FDCIO223 (ES 45) Transponder

Similar documents
Input module, input/output modules

Input module, input/output module

FDCL221-M Multi line separator module

Multi line separator module

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Output module (230 V)

FDCL221-Ex Line adapter (Ex)

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DC1192 Input /Output module

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DF1101-Ex Infrared flame detector

ASA linear smoke detector

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Mimic display driver, LED ribbon cable

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OOH740, OOHC740 Automatic fire detectors

FC724 Fire control panel

FC722 Fire control panel

OOH740-A9-Ex Multisensor fire detector

FDCIO223 Input/output module (transponder)

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FDCIO223 Input / output module (transponder)

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FC724 Fire control panel

OH720, OP720, HI720, HI722

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DM1131 / DM1133 / DM1134 Manual call points

FC723 Fire control panel

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

OOH740-A9-Ex Multi-sensor fire detector

FC2020 Fire control panel

FDOOT221, FDO221, FDT221

FC722 Fire control panel

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDCL221 Line separator

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FDCW241 Radio gateway Mounting

Synova TM product catalog.

Fire control panels FC726 FC726-XA

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FS20 Fire detection system

Interbases. Sinteso FDSB221, FDSB228, FDSB229

XC10 Extinguishing control panels

Fire control panels FC360

DF1151-Ex Infrared flame detector

Fire control panel for modernization

SWING radio fire detection system

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDL241-9 Linear smoke detector Mounting Commissioning

Sinteso TM product catalog.

FDA241, FDA221 Siemens ASD

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

DT1101A / DT1102A / DO110xA Automatic fire detectors

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDM273 Radio manual call point Mounting

FDBZ290 Air sampling smoke detection kit Technical Manual

DOW1171 / DCW1151 Radio fire detection system

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Test units and accessories

FDOOT241-A9-Ex Automatic fire detector Technical Manual

FS720 Fire detection system (marine) Technical Manual

Radio fire detection system

Test units and accessories

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FD20 Sinteso Detector system

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

XC10 Extinguishing control unit XC1001-A / XC1005-A / XC1003-A. Installation Commissioning Maintenance. Building Technologies. A6V _e_en_--

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

Test units and accessories

FDS229 Alarm sounder with supplementary optical indication Technical Manual

FT2080 Fire terminal (Touch) Mounting Installation

Room thermostat with 24-hour time switch and large LCD

OH110, OP110, HI110 Automatic fire detectors

Electronic timeswitch

FDA241, FDA221 Siemens ASD

Interface and EOL Modules 8

FT2080 Fire terminal (Touch) Mounting Installation

XC10 combined fire detection and extinguishing control

FC700A Fire detection control unit

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Duct Temperature Sensors

Fire safety products and accessories siemens.com/cerberus

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

XC10 combined fire detection and extinguishing control

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Room Temperature Controllers

DICTATOR Hold-Open Systems for Hazardous Areas

Cerberus ECO. Fire Safety Products and Accessories. Product Catalogue. siemens.com/buildingtechnologies

SINGLE MONITORED INPUT UNIT BN-303

RVL479. Heating Controller. for use with a partner unit

Flush-mounted room thermostat

Transcription:

FDCIO223 (ES 45) Transponder Addressed (FDnet/C-NET) Sinteso Cerberus PRO 2 monitored inputs/outputs, which can optionally be used as a detector line (collective Siemens/Cerberus, Synova 600, or collective Synova 300), contact input, control output, or as a control output with confirmation LED indicator for input/output statuses, fault, test, etc. DC 24 V control output for equipment, max. 1 A Two-wire installation for all cable types Pluggable connection terminals DC 24 V power supply, external (detector lines electrically isolated) Microprocessor-controlled signal processing Communication via FDnet/C-NET (addressed individually) Can be used in dry, dusty, and humid areas Different mounting options Control Products and Systems

Properties Eco-friendly Environmentally friendly processing Recyclable materials Electronic parts and synthetic materials can be easily separated Features Transparent housing, ensuring that indicators are easy to see Protected electronics Integrated line separator Easy mounting using snap fastener Can be used in dry areas Use additional housing for dusty and humid environments Transponder FDCIO223 Function The 2 inputs/outputs can be configured independently of one another as follows Collective detector line Contact input Control output Control output and input as confirmation with selectable monitoring window The inputs/outputs are monitored as follows Detector line set to quiet, alarm, open line, short-circuit, fault, and ground fault Contact input set to quiet, activated, open line, short-circuit, fault (terminating resistor), and ground fault Control output set to quiet, open line, short-circuit, and ground fault Status indicator by means of LED Control output with selectable equipment monitoring, either identical polarity or reverse polarity (e.g., alarm devices) Use For connecting to collective fire detectors (GMT line, GMT line with safety barrier (SB3) for areas at risk of explosion) For monitored control of smoke dampers, alarm devices, door magnets, and extinguisher triggering devices (observe country-specific regulations) As a monitored signal input for status or alarm messages, or for confirming technical statuses 2

FDnet/C-NET DC 24 V external Collective GMT detector, Siemens, Synova SynoLINE600 or SynoLINE300 2 inputs/outputs with the option to use as a DC 24 V / 1 A or max. 1 A per input/output (max. 1.5 A if only one output is used) Contact input Max. 32 detectors per line Monitored control of fire controls and alarm devices Potential-free detector contact for status or alarm messages, or for confirmation Installation Directly on mounting surface Mounting (series mounting) on TS35 U-rail Surface-mounted or recess-mounted cable entries In housing FDCH221 with cover, seal, and screws Direct mounting in control cabinet / control panel Mounting in separate FDCH221 housing Series mounting using mounting feet supplied, on profile rail TS35 Use DBZ1190-AB auxiliary terminals for shielded cables Dimensions 132 24 48 119 207 102 90 Break-out points for metal cable glands and M20 counter nuts 3

Technical data FDnet/C-NET operating voltage External power supply DC 12 33 V Input voltage DC 18 32 V (fuse provided by customer) Inputs/outputs as Collective detector line Collective line code KLK Terminal resistance Control output Contact input Terminating resistor combinations GMT Siemens/Cerberus, Synova 300, or similar 32 20 V voltage reference diode or EOL22(Ex) DC 24 V ±5 % / max. 1 A (fuse provided by customer) per output and max. 1.5 A if only one output is used 3.3 kω / 680 Ω, 2.7 kω / 560 Ω, 3.3 kω Operating temperature -25 +60 C Storage temperature -30 +65 C Air humidity Communication protocol Pluggable connection terminals Color Housing Cover FDCH221 additional housing EN 60529/IEC 60529 protection category With FDCH221 additional housing 95 % rel. FDnet/C-NET 0.2 1.5 mm² (2.5 mm² auxiliary terminal) White, ~RAL 9010 Transparent matt White, ~RAL 9010 IP30 IP65 Standards CEA GEI I-084, EN 54-17, EN 54-18 Approvals VdS LPCB DNV GL (Marine) System compatibility FDnet C-NET G206054 531m/03 59 825-13 HH FS20, AlgoRex, SIGMASYS FS720 4

Details for ordering Type Art. no. Designation Weight FDCIO223 S24218-B102-A1 Transponder incl. 2x 20 V voltage reference 0.164 kg diodes, 4 sets of terminating resistors, 2 mounting feet FDCH221 S54312-F3-A1 Housing with cover, seal, and screws 0.280 kg A5Q00004478 M20 x 1.5 metal cable gland 0.039 kg A5Q00004479 M20 metal counter nut 0.006 kg DBZ1190-AB BPZ:4942340001 1.0 2.5 mm 2 connection terminal (3-pin) 0.002 kg Spare part FDCM291 A5Q00003855 Mounting feet (25x) 0.060 kg For details, see equipment overview 008164 (Sinteso), A6V10225323 (Cerberus PRO) For system compatibility details, see the lists of compatibility 008331 (Sinteso) and A6V10229261 (Cerberus PRO) 5

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 009168_j3_en_-- FD20/FD720 manual Edition 2016-05-23 Register 5 / 5