16.17.18 officer SEC> PING 172.16.17.18 (172.16.17.18) 64 bytes from 172.16.17.18 (172.16.17.18): icmp_seq=1 --- 172.16.17.18 ping statistics --- 1 packets transmitted, 1 packets received, 0% packet loss TABLE 1-1 PING command Noun Verb Syntax Description PING PING PING={ipaddress hostname} [DELAY=1..900] [LENGTH=1..65535] [NUMBER={1..65535 CONTINUOUS }] [TIMEOUT=1..900] The PING command provides the user with the ability to determine whether a network device is accessible or not. 1.2 Types of Alarm Indicators When the OAM system is configured as described in Chapter 3 of the fmap User Guide, indicators for faults or potential faults are easy to generate, store, and output. The OAM system produces the following event and alarm indications: logs, Traps, and LED alarm indicators. These events are described in more detail below. 1.2.1 Alarm Severity Allied Telesis system alarms are organized by order of severity level. They are Critical, Major, and Minor. Each level is described here. 1.2.1.1 Critical Critical is the highest, most sever level of alarm. An alarm with a severity level of critical means that system service is being detrimentally affected. It requires the user s immediate attention. When a critical alarm conditions is raised, the CRIT LED on the CFC faceplate will be illuminated. The FAULT LED on a card faceplate may also be illuminated. A log indicating a critical alarm will be prefaced by *C as the first two characters in the first line of text. An example of a critical alarm log is illustrated below. 1-3

Types of Alarm Indicators Alarm Severity *C SYS009 2003-12-04 13:29:57 0327 FAULT System: Raised Port Outage Threshold FIGURE 1-2 Critical alarm log 1.2.1.2 Major Major is the second highest level of alarm. An alarm with a severity level of major means that system service may be affected. The user must immediately investigate a major alarm. When a major alarm conditions is raised, the MAJOR LED on the CFC faceplate will be illuminated. The FAULT LED on a card faceplate may also be illuminated. A log indicating a major alarm will be prefaced by ** as the first two characters in the first line of text. An example of a major alarm log is illustrated below. ** PORT003 2003-12-04 13:30:04 0356 FAULT Location: Slot: 5 Port: 1 Description: Port Fault Set Reason Code: Loss Of Link FIGURE 1-3 Major alarm log 1.2.1.3 Minor Minor is the lowest level of alarm. An alarm with a severity level of minor means that system service is not affected. However, this alarm condition could lead to a major or critical alarm condition; therefore, the user should investigate the alarm. When a minor alarm conditions is raised, the MINOR LED on the CFC faceplate will be illuminated. The FAULT LED on a card faceplate may also be illuminated. A log indicating a minor alarm will be prefaced by * as the first character in the first line of text. An example of a minor alarm log is illustrated below. * SYS009 2003-12-04 15:20:31 2669 FAULT System: Raised Port Outage Threshold FIGURE 1-4 Minor alarm log Some alarm conditions begin as a minor alarm, but as the alarm condition continues, its level will be raised. For example, a port outage threshold alarm may initially be raised as a minor alarm. However, if more ports encounter the same alarm condition and the number of ports in alarm increases, after a certain threshold is reached, the alarm will become a major alarm. Furthermore, if the alarm condition continues and even more ports encounter 1-4

Port Outage Threshold Configuration Types of Alarm Indicators the same alarm condition and the number of ports in alarm increases, after a third threshold is reached, the alarm will become a critical alarm. Thresholds for this example, a port outage, are: Minor - Less than 24 downstream ports are impacted by card failures and there is at least one uplink available. Major - More than 24 but less than 128 downstream links are impacted by card faults and there is at least one uplink available. CRITICAL - More than 128 downstream ports are impacted by card faults and/or there is no uplink available. 1.2.2 Port Outage Threshold Configuration In release 4.0, port outage thresholds can be configured by the Allied Telesis system user. Alarms can be configured to be either MAJOR, MINOR, or CRITIAL. An example follows: officer SEC>> SHOW ALARMS THRESHOLD Threshold Mark -------------------------------------- MINOR 1 MAJOR 24 CRITICAL 128 officer SEC>> SET ALARMS THRESHOLD MINOR=7 MAJOR=32 CRITICAL=96 Warning(033613): 6 ports can go out of service before an alarm is raised if the MINOR threshold is 7. Threshold Mark -------------------------------------- MINOR 7 MAJOR 32 CRITICAL 96 Info (010017): Operation Successful officer SEC>> SETDEFAULTS ALARMS THRESHOLD Threshold Mark -------------------------------------- MINOR 1 MAJOR 24 CRITICAL 128 Info (010017): Operation Successful officer SEC>> SHOW ALARMS THRESHOLD 1-5

Types of Alarm Indicators Port Outage Threshold Configuration Threshold Mark -------------------------------------- MINOR 1 MAJOR 24 CRITICAL 128 Note that the system will default to known thresholds if they have not been configured. Defaults are: MINOR - Less than or 24 ports MAJOR - 25-127 ports CRITICAL - More than 128 ports TABLE 1-2 Port Outage Thresholds commands Noun Verb Syntax Description ALARMS THRESHOLD SET SET ALARMS THRESHOLD [ MINOR=value ] [ MAJOR=value ] [ CRITICAL=value ] The alarm thresholds control when the MINOR, MAJOR, and CRITICAL Port Outage Threshold alarms are raised. The values must be non-zero and satisfy the condition of MINOR, MAJOR, or CRITICAL. These signify the lowest number of ports for that alarm to be raised. Critical - Minimum number of ports before a CRITICAL alarm is raised. Major - Minimum number of ports before a MAJOR alarm is raised. Minor - Minimum number of ports before a MINOR alarm is raised. Setting minor to anything greater than one is allowed, but not recommended.that means that (MINOR - 1) ports can be out of service before the threshold alarm is raised. Note: When all UPLINK ports are out of service, a CRITICAL alarm will be raised regardless of the threshold values. ALARMS THRESHOLD SETDEFAULTS SETDEFAULTS ALARMS THRESHOLD This command sets all alarm threshold values back to the factory defaults. ALARMS THRESHOLD SHOW SHOW ALARMS THRESHOLD Displays the current settings for port alarm thresholds. 1-6

Logs Types of Alarm Indicators 1.2.3 Logs fmap products provide totally flexible logging functionality. Refer to the fmap User Guide, Section 4, for detailed descriptions of the log system and instructions for configuring log output. Refer to Section 2 of this document for a description of the log output and a listing of all the logs produced by the fmap devices. 1.2.4 Relationship of Logs and Traps with Device Interfaces Since there are multiple ways to report a device status as well as multiple interfaces to display them, the following summarizes how they are related: Traps are produced and associated with: Standard (RFC-based) MIBs ATN Enterprise (ATN Enterprise MIB and Ext. Eth. DS3 MIB) These are the fmap products All traps produce logs, and these logs have associated log messages, reason codes, and severities. Some logs, on the other hand, do not have an associated trap. These are usually for status or update information. 1.2.5 CARD and PORT Logs (Information, Degrading and Failing Conditions) The two most common logs for card and port logs are CARD023, CARD005, PORT013, and PORT003 logs. CARD023 logs are intended to indicate INFO conditions that do not affect state, such as file corruption, database upgrade, multicast stream limit, and inconsistent load. CARD005 covers all failing and degrading conditions. Note: Both of those logs generate the same SNMP trap. PORT005 logs are for degrading conditions, and PORT013 is informational only. 1.2.6 LED These products are equipped with LED alarm indicators on the front panels of system cards. See the fmap Component Specification for detailed descriptions of system LEDs. The following table lists and describes the LED alarm indicators for each card type 1-7

Types of Alarm Indicators LED Note: In the specific procedures, the alarm LEDs are included since they help to isolate the faulty component. The user should, however, study and refer to this table since they help in understanding the overall system design. TABLE 1-3 LED indicators Card Type LED Meaning Notes ADSLn / PULL n/a The card has been disabled, is out of service and can be removed for replacement. Note: All subscribers provisioned on this card are now out of service. FAULT Minor, Major, Critical A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: All subscribers provisioned on this card may be experiencing a service interruption. INSRV n/a The card has been enabled and is in service. 1-8

LED Types of Alarm Indicators TABLE 1-3 LED indicators (Continued) Card Type LED Meaning Notes CFCn PULL n/a The card has been disabled, is out of service and can be removed for replacement. Note: If the system is configured for simplex mode, all subscribers are now out of service. FAN8 Fan Controller FAULT See Minor, Major, Critical LEDs A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: If the system is configured for simplex mode, all subscribers may be experiencing a service interruption. INSRV n/a The card has been enabled and is in service. ACT n/a For systems configured for duplex mode, this LED indicates that this CFC is Active CRIT Critical A Critical system alarm is present. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: If the system is configured for simplex mode, all subscribers may be experiencing a service interruption. MAJOR Major A Major system alarm is present. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: If the system is configured for simplex mode, all subscribers may be experiencing a service interruption. MINOR Minor A Minor system alarm is present. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: All subscribers provisioned on this system may be experiencing a service degradation. PULL n/a The card has been disabled, is out of service and can be removed for replacement. FAULT Minor, Major, Critical A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. INSRV n/a The card has been enabled and is in service. 1-9

Types of Alarm Indicators LED TABLE 1-3 LED indicators (Continued) Card Type LED Meaning Notes FC7 PULL n/a The card has been disabled, is out of service and can be removed for replacement. FAULT Minor, Major, Critical A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. INSRV n/a The card has been enabled and is in service. Fiber PULL n/a The card has been disabled, is out of service and can be removed for replacement. Note: All subscribers provisioned on this card are now out of service. FAULT Minor, Major, Critical A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: All subscribers provisioned on this card may be experiencing a service interruption. INSRV n/a The card has been enabled and is in service. Link n/a When illuminated, indicates that the port is operationally UP and data traffic is flowing over the port. GEn PULL n/a The card has been disabled, is out of service and can be removed for replacement. Note: If the system is provisioned with a single up link with no standby, all subscribers provisioned are now out of service. FAULT Minor, Major, Critical A fault is present on the card. Check for logs associated with this card and display the fault using the SHOW ALARMS command. Note: All subscribers provisioned on this system may be experiencing a service interruption. INSRV n/a The card has been enabled and is in service. LINK n/a The TCP/IP link is UP. 1-10

2. Interpreting Log Messages 2.1 Log Formats The fmap product produces management logs that provide information about all changes that occur. Figure 2-1 shows an example log. A B C D E F * CARD002 2003-07-13 23:11:24 5618 INFO Location: Slot: 5 Description: Card Mismatch Cleared Reason Code: Card Mismatch Legend: A - Severity B - Category C - Date and Time D - Sequence Number E - Log Type F - Message 2.1.1 Log Messages from the CLI FIGURE 2-1 Sample Log Produced by the fmap product Use the SHOW LOG command to filter logs immediately in the output, for example to show only logs that have a severity of CRITICAL. 2.1.2 Examples Examples of system logs follow: 2.1.2.1 Informational (INFO) logs These logs record events that may have an associated trap. Those that do have a an associated trap are included in this document. Teleysn Log / Troubleshooting Manual (Interpreting Log Messages) 2-1

Log Formats Examples Log Category Date Time Sequence Number Log Type Reason Text USER002 2003-12-03 17:50:52 0927 INFO User: officer at IP: local has logged in FIGURE 2-2 Informational log 2.1.2.2 Fault logs These are the logs that have associated traps as well as reason codes and are the ones included in this document. Log Category Date Time Sequence Number Log Type Reason Text PORT003 2003-12-03 16:46:20 0922 FAULT Location: Slot: 17 Port: 12 Description: Port Fault Set Reason Code: Loss Of Cell Delineation FIGURE 2-3 Fault log 2.1.2.3 Other logs Logs of the type OTHER are for events such as a change of state and are useful for monitoring system activity as the system goes through changes in configuration. Some logs can have associated traps and these are included in this document. 2-2 Teleysn Log / Troubleshooting Manual (Interpreting Log Messages)

Examples Log Message Reference Log Category Date Time Sequence Number Log Type Reason Text PORT015 2003-12-03 16:46:21 0926 OTHER Port Up: Slot: 4 Port 5 2.2 Log Message Reference FIGURE 2-4 Other logs This Log Message Reference lists the trap-associated logs and uses the following attributes: Category - These are explained in Section 1 and include the number within the category. NMS messages have the category NMS. Type - The types possible are FAULT, OTHER, INFO, and PROGRESS INDICATOR. For the NMS, the type is the associated configuration area (such as Discovery). Trap Text - This is the message passed with the log; these are listed in the NMS trap parser. Severity - These are critical, major, minor, and warning. Log Message - This is the text string that specifies the problem, and may include variables that identify a specific component. Reason Code - This can further identify the problem. Overview - This explains the scope of the problem and the possible faulty components. The log messages are listed by Category, Reason Code, and Trap Text. Reading the logs with these attributes allows the user to quickly find the log in this table. 2.3 Network Loops Network loops may be indicated by service degradations, connectivity problems on a link(s), etc. If the user suspects the presence of a network loop, they should attempt to find the loop and correct it. Some things that the user should look at are recent port and interface provisioning, recent EPSR provisioning, recent STP provisioning, and recent wiring and connections made within their network or connections external to their network. Teleysn Log / Troubleshooting Manual (Interpreting Log Messages) 2-3

Network Loops Examples 2-4 Teleysn Log / Troubleshooting Manual (Interpreting Log Messages)