HEATING AND COOLING DEVICE AGC

Similar documents
Technical documentation: S1 S2 S3 S4

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Technical documentation

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Series VENTS VUT R WH ЕС

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Technical documentation DTR

TopVent Design Handbook

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

OPERATION AND MAINTENANCE MANUAL COMPACT VENTILATION UNIT WITH HEAT PUMP MCKT-HPX SERVICE

AXIAL FANS USER S MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Centrifugal inline fans

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

OXeN. Ductless ventilation with heat recovery.

HEAT RECOVERY AIR HANDLING UNIT

NKW. Heater series HEATERS

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

CENTRIFUGAL FANS user's manual. model VENTS VK.

HEATING AND COOLING UNITS BRAVA

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Wind. Service instruction

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical documentation DTR. Farmer HCF in EPP casing

Aero. Service Instructions

Turbo. Service Instructions

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

CASSETTE UNIT. Comfort Circle

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Calm. Service Instructions

CENTRIFUGAL CEILING EXTRACT FAN

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

1.1 VTS: number 1 in the world pillars of success

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

USER S MANUAL. VKP Series INLINE FAN

CAW Ceiling-mounted fan heaters for hot water

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

INTELLIGENT AXIAL FAN user's manual

DUCTLESS VENTILATION WITH HEAT RECOVERY. OXeN ductless ventilation unit

TTV 4500 / TTV 4500 HP / TTV 7000

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

OXeN. Ductless ventilation with heat recovery.

HEAT RECOVERY VENTILATOR

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Cassette units Model Comfort Circle. - heating - cooling - ventilation

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

Blower-YEFB-020-3R-1maxVel

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

technical data Fan coil unit FWB small duct unit

OPERATION AND MONTAGE MANUAL ROOF FANS

CENTRIFUGAL CEILING EXTRACT FAN

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

City of Duluth Festival Center 04/25

OPERATION AND MONTAGE MANUAL ROOF FANS

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking:

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Fan heater SWT Ceiling mounted fan heater with water heat

Axial intelligent fan USER S MANUAL

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

INSTALLATION AND OPERATION MANUAL

Air handling unit. BlauAir RH USER S MANUAL

CxA to Answer this Section

Air curtain.

Local Air Conditioner

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

Transcription:

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 1/8 HEATING AND COOLING DEVICE AGC SERVICE phone.: (+48 58) 783 99 50/51 Fax: (+48 58) 783 98 88 mobile: (+48) 510 098 081 E-mail: serwis@klimor.pl GDYNIA, December 2013

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 2/8 Include: page 1. INTRODUCTION... 3 2. TECHNICAL DATA AND APPLICATION... 3 3. CONSTRUCTION OF AGC DEVICE... 5 4. AUTOMATION... 5 5. DELIVERY AND TRANSPORT... 5 6. INSTALLATION... 5 6.1 INSTALLING... 5 6.2 WATER INSTALLATION CONNECTION... 6 6.3 ELECTRICAL INSTALLATION... 6 7. AGB INITIAL START-UP... 7 8. AGB OPERATIONS AND USING... 7 8.1 SWITCHING ON... 7 8.2 SWITCHING OFF... 7 8.3 SERVICE OPERATION... 7 9. SERVICE - INFORMATION... 7 10. SERVICE INITIAL CARD... 8

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 3/8 1. INTRODUCTION The purpose of the DTR [operation and service manual] is to familiarize installers and users with the construction as well as correct servicing and operation of the AGC device. Prior to installing and operating the AGC device, you should read through this Technical and Maintenance Documentation and follow strictly the guidelines and recommendations contained herein. Non-compliance with the guidelines and recommendations contained in the Technical and Maintenance Documentation shall relieve the Manufacturer of guarantee-related liability. In case of any questions concerning transport, installation or operation, please contact KLIMOR sales or design department. KLIMOR reserves the right to implement, without notice, the structural and material modifications resulting from product modernization and improvement. 2. TECHNICAL DATA AND APPLICATION Heating and Cooling device AGC is designed for heating and ventilation of commercial pavilions, workshops, industrial halls, warehouses and other similar objects. AGC works on the circulating air or mixed with fresh air. Heating medium of CuAl heater is hot water. The device is not designed to work in an environment with temperature of air above 45 C and a relative humidity of over 60% or in the environment exposed to risk of explosion of inflammable gases and vapours that contain organic solvents and other aggressive substances. The device is not designed to work in a room with dusty and polluted air. Dust in the air passing through the heater should not exceed 0,3 g/m 3. Zawiesia Slings 332 ~60 600 428 296 332 Top view Widok z góry Fig No 1 AGC device

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 4/8 Tab No 1 Technical data PARAMETERS DATA Air volume 3500 m 3 /h Coil (heater/cooler) Max. heating power for medium 90/70 C Max. cooling power for medium 6/12 C Difference temperature of air with medium 90/70 C 2 rows 57 kw 32 kw Max. medium temperature 110 C Max. medium pressure 1,0 MPa Coil connection R1 Coil capacity 3,0 dm 3 Supply for fan Fan motor power 45K 230V; 50Hz 240 W Fan engine IP 54 Max. air stream range 20 m Noise level (in 5m) Weight (without medium) 53 db(a) 30 kg Tab No 2 Heating and cooling parameters AGC heating - air volume 3500 m 3 /h Tw1/Tw2 [ C] tp1 [ C] tp2 [ C] Q [kw] p [kpa] G [m 3 /h] 0 22,5 28,4 1,8 1,2 5 25,4 24,9 1,5 1,1 60/40 10 27,5 21,4 1,1 1,0 15 29,9 17,8 0,9 0,8 20 32,1 14,3 0,6 0,6 0 28,0 35,5 3,3 1,6 5 30,8 32,0 2,7 1,4 70/50 10 33,3 28,5 2,2 1,3 15 35,8 25,0 1,8 1,1 20 38,2 21,6 1,3 1,0 0 33,7 42,6 5,5 1,9 5 36,4 39,1 3,8 1,7 80/60 10 39,1 35,6 3,2 1,6 15 41,7 32,1 2,7 1,4 20 44,2 28,7 2,2 1,3 0 39,2 49,6 5,8 2,2 5 42,0 46,0 5,1 2,0 90/70 10 44,7 42,5 4,4 1,9 15 47,4 39,0 3,8 1,7 20 49,0 34,4 3,0 1,5 AGC cooling air volume 3500 m 3 /h Tw1/Tw2 [ C] tp1 [ C] tp2 [ C] Q [kw] p [kpa] G [m 3 /h] 40 25,9 27,6 24,7 4,8 5/10 35 22,8 20,1 14,0 3,4 30 20,9 12,4 6,0 2,2 25 17,5 8,8 3,3 1,6 40 27,2 27,4 30,2 4,7 7/12 35 24,4 19,4 16,0 3,3 30 21,7 12,1 6,7 2,1 25 18,6 7,5 2,8 1,3 40 29,2 22,4 11,2 2,8 8/15 35 27,5 12,9 4,10 1,6 30 24,1 8,4 1,9 1,0 25 22,3 3,2 0,3 0,4 Tw1 supply water temperature Tw2 exhaust water temperature tp1 air in temperature tp2 air out temperature Q heater (cooler) power p different water pressure G water volume flow

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 5/8 3. CONSTRUCTION OF AGC DEVICE Casing with slings for mounting the device. Casing made from coated steel RAL 9005 Fan axial, ensuring low noise level due to the shape of the rotor blades used. The fan has a protection grid witch secured an access to the rotating parts. Coil Cu/Al. type equipped with plugs for venting and trigger heating medium. Insulation drip tray with outlet (connection) drain. 4. AUTOMATION Automatic system is optional equipment Complete automation system is: - 2-way control valve with electromotor actuator controls coil work - 2-way control valve R1 (kvs=6,9m 3 /h; temp. medium 2 95 C); electromotor actuator - supply 230V; IP20, - speed control for fan engine for enabling control and indirectly heat output of the heater - supply 230V; 50/60Hz; 5 regulation step; IP54; Imax = 2A, - room thermostat for setting the desired air temperature in the room at 5 30 C; supply 230V; 50/60Hz; IP30; Imax = 16A. 5. DELIVERY AND TRANSPORT The Heating and Cooling Device AGC is supplied in fully assembled. Cardboard packaging protects AGC against mechanical damages at the time of transport and storage. The device is supplied with Operation and Service Manual and Warranty Card. Optional equipment is delivered in a separate package. Immediately after the delivery, be sure to check out the contents of the package. In case of any shortage, you must contact the carrier or supplier of the equipment. 6. INSTALLATION 6.1 Installing During the installation of AGC, attention should be paid to ease of access for service operations, for the right of the water and electricity installation and the appropriate site in the room to keep the right distance from the construction wall and the proper air distribution in the room. In the case of installation under the ceiling, coil may require additional auto-vent installed at the highest point of the pipeline. min. 3m opt. 4-15m Fig No 2 Mounting AGC device Failure to follow the above recommendations may result in not achieving the intended parameters of air flow

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 6/8 6.2 Water installation connection Connect the water installation to the heater should be done in such a way that the possibility of servicing. On both connectors must be mounted shut off valves. The supply and return pipeline must be connected according to the indications on the housing of AGC (inlet/outlet). 2-way control valve with electromotor actuator (optional-equipment) must be install in outlet line from the coil, if the supply water temperature exceeds 95 C. Water installation shall be fixed in such a way that the heater connections not rested the burden of pipelines. During the installation the heater to the water pipeline, you must hold the key socket the heater to prevent the twisting action that can result in leaks to the exchanger. Damage resulting from compliance to the above recommendations is not covered by the warranty. Cost of replacement or repair of the coil is charged to the user. 6.3 Electrical installation Electricity supply device must be performed in accordance with the relevant provisions and standards. Device connection must be performed according to the schematics shown. Wiring diagrams can be found on individual components or elements of the automation device. Electrical installation connection to AGB should perform suitably qualified person, familiar with this Technical Documentation AGC AGC ZW RP TP WG ~230 V WG ~230 V Fig No 3 Electrical schema with automation Fig No 4 Electrical schema without automation RP fan speed control TP room thermostat ZW 2-way control valve with electromotor actuator WG main switch

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 7/8 7. AGB INITIAL START-UP After mounting and installing AGC of all connections of power supply, installation and automation, the following steps should be done: - check the automation - check for leaks water heater - purge the heater. In the case of validating all connections, you're ready to start the device as follows: - set the fan speed control knob into position "0" - turn the main switch on - set the desired speed RPM on speed controller - turn on the switch and set the thermostat to the desired air temperature. At initial AGB start-up should be completed the SERVICE INITIAL CARD 8. AGB OPERATIONS AND USING 8.1 Switching on - set the fan speed control knob into position "0" - turn the main switch on - set the desired speed RPM on speed controller - turn on the switch and set the thermostat to the desired air temperature. In the event of fall of water from the heater, before restarting it you must purge the heater by using stoppers located on the connectors. 8.2 Switching off - set the thermostat temperature knob in the position min. or set the thermostat switch in position "0". The thermostat will transmit a signal to shut down the heater water valve. - set the fan speed control in position "0" - turn off main switch Turning off the fan switch on the controller in the position "0" will not close the water valve the heater still works. 8.3 Service operation The operation of the device is limited only to periodically check the status of the impeller bearings (the fan impeller should rotate freely around its axis-without a fight and taps) and periodically blowing the water coil fins surface from dust and dirt. 9. SERVICE - INFORMATION Information about unit operation can be obtained at the Service Department: Fax: (+48 58) 783 98 88 Phone: (+48 58) 783 99 50/51 Mobile: (+48) 510 098 081 E-mail: serwis@klimor.pl

GDYNIA HEATING AND COOLING DEVICE - AGC 2013 8/8 10. SERVICE INITIAL CARD Data Place Serviceman name Serial number of AGC device Service Company (stamp and signature) Installation steps (description) Notes Confirmation of the performed actions by user Sign Date