OPERATING INSTRUCTIONS

Panel Mounted Heat Exchangers by Dantherm, Inc.

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

INTRODUCTION / TABLE OF CONTENTS

INSTALLATION, OPERATION AND MAINTENANCE

WA A Aqua Sub Bottom-load Water Cooler

READ AND SAVE THESE INSTRUCTIONS

16 Stand Fan with Remote Control Model No: FS3-40R-30

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

HI Industrial Utility Heater HI Soleus Air International

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

20 High Velocity Fan with 135 Tilt Head

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

MaxLite LED High Bay Fixtures

Protocol Station Remote Alarm

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Single Station Remote Alarm

Installation and Operations Manual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Portable Induction Ranges

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Cavitator Ultrasonic Cleaners

Spa Control System OWNER S MANUAL

Installation & Operation Manual Ice Cream Freezers

Figure 1. Figure 2. See notes 1 and 2 below.

18 INCHES, OSCILLATING STAND FAN

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Remote Relay Module (RRM)

OPERATION & INSTALLATION MANUAL

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

MN908 No. 282C Replaces 282B LB7013

Macurco HD-11 Hydrogen Gas Detector

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Owner & Operator s Manual. Table of Contents

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

INSTALLATION INSTRUCTIONS TALKBACK MODULE

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

(HSTAT Series) Instruction Manual

Environmental Monitoring SmartSlot Card

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

XC Portable Air Conditioning

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

TORRID MARINE YACHT QUALITY Since Owner s Manual

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

FLCH4R Garage and Utility Electric Heater

Installation Instructions PP-AS20 Anti-Scale System

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

DUST FREE CARBON Whole House Air Purifier

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Installation, Operation, and Maintenance Manual

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

OPERATION AND INSTALLATION MANUAL

SF-707 MIGHTY STEAM IRON OWNER S GUIDE

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Instruction Manual WARNING

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Cavitator Ultrasonic Cleaner Instruction Manual

RATIO:GUARD Model E-1S EC Monitor

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

Compact Equipment Warranty Policy

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

20 High velocity Air

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

55-Gallon Dispenser Package

55-Gallon Dispenser Package

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Please Read and Save These Instructions.

Operation & Installation Guide

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

B.I.C.A Built-In Coffee Appliance

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

HotPoly Tote Tank / IBC Heaters (TTH Series)

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Transcription:

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015 Fax: (562) 431-8507 www.flowline.com 17 SEPT 08 Switch-Tek Drum Alarms 1 of 10

Preface This manual explains how to use the Switch-Tek series of horizontal and vertical floats. Warranty, Service & Repair To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows: www.flowline.com On-line Warranty Registration can be found under Contact Us in the Navigation Bar along the side of the home page. If for some reason your product must be returned for factory service, contact Flowline Inc. at (562) 598-3015 to receive a Material Return Authorization number (MRA), providing the following information: 1. Part Number, Serial Number 2. Name and telephone number of someone who can answer technical questions related to the product and its application. 3. Return Shipping Address 4. Brief Description of the Symptom 5. Brief Description of the Application Once you have received a Material Return Authorization number, ship the product prepaid in its original packing to: Flowline Factory Service MRA 10500 Humbolt Street Los Alamitos, CA 90720 To avoid delays in processing your repair, write the MRA on the shipping label. Please include the information about the malfunction with your product. This information enables our service technicians to process your repair order as quickly as possible. 2 of 10 Switch-Tek Drum Alarms 17 SEPT 08

Warranty Flowline warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Flowline for a period, which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products. Flowline's obligation under this warranty is solely and exclusively limited to the repair or replacement, at Flowline's option, of the products or components, which Flowline's examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Flowline must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired or replaced under this warranty will be warranted only for the remainder of the original warranty period. Returns Products cannot be returned to Flowline without Flowline's prior authorization. To return a product that is thought to be defective, go to www.flowline.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and nonwarranty product returns to Flowline must be shipped prepaid and insured. Flowline will not be responsible for any products lost or damaged in shipment. Limitations This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Flowline have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Flowline. Flowline reserves the right to unilaterally waive this warranty and dispose of any product returned to Flowline where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Flowline for more than 30 days after Flowline has dutifully requested disposition. This warranty contains the sole express warranty made by Flowline in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL FLOWLINE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF FLOWLINE. This warranty will be interpreted pursuant to the laws of the State of California. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty. 17 SEPT 08 Switch-Tek Drum Alarms 3 of 10

Table of Contents Introduction...5 General Information...5 Technology...5 Installation...5 Alarm Enclosures...5 Environmental...6 Dimensions (Direct Drum)...6 Dimensions (Remote Drum)...7 Material Compatibility...7 Electrical interface...8 Typical Current and Voltage Ratings...8 Operation...8 Specification...8 Maintenance...9 Cautions...9 Testing the Installations...9 Cleaning Procedure...10 Changing the Battery...10 4 of 10 Switch-Tek Drum Alarms 17 SEPT 08

Introduction Flowline offers several level indication products designed specifically for standard 20-, 30- and 55- gallon drums. These level indicators will fit-up directly with standard 3/4 NPT bungs. This family of standard level switch (es) comes in low-level, high-level and multi-level designs, for both low-and highlevel indication. The basic level switch uses an on-board battery supply as a power source. Alarms are available in either a fixed-mount (to the level switch) or a remote-mount design. This package provides both the level switch and the alarm with battery power for ease of use in remote sites where a power source is not readily available. 1. Switches should be installed rigidly so the float or floats are free to move as the liquid level changes. 2. Switches should be mounted in a tank area free of severe turbulence or protected from such turbulence by appropriate and adequate slosh shields. 3. Vertical switch stems should be vertical for best results, but satisfactory operation is possible in most liquids with the stem at up to a 30 angle from vertical. 4. Care should be taken that switches are always operated within electrical ratings. General Information: o Available for high-level signal, low-level signal, or high and low level signals. o Designed with liquid tight fittings, allowing for usage both indoors and outdoors. o Optional alarm enclosures are available, see part number chart below. Technology Float switches consist of a float, magnet, reed switch and body/stem with mounting threads. When the probe is dry, the float rests on the bottom of the stem such that the magnet does not influence the reed switch. As the probe becomes immersed in liquid, the float becomes buoyant and the magnet elevates causing the reed switch to change state. Installation o Apply a suitable thread sealant to the threads. o Tighten into 3/4" bung of drum, ½ turn beyond hand tight. Alarm Enclosures: o AV17-S101, AV17-S201 and AV17-S301 o Fixed mount design. Will be threaded onto the stem assembly during assembly. o Available in a High-Level, Low-Level or High and Low-Level, see part number chart below. o Standard design with LED s for alarm. o Top-level part, AV17-S101, AV17-S201 and AV17-S301, must be ordered with the alarm. The end user cannot install the Alarm. o AV17-S401, AV17-S501 and AV17-S601 o Remote mount design. Uses liquid tight fitting to secure cable to enclosure. o Available in a High-Level, Low-Level or High and Low-Level, see part number chart below. o Standard design with LED s for alarm. o Top-level part, AV17-S401, AV17-S501 and AV17-S601, must be ordered with the alarm. The end user can remove the alarm enclosure. 17 SEPT 08 Switch-Tek Drum Alarms 5 of 10

Part Number Operation (dry condition) Function Alarm Enclosure Stem Length (inches) 20, 30, 55 Gallon Drum AV17-S101 NO High Level Yes 2.00 20, 30, 55 AV17-S401 NO High Level Yes 2.00 20, 30, 55 AV17-S201 NC Low level Yes 32.00 55 AV17-S501 NC Low level Yes 32.00 55 AV17-S301 NO / NC High level Yes 32.00 55 & Low level AV17-S601 NO / NC High level & Low level Yes 32.00 55 Environmental Dimensions Direct Drum Mount AV17-S101 AV17-S201 AV17-S301 6 of 10 Switch-Tek Drum Alarms 17 SEPT 08

Remote Drum Mount AV17-S401 AV17-S501 AV17-S601 Material Compatibility: o All versions of the AV17 series have the stem, fittings and floats manufactured from 316 stainless steel (316 SS) and grip rings made of PH-15-7 Mo SS. o Direct Drum Mount designs (AV17-S101, AV17-S201 and AV17-S301) do not come with any exposed cable. o The Remote Drum Mount designs (AV17-S401, AV17-S501 and AV17-S601) come with 2 or 4-conductor, 22 AWG, Halar-jacketed; 72 length (±2 ) cable. o Make sure that the switch is compatible with the application liquids. To determine the chemical compatibility between the sensor and its application liquids, refer to the Compass Corrosion Guide, available from Compass Publications (858-589-9636). 17 SEPT 08 Switch-Tek Drum Alarms 7 of 10

Electrical Interface o Typical Current and Voltage Ratings Watts Voltage Amps (resistive) 30 240 VAC 0.14 A 30 120 VAC 0.28 A 30 120 VDC 0.07 A 30 24 VDC 0.28 A o Note: The ratings above are for resistive loads only. For inductive loads, maximum switch life will be achieved if appropriate arc suppression is used. Operation Alarm box has two LED that indicate when an alarm occurs. The LED s are for High-Level and Low- Level. o For models AV17-S101 and AV17-S401, the Low-Level LED is not active o For models AV17-S201 and AV17-S501, the High-Level LED is not active The Alarm Box also features a three position switch to Turn On, Turn OFF or Test the alarms o ON Activates the alarm(s). Use this setting for running the Drum Alarm o OFF Deactivates the alarm(s). Use this setting when changing the drum o TEST Used as a test to verify power and confirm the operation of the LED(s). This is moment position and will reset to OFF when released. Specifications Part Number Description Float Mat l Stem Mat l Max. Oper. Temp ( C) Max Pressure (PSIG) Float SG Direct Drum Mount AV17-S101 High Alarm NO 316 SS 316 SS 150 250 0.73 AV17-S201 Low Alarm NC 316 SS 316 SS 150 250 0.73 AV17-S301 High Alarm NO & Low Alarm NC 316 SS 316 SS 150 250 0.73 Remote Mount AV17-S401 High Alarm NO 316 SS 316 SS 150 250 0.73 AZ17-S501 Low Alarm NC 316 SS 316 SS 150 250 0.73 AV17-S601 High Alarm NO & Low Alarm NC 316 SS 316 SS 150 250 0.73 Nominal VA Fitting 8 of 10 Switch-Tek Drum Alarms 17 SEPT 08

Maintenance Maintenance should consist of inspection to see that the float is free to move and not coated with any substance, which would change its weight or volume significantly. If this occurs, the float should be cleaned. This is easily accomplished without disturbing the installation. In addition, the stem may be wiped down to remove any build-up. The only repair possible in the field is replacement of either the float or stem. Dents or nicks on the float are usually of no consequence to operation. Cautions FLOWLINE manufactures a wide range of liquid level switches and technologies. While each of these switches are designed to operate in a wide variety of applications, it is the user's responsibility to select a switch model that is appropriate for the application, install it properly, perform tests of the installed system, and maintain all components. The failure to do so could result in property damage or serious injury. 1. The pressure, temperature and electrical limitations shown for the specified level switches must not be exceeded. 2. The pressures and temperatures must take into consideration possible surges in the temperature and pressure of the system. 3. The liquids used must be compatible with the materials of construction. Specifications of materials will be given upon request. 4. Life expectancy of the switch varies with applications. Contact the factory if life cycle testing is required. 5. Ambient temperature changes can affect switch set points, since specific gravities of liquids vary with temperature. Consult factory for assistance. 6. Level switches have been designed to be shock and vibration resistant. For maximum life, both shock and vibration should be minimized. Consult factory for assistance. 7. Excessive contaminants in fluid may inhibit float operation, and occasional wipe down may be necessary. 8. Level switches must not be field repaired 9. Physical damage to product may render product unserviceable. 10. Installation in a vessel made from magnetic materials may affect operation. Testing the installation: 1. Power: Turn on power to the controller and/or power supply. 2. Immersing the switch: Immerse the sensing tip in its application liquid, by filling the tank up to the switches point of actuation. An alternate method of immersing the switch during preliminary testing is to hold a cup filled with application liquid up to the switch's tip. 3. Test: With the switch being fluctuated between wet and dry states, the switch indicator light in the controller should turn on and off. If the controller doesn't have an input indicator, use a voltmeter or ampmeter to ensure that the switch produces the correct signal. 4. Point of actuation: Observe the point at which the rising or falling fluid level causes the switch to change state, and adjust the installation of the switch if necessary. 17 SEPT 08 Switch-Tek Drum Alarms 9 of 10

Cleaning procedure: 1. Power: Make sure that all power to the switch, controller and/or power supply is completely disconnected. 2. Switch removal: If necessary, make sure that the tank is drained well below the switch prior to removal. Carefully, remove the sensor from the installation. 3. Cleaning the switch: Using a soft bristle brush and mild deter-gent, carefully wash the switch. Do not use harsh abrasives such as steel wool or sandpaper, which might damage the surface of the sensor. Do not use incompatible solvents, which may damage the sensor's 316 stainless steel body. Take particular care to remove any scaling from the float body and make sure that it moves freely. 4. Sensor installation: Follow the appropriate steps of installation as outlined in the Installation section of this manual. Changing the Battery The AV17 Series uses one 9 volt battery to provide power for the system. Periodically, the batteries will need to be replaced. Follow the instructions below to replace the batteries: 1. Turn the AV17 series OFF 2. Make sure the application is in a safe state before continuing. 3. Loosen the 4 screws with a flat head screw driver and remove the cover of the alarm box. 4. Remove the 9 volt battery. 5. Replace with one fresh battery. Make sure to observe polarity. 6. Replace cover and tighten the four screws. 7. Test the system with the TEST feature 8. Turn the AV17 ON. AV17 shown with Cover Off 10 of 10 Switch-Tek Drum Alarms 17 SEPT 08