Cat 6 Unshielded Patch cords

Similar documents
/Oct/2014 Rev E

Cat 6 Shielded Patch cords

/Oct/2014 Rev B

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report 1/Jul/2005 Rev. A

Mar11 Rev B

Jan05 Rev A EC

Jun08 Rev A

Two Circuit Heavy Duty Burner Connector

Jun08 Rev C

Mar11 Rev C

FEB. 17 Rev. A1

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Jul07 Rev C

HMN-D2 Insert Series

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

INTERNATIONAL STANDARD

/Mar/2014 Rev A

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Qualification Test Report LC Duplex Adapter For LC Cutouts

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Apr06 Rev A

INTERNATIONAL STANDARD

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Jan07 Rev B

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

APR 17 Rev A

CATEGORY 6A FTP RJ45 SOLUTION

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

USB 3.0 Plug & Receptacle

INTERNATIONAL STANDARD

This document is a preview generated by EVS

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

INTERNATIONAL STANDARD

Multi-Core Fire Resistant Cable

TE Connectivity's AMP NETCONNECT Cable Management

SolderSleeve Insulated Electrical Termination Devices

Fiber Optic Distribution Cables (6-144 Fibers)

JUL 18 Rev A1

INTERNATIONAL STANDARD

This document is a preview generated by EVS

INTERNATIONAL STANDARD

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ETSI TS V1.2.1 ( )

commercial-type cabling and connectivity products into the industrial landscape.

INTERNATIONAL STANDARD

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Product Specification Qualification Test Report

This document is a preview generated by EVS

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

5. Identification products.

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Rules for Classification and Construction Additional Rules and Guidelines

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

ETSI TS V1.2.1 ( )

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Compact Module. Category 6A FTP Cabling System 1.1

ITU-T L.404. Field mountable single-mode optical fibre connectors

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

4120 Fire Alarm Network Reference

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Universal Retention Modules 02 MAR 10 Rev A

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Snifter. User Manual. Distributor

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

SECTION AUTOMATIC TRANSFER SWITCHES

Application Specification MAG-MATE* Poke-In Tab Terminals

This document is a preview generated by EVS

TYPE APPROVAL CERTIFICATE

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

MT-RJ Optical Fiber System Field Testing

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Model T B Intraoffice T1 Repeater User Manual

Draft ES V1.1.1 ( )

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Application Tooling Specification Sheet

Duct Cable GYTS-144B1.3

Connecting and Routing the Cables

INTERNATIONAL STANDARD

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Total Fire Solutions. Includes BS 8519 and the updated BS :

Transcription:

Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat 6 unshielded patch cord assemblies used to connect building wiring for data and voice networking systems. 1.2 Qualification When tests are performed on subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using applicable inspection plan and product drawing. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the customer drawing or any Tyco Electronics (TE) documents listed below, the customer drawing and TE documents shall take precedence. In the event of conflict between the requirements of this specification and the industrial standards, this specification shall take precedence. 2.1 Tyco Electronics Documents A. Relevant customer drawing B. 230-702: Design for environment standard Supplier Requirements for the Elimination of Hazardous Substances C. 108-93018: Product Specification - Copper LAN cable 2.2 Industrial Standards: A. ISO / IEC 11801 : Generic Cabling for Customer Premises B. EN 50173-1: Information Technology; Generic Cabling Systems C. ANSI/TIA/EIA 568-B.2-1: Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted Pair cabling Components Addendum 1: Transmission Performance Specifications for 4-Pair 100Ohm Category 6 Cabling. D. IEC 61935-1: Generic cabling systems - Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801. Part 1: Installed cabling. E. IEC 61935-2: Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801. s and work area cords. Test Specifications as indicated in Fig. 1. F. IEC 61156-6: Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up to 1000MHz Work area wiring Sectional specification. G. IEC 60603-7-4 Connectors for electronic equipment. Detail specification for 8-way, unshielded, free & fixed connectors, for data transmission with frequencies up to 250 MHz. 2009 Tyco Electronics AMP España, S.A., Barcelona (Spain) All International Rights Reserved * Trademark Indicates changes 1 of 7 LOC IK

H. IEC 60512-4-1: Electromechanical Components for Electronic Equipment; Basic Testing procedures and measuring methods. Test 4a: Voltage Proof. 3. REQUIREMENTS 3.1 Design and Construction Product shall be of design, construction and physical dimensions specified on applicable customer drawing. 3.2 Standard length Applicable standard lengths: from 0.5meter to 20meter (both included). For other lengths, put in contact with your sales representative. 3.3 Materials Materials shall be in accordance to Tyco Electronics requirements about environmental-related substances as per Tyco Electronics specification 230-702. The material of the cable jacket is identified on the customer drawing and shall comply with the standards mentioned in Product Specification 108-93018 Copper LAN cable. 3.4 Ratings Operating Temperature: -20 to 60ºC 3.5 Packaging Each assembly shall be supplied in a clear bag. 3.6 Bending radius The minimum bending radius is 8x outside diameter during installation and 4x the outside diameter after installation. 3.7 Performance requirements and test procedures Product is designed to meet electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions. Rev D 2 of 7

Test Description Requirement Test Procedure VISUAL Examination product. Wire map of AMPTRAC connection (9 th wire) (only applicable for AMPTRAC versions) Voltage proof (only applicable for AMPTRAC versions) Meets requirements of product drawing. ELECTRICAL Continuity and short circuit Wire map configuration as per TIA 568B Continuity and short circuit (between pogo pin and plug shield) 1 minute hold with no breakdown or flashover Visual inspection criteria as defined in IEC 61935-2, Paragraph 5.1. Any device which ensures quality Any device which ensures quality. (See figure 2 as information) IEC 60512-4-1 1500 volts AC peak voltage to be applied between pogo pin and plug shield. Maximum leakage current 5 ma TRANSMISSION (See Figure 3 for transmission tests in Channel set up) Return Loss Class E Channel Return Loss IEC 61935-1, Paragraph 4.11 Insertion Loss Class E Channel Insertion Loss IEC 61935-1, Paragraph 4.5 NEXT Loss Class E Channel NEXT requirements IEC 61935-1, Paragraph 4.7 PS NEXT Loss Class E Channel PS NEXT requirements (PS NEXT is computed from NEXT Loss values) ACR-N Class E Channel ACR-N requirements IEC 61935-1, Paragraph 4.8 PS ACR-N Class E Channel PS ACR-N requirements (PS ACR-N is computed from ACR-N values) FEXT Loss (There are no requirements for FEXT IEC 61935-1, Paragraph 4.9 Loss) ACR-F Class E Channel ACR-F requirements IEC 61935-1, Paragraph 4.10 PS ACR-F Class E Channel PS ACR-F requirements (PS ACR-F is computed from ACR-F values) Propagation delay Class E Channel Prop Delay IEC 61935-1, Paragraph 4.6 Delay Skew Class E Channel Delay Skew IEC 61935-1, Paragraph 4.6 MECHANICAL Crimping Height Relevant IEC 60603-7-X standard Indicator with needle-point probes or equivalent. It shall be measured at the front of the contact. Tensile Strength Force applied: 50 N according to the IEC 61935-2, Paragraph 6.2. standard. Duration: 5 seconds (See figure 4 as information) Torsion Force Force applied: 10 N x cm (See figure 5 as information) (specified by Tyco Duration: 5 seconds Electronics) Maximum Rotation angle 45º NOTE See Test Sequence in paragraph 4.2 Figure 6 Figure 1: Requirements and test procedures for Cat 6 unshielded patch cords Rev D 3 of 7

Figure 2: AMPTRAC connection continuity and short-circuit test procedure under test Class E Perm Link Permanent Reference Channel configuration Figure 3: Test set up - Channel configuration Figure 4: Tensile strength test procedure Test based on 1 rotation x 1 side Maximum rotation angle 45º Maximum distance between shield and cable clamp 5mm Figure 5: Torsion force test procedure Torque value to be applied between shield and cable jacket 10 N cm Rev D 4 of 7

NOTE In general, patch cords are components of a Channel cabling configuration. Channels are length limited by standards in order to achieve specific requirements, for this reason all component lengths have to be considered for obtaining the expected cabling performance. In case of a Class E Channel 2-connector model: 2-conn Channel model Permanent Link Maximum patch cords total length allowed is obtained by the following equation: ( Max_ Length [ m] RatioA) = [ m] Length [ m] Patch_ cords 104 ( RatioB) Permanent_ Link Where RatioA and RatioB are the cable insertion loss ratios which depend on cable type (solid or stranded). In general, they take the following values: For stranded cables, Ratio _ stranded =1. 5 For solid cables, Ratio _ solid =1. 0 4. PRODUCT QUALIFICATION AND REQUALIFICATION 4.1 Sample Selection Samples shall be selected at random from current production. For qualification purpose, all test groups shall consist of a minimum of 5 samples per relevant length per product family. Rev D 5 of 7

4.2 Test sequence Test Sequence Standard version AMPTRAC version Examination of product 1, 17 1, 19 Wire Map 3 3 AMPTRAC connection: Continuity and shortcircuit - 4, 20 (only for AMPTRAC versions) Voltage Proof (only for AMPTRAC versions) - 5, 21 Return Loss 4, 18 6, 22 Insertion Loss 5, 19 7, 23 NEXT 6, 20 8, 24 PS NEXT Loss 7, 21 9, 25 ACR-N 8, 22 10, 26 PS ACR-N 9, 23 11, 27 FEXT 10, 24 12,28 ACR-F 11, 25 13, 29 PS ACR-F 12, 26 14, 30 Propagation Delay 13, 27 15, 31 Delay Skew 14, 28 16, 32 Crimping Height 2 2 Tensile Strength 15 17 Torsion Force 16 18 Figure 6: Test sequence 4.3 Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, requalification testing shall be initiated, consisting of all or part of the original testing sequence as determined by Tyco Electronics. 5. QUALITY ASSURANCE PROVISIONS Quality provisions are based upon the philosophy of TQM (Total Quality Management) with a system approved to EN ISO 9001 by Lloyds Register Quality Assurance. 5.1 Responsibility for quality Unless otherwise stated in the purchase order, it shall be the supplier's responsibility to assure qualification and lot conformance to this specification. The supplier may utilize his own or other testing and inspection facilities acceptable to the buyer. Rev D 6 of 7

5.2 Qualification conformance For the purposes of internal qualification, the program shall consist of examinations and tests to determine conformance with the requirements of this specification. It shall be performed once, on introduction of the product. Subsequent design changes shall be partially or fully re-qualified depending upon their area of impact in the context of product functionality. Regular requalification testing shall be performed as defined by the Quality Department. 5.3 Manufacturing follow-up Tyco Electronics products target Six Sigma levels of performance by the integration of capable processes from the development throughout the entire supply chain. The goal is to reduce variability to achieve zero defects for products and services. Systems used are based on preventive and statistical techniques during development and manufacturing. This also includes suppliers of materials, components or systems. Dedicated procedures for supplier selection, development and follow-up are implemented to ensure conformance to TQM and specification requirements. Best demonstrated practices are identified and implemented throughout the company, with a continuing challenge to identify opportunities for innovation and improvement. Rev D 7 of 7