M60 LED Recessed Wet Location

Similar documents
M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

M100 LED Direct/Indirect

M100 My White LED Direct Tunable White

M36 My White LED Direct

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

RECESSED - WITH StepLens OPTION

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Recessed LED Wall/Slot SAE 202

Grüv Flare Regressed. Recessed Linear LED

RECESSED T-Bar & Drywall

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Grüv Flare Regressed. Recessed Linear LED

BAS SFP22 Edge-lit LED Panel

RECESSED Spec Guide. up to 111 lm/w performance

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

Max 4 Flush Lens RECESSED

Dimensions (111mm) (111mm) 3 (76mm)

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

SURFACE Spec Guide. up to 105 lm/w performance

LUX PENDANT DIRECT/INDIRECT

3.75 Gyro Shift Multiples Single Head

lumenalpha downlight Specification Sheet

Fino. Asymmetric Wall Mount Indirect LED

Claude Indirect Wall WALL

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

FULL BLEED APPLICATION SHOT RENDERING

LHBXD LED Linear High Bay

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Etch 2' x 2' Recessed LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evoke Square Downlight

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evoke Square Downlight

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

Alliance 4 - ALI4 LED 4 Linear High Bay

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Square Downlight

Luminaire Type: Catalog Number: Slot Trim (SLT) MYO Configurable 1, 2 & 3-Head Recessed Multiple Series

Hornet HP. Round Glass Downlight

BeveLED Cylinder LBRP6 Surface

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

ArcLine Recessed LED luminaire

New Linear Series DISCONTINUED

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Truss Surface SURFACE

SOLID STATE ILLUMINATED RAIL

Evoke 2.9" HP. 2.9" Square Downlight

Essenza. Round Downlights

Linea 1.5. Linear Direct Wall Wash LED

Classix 6" 6" Round Lens Wall Wash

Catalog # Project. Comments. Prepared by. 23-3/4" [603mm] LAMP CONFIGURATIONS. 3-1/4" [83mm] X=2-7/16" [62mm] Y=2-1/2" [64mm] CEILING COMPATIBILITY

LED FLAT PANEL EDGE LIT MLFP SERIES G2

Essenza. Square Downlights

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Performance Chart Electrical Data

l i g h t A B S O R B H

Downlight Adjustable Wall Wash Lens Round Square 4", 6", 8" Dimming Retroficient Controls LED downlighting size and shape, lumen output

Performance Chart Electrical Data

Performance Chart Electrical Data

NOVA CEILING WALL GRAZER WITH REMOTE POWER

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Performance Chart Electrical Data

SYSTEM. field cuttable. lipleds 8200 Series

Project Name. Date. Cat. Number. Type

RLN Recessed LED luminaire

VESICA LINEAR SUSPENDED VES L

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Evoke Round Downlight

Essentials Series 4.0

PROJECT DATE FLANGE FINISH

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Ivalo Lumaris LED Linear Lighting

CERRA 10 LED Design2Ship

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

Classix 6" 6" Round Lens Downlight

Project Name. Date. Cat. Number. Type

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS

Classix 6" 6" Round Lens Wall Wash

ERIA SQUARE. ERIA with Square Open Trim JMA ST ERIA HOUSING JMA SH COLOR OPTIONS. Available in Satin White or Satin Black finishes

Transcription:

Date: Customer: Project: Type: Qty: M60 Order Code: - - - - - - - - - - Series L60W Multi-Mount Form L6WR Continuous Flange (Flanged Endcaps) L6WR Continuous Flange (Flangeless Endcaps) Light Engine B,, 789 lm/.w B0,, 7 lm/9.8w B 68 lm/8.6w B0, 6 lm/7.w B, 8 lm/6.w B0, 6 lm/.7w Values calculated from a fixture @000K using LW Shielding and DIM driver. For additional information please see page. Available starting at and up. Not available with Lutron. CCT 7 0 700K 000K 00K 0 000K Shielding LW LED Optimized white lens MI Clear with Microprism NB LMO Symmetric with Satine A LMO Asymmetric 0 Wall Washer with Satine A LMO Asymmetric Wall Grazer with Satine BW LMO Batwing with Satine See page for details. Mounting L60W or SF Spackle Flange (/ Drywall) SF SF DC Spackle Flange Spackle Flange Decoustic (/8 Drywall) (After Drywall) Ceiling (up to thick) Mounting L6WR or L6WR RC TS Rotating /-0 Stud Crossbar (Ceilings / to thick ) VTS Vertical Threaded Stud PM Perimeter Mount L6WR only 6 Consult factory for lengths under Nominal Length 0* ft. 0 ft. 0 ft. 0 ft. 0 ft. 06 6 ft. 07 7 ft. 08 8 ft. 09 9 ft. 0 0 ft. ft. * fixture only available with B light engine. Individual fixtures and Runs are supplied in nominal lengths to ensure full, even, illumination. See pages thru 6 for additional details. ft. XX Runs (over ) round up to the nearest foot and replace the xx with the # (i.e. = nominal) Finish WH White BK Black BL Semi-Matte Black SV Silver SP Specify Premium Color Custom colors are available, Please consult factory Voltage 0 0 Volt 77 77 Volt 7 UNV 0 thru 77 7V 0/60hz capable (consult factory) Driver DIM 7 DM 7,8 DML 7,8 DMD 7,8 0-0V (Linear) 7,8, 9, 0 DC Lutron -Wire eldoled SOLOdrive 0-0V (Linear) DC 7,8,0 Lutron -Wire eldoled SOLOdrive 0-0V (Logarithmic) eldoled DALI (Logarithmic) 7,8, 0 DC DCE Lutron -Series Lutron Eco-System (consult factory) 7 See page 7 for full details 8 Not available for length 9 0V only 0 Not available with B or B0 Options FS In-line Fuse SS Separate Switching CCEA CCEA approved TR Tamper Resistant / End Cap See page 8 for full details and restrictions Not available with EMN option See page 8 for details Emergency Options EC Emergency Circuit Wiring EMR EMN Remote Micro Integral Inverter EM battery pack (Consult Factory) (Consult Factory) See page 8 for full details and restrictions YEAR LED WARRANTY ARRA Compliant Page of 0

/8 (60mm) /8 (60mm) 9 /6 (9mm) 9 /6 (9mm) 9 /6 (9mm) 9 /6 (9mm) / / / / (6mm) (6mm) (6mm) (6mm) /8 (60mm) /8 (60mm) /6 (8mm) /6 (8mm) Direct & Recessed Depicted Direct & Recessed Snap-in Gasket Depicted Recessed Depicted Recessed Snap-in Gasket Depicted Construction: Housing - Continuous, low copper 606-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to ) or Runs. Flange - 9/6 (mm) wide flange runs full lengths of both sides and is part of the main extruded body. Specify continuous flange (L6WR) or flush (L6WR) end cap. L6WR does not work in T-Bar ceiling. Geartray - Low copper 606-T6 extruded aluminum profile. Shielding - Extruded, impact resistant acrylic snap in lens: - LED optimized white lens (LW) - Clear lens with microprism (MI) LMO refers to the Selux proprietary LED optical system - Light modulation optics. These lenses are offered in M60 behind a Satine for even illumination and comfortable lit appearance. - LMO symmetric lens (NB) - LMO Asymmetric wall grazer (A) - LMO Asymmetric 0 wall washer (A) - LMO Batwing (BW) * Please note that the snap-in cover is a frosted acrylic, designed to match the visual appearance of the LW. Gasketing - Frosted acrylic snap-in cover plate at ends and each joint, combined with transmissive gasket ensures ease of installation and a clean, illuminated surface. *Housings other than White may have additional shadowing at the cover plates. Tamper Resistant - Aluminum plates with gasket and tamper-resistant hardware replaces the snap-in cover at ends and joints. Painted housing color by default. Mounting(s) - Spackle in (drywall), Slot grid, Decoustic, T-bar grid, Perimeter, Rotating Crossbar and Threaded Stud Mountings (RC, TS, or VTS mountings). See pages thru 6 for details.ceiling or vertical wall recessed mounting only. Not suitable for floor or horizontal wall recessed installation. Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs are available in approximately / increments starting at the nominal fixture length. ** Individual luminaires are not joinable in the field. Exact Luminaire lengths - Individual luminaires and Runs are available in exact lengths to meet your project needs. Please consult factory with you requirements. ** luminance may soften at the very ends of the straight sections for exact length luminaires. L60W Joiner(s) - Runs are supplied in multiple housings that are joined together in the field using the supplied L60W Joiner System. This allows ease of installation and ensures a uniform appearance (see page 8 for detail). Weight:. lb.. Electrical/Performance: LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at,000 hours and 9% at 60,000 hours @ ºC per TM- reports. Reported L70 greater than 60,000 hours Delivered Lumens - Due to LED manufacturer s tolerances the listed output has a ±% tolerance. For outputs based on different shielding or CCT please see photometry section at the end. CCT - Available in 700K, 000K, 00K and 000K, tolerance within a -step MacAdam ellipse. CRI - Min. 90. All Drivers - High efficiency, constant current, soft start, Electronic Class with a PFC>0.90. For more detailed information on the available drivers please see page 7. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of C (9 F) for all drivers. Luminaires are suitable for minimum ambient temperatures of: -0ºC (-0ºF) for DIM, DM, DML, and DMD drivers. 0ºC (ºF) for DC, DC, and DCE drivers. Luminaire Finish: Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. Standard interior colors are White (WH), Black (BK), Semi-Matte Black (BL), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Housing colors other than White may have additional shadowing at the cover plates. Warranty: Year Limited LED Luminaire Warranty - Selux offers a Year Limited Warranty to the original purchaser that the M60 series LED luminaire shall be free from defects in material and workmanship for up to five () years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see Selux Terms and Condition of Sale. Certifications and Compliance: NRTL - For Dry, Damp, and Wet location (I.E. culus; ccsaus) Suitable for ceiling or wall recessed installation only. Not suitable for floor or horizontal wall recessed installation. ARRA Compliant RoHS Compliant IC-Rated * *EMN option is Non-IC-rated Page of 0

/ Spackle Flange Mounting (SF) / Spackle Flange Mounting (SF) "A" "C" s must be installed before drywall. Side 6 Bottom Installation brackets 7 8 /" (Ref.) /8 Spackle Flange Mounting (SF) /8 Spackle Flange Mounting (SF) Side "D" Feed "A" "C" s must be installed before drywall. 6 Bottom Installation brackets 7 8 After Sheetrock Flange Mounting (SF) After Sheetrock Flange Mounting (SF) "A" / (Ref.) 0 Side Ø7/8 Feed hole located in the end of the electrical connection box. Blocking (by others) Blocking (by others) 9 Bottom Installation brackets 7 8 9/6 (Ref.) Spackle Flange Mounting (SF, SF & SF) - Dimensions Nominal Length A O.A.L. w/o Flange B End Suspensions * C (Ref.) Mid. Suspension D Feed Location Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 0 ( ft.) ' - /6" 0' - /8" 0' - 9 /8" 0' - /8" 0 0 ( ft.) ' - 7/6" 9 0' - /8" ' - 8 /6" 0' - /8" 0 0 ( ft.) ' - /6" 9 0' - 6 /8" 6 ' - /8" 6 0' - /8" 0 ( ft.) ' - 7/6" 0 0' - 6 /8" 6 ' - /6" 89 0' - /8" 0 ( ft.) ' - 7/6" 0 0' - 6 /8" 6 ' - /6" 99 0' - /8" 06 (6 ft.) ' - 7/6" 8 0' - 6 /8" 6 ' - /6" 0 0' - /8" 07 (7 ft.) 6' - 7/6" 9 0' - 6 /8" 6 ' - /6" 808 0' - /8" 08 (8 ft.) 7' - 7/6" 0' - 6 /8" 6 6' - /6" 0' - /8" 09 (9 ft.) 8' - 7/6" 79 0' - 6 /8" 6 7' - /6" 8 0' - /8" 0 (0 ft.) 9' - 7/6" 0 0' - 6 /8" 6 8' - /6" 7 0' - /8" ( ft.) 0' - 7/6" 8 0' - 6 /8" 6 9' - /6" 07 0' - /8" ( ft.) ' - 7/6" 6 0' - 6 /8" 6 0' - /6" 0' - /8" *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance.. /-0 Threaded rod to structure (supplied and installed by others).. /-0 Coupler hardware (supplied and installed by others).. /-0 Stud (by Selux).. Ø/6 [Ø7mm] mounting hole.. Drywall/Sheetrock screw (Ref.) 6. Drywall/Sheetrock (Ref.) 7. /6 Plaster skimcoat (Ref.) 8. Drywall/Sheetrock tape (Ref.) 9. Blocking to secure fixture (by others) 0. Electrical connection box, removable side cover for electrical connection pre-installation, once installed the wiring is accessible from below the ceiling through the luminaire.. Luminaires ship with the brackets pre-installed. - The brackets cannot be removed until the fixture is completely installed and secured through the spackle flange. - Once the brackets are removed, the lens/louvers can be installed.. / -0 sealing washer (by Selux). Page of 0

Decoustic Mounting (DC) Decoustic Mounting (DC) (Panels up to thick) "A" "C" Side Bottom "D" Feed 6 " (REF.) CEILING PANEL 7 /" [mm] /" [7mm]. /-0 Threaded rod to structure (supplied and installed by others).. /-0 Coupler hardware (supplied and installed by others).. /-0 Stud (by Selux).. Ø/6 [Ø7mm] mounting hole.. / wide alum. angle runs the entire length of fixture to block view into plenum area from below fixture. 6. Suitable for Decoustic ceiling panel installations with panels up to thick (supplied and installed by others). Other ceiling systems possible, please consult factory. Decoustic is a registered trademark of Decoustics Ltd. Corporation. 7. Sealing washers inside/out (by Selux) Nominal Length A O.A.L. w/o Flange Decoustic Mounting (DC) - Dimensions B End Suspensions * C (Ref.) Mid. Suspension D Feed Location Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 0 ( ft.) ' - /6" 0' - /8" 0' - 9 /8" 0' - /8" 0 0 ( ft.) ' - 7/6" 9 0' - /8" ' - 8 /6" 0' - /8" 0 0 ( ft.) ' - /6" 9 0' - 6 /8" 6 ' - /8" 6 0' - /8" 0 ( ft.) ' - 7/6" 0 0' - 6 /8" 6 ' - /6" 89 0' - /8" 0 ( ft.) ' - 7/6" 0 0' - 6 /8" 6 ' - /6" 99 0' - /8" 06 (6 ft.) ' - 7/6" 8 0' - 6 /8" 6 ' - /6" 0 0' - /8" 07 (7 ft.) 6' - 7/6" 9 0' - 6 /8" 6 ' - /6" 808 0' - /8" 08 (8 ft.) 7' - 7/6" 0' - 6 /8" 6 6' - /6" 0' - /8" 09 (9 ft.) 8' - 7/6" 79 0' - 6 /8" 6 7' - /6" 8 0' - /8" 0 (0 ft.) 9' - 7/6" 0 0' - 6 /8" 6 8' - /6" 7 0' - /8" ( ft.) 0' - 7/6" 8 0' - 6 /8" 6 9' - /6" 07 0' - /8" ( ft.) ' - 7/6" 6 0' - 6 /8" 6 0' - /6" 0' - /8" *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. Page of 0

Rotating Crossbars (RC) (/ to thick ceiling) 6 / Max. (Ref.). Rotating Crossbar intended for inaccessible ceilings, adjustable for ceiling thickness of / to. 6 / Max. (Ref.) Nominal Length A O.A.L. with Flange A O.A.L. without Flange Rotating Crossbar (RC) and Perimeter Mountings (PM) - Dimensions * A O.A.L. with End Cap Bump Out B End Suspensions ** C (Ref.) Mid. Suspension D Feed Location E Wall Angle (L6WR) E Wall Angle (L6WR) Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 0 ( ft.) ' - /6" ' - /6" ' - /" 7 0' - /8" 0' - 9 /8" 0' - /8" 0 ' - /6" ' - /6" 0 ( ft.) ' - /6" 60 ' - 0 /6" 8 ' - /8" 87 0' - /8" ' - " 0' - /8" 8 ' - /6" 60 ' - 0 /6" 8 0 ( ft.) ' - /6" 9 ' - /6" 9 ' - /" 97 0' - 6 /8" 6 ' - /8" 6 0' - /8" ' - /6" 9 ' - /6" 9 0 ( ft.) ' - /6" ' - 0 /6" 9 ' - /8" 97 0' - 6 /8" 6 ' - 0 /6" 88 0' - /8" ' - /6" ' - 0 /6" 9 0 ( ft.) ' - /6" 9 ' - 0 /6" 97 ' - /8" 0 0' - 6 /8" 6 ' - 0 /6" 87 0' - /8" ' - /6" 9 ' - 0 /6" 97 06 (6 ft.) ' 7/8" 8 ' - " 80 ' - /8" 807 0' - 6 /8" 6 ' - 0 /" 9 0' - /8" ' - 7/8" 8 ' - " 80 07 (7 ft.) 6' - /6" 9 6' - 0 /6" 07 6' - /8" 0' - 6 /8" 6 ' - 0 /6" 796 0' - /8" 6' - /6" 9 6' - 0 /6" 07 08 (8 ft.) 7' - /6" 7' - 0 /6" 7' - /8" 6 0' - 6 /8" 6 6' - 0 /6" 0 0' - /8" 7' - /6" 7' - 0 /6" 09 (9 ft.) 8' - /6" 79 8' - " 77 8' - /8" 7 0' - 6 /8" 6 7' - 0 /6" 06 0' - /8" 8' - /6" 79 8' - " 77 0 (0 ft.) 9' - /6" 0 9' - " 0 9' - /8" 06 0' - 6 /8" 6 8' - 0 /6" 7 0' - /8" 9' - /6" 0 9' - " 0 ( ft.) 0' - /6" 8 0' - " 7 0' - /8" 0' - 6 /8" 6 9' - 0 /6" 0 0' - /8" 0' - /6" 8 0' - " 7 ( ft.) ' - /6" 6 ' - " 6 ' - /8" 66 0' - 6 /8" 6 0' - 0 /6" 0 0' - /8" ' - /6" 6 ' - " 6 *RC mounting, consult factory for lengths under **Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. Perimeter Mount (PM) (Recessed Wall Mounting) 7 6 " [0.8mm] REF. 9 WALL /8" - 7/8" [7mm] - [9mm] Bottom of angle to center of hole. 8 6. Steel Wall Bracket with provision for /-0 fasteners (hardware to code by others). 7. /-0 Stud (by Selux). 8. / x Alum. wall angle allows a gap between flange and wall to create shadow line allowing for uneveness of wall. Provision for #0 screws supplied approximately every ft. (hardware to code by others). 9. /-0 sealing washer (by Selux). Page of 0

/-0 Threaded Stud (TS) ( Threaded Stud). /-0 Threaded rod to structure (supplied and installed by others).. /-0 Coupler hardware (supplied and installed by others).. /-0 Stud (by Selux).. Ø/6 [Ø7mm] mounting hole.. /-0 sealing washer (by Selux). Nominal Length A O.A.L. with Flange Threaded Stud (TS) and Vertical Threaded Stud Mounting (VTS) - Dimensions A O.A.L. without Flange * A O.A.L. with End Cap Bump Out B End Suspensions ** C (Ref.) Mid. Suspension D Feed Location Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 0 ( ft.) ' - /6" ' - /6" ' - /" 7 0' - /8" 0' - 9 /8" 0' - /8" 0 0 ( ft.) ' - /6" 60 ' - 0 /6" 8 ' - /8" 87 0' - /8" ' - " 0' - /8" 8 0 ( ft.) ' - /6" 9 ' - /6" 9 ' - /" 97 0' - 6 /8" 6 ' - /8" 6 0' - /8" 0 ( ft.) ' - /6" ' - 0 /6" 9 ' - /8" 97 0' - 6 /8" 6 ' - 0 /6" 88 0' - /8" 0 ( ft.) ' - /6" 9 ' - 0 /6" 97 ' - /8" 0 0' - 6 /8" 6 ' - 0 /6" 87 0' - /8" 06 (6 ft.) ' 7/8" 8 ' - " 80 ' - /8" 807 0' - 6 /8" 6 ' - 0 /" 9 0' - /8" 07 (7 ft.) 6' - /6" 9 6' - 0 /6" 07 6' - /8" 0' - 6 /8" 6 ' - 0 /6" 796 0' - /8" 08 (8 ft.) 7' - /6" 7' - 0 /6" 7' - /8" 6 0' - 6 /8" 6 6' - 0 /6" 0 0' - /8" 09 (9 ft.) 8' - /6" 79 8' - " 77 8' - /8" 7 0' - 6 /8" 6 7' - 0 /6" 06 0' - /8" 0 (0 ft.) 9' - /6" 0 9' - " 0 9' - /8" 06 0' - 6 /8" 6 8' - 0 /6" 7 0' - /8" ( ft.) 0' - /6" 8 0' - " 7 0' - /8" 0' - 6 /8" 6 9' - 0 /6" 0 0' - /8" ( ft.) ' - /6" 6 ' - " 6 ' - /8" 66 0' - 6 /8" 6 0' - 0 /6" 0 0' - /8" *RC mounting, consult factory for lengths under **Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance.. /-0 Threaded rod to structure (supplied and installed by others).. /-0 Coupler hardware (supplied and installed by others).. /-0 Stud (by Selux).. Ø/6 [Ø7mm] mounting hole.. /-0 sealing washer (by Selux). Page 6 of 0

Drivers: 0-0V linear dimming (DIM) Luminaires supplied with drivers offering the capability of either normal switched operation of 0-0V dimming for linear dimming curve. s ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to %. (Due to size constraints, luminaires are supplied with a driver from a different manufacturer than and above luminaires. For details, please consult factory). eldoled SOLOdrive 0-0V linear dimming (DM) Luminaires supplied with SOLOdrive 0-0V dimming driver for linear dimming curve. Minimum dimming level preset at factory to %. For dim to dark (down to 0.%), please consult factory. eldoled SOLOdrive 0-0V logarithmic dimming (DML) Luminaires supplied with SOLOdrive 0-0V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to %. For dim to dark (down to 0.%), please consult factory. eldoled SOLOdrive DALI dimming (DMD) Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to %. For dim to dark (down to 0.%), please consult factory. LUTRON -wire dimming (DC) Luminaires supplied with Hi-Lume -wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to %. LUTRON -wire dimming (DC) Luminaires supplied with Hi-Lume -wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to %. LUTRON Ecosystem dimming (DCE) Luminaires supplied with Hi-Lume EcoSystem ( wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to %. * For control recommendations and system layout for Lutron drivers, please contact Lutron. * For control recommendations for eldoled drivers, please consult eldoled. DIM DM, DML, & DMD drivers Driver Quantity ft. ft. ft. ft. ft. 6 ft. 7 ft. 8 ft. RUN N/A Approximately driver per ft. Approximately driver per ft. DC, DC, & DCE drivers N/A Consult Factory *For inrush and control current, please refer to the driver manufacturers spec sheets. Wiring Diagrams 0-0V linear (DIM) 0-0V linear eldoled SOLOdrive (DM) 0-0V logarithmic eldoled SOLOdrive (DML) DALI eldoled SOLOdrive (DMD) DIM, DM, DML, & DMD DALI DALI standard Page 7 of 0

Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse). Emergency Circuit (EC) - Luminaires with EC option compliant to UL 9 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use. - For to 6 nominal luminaires, the entire fixture is wired for operation on emergency circuit. Separate Switching (SS) - Luminaires available with separately switched (nominal) sections starting at 7 and up. Luminaire is intended to be wired to the same panel/breaker (not intended for Emergency use). - To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order. * If the project requires different separate switching than outlined above please consult the factory. - For 7 and up nominal luminaires, the first nominal length is wired for operation by a separate EM circuit by default to meet the required Life Safety Code (NFPA 0). **If a different configuration is needed please consult the factory. Flex Whip - standard for recessed fixtures Joiner System - standard for Runs Liquid Tight 90 Elbow on top of the Housing (7/8" feed hole) L60W-Flangeless L60W-Flanged /8" liquid tight flexible Metal Conduit (6 long) / x Rigid Conduit Nipple (x) / Sealing Locknut / x Rigid Conduit Nipple (x) / Sealing Locknut 6" leads Liquid Tight Straight Fitting Joining End Plate Joining Gasket Joining End Plate Joining Gasket Snap-In Cover and Gasket L60W & Gasketed Snap-In Detail-Flangeless L60W & Gasketed Snap-In Detail-Flanged Acrylic Gasketed Snap-In Clip Acrylic Gasketed Snap-In Clip Joining End Plate Acrylic Gasketed Snap-In Clip Joining End Plate Acrylic Gasketed Snap-In Clip Tamper Resistant (TR) Tamper Resistant Hardware Aluminum Top Plate Sealing Gasket Tamper Resistant Hardware Aluminum Top Plate Sealing Gasket Joining End Plate Joining Gasket Joining Gasket Joining End Plate Direct & Recessed Flangeless Recessed Flanged Page 8 of 0

Photometry LW Optics / W LED / 000K CCT Link to photometry (IES & PDF files) 87 6 8 Catalog #: L60-B-0-LW-X-0-XX-UNV Report #: 680.0 Delievered Lumens: 0 Input Watts:.77W Efficacy: 7 Power Factor: 0.99 Total Harmonic Distortion:.9 CCT: 96K CRI: 8. Max Candela: 870.7 @. from Vertical Spacing Criterion (0-80):.8 Spacing Criterion (90-70):.8 Spacing Criterion (Diagonal):.0 Maximum Candela = 870.7 Located At Horizontal Angle = 90, Vertical Angle =. # - Vertical Plane Through Horizontal Angles (90-70) # - Vertical Plane Through Horizontal Angles (0-80) MI Optics / W LED / 000K CCT Link to photometry (IES & PDF files) 80 90 0 Catalog #: L60-B-0-MI-X-0-XX-UNV Report #: 680.0 Delivered Lumens: 908 Input Watts:.9W Efficacy: 8 Power Factor: 0.99 Total Harmonic Distortion:.9 CCT: 96K CRI: 8. Max Candela: 80 @ 9. from Vertical Spacing Criterion (0-80):. Spacing Criterion (90-70): 0.88 Spacing Criterion (Diagonal):.06 Maximum Candela = 80 Located At Horizontal Angle = 90, Vertical Angle = 9. # - Vertical Plane Through Horizontal Angles (90-70) # - Vertical Plane Through Horizontal Angles (0-80) Page 9 of 0

000K 00K 000K 700K Light Engine Lumens Wattages B.8.8 B0.7.0 B.000.000 B0 0.8 0.88 B 0.766 0.70 B0 0.78 0. LW MI L60 LED Direct Photometry Multiplier Table CCT Multiplier Light Engine Multiplier Multiplier.000 0.97 0.96 0.9.000.9 CCT and CRI multipliers apply to the photometry, IES files, and values listed on page one (light engine). Light engine multiplier supplied for values listed on page one (light engine). Page 0 of 0