Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Similar documents
MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Precise Temperature Control; Compact Footprint

Portable Vertical Air-Conditioning and Heating Systems

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Brasch Hazardous Location Unit Heaters

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

RSG16**S1M. Split System Air Conditioner 16 SEER

FX5 Series Explosion-Proof Electric Air Heaters

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

OACS Outdoor Air-Cooled Central Chillers

Call us today! (800)

SENTRA Series Water Unit

Call us today! (800)

Call us today! (800)

Air-Cooled Condensers

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Product Chillers A P P L I C AT I O N S

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

PACKAGED AIR COOLED Product Data Catalog

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

AIR COOLED PACKAGED CHILLER

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

30GN FLOTRONIC II AIR-COOLED CHILLERS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

NQ Series Portable Chillers

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

30GT FLOTRONIC AIR-COOLED CHILLERS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

LQ AQ SQ. Air-cooled and water-cooled portable chillers

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LQ AQ SQ. Air-cooled and water-cooled portable chillers

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Cool Your Self with. Dana Water Chillers COMPANY PROFILE. The Coolest One.

Air cooled industrial chillers

SECTION AIR COMPRESSORS AND ACCESSORIES

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

CENTRAL SPLIT UNIT UNIC

WCH5**4. Product Specifications

POULTRY MARKET CATALOG

General Description. Operation

CF1 ProVector Explosion-Proof Heaters

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

Thermal Management and Signaling Technology

CX1 ProVector Explosion-Proof Heaters

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Comfort. Description. Applications

SECTION ROTARY-SCREW WATER CHILLERS

Technical Data Manual Model Nos. and pricing: see Price List

T P A 120 S 4 S N 1 Y

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

JCseries EVAPORATIVE CONDENSER. engineering data

Centro-Matic Automated Lubrication Systems System Controls

2 shp 13 lc 1 36 t - 1 a

TECHNICAL SPECIFICATIONS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

DCG Commercial. Submittal Data Form

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

PRODUCT SPECIFICATIONS

Transcription:

Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key element in each Rite-Temp water chiller. Over the years, our water chillers have been subjected to the most critical on-the-job performance evaluations. The result has been proven reliability and a reputation for a solid quality machine. Rite Temp manufactures water chillers for a wide range of industrial and commercial applications. Flexibility of design and product adaptability set us apart in the industry. Each unit is individually constructed to meet your exact specifications. Our Portable and Horizontal units are available in 2 12 ton capacities and the Vertical unit we offer is available in 2-24 ton capacities. Our Remote units are available in 2 36 ton capacities.

Coil-In-Tank Design: Exclusive stainless steel coil-in-tank design can be found in every Rite-Temp Chiller. This patented design eliminates freeze-up problems such as coil rupture often associated with tube-in-tube heat exchangers. Head pressure on the Rite-Temp refrigeration system is not affected by pressure shock,due to the high temperature return water. The tough, 40 gallon, 16 gauge, 304 stainless steel construction ensures years of efficient quality operation. Refrigeration System: The finest in performance, capacity, and design. Our system is manufactured completely in our plant using the industry respected Copeland compressor. All condenser coils are formed and assembled in-house for better quality assurance and design flexibility. The control panel has been engineered for simplicity using only the finest U.L..Approved components. All 8 ton larger units are equipped with multi compressor systems that will operate independently as the load requires, resulting in energy savings. Alternative refrigerants are available. Cabinet Construction: Each unit is constructed on a rugged, heavy duty steel base frame. The cabinet and access panels are manufactured from 18 and 20 gauge sturdy Phos Coat galvanized steel and are finished with a tough chemical and weather resistant polyester powder coat ensuring years of dependable corrosion protection. We will custom finish to your color specifications on request.

Water Circuit: The water circuit in the Rite-Temp chiller features a heavy-duty, high head, water pump with a precision molded impeller providing the highest performance and efficiency. Larger pump ratings as well as special application pumps, such as stainless steel, brass or bronze are available. Electrical System: Wired 208/230 or 460 volts, 3 phase as standard. Any electrical system can be engineered on request, including 50 Hz systems and 208/230 volt single phase. The control panel can be wired for a 24 or 110 volt system, with only the highest standard U.L. Approved electrical components. As an optional feature, NEMA and JIC design panel enclosures are available. All units 2 12 ton capacities are ETL certified. The Company: Our unique Closed, Tube-In-Tank design improves operating costs, eliminates downtime due to contaminates and puts an end to the problems with low or uncertain water pressure, evaporation and overflow. Each Rite-Temp chiller must undergo a series of tests and pass our rigid quality assurance standards before leaving our plant. A solid, one year warranty on parts and components, with five years on the compressor. Straight forward and simple! We stand behind our products with years of experience and a technical staff always ready to assist you our reputation depends on it.

Low sound levels and high energy efficiency and the ability to eliminate water usage in most cases are essential to the successful operation of facilities. Advanced features, serviceability, resulting in lower maintenance costs. Rite-Temp air cooled condensers bring innovative advancements that provide you with the best product solutions to meet the demanding needs of applications. Benefits are a very easy connection using the optional 25 or 50 foot pre-charged line sets. The air cooled unit features a pressure switch and standard low ambient control to keep the refrigeration pressures in the proper range regardless of climate or temperature during the complete cycle. Performance Features Baldor 1/2hp condenser fan motor and 1075 RPM s Condenser coil copper tube with aluminum plate finned coils Low ambient control standard no additional charge Reliability Features Galvanized weather resistant cabinet Corrosion-proof fan guards Maintenance Features Quick removal access panels Permanently lubricated fan and motor bearings Installation Features Refrigerant connections Easy changeover single voltage design for 208/230- v or 460-v operation Single point electrical connection Standard Warranty One-year product Note ( Optional Line Sets) The lines should be connected with a small amount of oil on the threads.. Only use crescent wrenches so that the nuts cannot be warped. The 5/8 tubing (smaller) goes to the connection on the machine marked (5/8 ) and the larger tubing connects to the 7/8 marked fitting. The unit requires a 220 volt single phase 15 amp power connection and DOES not have to be connected to the machine.

RITE-TElVIP 1\tiFG. GALVANIZED CONDENSER TOP DISCHARGE RTC 8-10 TON CONDENSER TOP VIE'-V