GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7

Similar documents
GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10

INSTRUCTIONS MODEL: MWB

INSTRUCTIONS. MODEL: CPC and CPC1 PIE CABINETS

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS DRY BAIN MARIE

INSTRUCTIONS MODEL: P9EO

INSTRUCTIONS MODEL: MWBT

INSTRUCTIONS MODEL: BT1 MOBILE BANQUETING TROLLEY

HOT CUPBOARD WITH BAIN MARIE

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

INSTRUCTIONS NACHO WARMER MODELS: 1995 / 1995S

INSTRUCTIONS MODEL: CBM / CMB2

PARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP

USHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE

CABINETS & PLATE WARMERS

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

GARLAND GAS CHARGRILL OWNER S MANUAL. Country of Destination GB and IE. Manual Part No: Gas Chargrill - 1 Manual Rev No: 1

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

OG7302 Salamander Grill

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

Gas Range Static Oven

Glen Dimplex Professional Appliances: Salamander Grill (GB/IE)

User, Installation, Servicing and Conversion Instructions. Opus 700 Gas Oven Ranges OG7001 & OG7002 IS431 ECN3592

PARAGON FRYERS INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: PSF3 MODEL: PDPF9 MODEL: PDPF6 MODEL: PF9

GAS RANGE STATIC OVEN

Synergy Grill User & Engineer Installation & Conversion Guide

INSTALLATION AND OPERATION MANUAL GAS CHARGRILL G592 G593 G594 G596 G598. For use in GB, IE & DK

Gas Fire Patio Heater Lhotse-817

Instruction Manual Extraction Canopy Range

GAS STEAMER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

Gas Range Static Oven

OG7005 Solid Top Gas Oven Range

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

Installation, Operating and Servicing Instructions

INSTRUCTIONS ELECTRIC FRYERS MODELS: NPSF3, NPSF6, NPSF9 NPDF3, NPDF6, NPDF9 NPSPF3, NPSPF6, NPSPF9 NPDPF3, NPDPF6, NPDPF9

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Gas Cooktops. Installation and Operation Manual

Gas Fire Patio Heater Q9

G3425, G3625, G3925, G31225 and G31525 Chargrills G3625, G3925, G31225 and G31525 ES Chargrills USERS INSTRUCTIONS

GAS TARGET TOP / STATIC OVEN RANGE

G3625, G3925, G31225 and G31525 Chargrills G3625, G3925, G31225 and G31525 ES Chargrills USERS INSTRUCTIONS

MHG201 Gas Hob Manual for Installation, Use and Maintenance

Installation, Operating and Servicing Instructions. Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002

Gas Range Convection Oven

Proline GAS HOB Model TCG40IX Instruction Book

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Gas Target Top Range Static Oven

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Gas Cooktops (450mm Wide Hobs)

BUILD-IN COOKING HOB MODELS H200F, H250F, H400F, 756 & 854F FOR USE WITH LIQUIFIED PETROLEUM GAS

Built-in Gas Hob CZ55554 CZ55571

INSTALLATION AND OPERATION MANUAL GAS GRIDDLE TOASTER G55T. For use in GB & IE

HHG610SS 60cm 4 burner gas hob. HHG710SS 70cm 5 burner gas hob

This appliance must be installed and serviced by a competent person as stipulated by the

GAS TARGET TOP / STATIC OVEN RANGE

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

GAS GRIDDLE GP513 GP514 GP516 GP518

UBGHFF60W 60cm Gas on Glass Gas Hob

USERS, INSTALLATION AND SERVICING INSTRUCTIONS

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

GAS GENERAL PURPOSE SOLID TOP RANGES

USER AND INSTALLATION INSTRUCTIONS

Gas Griddle Toaster. Model CT6 INSTALLATION AND OPERATION MANUAL

Opus 800 Gas Fryers OG8110, OG8110/OP, OG8111, OG8111/OP, OG8111/OP2, OG8106, OG8106/OP, OG8107, OG8107/OP

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE

GAS GRILL MEDIUM DUTY OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

chaffoteaux ltd. CORVECELT TS CONFORMS WITH EUROPEAN (BS5386Ptl) EN26 installation servicing requirements

Installation and Operation Manual. Gas Griddle Toaster. Date Purchased. Serial Number. Dealer. Service Provider. For use in GB & IE

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

Contents. 1. Instructions for safety and use 20

GAS STATIC OVEN RANGES

Gas Ranges Electric Static/Convection Oven

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE

Gas Cooktops. Models: C6 (600mm) C9 (900mm) INSTALLATION AND OPERATION MANUAL. For use in GB & IE

E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS

Osprey 2 CFL

GAS GRIDDLE GP514 GP516 GP518

GAS FRYER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT

GAS TARGET TOP RANGE/ CONVECTION OVEN

Gas Griddle GPL8450G GPL8600G GPL8900G GPL8120G GP8450G GP8600G GP8900G GP8120G. Installation and Operation Manual. 1 For use in GB & IE

GARLAND GAS STEAK GRILL OWNER S MANUAL. Click here for Part List. Country of Destination GB and IE

BAXI BOSTON ALL MODELS FLOOR STANDING OPEN FLUE (OF) CENTRAL HEATING BOILERS INSTALLATION AND SERVICING INSTRUCTIONS. GAS TYPE G20 (Natural Gas)

TC MODULE (FFD) (with Gas Hob)

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

USER MANUAL AGHD60GG BUILT-IN 60CM GAS ON GLASS HOB CUSTOMER CARE

CLGOGUIT

Pizza Oven with Stand

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

400GL PX (PF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

GAS COOKER GAS OVEN SERIES. Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Gas Fire Patio Heater Kongur-500

Transcription:

Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7 SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PARTS LIST SPARES LIST WARRENTY INFORMATION Customer Information MODEL NUMBER: SERIAL NUMBER: PURCHASE DATE: DISTRIBUTOR:

Page 2 of 17 SAFETY INSTRUCTIONS IMPORTANT, PLEASE READ INSTRUCTIONS FULLY BEFORE USE THIS APPLIANCE IS ONLY FOR PROFESSIONAL USE AND MUST ONLY BE USED BY QUALIFIED PEOPLE. Attention should be drawn to the fact that parts of this unit by necessity, will get VERY HOT, and will cause burns if touched accidentally. Therefore it is the responsibility of the supervisor or equivalent to provide SUITABLE PROTECTIVE CLOTHING for the user. THIS APPLIANCE MUST BE FITTED AND TESTED BY A REGISTERED FITTER BEFORE USE. The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force at the time. Particular attention should be paid to the Gas Safety (Installation and Use) Regulations and the Health and Safety at Work Act. Each appliance requires a flow of fresh air for combustion. Under no circumstances should air vents on the appliances, or air vents installed by the fitter in the room of the appliance to supply combustion air, be altered or omitted in any way. To prevent shocks, all appliances whether gas or electric, must be earthed. ANY GAS CONVERSIONS NEEDED TO BE MADE TO THE PRODUCT MUST BE CARRIED OUT BY A CORGI REGISTERED ENGINEER To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used.

Page 3 of 17 MODEL PGG6 & PGG7 GAS GRIDDLE The products stated above are designed and built to comply with the following standards: BS EN 203-1 BS EN 203-2-9 The products have been CE-marked in compliance with the European Gas Directive (90/396/EEC) INSTALLATION INSTRUCTIONS ALL APPLIANCES MUST BE FITTED AND OR CONVERTED BY A REGISTERED INSTALLER, IN ACCORDANCE WITH CURRENT REGULATIONS. INSTALLATION 1. Appliances are supplied in for use with either Natural Gas or LPG. Natural Gas appliances have an LPG conversion kit included as standard. 2. All appliances must not be installed on or against any combustible surface. 3. Clearances around appliances must be: 1. CEILING/SHELF 900mm 2. REAR 75mm 3. SIDES NIL It should be noted that the sides of the appliance will get hot and appliances with components sensitive to heat, should not be placed directly next to the unit. 4. During installation provision must be made for combustion air supply to the appliance, which enters the appliance through the base and rear of the appliance, this should not be blocked at any time. SEE TECHNICAL DETAILS.

Page 4 of 17 5. Appliances are designed to be installed, and fitted on a Parry stand for stability. If they are fitted on any other surface they should be suitably secured. 6. Connection to the appliance is by ½ BSPT at the rear of the appliance. 7. Pressure test point is located at rear of appliance. 8. The low rate adjuster is factory set and sealed for natural gas. If a unit needs to be converted a qualified engineer must reseal the low rate adjuster after conversion. 9. Remove all protective film before use. 10. Ensure whoever is operating the appliance is fully conversant with its operation and aware of dangers involved in incorrect operation and cleaning, especially the danger of burns or scalds from the cooking medium and hot surfaces of working areas. 11. These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrates of substances harmful to health in the room in which they are installed.

Page 5 of 17 OPERATING INSTRUCTIONS FOR FITTING INSTRUCTIONS SEE INSTALLATION SECTION. ALL GRIDDLES ARE FITTED WITH FLAME FAILURE DEVICE FOR SAFETY AND SPARK IGNITION FOR EASE OF LIGHTING TO LIGHT BURNER: 1. Turn knob to * position 2. Push knob in and ignite gas by pressing ignition button to left of the on/off knob. 3. Keep ON/OFF knob pressed in for 15-20 seconds. Check gas is lit by looking through the sight-hole on the front panel of the appliance. 4. Release ON/OFF knob, gas should stay lit, if gas goes out repeat (2) the pilot is now on. If the unit fails to light within 1 minute abort the lighting process for at least 2 minutes to allow gas to disperse. 5. Turn knob anti-clockwise to obtain main gas. The lowest setting has been set at the factory and sealed. This must not be adjusted by user. 6. To turn burner off, turn knob in a clockwise direction all the way round to 7. We advise that the appliance should not be left unattended when switched on. 8. The appliances are designed for professional use by qualified people only. 9. There are no user serviceable parts. 10. Clean outer casing with warm soapy water. Do not use scouring pads. It is recommended that Griddles be run on full gas after ignition for 10 minutes, then adjust as necessary to obtain correct cooking temperature. To remove any residue use a scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day.

Page 6 of 17 MAINTENANCE INSTRUCTIONS MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS. Parry advise that regular annual maintenance should be conducted by a Gas Safe registered engineer. This is essential to maintain safety and prolong life of the appliance. PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN FACTORY SET AND SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER SHOULD BE RE-SEALED. To facilitate maintenance it is recommended that the fascia is removed. To do this, take off the control knobs and remove 2 screws from the underside of the fascia panel. Remove the nut from the underside of the griddle plate. The plate can then slide forwards and be lifted off after withdrawing thermostat phials from underside of plate. Thoroughly clean the burner and burner chamber. Carefully clean the thermocouple probe, the ignitor, electrode and pilot jet. Reconnect the gas supply and check for gas soundness. Check that the flame safety device is operating by shielding the probe from the pilot flame until the device operates. Check that the spark ignites the gas. Thoroughly clean the plate and fat chute, and drawer. Replace the thermostat phial to its correct position and fasten the plate down to the body by tightening the nut. Refit fascia panel with the 2 screws and re-attach the control knobs.

Page 7 of 17 REPLACING FAULTY COMPONENTS Disconnect from gas and remove fascia panel. To replace the ignitor lead Pull the lead from the generator body, ignitor and electrode and push the new lead onto the terminals. Ensure that the lead is routed to avoid direct contact with the burner flame and any hot surfaces. To replace the spark generator body The generator is held on the front panel by a back nut. It is recommended that a new ignitor lead is fitted when replacing the generator. To replace thermocouple Undo the nut holding the thermocouple at the rear of the gas cock and undo the nut at pilot burner. Remove the faulty thermocouple. Push the new thermocouple gently into the gas cock and tighten the nut. Do not over-tighten. Fit the probe into the pilot burner and tighten the nut. To replace the combined flame safety/gas cock unit Undo the union at gas cock Undo and remove the nut holding the thermocouple to the rear of the gas cock and remove gas cock knob. Undo and remove pilot supply from the tap. Remove thermostat phial from plate if not already done so. The gas cock is held on the float rail by a saddle bracket with two screws. Remove the screws and the faulty tap.

Page 8 of 17 Refit the new unit ensuring that the loose spigot is pushed firmly into its housing and seat the rubber washer in the recess provided. Refit the saddle bracket and tighten the two screws. Reconnect gas feed to injector and gas cock and tighten Refit pilot supply Refit thermocouple and tighten do not over tighten Refit thermostat phial to plate. Reconnect gas supply and soundness test Check flame failure device is operating Refit fascia and cooking plate.

Page 9 of 17 CONVERSION INSTRUCTIONS This conversion must be carried out by a competent qualified person. Natural to LPG 1. Remove fascia panel (2 screws underneath) 2. Remove fascia panel and disconnect ignition leads 3. Disconnect the gas feed at injector elbow. 4. Unscrew and remove aerator 5. Undo the back nut holding the injector elbow to the burner and remove 6. Remove natural injector and replace with the LPG injector issued 7. Re-assemble in the reverse order, refit the aerator. 8. Replace the existing labels and data plate with the LPG labels provided. 9. Low rate screw is on front L/H side of tap. 10. Low rate must be adjusted by inserting a small flat screwdriver and turning clockwise to the stop. This must only be done by a qualified corgi engineer, and as this setting has been factory sealed. Any alterations must be resealed. LPG to Natural 1. Remove fascia panel (2 screws underneath) 2. Remove fascia panel and disconnect ignition leads 3. Disconnect the gas feed at injector elbow. 4. Unscrew and remove aerator 5. Undo the back nut holding the injector elbow to the burner and remove 6. Remove LPG injector and replace with the natural injector issued 7. Re-assemble in the reverse order, refit the aerator. 8. Replace the existing labels and data plate with the natural labels provided. 9. Low rate screw is on front L/H side of tap. 10. Low rate must be adjusted by inserting a small flat screwdriver and turning clockwise to the stop. This must only be done by a qualified corgi engineer, and as this setting has been factory sealed. Any alterations must be resealed. Model PGG6 PGG6 PGG7 PGG7 Butane G30 @28mbar 11.2 W.G. Propane G31 @ 37mbar 14.8 W.G. Nat Gas G20 @ 20mbar 8 W.G. Nat Gas G25 @ 25mbar 10 W.G. Butane G30 @28mbar 11.2 W.G. Propane G31 @ 37mbar 14.8 W.G. Nat Gas G20 @ 20mbar 8 W.G. Nat Gas G25 @ 25mbar 10 W.G. Injector Code INJECT082 INJECT130 INJECT099 INJECT150

Page 10 of 17 TECHNICAL DETAILS MODEL PGG6 GRIDDLE Per Burner (All figures are NET) GAS OPERATING PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb/8 W.G. 2.400 KW = 8190Btu/h BUTANE G30 29mb/11.2 W.G. 2.806 KW = 9572Btu/h PROPANE G31 37mb/14.8 W.G. 2.726 KW = 9300 Btu/h G25 25mb/10 W.G. 2.584 KW = 8816Btu/h GAS RATE M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.254 M³/HR 8.970 FT³/HR BUTANE G30 0.087 M³/HR 3.072 FT³/HR 0.452 LB/HR 0.205 KG/HR PROPANE G31 0.112 M³/HR 3.938 FT³/HR 0.433 LB/HR 0.196 KG/HR G25 @ 25mb 0.318 M³/HR 11.230 FT³/HR AIR FLOW RATE FOR 3.18M³/HR COMBUSTION 20m³/HR Total Unit (All figures are NET) GAS OPERATING PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb/8 W.G. 4.810 KW = 16412 Btu/h BUTANE G30 29mb/11.2 W.G. 5.611 KW = 19145 Btu/h PROPANE G31 37mb/14.8 W.G. 5.451 KW = 18599 Btu/h G25 25mb/10 W.G. 5.168 KW = 17632 Btu/h GAS RATE M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.509 M³/HR 17.975 FT³/HR BUTANE G30 0.174 M³/HR 6.145 FT³/HR 0.903 LB/HR 0.410 KG/HR PROPANE G31 0.223 M³/HR 7.875 FT³/HR 0.865 LB/HR 0.392 KG/HR G25 @ 25mb 0.636 M³/HR 22.460 FT³/HR AIR FLOW RATE FOR 6.36 M³/HR COMBUSTION 20m³/HR INJECTORS Natural G20 = INJECT130 Butane G30 = INJECT082 Propane G31 = INJECT082 G25 @ 25mb = INJECT130

Page 11 of 17 PARTS LIST PGG6 NUMBER PART PART CODE NUMBER OFF 1 Float Rail 600CHARGRILL X1 2 Flame Safety/ Gas Cock GASTAP8/1 X2 8mm 3 Burner BURNER001 X2 4 Burner Box BBOX2GRID X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cable CABLHT500 X2 8 Piezo Sparker PIEZOISP1 X2 9 Saddle Bracket BRACKET01 X2 10 Gas Cock Knob KNOBPHEN X2 11 Aerator AIRGRIDNG X2 12 Flue Cover X1 13 Low Rate Adjuster X1 14 Injector PGG6 Natural INJECT130 X2 14 Injector PGG6 LPG INJECT082 X2

Page 12 of 17 TECHNICAL DETAILS MODEL PGG7 GRIDDLE Per Burner ( All figures are NET) GAS OPERATING PRESSURE HEAT INPUT NATURAL G20 20mb/8 W.G. 3.549 KW = 12110Btu/h BUTANE G30 29mb/11.2 W.G. 3.354 KW = 11443Btu/h PROPANE G31 37mb/14.8 W.G. 2.564KW = 8747Btu/h G25 25mb/10 W.G. 3.51 KW = 11975Btu/h GAS RATE M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.368 M³/HR 12.944 FT³/HR BUTANE G30 0.110 M³/HR 3.884 FT³/HR 0.575 LB/HR 0.261 KG/HR PROPANE G31 0.110 M³/HR 3.884 FT³/HR 0.444 LB/HR 0.202 KG/HR G25 @ 25mb 0.425 M³/HR 15.007 FT³/HR AIR FLOW RATE FOR 150.07 FT³/HR COMBUSTION 20m³/HR Total Unit ( All figures are NET) GAS OPERATING PRESSURE HEAT INPUT NATURAL G20 20mb/8 W.G. 7.098 KW = 24221Btu/h BUTANE G30 29mb/11.2 W.G. 6.707 KW = 22885Btu/h PROPANE G31 37mb/14.8 W.G. 5.127 KW = 17494Btu/h G25 25mb/10 W.G. 7.02 KW = 23951 Btu/h GAS RATE M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.736 M³/HR 25.988 FT³/HR BUTANE G30 0.220 M³/HR 7.768 FT³/HR 1.150LB/HR 0.523 KG/HR PROPANE G31 0.220 M³/HR 7.768 FT³/HR 0.888 LB/HR 0.404 KG/HR G25 @ 25mb 0.850 M³/HR 30.014 FT³/HR AIR FLOW RATE FOR 300.14FT³/HR COMBUSTION 20m³/HR INJECTORS Natural G20 = INJECT150 Butane G30 = INJECT099 Propane G31 = INJECT099 G25 @ 25mb = INJECT150

Page 13 of 17 PARTS LIST PGG7 NUMBER PART PART CODE NUMBER OFF 1 Float Rail 750GASGRID X1 2 Flame Safety/ Gas Cock 8mm GASTAP8/1 X2 3 Burner BURNER001 X2 4 Burner Box X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cable CABLHT500 X2 8 Piezo Sparker PIEZOISP1 X2 9 Saddle Bracket BRACKET01 X2 10 Gas Cock Knob KNOBPHEN X2 11 Aerator X2 12 Flue Cover X1 13 Low Rate Adjuster X2 14 Injector PGG7 Natural INJECT150 X2 14 Injector PGG7 LPG INJECT099 X2

Page 14 of 17 SPARES LIST PGG6 & PGG7 PART NO. PART DESCRIPTION PGG6 PGG7 BURNER001 BURNER ASSEMBLY (3) LEFT OR RIGHT X2 X2 MBETCASSY THERMOCOUPLE ELECTRODE ASSY (5,6) X2 X2 PIEZ01SP1 SPARK GENERATOR (8) X2 X2 KNOBPHEN KNOB - PGG6, PGG7(10) X2 X2 GASTAP8/1 8MM TAP ASSEMBLY (2) X2 X2 CABLHT500 HT LEAD (7) X2 X2 DRIP TRAY /PGG6,PGG7 X1 X1 750GASGRID FLOAT RAIL PGG7 (1) X1 600CHARGRILL FLOAT RAIL PGG6 (1) X1 BRACKET01 SADDLE BRACKET (9) X2 X2 NATURAL CONVERSION KIT CONSISTS OF: INJECT130 NATURAL INJECTOR-,PGG6, (14) X2 SET OF LABELS X1 IN103-4 INSTRUCTION PACK X1 LPG CONVERSION KIT CONSISTS OF: INJECT082 LPG INJECTOR- PGG6, (14) X2 SET OF LABEL X1 IN103-4 INSTRUCTION PACK X1 NATURAL CONVERSION KIT CONSISTS OF: INJECT150 NATURAL INJECTOR-PGG7, (14) X2 SET OF LABEL X1 IN103-4 INSTRUCTION PACK X1 LPG CONVERSION KIT CONSISTS OF: INJECT099 LPG INJECTOR- PGG7, (14) X2 SET OF LABEL X1 IN103-4 INSTRUCTION PACK X1

Page 15 of 17 WARRANTY INFORMATION WARRANTY POLICY The manufacturers warranty is only valid in the UK mainland & Northern Ireland, Western Isles, Inner Hebrides and Islands are parts only warranty. All service calls will be carried out between the hours of 8.00am 5.00pm Monday to Friday only. We accept no responsibility for delays in replacing or repairing the equipment due to circumstances beyond our control. Your warranty can be immediately invalid if the installation of the equipment has not been installed in accordance with the manufactures instruction. (See installation details). Also the miss-use, alteration or unauthorised repairs of the equipment will invalidate the warranty. During the warranty period it is at Parrys discretion to repair or replace the equipment. Warranty only applies if the equipment has been used in a professional manor following the manufactures instructions and maintenance guide lines. The warranty covers defects in the material and components failure only we are not liable for trading loss, loss of perishable items, water damage, loss due to injury or fire damage. WARRANTY REQUEST Please ensure you have referred to the manufacturers instruction before placing a warranty call. Or contact our warranty department on 01332 875665 for technical assistance. Please ensure you obtain the model number before calling. Please ensure you have read the section not covered under warranty to avoid any unnecessary warranty charges. If the problem with the machine can not be resolved please contact the company that supplied you the machine. (SERVICE CALLS CAN NOT BE PLACED DIRECT WITH PARRY)

Page 16 of 17 NOT COVERED UNDER WARRANTY Fault due to poor maintenance. Resetting of equipment or circuit breakers. Abuse of the equipment Foil should never be used on racks Blockages eg, drains, condensers, pumps etc Lime scale related issues Installed incorrectly Access arranged for service call and engineer refused access or customer not there. No faults with the machine. Setting up of equipment eg, dishwasher detergents, levelling and setting up of doors on a 6 burner cooker. Excessive carbon build up on griddle plates. Over use of lava rock on the chargrills recommended use by Parry 2kg only. Faulty electrics eg, customers plug socket, plug, wiring, junction box fault, wrong fuse. Any damages caused by the customer. Lamps, glass, door gaskets, Perspex, baskets, knobs all perishable items are not covered.

Page 17 of 17 All of the above are not covered under our warranty policy. Any costs incurred because of the above will be forwarded to the parties responsible for placing the call. Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled. Any issues regarding the raised charges should be put in writing to our warranty department for further investigation. Parry Group Ltd Town End Road Draycott Derbyshire England DE72 3PT