TEMPERATURE SENSORS WITH CONNECTION HEAD FOR EXPLOSION ENDANGERED ROOMS 13.3a

Similar documents
TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

FAST RESPONSE TEMPERATURE SENSORS 42.11a

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Flameproof Manual Call Points

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Instructions Edition 02/2007

for relative humidity and temperature with calibration certificates

VERSAFLOW VORTEX Supplementary instructions

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Inductive slot sensor

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Safety instructions VEGAPULS 64

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Monitoring Devices 11/1

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Model 144H. Product Data Sheet , Rev DB February Content

Temperature Measurement Transmitters for field mounting

Gas cylinder scale Model GCS-1

for relative humidity and temperature

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Temperature Sensor TRG Original Installation Instructions English

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Sitron s CF Line of Flow Switch Monitors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

SITRANS T temperature transmitters A broad product family for every application. sitrans

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Model 144H. Product Data Sheet , Rev DB February Content

Explosion Proof Combination Signal db (A) / 5 Joule

EU DECLARATION OF CONFORMITY

AND INSTALLATION MANUAL

Datasheet - AZM 161SK-12/12RK-024

Technical Data. Dimensions

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Beck. The differential pressure transmitter for air

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

PROTECT SRB 200EXi-1A

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

Heaters, Thermostats and Hygrostats

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

MANUAL Oil Level Sensor

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

IECEx Certificate of Conformity

OilSET-1000 (12 VDC)

Installation manual Washer extractor

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Flange immersion heaters

AD.3.XG... DIRECTIONAL CONTROLE CETOP 3

Technical Data. Dimensions

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

for relative humidity and temperature

Operating Manual MS220KA and MSR220KA

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

SCHMIDT LED Measured Value Display MD Instructions for Use

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

AO Annunciator Module

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Intelligent sensing for every temperature and condition

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Operating Instructions for Rotor flow Indicator. Model: DKF

Duct Air Quality Sensors

Snifter ATEX22 VERSION. User Manual. Distributor

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

M7100 Pressure Transducer

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

Thermostats. Innovative solutions for the toughest requirements

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Thermostats. Innovative solutions for the toughest requirements

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Technical Data. General specifications. Rated operating distance s n 5 mm

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

Datasheet - MZM 100 ST2-1P2PWREM-A

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Transcription:

DESCRIPTION AND APPLICATION The temperature sensors are designed to meet the requirements of EN 60 079-15:2006 standard. They operate on the base of defi ned relationship between change of sensing element resistance and change of temperature.they are not able to form sparkles, electric arcs or high surface temperatures. The sensors that are identifi ed on the type label by II 3G Ex na II T6 code can be utilised in explosion endangered rooms, device group II, zone 2. The operating temperature range for using them in zone 2 is -20 C to 80 C. These limits must not be exceeded even for a short time. According to the location of the sensing element and utilization of the sensors there are following versions: Serie S 110 Temperature sensors for outdoor usage. Temperature sensing element is located in a metal stem of the 25 mm length, delivering with a plastic side holder. Certifi cate FTZÚ 07 ATEX 0246X Serie S 120 Temperature sensors for using in air condition ducts or tubing. The sensing element is located in a metal stem of the standard length of 70, 120, 180 a 240 mm; it is delivered with a plastic holder, optionally the stainless steel thermowell JS 130 can be delivered. Certifi cate FTZÚ 07 ATEX 0247X Serie S 140 Contact version for measurement on piping. Sensing element is located in the metal measure case protecting by protect case made of SILIKON and SILAMID. Delivering with fastening strap (length 40 cm) and closing device. Certifi cate FTZÚ 07 ATEX 0249X Serie S 160 Fast response temperature sensors used in piping. Sensing element is located in a case the part of which is also screwing (thread G ½, M 20 x 1,5) which makes possible to assembly directly in piping. Certifi kát FTZÚ 02 ATEX 0251X The plastic head is made of LEXAN 500R. The sensors meet the ingress protection requirements IP 65 according to EN 60529. The head is provided by a cable ending or a connector. The sensors are designed to be operated in a chemically non-aggressive environment and they can be installed in places with low risk of mechanical stress. 62 SPECIFICATIONS BASIC DATA Standard types of sensing elements Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 500/3850, Pt 1000/3850, NTC 20 kω Measuring range -20 to 80 C 1 ma/3 ma for the sensors with the sensing element Pt 100 0,5 ma/1,5 ma for the sensors with the sensing element Pt 500 DC measuring current 0,3 ma/1 ma for other sensors DC power consumption 0,05 mw/1 mw for the sensors with the sensing element NTC 20 kω of sensing element Ni sensing elements: class B, t = ± (0,4 + 0,007t), for t 0; t = ± (0,4 + 0,028 t ), for t 0 in C; Accuracy class Pt sensing elements: class B according to IEC 751, t = ± (0,3 + 0,005 t ) in C NTC 20 kω: ± 1 C for the range 0 to 70 C Sensor connection according to the wiring diagram Type of terminal board (sensors with grommet) WAGO 260 wire cross section 0,35 to 1,5 mm 2 Type of connector in the head (sensors with conn.) RSFM4 Lumberg Insulation resistance min. 200 MΩ at 500 V DC, at the temperature 15 to 35 C, maximum rel. humidity 80 % Dielectric strength 1 000 V DC during the period 1 s, at the temperature 15 to 35 C, maximum rel. humidity 80 % according to the article 6.8.1. of the EN 60 079-15 ed. 2 standard Ingress protection IP 65 according to EN 60 529 Material of the head LEXAN 500R Dimmensions of the head 62 x 62 x 52 mm Mass approximately 0,2 kg

SUPPLEMENTARY DATA TO THE INDIVIDUAL TYPES Serie S110 Serie S120 Stem length 25 mm Standard stem length 70, 120, 180 a 240 mm Stem diameter 6 + 0,2 mm Stem diameter 6 + 0,2 mm Material of the stem stainless steel EN X5CrNi18-10 (DIN 1.4301) Material of the stem stainless steel EN X5CrNi18-10 (DIN 1.4301) Time response τ0,5 < 9 s (in streaming air 1 m.s -1 ) Time response τ0,5 < 9 s (in streaming water at 0,4 m.s -1 ) Sensor installation by means of a plastic side holder Sensor installation by means of a plastic central holder or stainless steel thermowell JS 130 Serie S140 Serie S160 Material of the case brass 423223.31 Standard stem length 50, 100, 160 a 220 mm Material of the protecting case SILICONE and SILAMID Stem diameter 4 + 0,1 mm Minimum diameter of piping 20 mm Material of the case stainless steel EN X5CrNi18-10 (DIN 1.4301) Time response τ0,5 < 3 s (in streaming water at 0,4 m.s -1 ) Standard threads G 1/2, M 20 x 1,5 Sensor installation by fastening strap and closing device Time response τ0,5 < 4 s (in streaming water at 0,4 m.s -1 ) WIRING DIAGRAM SENSORS WITH A GROMMET: With resistance output SENSORS WITH A CONNECTOR: With resistance output DIMENSIONAL DRAFT SENSORS WITH THE GROMMET: S 110 S 120 S 160 S 140 The grommet can be replaced by the connector RSFM 4, M12. 63

SENSOR INSTALLATION AND SERVICING SENSORS WITH GROMMET: Before connecting the supply lead-in cable, screw off the upper part of the plastic connection head. The lead-in cable is connected to the WAGO terminals according to the wiring diagram through the loosened grommet. The recommended wire cross section is 0.35 to 1.5 mm 2, the outer diameter of the circular cross-section cable should be between 4 and 8 mm. Only one lead-in cable can be lead through the grommet. To insure hermetic properties the grommet has to be tightened and the upper part of the head has to be screwed on by all screws after connecting the lead-in cable. SENSORS WITH CONNECTOR: Before connecting the supply lead-in cable place the sensor in the location in which the temperature to be measured. The lead-in cable with prescribed connector RKT or RKWT is connected to the connector RSFM4, which is the part of the sensor head. The connectors RKT and RKWT can be delivered as an accessory. To insure ingress protection IP 65 it is necessary to check the proper tightening of the connectors and proper bolting of the upper part of the head by all screws. In case the lead-in cable is laid in the vicinity of high voltage conductors or those supplying equipment creating disturbing electromagnetic field (e.g. inductive load equipment), a shielded cable should be used. In the case of using a holder or a stainless steel thermowell there is necessary to locate it at the place in which the temperature is measured and then to insert the sensor into the holder, resp. to the bottom of the thermowell and to fix it by a screw. Openings for the assembly of the central holder are drilled by the enclosed pattern in which diameters of the openings are marked, too. After installing and connecting the sensor to the sequential evaluating electrical equipment the sensor is ready to use. The sensor does not require any special servicing or maintenance. The device can be operated in any working position, but the grommet must not be directed upwards. Safe using: sensor can be installed in places with low risk of mechanical stress. CUSTOMER SPECIFIC MODIFICATIONS REGARDING TO SENSORS MANUFACTURED IN A STANDARD VERSION THE FOLLOWING PARAMETERS CAN BE MODIFIED: length of the sensor possibility of encapsulation of two sensing elements possibility to use a 3-wire or a 4-wire connection A class of accuracy (except for the NTC 20 kω sensing elements) encapsulation of other types of sensing elements KTY, DALLAS, SMT 160 etc. type of thread by the sensors of serie S 160 HOW TO ORDER WHEN ORDERING GOODS, THE FOLLOWING DATA ARE REQUIRED: Type name of sensor serie S 110, S 120, S 140, S 160 Type of sensing element Connection 2, 3 or 4-wire Version with grommet, with connector Stem length, case length only for S 120 and S 160 Type of a thread only for S 160 Accessory according to needs. 64 13.3a 05/10 replaced 13.2a

TEMPERATURE SENSORS WITH CABLE FOR EXPLOSION ENDANGERED ROOMS 14.3a DESCRIPTION AND APPLICATION The temperature sensors are designed to meet the requirements of EN 60079-15:2006 standard. They operate on the base of defi ned relationship between change of sensing element resistance and change of temperature. They are not able to form sparkles, electric arcs or high surface temperatures. The sensors that are identifi ed on the type label by II 3G Ex na II TY code can be utilised in explosion endangered rooms, device group II, zone 2. The operating temperature range for using them in zone 2 is identifi ed by the lead-in cable type. These limits must not be exceeded even for a short time - see Y in the Specifi cations. According to the design of the sensors there are the following variants: Serie TG8 The sensing element is located in the stainless steel tube with diameter 5,7 mm as a standard, the length of the case can be selected in the range 40 to 500 mm optionally. The stainless steel thermowell JTG8 can be delivered as an accessory. Certifi cate FTZÚ 07 ATEX 0142X Serie TR 011 the sensing element is located in the stainless steel case, the part of which is the screwing enabling the direct assembly in tubing etc. Diameter of the case and the type of thread is taken up by customer, the length of the case can be selected in the range 40 to 500 mm optionally. Certifi cate FTZÚ 07 ATEX 0143X The sensors meet the IP67 ingress protection requirements according to EN 60 529 standard. The sensors are designed to be operated in chemically non-aggressive environment. They can be used only for fi x installations of group II and user must provide fi xed clamping of the cable in the distance max. 100 to 300 mm from the sensor case according to par. A.2.3.2 EN 60079-0 ed.2. SPECIFICATIONS BASIC DATA Standard types of sensing elements Measuring range DC measuring current DC power consumption of sensing element Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 500/3850, Pt 1000/3850, NTC 20 kω Y -- T6: -20 Ta 70 C cable PVC T5: -20 Ta 95 C cable PVC up to 105 C T3: -30 Ta 180 C cable SILICONE 1 ma/3 ma for the sensors with the sensing element Pt 100 0,5 ma/1,5 ma for the sensors with the sensing element Pt 500 0,3 ma/1 ma for other sensors 0,05 mw/1 mw for the sensors with the sensing element NTC 20 kω Ni sensing elements: class. B, t = ± (0,4 + 0,007t), for t 0; t = ± (0,4 + 0,028 t ), for t 0 in C; Accuracy class Pt sensing elements: class B according to IEC 751, t = ± (0,3 + 0,005 t ) in C NTC 20 kω: ± 1 C for the range 0 to 70 C Sensor connection 2-wire, 3-wire, 4-wire Insulation resistance min. 200 MΩ at 500 V DC, at the temperature 15 to 35 C, maximum rel. humidity 80 % Dielectric strength (ATEX) 1 000 V DC during the period 1 s, at the temperature 15 to 35 C, maximum rel. humidity 80 % according to the article 6.8.1. of the EN 60 079-15 ed. 2 standard Ingress protection IP 67 according to EN 60 529-30 to 200 C MCBE-AFEP, 2 x 0,34 a 4 x 0,22 mm 2, silicone insulation Types of lead-in cables and their thermal resistivity -25 to 105 C FLRYWYW, 2 x 0,35 a 4 x 0,35 mm 2, PVC insulation up to 105 C -30 to 80 C LiYCY 2 x 0,34 mm 2, PVC insulation Resistance of lead-in cables ~ 0,11 Ω/m (2-wire connection) Mass according to the length of the cable, minimum 0,15 kg SUPPLEMENTARY DATA TO THE INDIVIDUAL TYPES Serie TG 8 Serie TR 011 Stem length 40 to 500 mm Stem length 40 to 500 mm Stem diameter 5,7 to 10 mm Stem diameter 6 to 10 mm Material of the stem stainless steel EN X5CrNi18-10 (DIN 1.4301) Material of the stem stainless steel EN X5CrNi18-10 (DIN 1.4301) Time response τ0,5 < 6 s (in streaming air at 1 m.s -1 ) for the diameter 5,7 mm Time response τ0,5 < 7 s (in streaming air at 1 m.s -1 ) for the diameter 6 mm 65

TEMPERATURE SENSORS WITH CABLE FOR EXPLOSION ENDANGERED ROOMS 14.3a WIRING DIAGRAM matt (green) matt (green) lead-in cable black (yellow) DIMENSIONAL DRAFT Sensor TG 8 Sensor TR 011 SENSOR INSTALLATION AND SERVICING 1. Assemble the sensor in the location in which the temperature to be measured. The sensor can be used only for fix installations of group II and user must provide fixed clamping of the cable in the distance max. 100 to 300 mm from the sensor case according to par. A.2.3.2 EN 60079-0 ed.2. 2. Connect the wires of the lead-in cable according to the wiring diagram. The shielding of the lead-in cable is not electrically connected to the external sensor case not even sensing element. For the temperature range -30 Ta 180 C the end of the cable of the length 150 mm including of the type lable should not be placed in the zone 2. After installing and connecting the sensor to the sequential evaluating electrical equipment the sensor is ready to use. The sensor does not require any special servicing or maintenance. The sensor can be operated in any working position. CUSTOMER SPECIFIC MODIFICATIONS REGARDING TO SENSORS MANUFACTURED IN A STANDARD VERSION THE FOLLOWING PARAMETERS CAN BE MODIFIED: length of the sensor possibility of encapsulation of two sensing elements A class of accuracy (except for the NTC 20kΩ sensing elements) encapsulation of other types of sensing elements KTY, DALLAS, SMT 160 etc. type of the thread and the case HOW TO ORDER WHEN ORDERING GOODS, THE FOLLOWING DATA ARE REQUIRED: Type name of sensor serie TG 8 or TR 011 Type of sensing element Connection 2, 3 or 4-wire Temperature operating range -20 to 70 C; -20 to 95 C; -30 to 80 C Length of the case Type of the thread only for TR 011 Optionally diameter of the case 66 14.3a 05/10 replaced 14.2a