Installation Instructions and Operation & Maintenance Guide

Similar documents
INSTALLATION GUIDE AND WARRANTY INFORMATION

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Installation Instructions

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Installation Manual. Top of Pole Mount Edition v1.01. For models:

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Bathroom Exhaust Fan

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

DIRTY WATER SUBMERSIBLE PUMP

DIRTY WATER SUBMERSIBLE PUMP KIT

SUN EQUINOX HEATING SYSTEMS

gamma pond Ultraviolet Sterilizers

User s guide RUH series Economical unit heater Replacement component list included

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

General System Layout Sketch

Heated Display Cabinet Installation & Operating Instructions

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

Whirlpool Bathtub Model Number: MT618

MaxLite LED High Bay Fixtures

General System Layout Sketch

Installation Instructions

Portable Refrigerator

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Pole Mounting System Installation & Certification Manual

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

- Do not Discard these instructions; please save them for later use/reference.

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

FRONT PORCH SUNSHINE REQUEST FOR QUOTATIONS CONTRACTOR AND SYSTEM QUALIFICATIONS

OPERATION & INSTALLATION MANUAL

Installation & Service Manual

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

MIGHTY PRO 1/4 HP CHILLER

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

MaxLite Polygon Linear LED Light

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

DIRTY WATER SUBMERSIBLE PUMP

Owner s Manual. Solar Storage Tank with Heat Exchanger Model DSTA-200

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

OWNER S MANUAL

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³).

ispring Whole House Water Filter Systems USER S MANUAL

INSTANT WATER HEATER INSTANO 1L / 3L (Litre)

Installation and Operating Instructions

Pole Mounting System Installation & Certification Manual

SUBMERSIBLE WATER PUMP

Whole House Filter Model: WH-LD

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

K W H - I N 1 H o t S p l a s h I N S TA N T W AT E R G E Y S E R

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

User Manual. Deep Cleaning Bagless Vacuum with Powerhead. Deep Clean W3000

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

Installation Instructions Solar Controller Kit (Part Number AQ )

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

Complete Cleaning System

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Zeus Extreme Owner's Manual

Installation and Operating Instructions

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Please Keep This Manual For Future Reference REV.01

Owners Manual. 900 Series Drinking Water Appliance

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Owner s Manual & Safety Instructions

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

DEHUMIDIFIER. User Manual 50BT, 70BT

Powerflow Unvented water heater

PORTABLE AIR CONDITIONER OWNER S MANUAL

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

GEOTHERMAL STORAGE TANKS

INSTALLATION INSTRUCTIONS USER GUIDE

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Zen Boiling Tap Range

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

OWNER'S MANUAL. RSL-2701U (for CANADA MODEL) RSL-2701S (for USA MODEL ) Royal Sovereign International Inc.

Owner & Operator Manual

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

OPERATING AND INSTALLATION MANUAL

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Owner & Operator Manual

Installation, Operation & Service Manual

Whynter Portable Ice Maker 33 lb capacity - White

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Transcription:

Installation Instructions and Operation & Maintenance Guide The SOLAV is the first Integrated Polymer Based Solar Water Heater, made of Polypropylene. This type of plastic is FDA approved for direct contact with food and potable water. Among its advantages are no accumulation of Lime-Scale, Corrosion Resistance, Flexibility (Freeze and Hail Resistant), 100% Recyclable and more. Proper installation and care will provide you with many years of solar heated water. PLEASE READ THIS ENTIRE MANUAL BEFORE BEGINNING INSTALLATION OR ATTEMPTING TO OPERATE THIS SYSTEM. For record keeping and documentation, please write the serial number and installation date of your SOLAV water heater in the maintenance section of this manual. This manual should be stored safely for future reference and maintenance.

Installation Step by Step Preparation Prepare your Home Installing a new water heater is the perfect time to examine your home s plumbing system and make sure the system is up to current code standards. Verify that the structure can support the full weight of the SOLAV (approximately 120kg per unit). Ensure there is enough access space to the system for installation and maintenance. Sunlight Exposure Orientation: The performance of solar water heating systems in the Northern Hemisphere is optimal when the collector is mounted facing True South. Performance, however, suffers very little when the collector is oriented no more than 15 East or West of True South. Tilt: Optimal annual efficiency is achieved by tilting the SOLAV solar collector at an angle that equals your latitude plus an additional 10, but no less than 22.5 from the horizon. This tilt angle favors the lower winter sun when collector performance is at its lowest and minimizes overheating during the hottest summer months. Shading: The collector should be un-shaded by any permanent obstructions between 09:00 and 17:00 on any day of the year. Water Pipes and Accessories: Install the SOLAV as close to the hot water taps as possible, using a minimal length of piping in order to reduce heat loss from the pipes. All pipes must be insulated. Solav Energy recommends using PP, PEX or PEX-Al-PEX pipes with a diameter of 20mm (preferably) or 16mm. Use approved compression fittings only. Never use fittings that require Soldering or Brazing as they may harm the SOLAV. Outdoors: The SOLAV is designed for outdoor use and is UV & weather resistant. Do not install the SOLAV indoors or in a shaded area as the system relies on Solar Radiation to heat the water in the system. Sunlight: To maximize efficiency, install the SOLAV in a sunny location without permanent shading between 09:00-17:00. Trim trees that cast a shadow and regularly clean the clear collector surface using water only. Room/Space for Servicing: Before installing the SOLAV, verify there is enough room around the system for easy maintenance access. Install the SOLAV only on a structure that can bear the full load of the system (approximately 120 kg per unit). If no structure is available but a connection to a main water supply is present, install the SOLAV on the ground according to the sections above. Damage to structure caused by leaks: Ensure a proper draining from the SOLAV to avoid structural damage, which may pose a risk to property and lives

Installing the SOLAV 2.1 Place the SOLAV's base in a manner that the glazing is faced due true South. Anchor the base to the structure or the floor safely (120 kg Gross per unit). Ensure an obstacle free route for moving the SOLAV to its place. Using 2 people, carefully place the SOLAV on the base, glazing faced up and "THIS SIDE UP" arrows pointing upwards (Barcode should be on the top of the SOLAV). Warning: Cover the SOLAV's Glazing until installation is complete to avoid accumulation of hot air in the SOLAV body that may cause a risk of injury. 2.2 Connecting the Threads 2X PP Threaded Plug 2X PP Threaded Bushing Additional accessories: PTFE sealing tape, and suitable connectors (¾"F) to the pipes used. Solav Energy recommends using PP, PEX, or PEX-Al-PEX pipes. Wrap all threads with PTFE tape: Connect ¾"Mx¾"F PP Threaded Bushing to the bottom thread marked "INLET" Connect ¾"Mx¾"F PP Threaded Bushing to the top left thread marked "OUTLET" Connect ¾"M PP Threaded Plugs to the remaining top and bottom threads As the SOLAV's body is comprised of plastic, exposure to excessive heat (>95 C) can damage the SOLAV. Once full, close the inlet tap and connect Piping to the Hot Water Outlet Open the hot water taps in the house, then open the cold water tap and allow remaining air bubbles to exit the system until a steady flow of water is achieved. Close taps in the house, then check for leaks and repair if needed. Remove all covers from the glazed screen An air relief valve may also be added in order to drain the system from air without disassembly and to prevent bubble formation in the tap's stream of water. Fix the air relief valve vertically in a high point where air can be channeled out of the system. Verify that all steps have been properly completed. Repair any faults (if needed). Threads: Important note: The plastic threads in the SOLAV unit are easily damaged when threading metal parts. Therefore, plastic fittings have been provided for connecting the SOLAV to the existing mains. Only these items are approved for use. Installation of non-approved threaded fittings could risk the unit's threads and will result in loss of warranty. Make sure you have all the provided accessories: 2.3 Connecting the Water Supply Pipes and Insulation: All pipes must meet local codes and standards for hot water pipes. The diameter should be 20mm (preferably) or 16mm. All pipes must be insulated according to local codes and standards. Connect Piping to the Cold Water Inlet and fill the SOLAV with water.

Solav Energy Warranty This warranty is an integral part of the general terms of use and it determines the conditions of liability for Integral Solar Water Heating System (hereafter referred as The Product ) of Solav-Dolav Solar Energy Cooperative Ltd. (hereafter referred as The Company ) 1. The Company undertakes that under regular terms of installation, use and service, the Product is free of any defects of manufacture. 2. The Company warrants the Product against manufacturing defects and faulty materials for a period of five (5) years, starting from the delivery date of the Product. 3. The Company warrants the kit of components supplied with the system for a period of one (1) year, starting from the delivery date of the Product. 4. Within the warranty period The Company undertakes to repair or replace, at its sole discretion, any part / component of the Product which is found to be having manufacturing defects or is unserviceable. 5. The Company may at its sole discretion replace the whole Product if found necessary by virtue of the nature of fault or defect. In that case, the warranty will continue for the rest of the original period. Such defects, if noticed by the customer, should be reported to the Company's representative immediately upon its discovery. 6. The Company shall be under no obligations under this warranty, if the Company is satisfied that the defects are due to improper storage, usage, negligence, any modifications/ alterations or tampering, over pressure, change of design/pattern of usage, accident, act of god or installation/repairs carried out by any person not duly authorized by the Company or by any reason beyond the control of The Company such as theft, war, earthquake, flood or storm & such other natural calamities like hailstorm, typhoon or cyclones, uprooting of trees or electric poles, wire & radio or T.V. antennas etc. causing accidental damage to the Product. 7. This warranty excludes any damage inflicted by vandalism or by animals such as dogs, monkeys, domestic animals, birds or any other creatures. 8. Under this warranty, no responsibility is accepted for any consequential loss or damage caused by any defect. 9. The repair or replacement, if any, shall be carried out by the Company or by its authorized dealer or representative within the reasonable time required for communication, processing the complaint, procurement of the component, transportation of material and appointment of an authorized person for examination & determination of remedial action to be taken to solve the problem. It is essential that the customer should grant access to the Company s representative for examination of the solar water heating system in full and facilitate the repairs as and whenever convenient to the customer and the Company s representative. 10. The Product is designed to withstand ambient temperatures no less than minus five degrees centigrade (-5 C). 11. This warranty in no case shall extend to payment of any monetary consideration or compensation. 12. This warranty automatically becomes void on expiry of the warranty period. Company Signature Date Serial Number Installation Date Installed by Signature

Installation Instruction and Use & Care Guide The SOLAV is the first Integrated Polymer Based Solar Water Heater, made of Polypropylene. This type of plastic is FDA approved for direct contact with food and potable water. Among its advantages are no accumulation of Lime- Scale, Corrosion Resistance, Flexibility (Freeze and Hail Resistant), 100% Recyclable and more. Proper installation and care will provide you with many years of solar heated water. PLEASE READ THIS ENTIRE MANUAL BEFORE BEGINNING INSTALLATION OR ATTEMPTING TO OPERATE THIS SYSTEM. For record keeping and documentation, please write the serial number and installation date of your SOLAV water heater in the maintenance section of this manual. This manual should be stored safely for future reference and maintenance.

Installation Step by Step Preparation Prepare your Home Installing a new water heater is the perfect time to examine your home s plumbing system and make sure the system is up to current code standards. Verify that the structure can support the full weight of the SOLAV (approximately 120kg per unit). Ensure there is enough access space to the system for installation and maintenance. Sunlight Exposure Orientation: The performance of solar water heating systems in the Northern Hemisphere is optimal when the collector is mounted facing True South. Performance, however, suffers very little when the collector is oriented no more than 15 East or West of True South. Tilt: Optimal annual efficiency is achieved by tilting the SOLAV solar collector at an angle that equals your latitude plus an additional 10, but no less than 22.5 from the horizon. This tilt angle favors the lower winter sun when collector performance is at its lowest and minimizes overheating during the hottest summer months. Shading: The collector should be un-shaded by any permanent obstructions between 09:00 and 17:00 on any day of the year. Water Pipes and Accessories: Install the SOLAV as close to the hot water taps as possible, using a minimal length of piping in order to reduce heat loss from the pipes. All pipes must be insulated. Solav Energy recommends using PP, PEX or PEX-Al-PEX pipes with a diameter of 20mm (preferably) or 16mm. Use approved compression fittings only. Never use fittings that require Soldering or Brazing as they may harm the SOLAV. Outdoors: The SOLAV is designed for outdoor use and is UV & weather resistant. Do not install the SOLAV indoors or in a shaded area as the system relies on Solar Radiation to heat the water in the system. Sunlight: To maximize efficiency, install the SOLAV in a sunny location without permanent shading between 09:00-17:00. Trim trees that cast a shadow and regularly clean the clear collector surface using water only. Room/Space for Servicing: Before installing the SOLAV, verify there is enough room around the system for easy maintenance access. Install the SOLAV only on a structure that can bear the full load of the system (approximately 120 kg per unit). If no structure is available but a connection to a main water supply is present, install the SOLAV on the ground according to the sections above. Damage to structure caused by leaks: Ensure a proper draining from the SOLAV to avoid structural damage, which may pose a risk to property and lives

Installing the SOLAV 2.1 Place the SOLAV's base in a manner that the glazing is faced due true South. Anchor the base to the structure or the floor safely (120 kg Gross per unit). Ensure an obstacle free route for moving the SOLAV to its place. Using 2 people, carefully place the SOLAV on the base, glazing faced up and "THIS SIDE UP" arrows pointing upwards (Barcode should be on the top of the SOLAV). Warning: Cover the SOLAV's Glazing until installation is complete to avoid accumulation of hot air in the SOLAV body that may cause a risk of injury. 2.2 Connecting the Threads 1X PP ¾" Threaded Plug 1X PP ½" Street Elbow 1X ½" Pressure Relief Valve 2X PP ¾" Threaded Bushing 1X PP Reducing Nipple ¾" X ½" 1X ¾" Pressure Reducing Valve Additional accessories: PTFE sealing tape, Valves (optional), and suitable connectors (¾"F) to the pipes used. Solav Energy recommends using PP, PEX, or PEX-Al-PEX pipes. Wrap all threads with PTFE tape: Connect ¾"Mx¾"F PP Threaded Bushing to the bottom thread marked "INLET" Connect ¾"M Pressure Reducing Valve to the INLET Bushing. Assemble and connect the Pressure Relief Valve, ensure that the Valve's exhaust is horizontal. Connect Plug to Top Right Thread (Unmarked). Threads: Important note: The plastic threads in the SOLAV unit are easily damaged when threading metal parts. Therefore, plastic fittings have been provided for connecting the SOLAV to the existing mains. Only these items are approved for use. Installation of non-approved threaded fittings could risk the unit's threads and will result in loss of warranty. Make sure you have all the provided accessories: Connect ¾"Mx¾"F PP Threaded Bushing to the top left thread marked "OUTLET". As the SOLAV's body is comprised of plastic, exposure to excessive heat (>95 C) can damage the SOLAV. 2.3 Connecting the Water Supply Pipes and Insulation: All pipes must meet local codes and standards for hot water pipes. The diameter should be 20mm (preferably) or 16mm. All pipes must be insulated according to local codes and standards.

Connect Piping to the Cold Water Inlet and fill the SOLAV with water. Open the hot water taps in the house, then open the hot water tap and allow remaining air bubbles to exit the system until a steady flow of water is achieved. Close taps in the house, then check for leaks and repair if needed. Remove all covers from the glazed screen Once full, close the inlet tap. An air relief valve may also be added in order to drain the system from air without disassembly and to prevent bubble formation in the tap's stream of water. Fix the air relief valve vertically in a high point where air can be channeled out of the system. Verify that all steps have been properly completed. Repair any faults (if needed). Connect Piping to the Hot Water Outlet.

Solav Energy Warranty his warranty is an integral part of the general terms of use and it determines the conditions of liability for Integral Solar Water Heating System (hereafter referred as The Product ) of Solav-Dolav Solar Energy Cooperative Ltd. (hereafter referred as The Company ) The Company undertakes that under regular terms of installation, use and service, the Product is free of any defects of manufacture. The Company warrants the Product against manufacturing defects and faulty materials for a period of five (5) years, starting from the delivery date of the Product. The Company warrants the kit of components supplied with the system for a period of one (1) year, starting from the delivery date of the Product. Within the warranty period The Company undertakes to repair or replace, at its sole discretion, any part / component of the Product which is found to be having manufacturing defects or is unserviceable. The Company may at its sole discretion replace the whole Product if found necessary by virtue of the nature of fault or defect. In that case, the warranty will continue for the rest of the original period. Such defects, if noticed by the customer, should be reported to the Company's representative immediately upon its discovery. The Company shall be under no obligations under this warranty, if the Company is satisfied that the defects are due to improper storage, usage, negligence, any modifications/ alterations or tampering, over pressure, change of design/pattern of usage, accident, act of god or installation/repairs carried out by any person not duly authorized by the Company or by any reason beyond the control of The Company such as theft, war, earthquake, flood or storm & such other natural calamities like hailstorm, typhoon or cyclones, uprooting of trees or electric poles, wire & radio or T.V. antennas etc. causing accidental damage to the Product. This warranty excludes any damage inflicted by vandalism or by animals such as dogs, monkeys, domestic animals, birds or any other creatures. Under this warranty, no responsibility is accepted for any consequential loss or damage caused by any defect. The repair or replacement, if any, shall be carried out by the Company or by its authorized dealer or representative within the reasonable time required for communication, processing the complaint, procurement of the component, transportation of material and appointment of an authorized person for examination & determination of remedial action to be taken to solve the problem. It is essential that the customer should grant access to the Company s representative for examination of the solar water heating system in full and facilitate the repairs as and whenever convenient to the customer and the Company s representative. The Product is designed to withstand ambient temperatures no less than minus five degrees centigrade (-5 C). This warranty in no case shall extend to payment of any monetary consideration or compensation. This warranty automatically becomes void on expiry of the warranty period. Company Signature Date Serial Number Installation Date Installed by Signature Installation Instruction and Use & Care Guide

The SOLAV is the first Integrated Polymer Based Solar Water Heater, made of Polypropylene. This type of plastic is FDA approved for direct contact with food and potable water. Among its advantages are no accumulation of Lime- Scale, Corrosion Resistance, Flexibility (Freeze and Hail Resistant), 100% Recyclable and more. Proper installation and care will provide you with many years of solar heated water. PLEASE READ THIS ENTIRE MANUAL BEFORE BEGINNING INSTALLATION OR ATTEMPTING TO OPERATE THIS SYSTEM. For record keeping and documentation, please write the serial number and installation date of your SOLAV water heater in the maintenance section of this manual. This manual should be stored safely for future reference and maintenance.

Installation Step by Step Preparation Prepare your Home Installing a new water heater is the perfect time to examine your home s plumbing system and make sure the system is up to current code standards. Verify that the structure can support the full weight of the SOLAV (approximately 120kg per unit). Ensure there is enough access space to the system for installation and maintenance. Sunlight Exposure Orientation: The performance of solar water heating systems in the Northern Hemisphere is optimal when the collector is mounted facing True South. Performance, however, suffers very little when the collector is oriented no more than 15 East or West of True South. Tilt: Optimal annual efficiency is achieved by tilting the SOLAV solar collector at an angle that equals your latitude plus an additional 10, but no less than 22.5 from the horizon. This tilt angle favors the lower winter sun when collector performance is at its lowest and minimizes overheating during the hottest summer months. Shading: The collector should be un-shaded by any permanent obstructions between 09:00 and 17:00 on any day of the year. Water Pipes and Accessories: Install the SOLAV as close to the hot water taps as possible, using a minimal length of piping in order to reduce heat loss from the pipes. All pipes must be insulated. Solav Energy recommends using PP, PEX or PEX-Al-PEX pipes with a diameter of 20mm (preferably) or 16mm. Use approved compression fittings only. Never use fittings that require Soldering or Brazing as they may harm the SOLAV. Outdoors: The SOLAV is designed for outdoor use and is UV & weather resistant. Do not install the SOLAV indoors or in a shaded area as the system relies on Solar Radiation to heat the water in the system. Sunlight: To maximize efficiency, install the SOLAV in a sunny location without permanent shading between 09:00-17:00. Trim trees that cast a shadow and regularly clean the clear collector surface using water only. Room/Space for Servicing: Before installing the SOLAV, verify there is enough room around the system for easy maintenance access. Install the SOLAV only on a structure that can bear the full load of the system (approximately 120 kg per unit). If no structure is available but a connection to a main water supply is present, install the SOLAV on the ground according to the sections above. Damage to structure caused by leaks: Ensure a proper draining from the SOLAV to avoid structural damage, which may pose a risk to property and lives.

Installing the SOLAV 2.1 Place the SOLAV's base in a manner that the glazing is faced due true South. Anchor the base to the structure or the floor safely (120 kg Gross per unit). Ensure an obstacle free route for moving the SOLAV to its place. Using 2 people, carefully place the SOLAV on the base, glazing faced up and "THIS SIDE UP" arrows pointing upwards (Barcode should be on the top of the SOLAV). Warning: Cover the SOLAV's Glazing until installation is complete to avoid accumulation of hot air in the SOLAV body that may cause a risk of injury. 2.2 Connecting the Threads 1X PP ¾" Threaded Plug 1X PP ½" Street Elbow 1X ½" Pressure Relief Valve 2X PP ¾" Threaded Bushing 1X PP Reducing Nipple ¾" X ½" 1X ¾" Pressure Reducing Valve Additional accessories: PTFE sealing tape, Valves (optional), and suitable connectors (¾"F) to the pipes used. Solav Energy recommends using PP, PEX, or PEX-Al-PEX pipes. Wrap all threads with PTFE tape: Connect ¾"Mx¾"F PP Threaded Bushing to the bottom thread marked "INLET" Connect ¾"M Pressure Reducing Valve to the INLET Bushing. Assemble and connect the Pressure Relief Valve, ensure that the Valve's exhaust is horizontal. Connect Plug to Top Right Thread (Unmarked). Threads: Important note: The plastic threads in the SOLAV unit are easily damaged when threading metal parts. Therefore, plastic fittings have been provided for connecting the SOLAV to the existing mains. Only these items are approved for use. Installation of non-approved threaded fittings could risk the unit's threads and will result in loss of warranty. Make sure you have all the provided accessories: Connect ¾"Mx¾"F PP Threaded Bushing to the top left thread marked "OUTLET". As the SOLAV's body is comprised of plastic, exposure to excessive heat (>95 C) can damage the SOLAV. 2.3 Connecting the Heating Rod Warning! All and any electric work including installation and servicing must be executed by a licensed electrician in accordance to local codes and regulations.

Warning! Do not operate the rod unless it is submerged in water! Ground the Rod in accordance with local codes and regulations. The SOLAV can be fitted with a heating rod as a heating backup. Connect to electric switch, DO NOT TURN THE SWITCH ON. Once full, close the inlet tap. Heating Rod Specifications: P=1000 W v=230 V f=50 Hz IP67 Ensure that the SOLAV is drained of water. Ensure suitable voltage and frequency. Drill a Ø13mm hole concentric with the threads in the middle thread. Remove drilling debris. Wrap PTFE tape on the male thread of the rod (blue). Fill the SOLAV with water according to section 2.4. Check the rod only after the system has been filled with water. Connect Piping to the Hot Water Outlet. 2.4 Connecting the Water Supply Insert rod into drilled hole and tighten the thread using a 27 mm spanner. Pipes and Insulation: All pipes must meet local codes and standards for hot water pipes. The diameter should be 20mm (preferably) or 16mm. All pipes must be insulated according to local codes and standards. Connect Piping to the Cold Water Inlet and fill the SOLAV with water. Open the hot water taps in the house, then open the hot water tap and allow remaining air bubbles to exit the system until a steady flow of water is achieved. Close taps in the house, then check for leaks and repair if needed.

Remove all covers from the glazed screen An air relief valve may also be added in order to drain the system from air without disassembly and to prevent bubble formation in the tap's stream of water. Fix the air relief valve vertically in a high point where air can be channeled out of the system. Verify that all steps have been completed properly. Repair any faults (if needed).

Solav Energy Warranty This warranty is an integral part of the general terms of use and it determines the conditions of liability for Integral Solar Water Heating System (hereafter referred as The Product ) of Solav-Dolav Solar Energy Cooperative Ltd. (hereafter referred as The Company ) 25. The Company undertakes that under regular terms of installation, use and service, the Product is free of any defects of manufacture. 26. The Company warrants the Product against manufacturing defects and faulty materials for a period of five (5) years, starting from the delivery date of the Product. 27. The Company warrants the kit of components supplied with the system for a period of one (1) year, starting from the delivery date of the Product. 28. Within the warranty period The Company undertakes to repair or replace, at its sole discretion, any part / component of the Product which is found to be having manufacturing defects or is unserviceable. 29. The Company may at its sole discretion replace the whole Product if found necessary by virtue of the nature of fault or defect. In that case, the warranty will continue for the rest of the original period. Such defects, if noticed by the customer, should be reported to the Company's representative immediately upon its discovery. 30. The Company shall be under no obligations under this warranty, if the Company is satisfied that the defects are due to improper storage, usage, negligence, any modifications/ alterations or tampering, over pressure, change of design/pattern of usage, accident, act of god or installation/repairs carried out by any person not duly authorized by the Company or by any reason beyond the control of The Company such as theft, war, earthquake, flood or storm & such other natural calamities like hailstorm, typhoon or cyclones, uprooting of trees or electric poles, wire & radio or T.V. antennas etc. causing accidental damage to the Product. 31. This warranty excludes any damage inflicted by vandalism or by animals such as dogs, monkeys, domestic animals, birds or any other creatures. 32. Under this warranty, no responsibility is accepted for any consequential loss or damage caused by any defect. 33. The repair or replacement, if any, shall be carried out by the Company or by its authorized dealer or representative within the reasonable time required for communication, processing the complaint, procurement of the component, transportation of material and appointment of an authorized person for examination & determination of remedial action to be taken to solve the problem. It is essential that the customer should grant access to the Company s representative for examination of the solar water heating system in full and facilitate the repairs as and whenever convenient to the customer and the Company s representative. 34. The Product is designed to withstand ambient temperatures no less than minus five degrees centigrade (-5 C). 35. This warranty in no case shall extend to payment of any monetary consideration or compensation. 36. This warranty automatically becomes void on expiry of the warranty period. Company Signature Date Serial Number Installation Date Installed by Signature