Product Specification CAT 6 UNSHIELDED PATCH CORDS

Similar documents
Cat 6 Unshielded Patch cords

/Oct/2014 Rev E

Cat 6 Shielded Patch cords

/Oct/2014 Rev B

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Qualification Test Report 1/Jul/2005 Rev. A

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Mar11 Rev B

Jan05 Rev A EC

Jun08 Rev A

Two Circuit Heavy Duty Burner Connector

/Mar/2014 Rev A

Mar11 Rev C

Jun08 Rev C

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

CATEGORY 6A FTP RJ45 SOLUTION

Jul07 Rev C

Multi-Core Fire Resistant Cable

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

HMN-D2 Insert Series

Qualification Test Report LC Duplex Adapter For LC Cutouts

INTERNATIONAL STANDARD

FEB. 17 Rev. A1

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

DNVGL-CP-0402 Edition February 2016

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Apr06 Rev A

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

APR 17 Rev A

Catalogue Telecommunication Cables INTRODUCCIÓN

Lloyd s Register Type Approval System Test Specification Number 3

Jan07 Rev B

This document is a preview generated by EVS

High Performance LSZH Fire Resistant Cable

JUL 18 Rev A1

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

DNVGL-CP-0401 Edition February 2016

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

USB 3.0 Plug & Receptacle

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Compact Module. Category 6A FTP Cabling System 1.1

ETSI TS V1.2.1 ( )

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Telecommunication Cables

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

HELKAMA. Optical Fibre Cables

Product Specification Qualification Test Report

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

SolderSleeve Insulated Electrical Termination Devices

ETSI TS V1.2.1 ( )

DNVGL-CP-0399 Edition March 2016

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Draft ES V1.1.1 ( )

Caledonian Flame Retardant Coaxial Cables

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Fiber Optic Distribution Cables (6-144 Fibers)

INTERNATIONAL STANDARD

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

This document is a preview generated by EVS

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

LSOH Flexible Cables

Rules for Classification and Construction Additional Rules and Guidelines

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

TYPE APPROVAL CERTIFICATE

ISO/TS TECHNICAL SPECIFICATION

FIRE RESISTANT CABLES

TE Connectivity's AMP NETCONNECT Cable Management

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Nuclear Power Plant LSZH Cable Overview

The Next Generation of Data Communicatons Solutions

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

PRODUCT CATALOGUE Norröna

Total Fire Solutions. Includes BS 8519 and the updated BS :

MT-RJ Optical Fiber System Field Testing

SAS Security and Alarm Safety Cables

This document is a preview generated by EVS

INTERNATIONAL STANDARD

Traction Cable Radox 3 GKW

SECTION AUTOMATIC TRANSFER SWITCHES

Transcription:

Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT Cat 6 unshielded patch cord assemblies used to connect building wiring for data and voice networking systems. 1.2 Qualification When tests are performed on subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using applicable inspection plan and product drawing. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the product drawing or any Tyco Electronics (TE) documents listed below, the product drawing and TE documents shall take precedence. In the event of conflict between the requirements of this specification and the industrial standards, this specification shall take precedence. 2.1 Tyco Electronics Documents A. Relevant customer drawing B. 230-702: Design for environment standard Supplier Requirements for the Elimination of Hazardous Substances C. 108-93018: Product Specification - Copper LAN cable 2.2 Industrial Standards: A. ISO / IEC 11801: Generic Cabling for Customer Premises B. EN 50173: Information Technology; Generic Cabling Systems C. ANSI/TIA/EIA 568-B.2-1: Commercial Building Telecommunications Cabling Standard D. IEC 61935-2: Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801. Patch cords and work area cords. Test Specifications as indicated in Fig. 1. E. IEC 60512-4-1: Electromechanical Components for Electronic Equipment; Basic Testing procedures and measuring methods. Test 4a: Voltage Proof. F. IEC 60603-7-4 Connectors for electronic equipment. Detail specification for 8-way, unshielded, free & fixed connectors, for data transmission with frequencies up to 250 MHz. G. IEC 60603-7-5 Connectors for electronic equipment. Detail specification for 8-way, shielded, free & fixed connectors, for data transmission with frequencies up to 250 MHz. DR DATE APVD M. Maqueda**/J. Gatnau** 23/Nov/06 J.Sanabra** Rev. A, Issued Tyco Electronics AMP España S.A, Barcelona, Spain This specification is a controlled doc. 1 of 6 Copyright 2000 * Trademark DATE 23/Nov/06 All rights reserved ** Signatures on File I Indicates change INGF-028

H. IEC 60332-1-2 Tests on electrical and optical fibre under fire conditions. I. IEC 60754-1 Test on gases evolved during combustion of materials from cables. Determination of the amount of halogen acid gas. J. IEC 60754-2 Test on gases evolved during combustion of materials from cables. Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables. K. IEC 61034-2 Measurement of smoke density of cables burning under defined conditions. 3. REQUIREMENTS 3.1 Design and Construction Product shall be of design, construction and physical dimensions specified on applicable customer drawing. 3.2 Materials Materials shall be in accordance to Tyco Electronics requirements about environmental-related substances as per Tyco Electronics specification 230-702. The material of the cable jacket is identified on the customer drawing and shall comply with the standards mentioned in underneath table (extracted from Product Specification 108-93018 Copper LAN cable ): Jacket material Fire rating Toxicity Acid gas Smoke density PVC IEC 60332-1-2 - - - LSZH IEC 60332-1-2 IEC 60754-1 IEC 60754-2 IEC 61034-2 3.3 Ratings Operating Temperature: -20 to 60ºC 3.4 Packaging Each assembly shall be supplied in a clear bag. 3.5 Bending radius The minimum bending radius is 8x outside diameter during installation and 4x the outside diameter after installation. 3.6 Performance Requirements and Test Procedures Product is designed to meet electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions. Rev. A 2 of 6

Test Description Requirement Test Procedure VISUAL Examination of Meets requirements of product drawing. Visual inspection criteria as defined in IEC product. 61935-2, Paragraph 5.1. ELECTRICAL Wire map Continuity and short circuit Any device which ensures quality Wire map configuration according to product drawing AMPTRAC Continuity and short circuit (between pogo Any device which ensures quality. connection (ninth pin and plug shield) (See figure 2 as information) conductor) (only applicable for AMPTRAC versions) Voltage proof 1 minute hold with no breakdown or IEC 60512-4-1 (only applicable for flashover 1500 volts AC peak voltage to be applied AMPTRAC versions) between pogo pin and plug shield. Maximum leakage current 5 ma TRANSMISSION (See Figure 3 for transmission tests in Channel set up) Return Loss Class E Channel Return Loss IEC 61935-1, Paragraph 4.9 requirements Insertion Loss Class E Channel Insertion Loss IEC 61935-1, Paragraph 4.1 requirements NEXT Loss Class E Channel NEXT requirements IEC 61935-1, Paragraph 4.6 PS NEXT Loss Class E Channel PS NEXT requirements (PS NEXT is computed from NEXT Loss values) ACR Class E Channel ACR requirements (ACR is computed from NEXT and Insertion Loss values) PS ACR Class E Channel PS ACR requirements (PS ACR is computed from ACR values) FEXT Loss (There are no requirements for FEXT IEC 61935-1, Paragraph 4.7 Loss) ELFEXT Class E Channel ELFEXT requirements (ELFEXT is computed from FEXT and Insertion Loss values) PS ELFEXT Class E Channel PSELFEXT requirements (PS ELFEXT is computed from ELFEXT values) Propagation delay Class E Channel Prop Delay requirements IEC 61935-1, Paragraph 4.5 Delay Skew Class E Channel Delay Skew requirements IEC 61935-1, Paragraph 4.5 MECHANICAL Crimping Height Relevant IEC 60603-7-X standard Indicator with needle-point probes or equivalent. It shall be measured at the front of the contact. Tensile Strength Torsion Force (specified by Tyco Electronics) Force applied: 50 N according to the standard Duration: 5 seconds Force applied: 10 N x cm Duration: 5 seconds Maximum Rotation angle 45º IEC 61935-2, Paragraph 6.2. (See figure 4 as information) (See figure 5 as information) NOTE See Test Sequence in paragraph 4.2 Figure 6 Figure 1: Requirements and test procedures for Cat 6 unshielded patch cords Rev. A 3 of 6

Figure 2: AMPTRAC connection continuity and shortcircuit test procedure Figure 3: Channel set up Figure 4: Tensile strength test procedure Figure 5: Torsion force test procedure 4. PRODUCT QUALIFICATION AND REQUALIFICATION TEST SEQUENCE 4.1 Sample Selection Samples shall be selected at random from current production. For qualification purpose, all test groups shall consist of a minimum of 5 samples per relevant length per product family. Rev. A 4 of 6

4.2 Test sequence Test Sequence Standard version AMPTRAC version Examination of product 1, 17 1, 19 Wire Map 3 3 AMPTRAC connection: Continuity and shortcircuit - 4, 20 (only for AMPTRAC versions) Voltage Proof (only for AMPTRAC versions) - 5, 21 Return Loss 4, 18 6, 22 Insertion Loss 5, 19 7, 23 NEXT 6, 20 8, 24 PS NEXT Loss 7, 21 9, 25 ACR 8, 22 10, 26 PS ACR 9, 23 11, 27 FEXT 10, 24 12,28 ELFEXT 11, 25 13, 29 PS ELFEXT 12, 26 14, 30 Propagation Delay 13, 27 15, 31 Delay Skew 14, 28 16, 32 Crimping Height 2 2 Tensile Strength 15 17 Torsion Force 16 18 4.1 Requalification Testing Figure 6: Test sequence If changes significantly affecting form, fit or function are made to the product or manufacturing process, requalification testing shall be initiated, consisting of all or part of the original testing sequence as determined by Tyco Electronics. 5. QUALITY ASSURANCE PROVISIONS Quality provisions are based upon the philosophy of TQM (Total Quality Management) with a system approved to EN ISO 9001 by Lloyds Register Quality Assurance. 5.1 Responsibility for quality Unless otherwise stated in the purchase order, it shall be the supplier's responsibility to assure qualification and lot conformance to this specification. The supplier may utilize his own or other testing and inspection facilities acceptable to the buyer. 5.2 Qualification conformance For the purposes of internal qualification, the program shall consist of examinations and tests to determine conformance with the requirements of this specification. It shall be performed once, on introduction of the product. Subsequent design changes shall be partially or fully re-qualified depending upon their area of impact in the context of product functionality. Regular requalification testing shall be performed as defined by the Quality Department. Rev. A 5 of 6

5.3 Manufacturing follow-up Tyco Electronics products target Six Sigma levels of performance by the integration of capable processes from the development throughout the entire supply chain. The goal is to reduce variability to achieve zero defects for products and services. Systems used are based on preventive and statistical techniques during development and manufacturing. This also includes suppliers of materials, components or systems. Dedicated procedures for supplier selection, development and follow-up are implemented to ensure conformance to TQM and specification requirements. Best demonstrated practices are identified and implemented throughout the company, with a continuing challenge to identify opportunities for innovation and improvement. Rev. A 6 of 6