Service Manual. Solid Door Upright Reach-In Units:

Similar documents
Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Instruction Manual. Pastry Display Cases. Models: CURP series REFRIGERATION LTD. CURLP CURP CURHP

Instruction Manual. Pastry Display Cases. Models: JMR series REFRIGERATION LTD. JMRTP JMRWP JMRSP JMRPP

Instruction Manual. Meat/Deli/Fish Display Cases. Models: RSCD, RSCFID REFRIGERATION LTD. RSCFID RSCD

Manual For Panel Air Conditioner. Table of Contents

Instruction Manual. Open Merchandisers. Models: 1OM 2OM REFRIGERATION LTD.

CAREL IR33+ CONTROLLER

MODEL URS-1: FACTORY RETROFIT PROGRAM

TMEF Series. SKOPE Vertical Freezer. User Manual

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

ER52 - Evaporator Controller

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

MasterCase. User Manual

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

ACCESSORIES & WARRANTY

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST Bottom Mount Reach-Ins

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

PRO 3 Top Mount Packaged Refrigeration System

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

MR3CCUHV Temperature/Defrost Control

Refrigeration eration System

Hoshizaki America, Inc.

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Capacity controller for water chiller AK-CH 650

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Mega Top Sandwich Prep Table Manual

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

Romeo. Manual. Version: : 1.0 BASIC SECURITY PRECAUTIONS PROCESURES OPERATION UNPACKING MAINTENANCE COMMANDS RECYCLING ANOMALIES ASSEMBLY

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Royal Vendors Freezer

CATALOG OF REPLACEMENT PARTS

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Fast Track Troubleshooting

TECHNICAL MANUAL F49-S, F49-SH F72-S, F72-SH R49-S, R49-SH, R49-G R72-S, R72-SH, R72-G - 1 -

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

plug-in, electronic digital thermostat with defrost control User manual

(EE1500, EE2000, EE2500, EE3000)

Installation and Operation Guide For

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

LOW PROFILE UNIT COOLER

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

FX BLAST CHILLER ISO ISO 9001

Wiring Diagrams Units Produced After April 20, 2009

Commercial Freezer Service Manual

USER MANUAL KB110 SERIES KB152 SERIES KB308 SERIES KB405 SERIES COMPRESSOR REFRIGERATORS

Solo Plus Units 2001 l a u n a M e ic v r e S

Dixell Installing and Operating Instructions release 7.0

IMPORTANT WARNINGS. Before installing or handling the appliance please carefully read and follow the instructions described in this manual.

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Thermometers and temperature controllers

Bottom Mount Refrigerator---Technical Information

Commercial Refrigerator Service Manual

LOW PROFILE UNIT COOLER

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

ThermoSaver TM Hot Gas Defrost System

Simple Self-Diagnosis by Malfunction Code

IN NOURISHING SECURITY.

OPERATING AND INSTRUCTIONS MANUAL: B130/10/220H VACCINE REFRIGERATOR REV.1 (WITH TEMPERATURE HOLDOVER FUNCTION)

Rev B, 9/2/2009. Kodiak Chiller Overview

REMOTE CONTROL FOR CHILLER MYCHILLER

Glass Door Merchandiser

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

5-stage compressor racks + 2 converter outputs

Glass Door Merchandiser. Model RM-45-SD

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Upright Chiller & Freezer Service, Installation and Care Manual

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

4. ALIGNMENT AND ADJUSTMENTS

TOQUE BLANCHE GRANDE CARTE

MR40 Advanced Electronic Control for compressor and defrost management. Features and Benefits

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Fast Track Troubleshooting

REF5-BB Undercounter Blood Bank Refrigerator

CAUTION. No-Load Performance, Controls in Normal Position

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Service Manual For BAPT1, BAPT2, BAPT3 BAUR1, BAUR2, BAUR3, BAUF1, BAUF2

Hoshizaki America, Inc.

BSD SERIES REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Service Manual. ETL Blast Chiller Series

MLCFC HMI NAVIGATION MANUAL

MASTER SERVICE MANUAL

Hoshizaki America, Inc.

Instruction Sheet. ERC2 Retrofit Instructions Series Refrigerators/Freezers and SPEC LINE Refrigerators 6000 & SPEC LINE SERIES

Service Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Transcription:

Service Manual Solid Door Upright Reach-In Units: ESR, ESRH, ESR, ESWR, ESR ESF, ESFH, ESF, ESWF, ESF ESRF, ESWQ, ESWRF, ESRF ESRD, ESRD, ESRD4 ESRFD, ESWQD www.everestref.com 0 W. Artesia Blvd. Compton, CA 900 0--6586 800-444-685 0--754(fax)

ESR / ESF ESRH / ESFH ESR / ESF / ESRF ESWR / ESWF / ESWRF R F R ESWQ ESR / ESF / ESRF

9 /4 49 /4 49 /4 /4 58 /4 /4 54 / /4 54 / 8 /4 4 4 4 4 8 /4 8 /4 8 /4 R R R R 74 /4 74 /4 R 74 /4 R 4 R 4 R R 4 4 4 R R R R 5 5 ESRD ESRD ESRD4 4 5 49 /4 59 /4 54 / /4 58 /4 4 4 8 /4 8 /4 8 /4 8 /4 R F F 74 /4 74 /4 R 4 R R 4 R R 5 5 ESRFD ESWQD

59" 8 /4" 8 /4" ESGR ESGR ESGWR ESGR

Model Capacity(Cu.Ft.) Door Shelves Compressor (HP) Compressor Model ESR (Refrigerator) / ESF (Freezer) / ESRH (Refrigerator) (Half) / ESFH (Freezer) (Half) / ESR (Refrigerator) 48 6 / ESF (Freezer) 48 6 / x ea FFI0HAKW NE4GK FFI0HAKW NE4GK FFI0HAKW NE4GK Refrigerant (Oz).05.05.05.05.05.05 x ea Pressure of suction during operation cycle at setting temp Power (V-Hz-Ph) Temp. Range(F) Refrigerant Crated Weight(LBS) Amps(A) Ext. Dimensions (W x D x H inches) 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 5-60- ~ 4 R-4a 84.8 9 /4 x /4 x 74 /4 5-60- -4~ R-404a 89 8. 9 /4 x /4 x 74 /4 5-60- ~ 4 R-4a 89.8 9 /4 x /4 x 74 /4 5-60- -4 ~ R-404a 9 8. 9 /4 x /4 x 74 /4 5-60- ~ 4 R-4a 84 4.50 49 /4 x /4 x 74 /4 5-60- -4 ~ R-404a 448 5.89 49 /4 x /4 x 74 /4 Model ESRF (Dual Temp) ESWR (Refrigerator) ESWF (Freezer) ESWRF (Dual Temp) ESWQ (Dual Temp) ESR (Refrigerator) Capacity(Cu.Ft.) Door Shelves Compressor (HP) Compressor Model (R) (F) 6 /(R) /(F) FFI0HAKW (R) NE4GK (F) 55 6 / 55 6 / x ea 6(R) 6(F) 6 /(R) /(F) 9(R) (F) 5 /(R)X ea 7 9 / x ea FFI0HAKW FFI0HAKW (R) NE4GK NE4GK (F) FFI0HAKW FFI0HAKW Refrigerant (Oz).05(R).05(F).05.05 x ea.05(r).05(f).05(r).5(f).05 x ea Pressure of suction during operation cycle at setting temp 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds Power (V-Hz-Ph) Temp. Range(F) Refrigerant Crated Weight(LBS) Amps(A) Ext. Dimensions (W x D x H inches) 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 456.85 49 /4 x /4 x 74 /4 5-60- ~ 4 R-4a 4 4.50 59 x /4 x 74 /4 5-60- -4 ~ R-404a 50 5.89 59 x /4 x 74 /4 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 496.08 59 x /4 x 74 /4 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 470.08 59 x /4 x 74 /4 5-60- ~ 4 R-4a 578 9.49 75 x /4 x 74 /4 Note: R - Refrigerator F - Freezer

Model ESF (Freezer) ESRF (Dual Temp) ESRD (Refrigerator) ESRD (Refrigerator) ESRD4 (Refrigerator) ESRFD (Dual Temp) Capacity(Cu.Ft.) Door Shelves Compressor (HP) Compressor Model Power (V-Hz-Ph) Temp. Range(F) Refrigerant Crated Weight(LBS) Amps(A) Ext. Dimensions (W x D x H inches) 7 9 / x ea NE4GK 0-60- -4 ~ R-404a 650.6 75 x /4 x 74 /4 46(R) (F) 9 /(R) /(F) FFI0HAKW (R) NE4GK (F) 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 589.6 75 x /4 x 74 /4 (Half) (Drawer) / FFI0HAKW 5-60- ~ 4 R-4a 66 4.94 9 /4 x /4 x 74 /4 48 (Full) (Half) (Drawer) (Half) 4 (Drawer) (Full) (Half) (Drawer) 5 / FFI0HAKW 5-60- ~ 4 R-4a 4 5.0 49 /4 x /4 x 74 /4 48 / FFI0HAKW 5-60- ~ 4 R-4a 54 5.55 49 /4 x /4 x 74 /4 (R (F) 5 /(R) /(F) FFI0HAKW (R) NE4GK (F) Refrigerant (Oz).05 x ea.05(r).05(f).05.05.05.05(r).05(f) Pressure of suction during operation cycle at setting temp 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 5.50 49 /4 x /4 x 74 /4 Model ESWQD (Dual Temp) ESGR (Refrigerator) ESGR (Refrigerator) ESGWR (Refrigerator) ESGR (Refrigerator) Capacity(Cu.Ft.) Door Shelves Compressor (HP) 9(R) (F) (Full) (Hal) (Drawer) (Glass) 5 /(R) /(F) / 48 (Glass) 6 / 55 (Glass) 6 / 7 (Glass) 9 /+ x ea Compressor Model FFI0HAKW (R) NE4GK (F) FFI0HAKW NE4GK NE4GK Pressure of suction during operation cycle at setting temp 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds 0 to 5 pounds Power (V-Hz-Ph) Temp. Range(F) Refrigerant Crated Weight(LBS) Amps(A) Ext. Dimensions (W x D x H inches) 5-60- ~4(R) -4~(F) R-4a(R) 404a(F) 57.4 59 x /4 x 74 /4 5-60- ~ 4 R-4a 4.44 9 /4 x /4 x 74 /4 5-60- ~ 4 R-404a 44 7.45 49 /4 x /4 x 74 /4 5-60- ~ 4 R-404a 478 7.45 59 x /4 x 74 /4 5-60- ~ 4 R-4a 585 9.49 75 x /4 x 74 /4 [NOTE] Ext. height does not include 5 overall height casters. Drawer pans are not include in Door & Drawer Combo Upright Reach-In units. R - Refrigerator F - Freezer change without notice.

DOOR FRAME HEATER (9.9W) DOOR FRAME HEATER (4.7W) GREEN EARTH PCB CONTROL POWER SWITCH EVAPORATOR FAN MOTOR RC DEFROST HEATER W BL BL W LP EVAPORATOR DRAIN PAN HEATER (80W) EM EM S C COLOR B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY ESR, ESRD, ESGR CONDENSATE DRAIN PAN HEATER (80W) EVAPORATOR SENSOR OT B BR ROOM SENSOR CM R R S OL T LEGEND PZBUC0H0K (CARELPCB CONTROL) DOOR / LIGHT SWITCH LIGHT LAMP REFRIGERATOR COMPRESSOR FREEZER COMPRESSOR CONDENSER FAN MOTOR START CAPACITOR RELAY OVERLOAD ELECTRIC HEATER EVAPORATOR FAN MOTOR OVERHEAT TERMINATION TRANSFORMER LP: RC: FC: CM: SC: SR: OL: EH: EM: OT: TR: DEFROST HEATER (50W) EVAPORATOR SENSOR - G ROOM SENSOR - P

DOOR FRAME HEATER (9.9W) DOOR FRAME HEATER (4.7W) GREEN EARTH ON OFF FC ROOM SENSOR EVAPORATOR SENSOR Y COLOR LEGEND P ESF CONDENSATE DRAIN PAN HEATER (80W) PCB CONTROL POWER SWITCH B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY LP PZBUC0H0K (CAREL PCB CONTROL) LIGHT LAMP REFRIGERATOR COMPRESSOR FREEZER COMPRESSOR CONDENSER FAN MOTOR START CAPACITOR RELAY OVERLOAD ELECTRIC HEATER EVAPORATOR FAN MOTOR OVERHEAT TERMINATION TRANSFORMER LP: RC: FC: CM: SC: SR: OL: EH: EM: OT: TR: EVAPORATOR DRAIN PAN HEATER (80W) EM EM OT CM OL SR SC DEFROST HEATER EVAPORATOR FAN MOTOR DOOR LIGHT SWITCH DEFROST HEATER (400W) EVAPORATOR SENSOR - G ROOM SENSOR - P

S T S R R C LP EM CM 4 4 5 5 0 ESR, ESWR, ESRD, ESRD4 DOOR FRAME HEATER (.5W) DOOR FRAME HEATER (.5W) CONDENSATE DRAIN PAN HEATER (80W) DOOR FRAME HEATER (.4W) GREEN ON EARTH OFF PZBUC0H0K (CAREL PCB ONTROL) B 9 8 7 6 4 0 9 8 7 6 N L 5 4 COLOR LEGEND EVAPORATOR DRAIN PAN HEATER (80W) EVAPORATOR SENSOR ROOM SENSOR DEFROST HEATER EVAPORATOR FAN MOTOR B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY LIGHT LAMP REFRIGERATOR COMPRESSOR FREEZER COMPRESSOR CONDENSER FAN MOTOR START CAPACITOR RELAY OVERLOAD ELECTRIC HEATER EVAPORATOR FAN MOTOR OVERHEAT TERMINATION TRANSFORMER LP: RC: FC: CM: SC: SR: OL: EH: EM: OT: TR: PCB CONTROL POWER SWITCH RC SC 4 4 5 5 DOOR / LIGHT SWITCH EM 6 6 7 7 6 6 OL OT 8 8 9 9 0 0 7 7 8 8 9 9 0 0 4 4 5 5 DEFROST HEATER (400W) EVAPORATOR SENSOR - G ROOM SENSOR - P

DOOR FRAME HEATER (.5W) CONDENSATE DRAIN PAN HEATER (80W) EM EM FC CM OL OT GREEN PCB CONTROL POWER SWITCH DOOR FRAME HEATER (.4W) EARTH ON OFF EVAPORATOR DRAIN PAN HEATER (80W) W BL BL W DEFROST HEATER (400W) PZBUC0H0K CAREL PCB CONTROL DELAY TIMMER ESF, ESWF EVAPORATOR FAN MOTOR DEFROST HEATER FC ROOM SENSOR EVAPORATOR SENSOR LEGEND LIGHT LAMP REF COMPRESSOR FREEZER COMPRESSOR CONDENSER FAN MOTOR START CAPACITOR RELAY OVERLOAD ELECTRIC HEATER EVAPORATOR FAN MOTOR OVERHEAT TERMINATION TRANSFORMER LP: RC: EVAPORATOR DRAIN PAN HEATER (80W) DOOR / LIGHT SWITCH POWER RELAY FC: CM: SC: SR: OL: H: EM: EM EM OT CM OL OT: TR: COLOR DEFROST HEATER (400W) B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY EVAPORATOR SENSOR - R ROOM SENSOR - B CONDENSATE DRAIN PAN HEATER (80W) DOOR FRAME HEATER (.4W) DOOR FRAME HEATER (.5W)

ESRF, ESWRF, ESRF DEFROST HEATER (400W) EVAPORATOR SENSOR - G ROOM SENSOR - P DEFROST HEATER (400W) EVAPORATOR SENSOR - R ROOM SENSOR - B LIGHT / DOOR SWITCH DOOR FRME HEATER (.4W) DOOR FRAME HEATER (.5W) CONDENSATE DRAIN PAN HEATER (80W) LP EVAPORAOTR DRAIN PAN HEATER (80W) EVAPORAOTR DRAIN PAN HEATER (80W) LP DOOR FRAME HEATER (.5W) LIGHT / DOOR SWITCH CONDENSATE DRAIN PAN HEATER (80W) ON OFF LEGEND LP: LIGHT LAMP RC: REF COMPRESSOR FC: FREEZER COMPRESSOR CM: CONDENSER FAN MOTOR SC: START CAPACITOR SR: RELAY OL: OVERLOAD H: ELECTRIC HEATER EM: EVAPORATOR FAN MOTOR OT: OVERHEAT TERMINATION TR: TRANSFORMER GREEN EARTH ON OFF PCB CONTROL POWER SWITCH RC EVAPORATOR FAN MOTOR ROOM SENSOR PZBUC0HK (CAREL PCB CONTROL) PCB CONTROL POWER SWITCH FC PZBUC0HK (CAREL PCB CONTROL) COLOR B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY DEFROST HEATER EVAPORATOR SENSOR EVAPORATOR FAN MOTOR ROOM SENSOR DEFROST HEATER EVAPORATOR SENSOR

alarm buzzer and LED alarm description code alarm relay EO active ON probe error= control E not active ON probe error= defrost LO active ON low temperature alarm HI active ON high temperature alarm EE not active ON unit parameter error df not active OFF defrost running Name Description Type " A " Type " B " Def Vis. Def Vis. Pw Password F F / / Probe measurement stability 5 C 5 C /4 /4 Select probe display C C /5 /5 Select u.d.m. probe C / F C C /6 /6 Disable decimal point C C /C /C Probe offset 0 F 0 F /C /C Probe offset 0 F 0 F /C /C Probe offset 0 C 0 C St Set point S -4 S rd rd Control differential F F

r r Minimum set point value C C r r Maximum set point value C C r r Select derect / reverse operation 0 C 0 C r4 r4 Night-time set point delta C C c0 c0 Compressor and fan start delay on power-up C C c c Minimum time between consecutive compressor starts 0 C 0 C c c Minimum compressor off time 0 C 0 C c c Minimum compressor on time 0 C 0 C c4 c4 Duty setting 0 C 0 C cc cc Continuous cycle duration 4 C 4 C c6 c6 Temperature alarm bypass after continuous cycle C C d0 d0 Type of Dfrost C C di di Interval between defrost 6 F 6 F dt dt End defrost temperature set point C C dp dp Maximum defrost duration ALARM ED 0 F 0 F d4 d4 Defrost when switching the instrument on 0 C 0 C d5 d5 Defrost delay on power-up 0 C 0 C d6 d6 Freeze control temperature display during defrost 0 C 0 C dd dd Dripping time C C d8 d8 Alarm bypass time after defrost C C d9 d9 Defrost priority over compressor protectors 0 C 0 C d/ d/ Defrost probe reading - F - F dc dc time base 0 C 0 C A0 A0 Alarm and fan temperature differential 0 C 0 C AL AL Absolute/relative temperature for low temp. alarm -50 C -50 C AH AH Absolute/relative temperature for high temp. alarm 50 C 50 C Ad Ad Temperature alarm delay 0 C 0 C A4 A4 rd input configuration 0 C 0 C A7 A7 Digital input alarm delay 0 C 0 C A8 A8 Enable alarm ED(end defrost by timeout) 0 C 0 C Ac Ac Set point dirty condenser alarm 70 C 70 C AE AE Dirty condenser alarm differential temperature 5 C 5 C Acd Acd Dirty condensor alarm delay 0 C 0 C F0 F0 Enable evaporator fan control 0 C 0 C F F Evaporator fan control set point 5 C 5 C F F Stop evaporator fan if compressor off 0 C 0 C F F Evaporator fan status during defrost C C Fd Fd Post-dropping time C 5 C H0 H0 Serial address C C H H AUX output configuration 0 C 0 C H H Enable keypad C C H5 H5 Detect changed parameters C C EZY Rapid parameter set selection 0 C 0 C

6 0 8 9 7 4 5 PZBUC0H0K 0 Def.T. Amb.T. 8 9 N 7 6 L 4 5 Comp Def ON OFF Fan B EARTH

Condensing Unit Connector S S T SC R R C OT Condensing Unit Connector DEFROST HEATER (400W) EVAPORATOR SENSOR - G ROOM SENSOR - P 6 7 0 4 5 8 9 4 5 LEGEND LP: LIGHT LAMP RC: REFRIGERATOR COMPRESSOR FC: FREEZER COMPRESSOR CM: CONDENSER FAN MOTOR SC: START CAPACITOR SR: RELAY OL: OVERLOAD EH: ELECTRIC HEATER EM: EVAPORATOR FAN MOTOR OT: OVERHEAT TERMINATION TR: TRANSFORMER COLOR B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK O: ORANGE Y: YELLOW R: RED G: GRAY Wiring Diagram (Model: ESR)

Overload protector Start Capacitor Relay Components Cover Overload Relay Fig 8-8- (Comp Model: FFI Compressor) Fig 8-8- (Comp Model: NE4GK) Service Connector Discharge Connector Suction Connector Compressor Mounting Bolt Vacuum Breaker Suction Tube Discharge Tube Fig 8-9

Table 8-

Table 8-

Table 8-4

S S R R C OL T SC B CM: Condensing Motor SR: Relay SC: Start Capacitor OL: Overload FC: Freezer Compressor BR: Brown B: Blue Pic 8- Fig 8-0 Fig 8- Fig 8-

EH: ELECTRIC HEATER EM: EVAPORATOR FAN MOTOR OT: OVERHEAT TERMINATION EH B: BLUE P: PURPLE W: WHITE BR: BROWN BL: BLACK G: GRAY

6 7 EH EVAPORATOR SENSOR - G ROOM SENSOR - G 8 9 0 4 5 EH: ELECTRIC HEATER P: PURPLE W: WHITE BR: BROWN BL: BLACK G: GRAY

EH EVAPORATOR SENSOR - G ROOM SENSOR - G 6 7 8 9 0 4 5 EH: ELECTRIC HEATER P: PURPLE W: WHITE BR: BROWN BL: BLACK G: GRAY

Door / Light Switch LP: LIGHT LAMP BR: BROWN BL: BLACK Wiring Diagram (Model: ESR)

A Door / Light Switch LP: LIGHT LAMP BR: BROWN BL: BLACK Wiring Diagram (Model: ESR)

6 0 7 8 9 4 5 6 0 8 9 7 4 5 Evaporator Drain Pan Heater Connector BL: BR: BLACK BROWN LP: EH: LIGHT LAMP ELECTRIC HEATER EH EH EH EH EH EVAPORATOR DRAIN PAN HEATER (80W)

A B

4 5 6 7 8 9 0

4

Symptom PossibleCause Corrective Action