NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

Similar documents
In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

In Situ Temperature Measurement

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Technical-Report for SL Lamp 5 W

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Phillips-Lumileds LEDs Flip Chip Technology Warehouse lighting, Factory lighting, Showroom & Convention centre lighting. 60,000 Hours at L70

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LED Panel Light E830J

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

FPLHB - Fidelux Premier Linear Highbay

2018 Instant Lighting Rebates Product Catalog

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

LED Linear Design Highlights

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Designed by TD lighting Solutions in Turkey, Powered by Nichia LEDs from Japan

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

2018 Midstream Lighting Product Catalog

Acacia Batten. Contents. Willow Range 3 YE AR. Single. Twin. Single

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Recessed and surface mounted LED downlight family

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

60W 120W 300W INTEGRAL WITHIN THE FIXTURE HOUSING 120V - 277V 60W = 59.6 W 120W = W 300W = W

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

ADVANCED HIGH CEILING Tetriss Series

HEP Tech Co., Ltd. Company Profile

SECTION INTERIOR LIGHTING

Lamp Circuit Power Test Report

Kasia lighting and design AOK. Series New LED Parking Lot & Area Light.

Eligible Prescriptive Measures List:

Product Compliance Andy Guest

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Urbanlite. We light your world IK08 IP

LED HIGH BAY LINEAR ECO SERIES

CONTENTS. Draft Minimum Energy Performance Standards for LED Lighting V6 14 November

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Surface Mount Series Luminaires

2013 Catalog. RoHS Western Way, Suite 155 Jacksonville, FL

Fire resistance test on fire collars protecting a concrete slab penetrated by services

LED SLIM DISKS PK613LED FIXED 3-LIGHT ROUND

Technical Application Guide for UP-SHINE LED Spotlight

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Housing. Mounting EPA. Warranty. Listing

2013 Catalog. RoHS Western Way, Suite 155 Jacksonville, FL

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

LED Fire Rated Downlight

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

PLUG & PLAY LED GARDEN LIGHTING RANGE 2017

SDG&E s Business Energy Solutions Program 2018 Product Catalog

Technical application guide

OLUX LED IN-GROUND OSRAM. Datasheet

The Commercial LED Lighting Specialist

Energy Efficient Lighting Systems

A low energy alternative to halogen which provide energy savings of around 90%

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

Mark 25 Ultrapure Water Conductivity Analyzer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

DHL-LP-LED Low Profile LED Linear High/Low Bay

Technical Application Guide for UP-SHINE LED Panel Light

Technical application guide

Claude Indirect Wall WALL

Refrigerating Appliance ErP Test Report

LHBXD LED Linear High Bay

Philips MASTER LEDbulb ClearClassic MV DimTone

Reflector T2 and GU10 6,000 hours

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

PRODUCT COLLECTION

Fortimo LED Line High Flux Module

Transcription:

In Situ Temperature Measurement Test Report For Shen Zhen Green Works Lighting Co., Ltd (Brand Name: Green Works Lighting) Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China. High-bay Luminaires for Commercial and Industrial Buildings Model name(s): GL-LHB-150W Representative (Tested) Model: GL-LHB-150W(5000K) GL-LHB-150W(5700K) Test & Report By: Charman Chen Engineer: Charman Chen Date: Dec.26,2016 Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 9

Table of Contents 1 General... 3 1.1 Product Information... 3 1.2 Standards or methods... 4 1.3 Equipment list... 4 2 Test conducted and method... 4 2.1 Ambient Condition... 4 2.2 Temperature Stabilization... 5 2.3 Thermocouples... 5 2.4 Thermocouples contact... 5 3 Test Results... 6 3.1 Data:... 6 3.2 Test Photo:... 6 2 / 9

1 General 1.1 Product Information Brand Name Green Works Lighting Model Number GL-LHB-150W Luminaire Type High-bay Luminaires for Commercial and Industrial Buildings Nominal Power 150W Rated Initial Lamp Lumen -- Declared CCT 5000K,5700K LED Manufacturer Nichia Corporation LED Model NF2x757xR Sample Receipt Date Dec.22,2016 Sample Number GZE161037-G1(5000K),G2(5700K) Photo 3 / 9

1.2 Standards or methods The following standards are partly or totally used or referenced for test: No. ANSI/UL 1598:2008 Luminaires Name 1.3 Equipment list Equipment ID Equipment Name Last Calibration Date Next Calibration Date PF210 Power Meter 2016-07-01 2017-06-30 ST-R-181A Temperature Tester 2016-07-01 2017-06-30 2 Test conducted and method 2.1 Ambient Condition Test was conducted in an ambient temperature of 25+5. Ambient temperature variations above or below 25 was subtracted from or added to temperatures recorded at points on the luminaire. The ambient temperature was measured by a thermocouple which was immersed in 15ml of mineral oil in a glass container. 4 / 9

2.2 Temperature Stabilization Temperatures were measured after they have stabilized when the test has been running for a minimum of 7.5 hours, or the test has been running for a minimum of 3 hours and three successive reading taken at 15 minutes intervals are with 1 of another and are not rising. 2.3 Thermocouples Type J thermocouple was used for temperature measurement. The thermocouple was 0.05mm2(30AWG), and complied with the requirements specified in ASTM MNL 12 and limits of error specified in NIST ITS 90 and ISA MC96.1. 2.4 Thermocouples contact Thermocouples were in contact with the TMP LED location described in LM-80 test report. In order to gain the maximum temperature, if appropriate, more than one thermocouple were contact in these locations. For details information, please refer to clause 3.3 for the photo of thermocouple contact. 5 / 9

3 Test Results Test date 2016-12-23 Test Ambient 25.1 C Sample No. LED Package Model GZE161037-G1 NF2L757DR LED driver of Each Lamp Output voltage V Measured LED working current (Max.) ma 1 42.5 141.9 3.1 Test Data: Input Vol. 120.0V Input Current 1.240A Input Wattage 147.6W Temperature stabilization time: 500 min No. Temperature ( C) No. Temperature ( C) No. Temperature ( C) Measured Corrected Corrected Corrected Measured Measured at 25 C at 25 C at 25 C 1 62.9 62.8 3 60.4 60.3 5 60.9 60.8 2 61.4 61.3 4 62.4 62.3 6 63.7 63.6 The highest in-situ measured temperature LED is 63.6 C 3.2 Test Photo: Ts Position: 6 / 9

Thermocouple Location on Temperature Measurement Point (TMP): 7 / 9

3.3 Test Data of LED Driver: Temperature Input Vol. 120.0V Input Current 1.240A Input Wattage 147.6W 500 min stabilization time: Measured TC Temperature ( C) Temperature Limited of Life 50000 hours No Measured Corrected at 25 C 1 65.8 65.7 75 3.4 Test Photo: Thermocouple Location on Temperature Measurement Point (TMP): 8 / 9