RELIANCE EPS ENDOSCOPE PROCESSING SYSTEM (For Use In U.S.A. Only)

Similar documents
RELIANCE ENDOSCOPE PROCESSING SYSTEM (For Use In EUROPE Only)

RELIANCE 400 LABORATORY GLASSWARE WASHER

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR

VISION 1321/1327 CART AND UTENSIL WASHER/DISINFECTOR

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

BASIL 6700 TUNNEL CAGE WASHER

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

BASIL 9502 CAGE AND RACK WASHER

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

VHP ARD BIODECONTAMINATION SYSTEM

BASIL 6000 TUNNEL CAGE WASHER

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 37.5" NORTH AMERICA

AMSCO EVOLUTION STEAM STERILIZERS - NORTH AMERICA

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

AMSCO CENTURY MEDIUM STEAM STERILIZER 26" X 37.5" (SCIENTIFIC)

VHP M100 BIODECONTAMINATION SYSTEM

AMSCO CENTURY SMALL STERILIZERS DOMESTIC

Lower Your Costs. Expand Your Flexibility.

2015 Myco Industries, Inc Fax:

Lower Your Costs. Expand Your Flexibility.

AMSCO C SERIES SMALL STEAM STERILIZERS DOMESTIC

VS LD series vertical steam sterilizers

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 26" (SCIENTIFIC)

G 7804 Laboratory Glassware Washer. Simplified Control, Miele Quality

Introducing The Reliance 200 and 250 Glassware Washing Systems.

G 7883 CD Laboratory Glassware Washer. Analytical Cleaning, HEPA-Filtered Drying

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

A new wave in automated instrument washing. Introducing the new HYDRIM G4 series

DEKO 190 Ward washer-disinfector

CER-1 & CER-2 Installation & Testing Instructions

The Reliance 400/500 Glassware Washers

Site Requirements ADVANTAGE PLUS

AS950 REFRIGERATED SAMPLERS

9100 SERIES FLOOR LOADING CART & UTENSIL WASHER/DISINFECTOR

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

LOGIC CONTROLLED DEKO 25 EASE OF USE

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

FlaskScrubber & SteamScrubber Laboratory Glassware Washers

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

Open the Door to Increased Productivity and Cost Efficiency

AMSCO REMANUFACTURED MEDIUM STERILIZERS

G 7883 Laboratory Glassware Washer. Analytical Cleaning, Compact Design

DEKO 25 washer-disinfector

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

ENDOSCOPE DECONTAMINATION : Where are we now!

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

Version 7 1/ LXP

Customer Requirements Pre-Installation Instructions

A new wave in instrument washing and disinfection Introducing the new HYDRIM c61wd G4 series

Site Requirements. MODEL 2.0 Australia

Rhima Deko 190 Washer-disinfector for human waste containers

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

DEKO 260 Washer - Disinfector - Dryer

SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102

Version 7 1/ LX

SITE REQUIREMENTS 1 USER MANUAL INSTALLATION PACKAGE SITE REQUIREMENTS

GIRTON CABINET WASHER MODEL 794A

Freeze Dry Systems and Accessories

GIRTON TREE, TUB, AND CART WASHER MODEL 80-O

AUTOMATIC STERILIZERS

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

VWR symphony CO 2 INCUBATORS

AZTECA A LITRE STERILISER

MODEL 7000 SUCTION UNIT

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

Control Operating Costs. Gain Process Efficiency.

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories

DC200 Digital Dispenser Operating Manual

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

VHP ARD Mobile Biodecontamination System

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Accessible. Durable. Smart.

DEKO 190. Washer-disinfector for human waste containers

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

Refrigerated Incubator Model and Operating Instructions

AccuBrine automated brine maker Technical Specifications

Getinge 8666/8668 Washer Disinfectors

VHP M100 Biodecontamination Systems: Closed Loop

FLASH PAK STERILIZATION CONTAINER SYSTEM

The future is bright. And clean. And fully automated.

Application Equipment

HYDRIM. Powerful cleaning the first step to effective sterilization. Instrument Washers A HIGHER STANDARD

Standard Features. Performance/Capacities

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Model GW1020 Laboratory Glassware Washer General Specifications

LXGeR and LXGePR GLASSWASHER

Integrity 270 Integrity 270VP INTEGRITY STEAM STERILIZER INTRODUCTION

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

Transcription:

RELIANCE EPS ENDOSCOPE PROCESSING SYSTEM (For Use In U.S.A. Only) APPLICATION The Reliance Endoscope Processing System is an economical, easy-to-use high level disinfection system that can wash and high level disinfect up to two manually precleaned, immersible, reusable, heat-sensitive, semi-critical devices such as GI flexible endoscopes and related accessories. The system utilizes Reliance DG Dry Germicide, a proprietary, safe, and dry peracetic acidgenerating oxidative chemistry. The Reliance Endoscope Processing System was designed to be versatile in meeting the growing demands of the modern flexible endoscopeprocessing department, while offering the highest level of patient and staff safety. The Reliance Endoscope Processing System automated process offers the quality and the service you have come to expect and rely on from STERIS. The Reliance Endoscope Processor is intended to be used solely with Reliance DG and Verify Process Indicator strips for Reliance EPS Endoscope Processing System. Reliance DG is a proprietary, two-part, dry, single-use oxidative chemistry, designed to generate the high level disinfection solution within the Reliance Endoscope Processor. Do not substitute any other product for Reliance DG. The Verify Process Indicator strips are qualitative chemical indicators of the presence of the Reliance DG Dry Germicide active ingredient (peracetic acid). Only use Verify Process Indicator strips for qualitative detection of the presence of peracetic acid in the Reliance Endoscope Processing System. DESCRIPTION (Typical only some details may vary.) The Reliance Endoscope Processor is single door and designed as a freestanding unit (with accessory countertop and panels). A drop-down door facilitates the loading of the unit. The processor features a state-of-the-art microcomputer control system with a user-friendly operator interface. The Selections Checked Below Apply To This Equipment VOLTAGE 208 V, 60 Hz, 3-Phase 230 V, 60 Hz, 1-Phase 460 V, 60 Hz, 3-Phase CONSUMABLES Reliance DG Dry Germicide Verify Process Indicator for Reliance EPS Klenzyme Enzymatic Presoak and Cleaner CIP 200 Formulated Acid Cleaner ACCESSORIES Dual Pre-Filter and Pressure Regulator Assembly - 1 Required for Each Processor Seismic Anchorage Kit Bar Code Reader Automated Leak Test for Olympus, Pentax and Fujinon Endoscopes 1 Flow Unit 1 for Irrigation Tubes Flow Unit 2 for Olympus 145/160/165/180 Series GI Endoscopes 1 Flow Unit 3 for Pentax Water Jet P/X/00/01 Series GI Endoscopes 1 Flow Unit 4 for Pentax 70/70K/72/72K/80K/81K/ 85/85K/90i/90K Series GI Endoscopes 1 Flow Unit 5 for Cook, Medovations and CONMED Lumened Dilators (See Table 3 for Model Numbers) Flow Unit 6 for Fujinon 530 Series Colonoscopes With Water Tank Receiver Port 1 ACCESSORIES (Cont d) Leak Test Hose for Olympus 1 Leak Test Hose for Pentax 1 Leak Test Hose for Fujinon 1 ProConnect Response Center (Remote Monitoring, Priority Technical Support, Customer Care Center Access, Equipment Performance Reports) 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. Item Location(s) SD800 (10/01/10)

The processor is preprogrammed with six complete standard cycles: SINGLE for one endoscope with or without a washing phase, DOUBLE for two endoscopes with or without a washing phase, D-SHORT, and D-LONG. A standard printer records important in-cycle alarm and cycle value data. Voltage-specific electrical wiring and flexible hoses needed to install the endoscope processor are provided with the processor. A bar code reader (see ACCESSORIES) can be installed to input identification numbers for the Operator ID, Patient ID, Device ID, Procedure ID, and Physician ID. Reliance DG Dry Germicide A dry, single-use, oxidative chemistry for use only in the Reliance Endoscope Processor. When used in the Reliance EPS this chemistry is used to high level disinfect manually pre-cleaned, immersible, reusable, heat-sensitive, semi-critical devices such as GI flexible endoscopes, bronchoscopes, and related accessories. Verify Process Indicator for Reliance EPS Developed exclusively for the independent monitoring of the Reliance DG Dry Germicide used in the Reliance Endoscope Processing System. The Verify Process Indicator is used to indicate an effective dose of the peracetic acid generated during the Reliance Endoscope Processing Cycle. Klenzyme Enzymatic Presoak and Cleaner Single enzymebased detergent for surgical instruments, flexible endoscopes, and other medical apparatus used in healthcare facilities. This product is provided in a special Bag-in-a-Box container developed to ease handling and installation. CIP 200 Formulated Acid A liquid, acidic detergent system specially formulated to meet unique washing demands. This product is provided in a special Bag-in-a-Box container developed to ease handling and installation. Exterior Dimensions (W x D x H) 38 x 32-1/2 x 47-11/16" (965 x 825 x 1211 mm) Interior Chamber Dimensions (W x D x H) 24 x 19 x 23" (610 x 483 x 584 mm) Loading Height 23-15/16" (608 mm) with drop-down door open. STANDARDS The processor meets the applicable requirements of the following standards: Underwriters Laboratories (UL) Standard 61010-1. Canadian Standards Association (CSA) CAN/CSA-C22.2 No. 61010-1. Governing Directive for the affixing of the CE mark: Medical Device Directive 93/42/EEC, Annex II. ISO/DIS 15883-1: Washer-Disinfectors general requirements, definitions, and tests. ISO/DIS 15883-4: Washer-Disinfectors, using chemical disinfection for thermolabile endoscopes, requirements and tests. 2 Standards applied to demonstrate conformity to the directives: IEC-61010-1; IEC-61010-2-040; IEC-61326-1. FEATURES Rex Microcomputer This microcomputer monitors and controls the processor operations and functions. The cycle progresses automatically through the designated phases, as programmed. Front-Loading Drop-Down Door A front-loading, drop-down door is provided to facilitate loading of the unit. The door is constructed of 316 stainless steel covered with a plastic panel. The panel is strong and easy to clean. A tempered glass window allows the operator to view the chamber interior while a cycle is in progress. The panel and glass window remain relatively cool to the touch. Service Access Panel The front bottom service access panel provides easy access to the 0.2 µm bacterial-retentive filter, washer injection pumps, and other components for maintenance. Interior Fluorescent Light A 20,000-hour life expectancy interior light allows operator to view the process and load during the cycle. Bag-in-a-Box Compartment A three-shelf compartment is provided at the right of the chamber. Two of the shelves are designed to receive a separate Bag-in-a-Box container provided with a specially designed connector. The Bag-in-a-Box compartment dropdown door is made of the same easy-to-clean plastic as the chamber door panel. Washer Injection Pumps The peristaltic washer injection pumps automatically inject the correct quantity of cleaner during the appropriate cycles. The pumps are conveniently positioned behind the front service access panel for easy maintenance. Endoscope Processing Support The endoscope processing support is designed to minimize the number of connections required to flow the endoscope channels. The endoscope processing support can process one or two endoscopes and their related accessories. The endoscope processing support includes two control handle boots, labeled "A" and "B", for processing compatible flexible endoscopes. Additionally, each control handle boot can be adapted to process endoscopes that have special processing requirements (e.g., small diameters and no light guide cables). A dedicated process indicator clip on control handle boot A is designed to firmly hold the Verify Process Indicator in place during the cycle. The large mesh basket on the upper level of the endoscope processing support can hold up to two light guide cables and large compatible accessories. When required, fluid flow units can be connected to the two fluid flow ports in the large mesh basket. Bite blocks can be placed on the two accessory pegs.

On the lid of the Chemical Delivery System are two templates for measuring insertion tube diameters. The small accessories basket and cover is stored under the large mesh basket and is designed to hold small compatible accessories such as air/water valves. The valve irrigators have been designed to hold suction valves during the processing cycle. Valves are held open inside the holder to ensure solution contacts inside surfaces. Chamber The high-quality, stainless-steel chamber is insulated to reduce heat loss and noise level. Four manifold connectors are provided at the back of the chamber: one is the hot water inlet to the Chemical Delivery System, two are connectors for the pressure sensors, and one is for the endoscope processing support. The endoscope processing support is automatically connected to these manifold connectors when positioned correctly in the processor chamber. A removable debris screen at the bottom of the chamber prevents large debris from entering the piping system and pump. The screen is provided with a handle and is easily removed for cleaning. 0.2 µm Bacterial-Retentive Filter All the water supplied to the processor is filtered through a 0.2 µm bacterial-retentive filter which is conveniently positioned behind the service access panel, below the chamber door, for easy maintenance. To ensure parameters affecting filtration efficiency remain within specifications, a pressure hold integrity test is performed during each cycle. Manifolded Air Purge System This system circulates HEPA-filtered air through the endoscope processing support and inside the endoscope channels to help remove residual water. Room temperature air is used during the purge for safe processing. Non-Vented System Air charged with humidity is evacuated out the chamber through the condenser and returned to the room. Remote Printer A printer is included with the Reliance Endoscope Processor. The printer allows the operator to print process time, date, and unit malfunction data. Specific information is printed from the Operator mode (cycle parameters, cycle in process parameters, alarms) and Service mode (unit configuration values, unit setup, etc.). The printer can be installed at a convenient location up to 10 feet away from the processor. Container Detection The Reliance Endoscope Processing System will provide the user with an indication that a new Reliance DG container has been used for each cycle. Components of the in-use Reliance DG solution are monitored during the disinfection phase and the control will abort any cycle where predetermined disinfectant component level is not detected. Countertop The countertop is made of a laminated wood covered with an easy-to-clean solid plastic surface. A countertop is recommended for a free standing processor. Air Compressor An air compressor is available to provide facilities that do not have a 50 psi air supply with the means to operate the required 0.2 µm bacterial-retentive filter integrity test. Air compressor is supplied on preferred configurations but is a base model addition on other configurations. CYCLE DESCRIPTION IMPORTANT: Items to be high level disinfected must be manually pre-cleaned according to manufacturer recommendations before being placed in the endoscope processing support. Processing Cycles There are four processing cycle options to choose from: SINGLE Endoscope processing cycle with washing phase, used to process one endoscope through washing and high level disinfection (HLD) phases. Endoscope is placed in control handle boot "A." SINGLE Endoscope processing cycle without washing phase, used to process one endoscope through a high level disinfection phase only. Endoscope is placed in control handle boot "A." DOUBLE Endoscope Processing cycle with washing phase, used to process two endoscopes through washing and high level disinfection phases. One endoscope is placed in control handle boot "A" and one in control handle boot "B." DOUBLE Endoscope Processing cycle without washing phase, used to process two endoscopes through a high level disinfection phase only. One endoscope is placed in control handle boot "A" and one in control handle boot "B." Processing Cycle Description The total default cycle time with a washing phase is approximately 42 minutes. The total cycle time without a washing phase is approximately 30 minutes. Cycle time depends on the washing cycle settings entered in Supervisor mode. Temperature, pressure, and quality of the building water supply can also influence cycle time. NOTE: See Table 6 for more information. The first phase of the processing cycle is an optional, programmable washing phase. This phase consists of a wash with Klenzyme Enzyme Presoak and Cleaner, followed by a rinse. The washing phase can be programmed ON or OFF. In the ON mode, the user can choose either one or two washing phases per processing cycle. Additionally the wash segment duration can be adjusted to be between 5 and 10 minutes. The Reliance Endoscope Processing System washing phase does not replace manual pre-cleaning by the user. 3

The second phase of the processing cycle is a required high level disinfection phase and cannot be adjusted by the user. In this phase the single use container Reliance DG chemistry is dissolved with water at 122 F (50 C) and circulated throughout the processor and through the device lumens. During the first four minutes of this phase, peracetic acid is generated from the dry components creating the germicidal high level disinfection solution. This solution generation is followed by a six-minute high level disinfection phase at 122 F (50 C). The third phase of the processing cycle is a required rinse phase and cannot be adjusted by the user. The Reliance Endoscope Processor removes the high level disinfection solution using two rinses. The processor filters the rinse water (as well as all of the water used throughout the cycle) through a 0.2 µm bacterial-retentive filter. The processor also incorporates an automatic internal integrity check of the filter at the end of each processing cycle. If the integrity check fails, the user is alerted by an alarm and the cycle printout indicates a fault code for this filter integrity failure. The fourth and last phase of the processing cycle is an air purge phase using HEPA-filtered air. The air purge helps to remove excess rinse water from the processed devices. The final air purge is preset to run for four minutes; additional air purge time may be selected by the operator for up to 30 minutes. If the devices are not removed from the processor at the end of the cycle, the air purge phase will continue for up to a maximum of 60 minutes. Decontamination Cycles The processor also features two decontamination cycles intended to prevent biofilm formation in the chamber and on the endoscope processor support. The first, called D-SHORT, consists of hot water at 180 F (82.2 C) circulating through the processor for 13 minutes, followed by a 10-minute hot air purge at 240 F (115.6 C). This cycle must be run every 54 hours. If a D-SHORT cycle is not completed within this time interval, the processor is locked out from use until a D-LONG cycle (see below) is run. D-SHORT is intended to prevent biofilm formation and contamination. The second decontamination cycle, called D-LONG, consists of a cycle in which CIP 200 Acid-Based Process and Research Cleaner is added to hot water at 180 F (82.2 C). The washing solution is then circulated through the processor for 20 minutes; this is followed by three rinses to remove the solution from the processor and a 10-minute hot air purge at 240 F (115.6 C). D-LONG is to be used on those occasions when the D-SHORT cycle has not been run within the past 54 hours. D-LONG is intended to prevent biofilm formation and contamination. TEST Cycle A TEST cycle program is available for service and maintenance. CONTROL SYSTEM Design Features Operator Interface Control Panel, consists of a display screen, a touch pad, ON/OFF and UNLOCK toggle switches. Display Screen The control display window features a 2- line x 16 characters, easy-to-read vacuum fluorescent display. Display shows cycle status, remaining time, alarms, and instructional messages. Display also indicates abnormal conditions that may occur during a cycle. Touch Pads Membrane-type touch pads allow the operator to select, start, stop, or abort cycles. An audible signal is heard to acknowledge that a pushbutton has been pressed. Audible Signals The audible alarm signal warns the operator that an action must be taken or when a cycle is completed. Cycle/Day Count Recall System A Cycle/Day Count Recall System reminds the operator when a complete preventive maintenance check is required. Cycle Configuration The control system offers three different modes. Operator mode allows an operator to only Start/Stop/Resume/Abort cycles. Service mode allows a service technician to perform preventive maintenance and testing. The Service mode also facilitates troubleshooting. Supervisor mode allows an authorized operator to modify the time value for the Wash 1 and Air Purge phases, set date and time, program bar code IDs, and select the operating language and the "repeat washing" feature. In addition to the adjustment of cycle values, the following operating parameters can also be changed in Supervisor mode: Time Display and Printout Units Standard AM/PM or 24 hour military time (MIL). Temperature Display Fahrenheit ( F) or Celsius ( C). Temperature is set, displayed, controlled, and printed to the nearest 0.1 degree. Recalibration is not required when changing temperature units from F to C and vice versa. Pressures may be programmed in psi or kpa. Recalibration is not required when changing unit pressure from psi to kpa or vice versa. TECHNICAL DATA Control System Control system consists of microcomputer control boards and peripheral function circuit boards, located within the control board housing. Electronic Temperature Control Resistive Temperature Device (RTD) sensors are used instead of conventional thermostats, to provide accurate control inputs and readouts throughout all phases of the cycle. Electronic Pressure Monitoring Two pressure transmitter sensors are used to provide control measurements and readouts of the pressure developed within both control handle boots during the washing (optional) and HLD phases. A third pressure transmitter sensor is used to provide accurate pressure measurements during Filter Integrity Pressure Hold Test. 4

Internal Battery An internal battery backs up all cycle memory for up to 10 years. If a power failure occurs during a cycle, the battery back-up system ensures that cycle memory will be retained and proper cycle completion will occur once power is restored. When power is lost, the cycle is held in phase until power is restored. Once power returns, the event is recorded on the printout and the cycle automatically resumes or is aborted, depending on which phase the cycle was in at the time of power loss. SAFETY FEATURES Safety Door Switch A microswitch prevents a cycle from starting if door is not fully closed. Safety Stop Pressing the STOP touch pad once automatically pauses operation of the unit and pressing the STOP touch pad a second time aborts the cycle. Unlock Toggle Switch Processor is provided with an UNLOCK toggle switch that must be pressed to open the door. Labeling The Reliance Endoscope Processing System is labeled with safety precaution labels and equipped with wall charts to warn and inform operator and service technicians of precautions to take and proper use of the processor. Process Monitoring The control system monitors pressures within the control handle boots and warns the operator if pressures drop below the minimum requirement or exceed the maximum requirement for safe and effective processing of the devices. Water and air temperatures within the processor chamber are monitored for safe processing. The rinse water quality is automatically monitored every cycle by a filter integrity pressure hold test. A vacuum switch in the cleaning solution injection line signals the control when there are insufficient reserves. A level float, consisting of a magnetic float switch, controls the sump water level. Verify Process Indicator strips are designed to confirm an effective dose of peracetic acid during the high level disinfection process. CONSTRUCTION Chamber Chamber is constructed of 20 gauge, 316L stainless steel (#4 finish), and is seam welded. Chamber inhibits corrosive action of chemicals and is easy to wash, with no enameled surfaces to chip or crack. Sump capacity is four gallons (15 L). Stainless steel 304 heating coils are included. Insulated Construction Insulated construction of chamber exterior reduces heat loss and noise level for both undercounter and freestanding units. 5 Piping and Recirculation System All components of the recirculation system, including sump, screen, rotary spray arms, pump, Chemical Delivery System, water filter housing, piping, and endoscope processing support, are constructed of 316L stainless steel, silicone, polypropylene, and/or hydrophilic polyvinylidene fluoride (PVDF). All materials are compatible with Reliance DG, Klenzyme Enzymatic Presoak and Cleaner, and CIP 200 Acid- Based Process and Research Cleaner. Stainless-Steel Pump All phases are under pressure utilizing a 1.5 HP stainless-steel pump with a 66 U.S. gal/min at 52 ft. (249.8 L/min at 16 m) capacity. Pump impeller, shaft, and casing (all stainless steel construction) are fitted with a mechanical seal. Pump impeller is mounted directly on motor shaft. Pump motor is thermally protected and is equipped with a totally enclosed frame (TEFC), magnetic starter, and sealed bearings (requiring no periodic lubrication). Removable Debris Screen The debris screen, constructed of 304L stainless steel (#4 finish), is located at the bottom of the sump and prevents large debris from entering the piping system and pump. Screen can be easily removed for cleaning. MOUNTING ARRANGEMENT The Reliance EPS Processor is designed as a fully enclosed unit for recessed or freestanding installation. Casters and flexible utility hoses are provided to allow unit to be moved in and out of mounting location for maintenance purposes. Processor is inter-piped and inter-wired, requiring only one connection for each service and utility hook-up. ACCESSORIES NOTE: See Table 1 for more information. Seismic Anchorage Kit A seismic anchorage kit is available and meets seismic building code requirements for high risk seismic zones. Report is supplied with the seismic kit. Bar Code Reader Allows input and traceability of important data from printed bar codes such as Operator ID, Patient ID, Device ID, Procedure ID, and Physician ID. Automated Leak Test This feature, when activated, will detect leaks in flexible Olympus, Pentax and Fujinon endoscopes prior to processing. 1 The endoscopes will be pressurized within the manufacturer s specified ranges and leaks as low as 0.22 psig (15 mbar) will be detected. Minimal pressure is maintained and monitored throughout the processing cycle. 1. Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc.

Dual Pre-Filter and Pressure Regulator Assembly (Required) Assures hot water is supplied at optimal pressure and quality to the processor. Assembly includes: one multi-layer depth media filter cartridge, one dual layer absolute membrane filter cartridge, one pressure regulator to reduce incoming water pressure to 345 kpa (50 psi), and one spanner wrench to easily screw and unscrew filter bowls for maintenance. ProConnect Response Center Minimize response time and unscheduled downtime on your equipment. Secure, internet-based, 24/7 remote monitoring enables alerts to STERIS when there is an equipment alarm. Also included are priority technical support, online parts ordering, equipment performance dashboards, and scheduling service at eservice.steris.com. Flow Units (1, 2, 3, 4, 5 and 6) NOTE: See Table 2 for more information. Flow Unit 1 is a Reliance Endoscope Processor accessory that must be used for processing Olympus, Pentax, and Fujinon endoscope 1 irrigation tubes. Flow Unit 2 is a Reliance Endoscope Processor accessory that is required for processing Olympus 145/160/165/180 Series GI Endoscopes 1 with an auxiliary water channel. This independent channel flows from the light guide control end connector to the distal tip without an access port on the control handle. Flow Unit 3 is a Reliance Endoscope Processor accessory that is required for processing Pentax P/X/00/01 Series GI Endoscopes 1 fitted with a non-removable, mechanicallyactuated valve at the control handle's auxiliary water channel port. Flow Unit 4 is a Reliance Edoscope Processor accessory that is required for processing Pentax 70/70K/72/72K/80K/81K/85/ 85K/90i/90K Series GI Endoscopes 1 with a water jet channel. The independent channel flows from the light guide control connector to the distal tip. Flow Unit 5 is a Reliance Endoscope Processor accessory that must be used when processing Cook, Medovations or CONMED esophageal dilators with a lumen (internal channel). Non-lumened dilators from Medovations, Pilling and Rusch do not require a Flow Unit to process. Flow Unit 6 is a Reliance Endoscope Processor accessory that is required for processing Fujinon 530 Series Colonoscopes 1 with Water Tank Receiver Port. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. PREVENTIVE MAINTENANCE A global network of skilled service specialists can help provide periodic inspections and adjustments to help ensure low cost peak performance. STERIS representatives can provide information regarding annual maintenance programs. NOTES NOTE: See Table 4 and Table 5 for more information. 1. Where required by local codes, installation of a backflow preventer, such as Wilkins 975XL 1/2" NPT or equivalent (not provided by STERIS) is recommended for hot and cold water inlets. 2. Pipe sizes shown indicate terminal outlets only. Building service lines (not provided by STERIS) must supply the specified pressures and flow rates. 3. Disconnect switches (with OFF position lockout only; not provided by STERIS) should be installed in electric supply lines near the equipment. 4. Clearances shown are minimal for installing and servicing the equipment. Refer to equipment drawing for specific details. 5. Customer must ensure processor stands on noncombustible, nonslip floor. The base language of this document is ENGLISH. Any translations must be made from the base language document. 6

Table 1. Accessories - Processor DESCRIPTION OVERALL DIMENSIONS W x L x H Inches (mm) SHIPPING WEIGHT lb (kg) APPLICATION Seismic Anchorage Kit (MB00-0016) 8 x 6 x 3 (203 x 152 x 76) 1 (0.5) A seismic anchorage kit is available for high-risk seismic zones. Bar Code Reader (MB00-0048) 11 x 14 x 4 (279 x 356 x 102) 2 (0.9) Bar code reader to read data barcodes (includes instructions). (Required) Dual Pre-Filter and Pressure Regulator Assembly (MB00-0067) 11 x 16 x 21 (279 x 406 x 533) 28 (13) Reduce the particulate and microbial load on the final 0.2 µm filter (includes instructions). Installation Kits 12 x 48 x 4 (305 x 1219 x 102) 28 (13) Main Electric Supply Cord, Flexible Hose and Pressure Regulator for Cold Water Inlet, Service Handles. Automated Leak Test Assembly Kit (MB00-0029) N/A N/A Automated leak test of Olympus, Pentax, and Fujinon Endoscopes a. Kit includes hardware and instructions to install and perform leak testing automatically. a. Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. Table 2. Accessories - Leak Test Hoses DESCRIPTION ILLUSTRATION APPLICATION Leak Test Hose Assembly Kit for Pentax Endoscopes (MB00-0041) To connect to Leak Test Port of Pentax Endoscopes 1. Leak Test Hose Assembly Kit for Olympus Endoscopes (MB00-0042) To connect to Leak Test Port of Olympus Endoscopes 1. Leak Test Hose Assembly Kit for Fujinon Endoscopes (MB00-0043) To connect to Leak Test Port of Fujinon Endoscopes 1. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. 7

Table 3. Accessories - Flow Units DESCRIPTION ILLUSTRATION APPLICATION Flow Unit 1 (EPSC001INT) To process Olympus, Pentax, and Fujinon endoscope 1 irrigation tubes. Flow Unit 2 (EPSC002INT) To process Olympus 145/160/165/180 Series GI Endoscopes 1 with an auxiliary water channel. Flow Unit 3 (EPSC003INT) To process Pentax Water Jet P/X/00/01 Series GI Endoscopes 1 fitted with an auxiliary water channel port located on the control handle. Flow Unit 4 (EPSC004INT) To process Pentax 70/70K/72/72K/80K/81K/85/ 85K/90i/90K Series GI Endoscopes 1 with a water jet channel. Flow Unit 5 (EPSC005INT) To process Cook (SGD-5/6/7/8/9/10/11/12/12.8/14/ 15/16/17/18/19/20-70 and SGD-5/6/7/8/9/10/11/12/ 12.8/14/15/16/17/18/19/20-100) Medovations 1214-15/18/21/24/27/30/33/36/39/42/45/48/51/54/ 57/60) and CONMED (000270-000275, 000277-000281 and 000288-000291) Lumened Dilators. Flow Unit 6 (EPSC006INT) To process Fujinon 530 Series Colonoscopes 1 with Water Tank Receiver Port. 1 Registered trademarks of Olympus Optical Co., Ltd., Pentax Imaging Company, and Fujinon Inc. 8

Table 4. Engineering Data SHIPPING WEIGHT lb (kg) OPERATING WEIGHT lb (kg) A-WEIGHTED EQUIVALENT SURFACE SOUND db HEAT LOSS BTU/hr (W/hr) COLD WATER U.S. gal (L) PER CYCLE HOT WATER CONSUMPTION PER CYCLE1 U.S. gal. (L) 730 (331) 660 (300) 65.4 1 Single or Double Cycle without optional cleaning phase. 2420 (709) 0.76 (2.9) 12.28 (46.4) Table 5. Utility Requirements ITEM HOT WATER (HW) COLD WATER (CW) AIR* DRAIN Size 5/8" Barbed M 1/2" NPT M (BSPT M) 1/4" OD 1-1/2" ID (30 mm) Dynamic Pressure Building Water Supply Temperature Maximum Flow Rate Quality Processor Electricity Printer Electricity 40 to 50 psig (2.76 to 3.45 bar) 110 F (43 C) to 118 F (48 C) 2.3 U.S. gal/min (8.7 L/min) 40 to 50 psig (2.76 to 3.45 bar) 70 F (21 C) maximum 1.9 to 4.2 U.S. gal/min (7.19 to 15.9 L/min) 50 to 125 psig static (3.45 to 8.62 bar) N/A 0.2 cfm N/A N/A 4.0 U.S. gal/min (15.0 L/min) Potable Water, 300 ppm max CaCo 3 300 ppm max CaCo 3 See Note Below N/A 208 V, 60 Hz, 3-Phase, 30 Amp 230 V, 60 Hz, 1-Phase, 40 Amp 460 V, 60 Hz, 3-Phase, 15 Amp 120 V, 60 Hz, 1 Amp CUSTOMER IS RESPONSIBLE FOR COMPLIANCE WITH APPLICABLE LOCAL AND NATIONAL CODES AND REGULATIONS. NOTE: Maximum particulate size: 5 microns. Maximum dew point: 37-45 F(3-7 C). Maximum oil concentration: 5 mg/m 3. *Requirement without optional Air Compressor installed. Telecommunications requirements for ProConnect Response Center An active wired or wireless TCP/IP network, 10/100BaseT Ethernet connection at each piece of connected equipment, Internet access and an IP address on the facility network. 5 GB of available hard drive space to run the service agent. Can be installed on:» Dedicated PC running Windows XP with 2.8GHz processor, 512MB of RAM» Virtual Machine» Server Local STERIS login at the PC, with a username of STERIS and the password should be ProConnect (STERIS Customer Number). Ethernet cable to connect each piece of STERIS equipment and the dedicated PC to the facility network. 110V power receptacle at each piece of connected equipment. 9

Table 6. Cycle Description Chart SINGLE OR DOUBLE ENDOSCOPE PROCESSING CYCLE WITH WASHING OPTIONAL PHASES REPEAT WASHING Phase WASH RINSE WASH RINSE HLD RINSE 1 RINSE 2 AIR PURGE Water type HTW HTW HTW HTW HTW HTW HTW Set point temperature C ( F) Heated to 48.0 (118.4) Time 05:00 Adjustable: [05:00-10:00] Heated to 48.0 (118.4) 00:40 05:00 Adjustable: [05:00-10:00] Heated to 50.0 (122.0) 00:40 10:00 Generation: 04:00 * Disinfection: 06:00 *Generation starts when water temperature reaches 50.0 (122.0) 00:40 00:40 04:00 Adjustable: [04:00-30:00] Time is extended to 60:00 if treatment is not ended manually after set time. Chemical additive Klenzyme Klenzyme Reliance dry chemistry Concentration ml/l (oz/gal) 2 (1/4) 2 (1/4) D-SHORT Decontamination cycle only, do not run with endoscopes Phase WASH AIR PURGE Water type Set point temperature C ( F) HTW Heated to 82.2 (180.0) Heated to 115.6 (240.0) Time 13:00 20:00 Venting: 10:00 Cooling: 10:00 Chemical additive Concentration ml/l (oz/gal) D-LONG Decontamination cycle only, do not run with endoscopes Phase WASH RINSE 1 RINSE 2 RINSE 3 AIR PURGE Water type HTW HTW HTW HTW Set point temperature C ( F) Heated to 82.2 (180.0) Time 20:00 Chemical is injected 10 minutes after temperature is reached. Heated to 115.6 (240.0) 00:30 00:30 00:30 14:00 Venting: 10:00 Cooling: 04:00 Chemical additive Concentration ml/l (oz/gal) CIP200 16 (2) HTW Legend 0.2 µm filtered hot tap water Not applicable HLD = High Level Disinfection Phase in the Reliance Endoscope Processor. NOTE: Times shown in Cycle Chart do not include fill and drain times. These times may vary depending upon facility supplies. 10

Refer to the Following Equipment Drawing for Installation Details Equipment Drawing Part Number 920-011-656EN Equipment Drawing Title Reliance Endoscope Processing System Dimensions are inches [mm] Dimensions are typical - drawing is not to scale. FRONT VIEW [608] COUNTERTOP Not For Installation SIDE VIEW 11

For Further Information, contact: STERIS Corporation 5960 Heisley Road Mentor, OH 44060-1834 USA 440-354-2600 800-548-4873 www.steris.com SD800 2010, STERIS Corporation. All rights reserved. (10/01/10) This document is intended for the exclusive use of STERIS Customers, including architects or designers. Reproduction in whole or in part by any party other than a Customer is prohibited.