Bottle cooler controllers Solutions for static, ventilated and open coolers

Similar documents
NEW INNOVATION CENTER

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

DEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications

Technical Support Bulletin No. 23 Try ColdFace!

Technical Support Bulletin Nr. 3 Heating

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

XLH210: controller for gas leak detectors

Refrigerated air dryers

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

OPERATING INSTRUCTIONS. G214 Software - Version 4

AS950 REFRIGERATED SAMPLERS

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

IMPORTANT WARNINGS. Before installing or handling the appliance please carefully read and follow the instructions described in this manual.

MODEL URS-1: FACTORY RETROFIT PROGRAM

User Manual Ichill 200 L/D (Firmware version 1.7)

dixel Installing and Operating Instructions

CAREL IR33+ CONTROLLER

User Guide ems25plus. Page 1. Normal operation. Product interface

Conditioning your ambient, maximising your comfort.

MasterCase. User Manual

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

CT EN rel. 10/09 Copyright Eliwell Controls s.r.l All rights reserved

ER52 - Evaporator Controller

The new generation of cold room solutions. CAMAlarm Alarm Alarm

XC1008D -XC1011D- XC1015D and VGC810

IPC108D - IPC108E (V.2.0)

Top Mount Full Length Swinging Doors

SERVICE MANUAL REFRIGERATION

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Electronic Controller For Refrigeration XLR130 XLR170

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Multi-Lab REFRIGERATORS Frigidere medicale

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

E X V sistema Precision mechanics, powerful control. carel.com. connectivity, monitoring and remote managem,ent systems

Warranty Registration

Temperature - Humidity - Pressure

SLV CONTROLLER 105N46XX SERIES

Optimize your HVAC/R application with the right Danfoss components

TRAULSEN TECHNICAL BULLETIN

ACT2-CS Convenience Store Controller

Thermometers and temperature controllers

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

The integral solution for. Air Handling Units. Technology & Evolution

SECTION Fluorescent Dissolved Oxygen Measuring System

dixel Installing and Operating Instructions PRELIMINAY

FSD-6/ 09 FOODSERVICE DEALER CATALOG

PR / MP I Laboratory / Medicine

Dual Pressure Controls

THERMAX Efficiency Monitor

AS950 PORTABLE SAMPLERS

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure

Constant climate chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

Refrigerated Incubator Model and Operating Instructions

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Constant climate chambers

Access Control Solutions

Medical Refrigerators

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Air to water Heat Pump System

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Dixell Installing and Operating Instructions release 7.0

Laboratory Refrigerator/Deep Freezer TC 802

Feature Summary. I. System

OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE

ECH 985. Electronic controller for heat pumps used in residential hot water application

Internet. Climate rating definitions. Customer service.

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

SECTION Free/Available Chlorine Analysis System

nvenience Store Automation tore Automation

Digital regulator for refrigeration and defrosting, 3 relays.

PARAGON Commercial Refrigeration Controls

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Automation and Energy Efficiency of Industrial Refrigeration Systems

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

New LAE controller for Plug-in cabinets

EWRC 300/500 NT. Controllers for cold rooms for on-board installation USER MANUAL

SERVICE MANUAL REFRIGERATION

The Glass Sentry line of anti-sweat heater controls is designed to conserve the electricity consumption of the heater

IC200L Series User manual

UNIVERSAL R V3.0. NEW FEATURES on the V3.0

3 0 H X C A - H P 2

CSF. Contact Shock Freezers. Blood Management Solutions. B Medical Systems CSF Range

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Blast Chiller and Blast Freezer printed circuit board EWFC. Technical Training & Service Villotta ITALY 1

OVEN INDUSTRIES, INC.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Transcription:

Bottle cooler controllers Solutions for static, ventilated and open coolers

XRB Bottle cooler controllers The XRB series is the high-efficiency range of products available in 2 versions, standard and advanced named XRB Enhanced. The family allows a low environmental impact, as it is ready to be used with natural refrigerant applications (propane, CO2,...), and meets the needs of the highest-performance coolers available on the market. The controllers have an attractive design and new innovative functions especially dedicated to energy saving. Completely integrated control solution Thanks to the high usability and completeness due to the easy-to-user interface and the wide range of functions dedicated to the bottle cooler optimization, the controllers are the ideal solution for the management of: STATIC COOLERS VENTILATED COOLERS OPEN or NIGHT CURTAIN COOLERS R290 CO2 R600a

User friendly interface Direct access to main functions Easy and intuitive installation Hot Key connector for quick and easy programming Energy saving Thanks to an advanced and patented algorithm, the XRB series can automatically select the best temperature set by analyzing the temperature variation trends over a predefined interval of time. No external sensor is required for this operation. Extra cooling for filling Designed for cabinet refill operations, this function uses automatic temperature management, which moves the set point to a lower value for a predefined period; in this way, the beverages can quickly reach the right selling temperature. Automatic defrost management All standard defrost methods are supported in the XRB family. Moreover, defrost can also be managed automatically and its duration depends on the effective presence of ice on the evaporator surface. Self regulation capability The XRB family is able to choose the best suited set point and to decide the beginning and the duration of any defrosts based on the real using conditions and without external sensors. Anti-sweat heaters management It is possible to manage heating elements by using an auxiliary relay output; this can be managed via an interval of time (fixed activation and deactivation) or by using an auxiliary temperature regulator. Multi map Three different parameter maps are preloaded into the controller memory. The final user can select the one which better fits the final application and then quickly tune the parameters. Pull down time It is possible to anticipate the end of an Energy Saving interval by using a specific parameter. In that way it is possible to guarantee that, at the beginning of any working interval, the bottles are at the right selling temperature. Service & production The XRB controllers include several functions designed to help the manufacture and the service personnel: compressor run hour counter; easy visualization of the number of activations for all relay outputs; quick and easy firmware updating; customization of the programming parameters, directly in production, by using WIZMATE PROG-TOOL KIT.

Applications Depending on the kind of application, Dixell has designed different controllers that ensure the highest standards of performance of the cooler. Door cabinet - Static coolers Room probe Evaporator probe Compressor management Light management Timed defrost by compressor stop Open cabinet - With or without night curtain coolers Room probe Evaporator probe (optional) for heating elements, condenser temperature, etc... Compressor management Light management Digital input for night curtain management Timed defrost by compressor stop Door cabinet - Ventilated coolers Room probe Evaporator probe AUX probe Compressor management Fan management Light management Timed defrost by compressor stop Electric or hot gas defrost (if available) Anti-sweat heater management Designed also for STREET COOLER applications thanks to the heating function

Useful for OEM High flexibility thanks to the different energy saving modes The XRB can adapt quickly and easily to any possible situation; the energy saving configuration, which fits the application, can be selected in only a few steps. Reduced CO 2 emission Thanks to the advanced algorithm, the XRB reduces power consumption and consequently carbon emissions. High reliability Loads (compressor, defrost, etc...) are activated only if necessary; this increases the equipment life and decreases the maintenance operations. end user Few parameters to manage There is a really reduced set of parameters which need to be managed from the final user. While replacing existing controllers, new functions can be introduced It is possible to introduce advanced energy saving concepts in existing cabinets with or without a door switch sensor. Less programming time Thanks to the self regulation capability, the XRB controllers adapt themselves to the temperature conditions and the kind of use. Main accessories MDP/CX (only for version with standard case) Plastic protection against dripping on terminal blocks. WIZMATE PROG-TOOL KIT Programming tool to change in an easy and quick way the device configuration by using the Wizmate software. HOT KEY Key for a quick and easy parameter update. PROG KEY Key for a quick and easy firmware update. XJ485USB USB to RS485 serial converter (2 wires) to interface any computer, equipped with Wizmate software and a USB port, to a network of instruments. Dimensions & cut-out standard case short case 80 4 59,5 4 50 38 28,5 28,5 71 70 70 29

XRB-CH NATURAL REFRIGERANT COMPATIBLE 4 keys 2 digits large display with dedicated icons Available also in short version Dedicated key for energy saving activation/deactivation Red (standard) white and blue display Standard energy saving algorithms Condenser monitor for maintenance management XRB02CH XRB03CH XRB06CH XRB07CH Case short short standard standard Display ± 2 d.p. ± 2 d.p. ± 2 d.p. ± 2 d.p. Power supply 110, 230Vac 110, 230Vac 110, 230Vac 110, 230Vac Probe inputs up to 2 x NTC* up to 2 x NTC* up to 3 x NTC** up to 3 x NTC** Digital inputs 1 x configurable* 1 x configurable* up to 2 x configurable** up to 2 x configurable** Relay outputs 20A 20A + 8A 16 + 8 + 8A 20 + 8 + 5A 16 + 8 + 8 + 5A External port HOT KEY HOT KEY HOT KEY HOT KEY Terminals screw or plug-in screw or plug-in screw or plug-in screw or plug-in Buzzer optional optional optional optional ** Up to 2 NTC when the digital input is configured as probe ** Up to 3 NTC when the digital inputs are configured as probe XRB02CH XRB06CH XRB07CH XRB03CH

XRB-CH Enhanced NATURAL REFRIGERANT COMPATIBLE ADVANCED ENERGY SAVING ALGORITHM INSIDE 6 keys 3 digits large display with dedicated icons Dedicated key for energy saving activation/deactivation Red (standard) white and blue display Advanced energy saving algorithms (Patented) Automatic defrost management (Patented) Pull down time Antisweat heaters management Condenser monitor for maintenance management Multi map Real time clock Service counters (relay activation, working hours) Firmware update via special Prog key ModBUS serial communication XRB30CH XRB60CH XRB70CH Case standard standard standard Display ± 3 d.p. ± 3 d.p. ± 3 d.p. Power supply 110, 230Vac 110, 230Vac 110, 230Vac Probe inputs up to 3 x NTC* up to 4 x NTC** up to 4 x NTC** Digital inputs up to 2 x configurable** up to 2 x configurable** up to 2 x configurable** Relay outputs 16 + 8A 16 + 8 + 8A 20 + 8 + 5A 16 + 8 + 8 + 5A External port HOT KEY, TTL HOT KEY, TTL HOT KEY, TTL Terminals screw or plug-in screw or plug-in screw or plug-in Buzzer optional optional optional ** Up to 3 NTC when the digital input is configured as probe ** Up to 4 NTC when the digital inputs are configured as probe XRB30CH XRB60CH XRB70CH

EmersonClimate.com Emerson Commercial & Residential Solutions Dixell S.r.l. - Z.I. Via dell Industria, 27-32016 Alpago (BL) ITALY - Tel. +39.0437.9833 r.a. - Fax +39.0437.989313 EmersonClimate.com - Dixell@Emerson.com release 2.0-1582006010-GB All trademarks are property of their respective owners. Dixell reserves the right to alter its products without notice. All rights reserved. Because environmental conditions are outside of Dixell s control, we cannot assume liability for results obtained nor any damages that may occur due to improper application. Manuals and updates are available on our Web Site EmersonClimate.com