Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Similar documents
Precise Temperature Control; Compact Footprint

NQ Series Portable Chillers

GP SERIES Packaged Chillers

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

MAC N-407 Air-Cooled Chiller

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Central Chillers TS Series

MACH N-407 Heat Pump Air-Cooled Chiller

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Aquaflair TRAC-TRAF-TRAH

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

WO P NF L M 407c Spec Submittal

LQ AQ SQ. Air-cooled and water-cooled portable chillers

WO P NF L M 407c Spec Submittal

APC Refrigeration Distribution Unit (RDU) Guide Specifications

LQ AQ SQ. Air-cooled and water-cooled portable chillers

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Trailblazer air cooled scroll chillers

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

OACS Outdoor Air-Cooled Central Chillers

Liebert CSU3000 Chiller

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

PACKAGED AIR COOLED Product Data Catalog

PDF Created with deskpdf PDF Writer - Trial ::

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

Trouble Shooting Guide FAA, 3-phase (D3631)

MAC-120HE-03 Air-Cooled Chiller

MEDICAL CHILLER SYSTEMS

Trouble Shooting Guide PWA, 3-phase (D10571)

SECTION ROTARY-SCREW WATER CHILLERS

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

Call us today! (800)

SpaceKeeper Console (SKC)

Part IV: Flow Side Components Flow Diagram

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Air-Cooled Modular Split Systems. Product Data Catalog

Water-to-Water Heat Pump Product Data Catalog R-134a Modules MR010AN, MR015AN, MR020AN, MR030AN, MR040AN, MR050AN, MR070AN, MR085AN

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Temptek Auxiliary Equipment

PYXIS U PYXIS U. rcgroupairconditioning

Energy-Saving Industrial Water Chillers

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Cutting Edge Compressor Technology

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Air-Cooled Condensing Units with Compact Screw Compressors

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

CHILLER. Operator s & Installation Manual

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

.2 Section Waste Management and Disposal.

OTC, OTM and OTI Series Options Index for PLC Control Systems:

REFRIGERATED AIR DRYERS

Outstanding Performance; Application Flexibility

Table of Contents (Hydronic)

SCROLL COMPRESSORS TYPE AIR COOLED PACKAGE CHILLERS

VariCool VAV Engineering Guide

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Operation and Installation Manual. GP Series Portable Chillers

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Air-Cooled SEMIHERMETIC

Product Chillers A P P L I C AT I O N S

Call us today! (800)

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

TRIDENT GS SERIES Central Chiller

SECTION AIR COOLED WATER CHILLERS

MCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers

Refrigerated Air Dryers

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

R- 410A Series Zero Ozone Depletion

pyxis u pyxis ua NEW rcgroupairconditioning

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Nirvana. Cycling Refrigerated Dryers

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

PRODUCT GUIDE SPECIFICATIONS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

Call us today! (800)

General Description. Operation

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

OTC, OTM and OTI Series Options

Transcription:

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers What Sets Delta T Systems Chillers Apart? Variable Speed Compressor The compressors used in all Delta T Systems chillers have a variable speed, brushless DC motor. This allows the chiller to operate anywhere between 10% and 100% of its rated capacity. When less cooling is required, the compressor will adjust to prevent over cooling or wasting energy. This results in an energy savings of 30% to 50% of initial investment. Variable Speed Fan Motors The fan motors used in Delta T Systems air-cooled chillers are also variable speed. The RPM of variable speed fan motors will vary depending on the cooling load required. The speed will adjust to match the compressor load requirements, which also leads to large energy savings. State of the Art Control Carel is the leader in HVAC and process temperature controls. They have developed a Delta T Systems specific control program that allows us to utilize the variable speed technology, along with numerous sensors, to operate the chiller at its most efficient point. These advanced controls make Delta T s chillers industry 4.0 ready, and even have optional remote connectivity. Dew Point Control Our chillers are widely used in many highly controlled environments. With dew point control, the process water temperature and ambient temperature and humidity are considered, and the water is cooled to a point that will not produce sweating. Sweating is when machines begin to have water condense on their outer surfaces. Electronic Expansion Valve The electronic expansion valve has an electronic actuator that allows the valve to have extremely small graduations. This allows the valve to meter the refrigerant to the exact amount required for the cooling load. Microchannel Condenser Coils An air-cooled Delta T Systems chiller uses a microchannel coil as its condenser. The use of small channels means there is a larger amount of surface area for heat transfer. The more area available, the more efficient the heat exchanger will be. Auto Water Makeup The auto water makeup feature ensures the chiller tank will always have the correct amount of water, even is some is lost through various processes. Every tank has a tank level sensor. When the tank level is low the controller will open the auto water makeup solenoid and allow the water source to fill the tank. Brazed Plate Evaporator The evaporator in all Delta T Systems chillers is a copper brazed plate heat exchanger. It s non-ferrous, meaning it will not rust over time.

Standard Equipment Features Microprocessor-Based PID Controller 4.3 Inch Touch Screen Display Hermetically Sealed Variable Speed Compressor Variable Speed Condenser Fan Electronic Expansion Valve Microchannel Aluminum Condenser Coils Refrigerant Suction and Discharge Pressure Transducers Refrigerant Suction and Discharge Temperature Sensors Stainless Steel Brazed Plate Evaporator Non-ferrous Chilled Water Piping Cleanable Evaporator Inlet Strainer Cleanable Condenser Inlet Air Filters Automatic Water Bypass Solenoid Digital Flow Readout % Capacity Readout Digital Tank Level Readout Digital Pump Pressure Readout To Process Pressure Readout Low Flow Indication Dirty Strainer Indication Compressor Protection Alarms High and Low Temperature Alarms Tank Level Alarms Faulty Probe Alarms Warnings and Adaptive Control Remote Alarm Output Remote Start/Stop Input 24 V Controls Phase Monitor Finger Safe Electrical Components Motor Protection Fused Transformer Protection on both Primary & Secondary Sides NEMA 12 Electrical Enclosure & Wiring in Conformance with NEC Industry 4.0 Ready Optional Features Auto Water Make-Up Alarm Horn Alarm Strobe Mounting Feet In Lieu of Casters No pump, no tank Pump, no tank Ship loose pump, no tank 50 Micron Full Flow Filter Remote Display Remote Access to Control UL 508a Stainless Steel SNMP, Modbus TCP/IP, BACnet Ethernet Communication More Upon Consultation Stainless Steel Unit

Standard Touch Screen Above is the standard 4.3 touch screen. On the home page, the unit status, pump flow, pump pressure, pump status, compressor capacity, compressor status, time and date, dewpoint, alarm notifications, set point, and outlet temperature can easily be monitored. Energy Savings Major energy savings can be seen due to the variable compressor technology, variable speed condenser fan, larger evaporator heat transfer surface, and advanced electronic expansion valve technology. A sophisticated control algorithm allows all these components to work together and result in the maximum possible savings. Warranty Delta T chillers are warranted to be free of defects in material and workmanship for one year after purchase date. Also, expendable parts are covered for 90 days.

Air Cooled Chillers Model Maximum Capacity 1 Load Condenser Air Flow (CFM) Reservoir (Gallons) Circuit Ampacity 2 Dimensions (in) Height 3 Width Depth Shipping Weight (with crate) (lbs) VSPA-001 15,570 1,217 667 12 5.5 52 20 30 440 VSPA-002 28,406 2,402 1,341 12 9.3 52 20 34 470 VSPA-003 48,672 3,603 1,937 12 11.4 52 20 34 495 VSPA-005 65,653 6,001 3,317 25 13.34 64 34 34 705 VSPA-008 88,969 9,005 4,541 25 15.5 75 34 34 760 VSPA-010 138,205 12,004 6,569 40 25.8 75 34 46 865 VSPA-015 182,712 18,003 9,726 40 32.8 85 34 46 875 VSPA-020 276,674 24,008 13,138 70 45.3 75 34 95 1,640 VSPA-025 326,125 30,020 19,452 70 45.4 75 34 92 1,755 VSPA-030 365,425 36,006 19,452 70 55.8 86 34 95 1,835 (1) Capacity based on 50 F LWT, 95 F ambient, maximum speed (2) MCA based on standard pump option. Will change with different pumps. (3) Add approximately 6 for optional alarm horn and strobe. VSPA-001-VSPA-0015 VSPA-020-VSPA-030

Water Cooled Chillers Model Maximum Capacity 1 Load Reservoir (Gallons) Circuit Ampacity 2 Dimensions 3 (in) Height 4 Width Depth Shipping Weight (with crate) (lbs) VSPW-002 28,144 2,402 12 9.0 49 20 34 470 VSPW-003 51,655 5,747 12 10.5 49 20 34 500 VSPW-005 70,630 8,100 25 11.4 51 34 34 690 VSPW-008 94,440 10,596 25 13.6 61 34 34 730 VSPW-010 146,430 15,256 40 22.5 61 34 46 800 VSPW-015 193,434 21,414 40 30.9 61 34 46 940 VSPW-020 293,179 24,018 70 39.0 72 34 95 1,640 VSPW-025 345,550 30,012 70 41.6 72 34 95 1,720 VSPW-030 386,867 36,017 70 52.0 72 34 95 1,770 (1) Capacity based on 50 F LWT, 85 F condenser inlet water, maximum speed (2) MCA based on standard pump option. Will change with different pumps. (3) Add approximately 6 for optional alarm horn and strobe. VSPW-002-VSPW-015 VSPW-020-030