Flueing Installation Manual For Rinnai Flamefire Heaters

Similar documents
Flueing Installation Manual

SLIMFIRE 25 FLAME FIRE. Customer Operation & Installation Manual

Flue Installation Manual

INSTALLATION MANUAL Power Flued Flamefire Space Heater Co-axial Flue System

REFERENCE GUIDE. Heating. Experience Our Innovation

Energysaver Space Heater Co-Axial Flue System Installation Manual

INTERNATIONAL GAS CONVECTOR BOX

Evolve 951 & Product specification pages

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

XANDER INSERT WOOD BURNER

Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters

Twin Wall Installation Instructions And Maintenance Guide

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Operation & Installation Manual

Specification and Installation Instructions

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

Specification and Installation Instructions

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

TRUST ONLY GENUINE COONARA WOODHEATERS

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

TILE ROOF DUCTING KIT. instruction manual VDKRT 12 MONTH WARRANTY

PelletVent Multi-fuel venting system. UL 641.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Installation guide Compact 2

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

Customer Operation & Installation Manual Electric Panel Heaters

Important: Appliance must be installed with a Rinnai approved flue system.

Remote Control Operation Manual Split Type Air Conditioner

IB1100 and IB850 Installation Manual AUSTRALIAN EDITION

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

TRUST ONLY GENUINE COONARA WOODHEATERS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

SERVICE MANUAL Sapphire - RIB2312 GAS LOG FLAME FIRE

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Installation and Maintenance Instructions

Manual FOR YOUR SAFETY

SAPPHIRE GAS LOG FLAME FIRE Operation / Installation Manual

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

SEPARATED COMBUSTION. General WARNING

Installation & Operation Manual Fascia / Firebox / Build-In Cabinet

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

City Series CV40E Gas Fireplace

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Installation Instructions

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

H1200/DS H1400 H1600/DS H1600XXL/DS H1200VLG/D H12003V epi950

INSTALLATION & OPERATING MANUAL

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

ZERO CLEARANCE Z-SYSTEM

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Technical and Dimensional Data. Saf-T Vent SC Plus

ZC Kit AGP Pellet Insert

Energysaver Space Heater Co-Axial Flue System Installation Manual

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

INSTALLATION AND OPERATING INSTRUCTIONS MAUI GAS FIRES FREESTANDER AND INBUILT NATURAL GAS / LPG HEATER

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

ZERO CLEARANCE BOX INSTALLATION INSTRUCTIONS

P P Gas Fireplace. P See Thru

Product Catalogue 10YEAR. Fitzroy Profile and Canterbury Classic Series 2015 WAR RAN T Y YEAR

Installation Instructions

Manual. P36 Gas Inbuilt Calais / Grenada. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: P36-NG3 P36-LPG3

BDM Direct Vent systems are for use with direct vent gas fired appliances.

DaVinci Heat Exchanger Touch-Screen Version

Greenfire GF1500LST Gas Fireplace

ULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual

Pizza Oven with Stand

INSTALLATION & OPERATING MANUAL

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

ZERO CLEARANCE Z-SYSTEM

WOOD HEATING COLLECTION

Studio 2. Balanced Flue with Thermostatic Remote Control. Installation Instructions. For use in AU (Australia). IMPORTANT

Greenfire GF950L Gas Fireplace

SEPARATED COMBUSTION. General

Manual. PG33 Gas Inbuilt. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: PG33-NG PG33-LPG

INSTALLATION INSTRUCTIONS

Operation / Installation Manual

Miniboil Boiling Only

Installation Instructions Solar Controller Kit (Part Number AQ )

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

Europa 7 Europa 7 VL Multivision 8000 Series Super 9 Visio 8 Plus

ULTIMA II. Flued Space Heater Operation / Installation Manual. MODEL REH-311FT(B) - Inbuilt MODEL REH-311FT(C) - Console

IS 900 Insert - Charcoal THE WORLD S MOST EFFICIENT GAS LOG SPACE HEATERS WITH THE HIGHEST ENERGY STAR RATING!

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

INSTALLATION & USER INSTRUCTIONS

DaVinci Heat Exchanger

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Energysaver Space Heaters Models: RHFE-309FT & RHFE-559FT Operation and Installation Manual

Transcription:

Flueing Installation Manual For Rinnai Flamefire Heaters To Suit Models: FS35ETR Royale ETR - Freestanding FS35 Royale - Freestanding IB35ETR Royale ETR - Inbuilt IB35 Royale - Inbuilt RIBF2 / IB25 Slimfire 252 / 25 - Inbuilt IB300ETR Reflection - Inbuilt RIB2310M Sapphire - Freestanding/Inbuilt Installation shall be in accordance with: Manufacturer s Installation Instructions Current AS/NZS3000, AS/NZS3500 & AS5601 Local Regulations and Municipal Building Codes Installation, service and removal by an Authorised Person only. Proudly a member of the A.G.A. All of our gas products are A.G.A. tested and approved Distributed and serviced in Australia under a Quality System certified as complying with ISO 9001 by SAI Global

This page intentionally blank. Rinnai i Installation Manual

TABLE OF CONTENTS REGULATIONS & FLUEING OPTIONS...1 Regulations Genuine Rinnai Flue Kit Flueing Options CONNECTING DIRECT RIGID FLUEING TO HEATERS...2 Flue Connection Procedure DIRECT RIGID FLUEING USING FLFKIT05...3 FLFKIT05 Components List Additional Components DIRECT RIGID FLUEING USING FLFKIT05...4 FLFKIT05 Assembly Procedure OFFSET RIGID FLUEING USING FLFBEND...5 FLFBEND components: Additional Components: FLFBEND Assembly Procedure THROUGH WALL RIGID FLUEING USING FLFTWKIT...6 FLFTWKIT Components List Additional Components: THROUGH WALL RIGID FLUEING USING FLFTWKIT...7 FLFTWKIT Assembly Procedure CONTACT INFORMATION...8 All Rinnai Flamefire rigid flue kits are certified twin wall metal systems as defined in AS 5601. This does NOT apply to flexible flue kits! Rinnai ii Installation Manual

This page intentionally blank. Rinnai iii Installation Manual

REGULATIONS & FLUEING OPTIONS Regulations Installation of this flue must be in accordance with the following regulations: Current AS5601 Manufacturers Instructions Local regulations & municipal building codes Installation, Service & Removal by an Authorised Person only. Genuine Rinnai Flue Kit Rinnai appliance warranty conditions will be voided if non Rinnai flue components are fitted. Rinnai appliances are NOT CERTIFIED for use with non Rinnai flue components. Flueing Options Below are the flueing options that are available with Rinnai Flamefire appliances. Refer to the relevant section of this manual for detailed installation instructions for each option. OBSTRUCTION OBSTRUCTION A B C D E F G ZERO CLEARANCE BOX ZERO CLEARANCE BOX ZERO CLEARANCE BOX MASONRY FIREPLACE HEATER HEATER HEATER HEATER HEATER HEATER HEATER Direct rigid flueing Flue is run direct from appliance to the termination point. This method to be used with Rinnai Freestanding Flamefire models: This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: Offset rigid flueing Flue is run offset from appliance to the termination point to avoid obstructions in the flues path. This method to be used with Rinnai Freestanding Flamefire models: This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: Through wall rigid flueing Flue is run offset through an external wall from appliance to the termination point. This is particularly useful in multi storey applications. This method to be used with Rinnai Freestanding Flamefire models: This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: Flexible flueing Used when installing Rinnai Flamefire appliances into masonry fireplaces. Flueing is mandatory for all models except for the RIBF2 / IB25 Slimfire, IB300ETR Reflection & RIB2311M / RIB2310M Sapphire. Detailed installation instructions are supplied seperately with these flue kits. This method to be used with the following Rinnai Inbuilt models: IB35 / IB35ETR Inbuilt Royale / Royale ETR and IB300ETR Reflection use Kit FLEXLINER01 RIBF2/IB25 Slimfire and RIB2311M/RIB2310M Sapphire Inbuilts use Kit FLEXLINER03 CAUTION A Zero Clearance Box is required for all false or non masonry fireplace installations, see heater installation instructions for details. Under NO CIRCUMSTANCES should a flexible flue kit be used with a Zero Clearance Box in a false or non masonry fireplace installation. Rinnai 1 Installation Manual

CONNECTING DIRECT RIGID FLUEING TO HEATERS Flue Connection Procedure Position and install Heater models in accordance with instructions supplied with the heater and/or Zero Clearance kit.! Common Connections 1 1. Set slip socket onto the swaged end of the inner flue pipe, allowing sufficient adjustment to enable the flue assembly to be lifted clear of the appliance. 2. Connect the slip socket and inner flue pipe assembly to heater flue spigot (appliance adapter spigot of RIBF2/IB25 & RIB2311/ RIB2310 iii ), using the appropriate Freestanding i / Inbuilt ii or iii methods. Once in position tighten the clamp of slip socket to secure the inner flue pipe to the heater flue spigot. 3. Slide appliance outer flue (short swage end towards heater) over the inner flue pipe. i A Freestanding Connections FS35/ETR & RIB2310 2 B FLAMEFIRE FS35 / FS35ETR For Freestanding appliances i fit outer flue directly to the top of the heater. Ensure the appliance adapter collar is seated flush with the top of the heater as shown. For Inbuilt appliances ii or iii fit outer flue to the top panel of the Zero Clearance box. Ensure the appliance adapter collar is seated flush with the top panel of the Zero Clearance Box as shown. APPLIANCE ADAPTER COLLAR TOP PANEL OF HEATER 3 C APPLIANCE ADAPTER COLLAR ii Inbuilt Connections FS35/ETR & IB300ETR 2 B Zero Clearance Box iii Inbult Connections RIBF2/IB25 & RIB2311/RIB2310 2 B Zero Clearance Box FLAMEFIRE IB35 / IB35ETR Removeable panel for access to flue connections. C APPLIANCE ADAPTER COLLAR RIBF2/IB25 & RIB2311/RIB2310 Appliance Adapter Removeable fascia and panel for access to flue connections. APPLIANCE ADAPTER COLLAR C APPLIANCE ADAPTER COLLAR 3 Zero Clearance Box APPLIANCE ADAPTER COLLAR 3 Zero Clearance Box Rinnai 2 Installation Manual

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 DIRECT RIGID FLUEING USING FLFKIT05 Direct rigid flueing is used when running a flue direct from appliance to the termination point. The flue components supplied in Rinnai FLFKIT05 are best suited for this type of installation. The FLFKIT05 can be fitted to Inbuilt and Freestanding Rinnai Flamefire models. When installing this kit with Inbuilt models a zero clearance box is required. FLFKIT05 Components List Slip socket 100mm Galvanised (x1) Inner Flue Pipe 900mm x 100mm Galvanised (x4) Appliance - Outer Flue Pipe 900mm x 145mm Powder Coated (x1) Standard - Outer Flue Pipe 900mm x 145mm Powder Coated (x2) Ceiling Cover Plate + 4 Fixing Screws Powder Coated (x1) Slip Joint 900mm x 150mm Galvanised (x1) Flue Mounting Bracket Galvanised (x1) Spacer (Spider) Clip Stainless Steel (x1) Flue Terminal Skirt Galvanised (x1) Flue Terminal Galvanised (x1) Additional Components (Items not included in kit FLFKIT05) FLF0900 Standard Flue Extension Pipe - inner and outer Outer - Powder coated 900mm x 145mm (x1) Inner - Galvanised 900mm x 100mm (x1) Zero Clearance Boxes ZEROR - IB35/IB35ETR Royale Inbuilt. ZEROS - RIBF2/IB25 Slimfire Inbuilt. ZBOXREF - IB300 Reflection Inbuilt. R2340 - RIB2310 Sapphire Inbuilt. APPLIANCE ADAPTER COLLAR Top-deck of appliance Rinnai 3 Installation Manual

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 DIRECT RIGID FLUEING USING FLFKIT05 FLFKIT05 Assembly Procedure Position and install Freestanding Heater models in accordance with instructions supplied with the heater. Position and install Inbuilt Heater & Zero Clearance kit using instructions supplied with Heater & Zero Clearance kit. 1. Check roof space for any obstructions. If the required clearance from combustible material can not be obtained, consider an offset installation. 65mm 2. Set plumb bob from ceiling to centre of flue outlet on heater, marking the centre position on ceiling. 3. Cut 150 mm circle in ceiling to accommodate flue penetration. 4. Screw ceiling cover plate to ceiling with the powder coated screws provided. 5. Fit flue the assembly, and to the heater as per Connecting Direct Rigid Flueing to Heaters on page 2. 6. Connect subsequent inner and standard outer flue pipes into place. Join inner flues with three galvanised screws or rivets. Repeat for and pipe lengths as required FLUE TERMINAL / SKIRT AND INNER FLUE RIVETED TOGETHER Continue assembly to the flue terminal to ensure compliance with current AS5601. Minimum clearance from roof 500mm. MINIMUM CLEARANCE 500 mm 7. Fit slip joint and mounting bracket to end of the outer flue pipe and slip downward. 8. Fit spacer (spider) clip and secure to inner flue pipe 65mm from the end of the pipe. 9. Fit terminal skirt and flue terminal to the inner flue pipe securing all three together with three galvanised screws or rivets. 10. Slide slip joint upwards so that the legs of the spacer (spider) clip are covered then secure with three galvanised screws or rivets. 11. Secure mounting bracket to slip joint in ceiling space to support the weight of the flue system, and not place strain on roof flashing as per AS5601. TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm Flue Terminal Assembly Details Flash roof penetration by approved methods. (Roof flashing materials are not included in flue kit). Total vertical flue length MUST BE at least 3 metres. Rinnai 4 Installation Manual

OFFSET RIGID FLUEING USING FLFBEND When an obstruction prevents the use of a direct rigid flue run from the appliance to the termination point a FLFBEND kit consisting of two 45 offsets can be used to divert the flue. The FLFBEND is used in conjunction with a FLFKIT05 flue kit. The offset length can be increased by the inclusion of FLF0900M standard inner/outer flue lengths, either used in whole or cut to size. FLFBEND components: Inner 45 Elbow 100mm Galvanised (x2) Outer 45 Elbow 145mm Powder Coated (x2) Additional Components: (Items not included in kit FLFBEND) FLF0900M Standard - outer/inner flue pipe Outer - Powder coated 900mm x 145mm (x1) Inner - Galvanised 900mm x 100mm (x1) FLFBEND Assembly Procedure The vertical length of flue pipe between the heater and the first inner 45 elbow (FLFBEND) should be as long as the installation allows, and at least 900mm. A Standard length of flue can be used to increase the offset 1. Connect inner 45 elbow onto the un-swaged end of an inner flue and join with three galvanised screws or rivets. 2. Slide outer 45 elbow over the inner Flue 45 Elbow and connect to outer flue pipe or. At this point to extend the offset length use a combination of standard inner and outer flue pipe lengths, joining the inner flue sections with three galvanised screws or rivets. The offset length can be customised by cutting the extension components to size as required. 3. Connect second inner 45 elbow onto the preceding inner section and join with three galvanised screws or rivets. Connect the second outer 45 elbow over the preceding outer section. 4. Join subsequent inner and standard outer flue pipes fixing inner sections with three galvanised screws or rivets. Continue assembly to the heater and flue terminal as per the Direct Rigid Flueing instructions on page 4. or See Note Total vertical flue length MUST BE at least 3 metres. Rinnai 5 Installation Manual

THROUGH WALL RIGID FLUEING USING FLFTWKIT Through wall rigid flueing is used to divert a flue run from appliance through an exterior wall to the termination point. The FLFTWKIT provides a 45 wall penetration offset with an adjustable flashing plate. As such the FLFTWKIT is ideal for two storey applications. HEATER HEATER The FLFTWKIT is used in conjunction with a FLFKIT05 flue kit. For extended external flue runs, the FLFEXT03 kit must also be used. FLFTWKIT Components List Inner 45 Elbow 100mm Galvanised (x2) Lower Outer 45 Elbow 145mm Powder Coated (x1) Internal Wall Plate + 4 Fixing Screws Powder Coated (x1) Inner Extension Pipe 100mm Galvanised (x1) Spacer Clamp 100mm Stainless Steel (x1) Outer Extension Pipe 145mm Powder Coated (x1) Transition Slip Joint 145~150mm Galvanised (x1) Outer Transition / Wall Plate 150mm Powder Coated (x1) R or V U M T S Upper Outer 45 Elbow 150mm Galvanised (x1) Additional Components: (Items not included in kit FLFTWKIT) Q P FLFEXT03 External Pipe Extension & Bracket 900mm x 150mm Galvanised (x1) 900mm x 100mm Galvanised (x1) 150mm Galvanised Victor-clip (x1) O N The FLFTWKIT outer transition has a diameter of 150mm. For extended external flue runs only FLFEXT03 external pipe extensions are compatible. The standard outer flue pipes have a diameter of 145mm and are therefore not compatible. or See Note M The vertical length of flue pipe between the heater and the first inner 45 elbow (FLFTWKIT) should be as long as the installation allows, and at least 900mm. Rinnai 6 Installation Manual

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 THROUGH WALL RIGID FLUEING USING FLFTWKIT FLFTWKIT Assembly Procedure Typical Freestanding Installation The vertical length of flue pipe between the heater and the first inner 45 elbow (FLFTWKIT) should be as long as the installation allows, and at least 900mm. Minimum Clearance 500 mm 1. Connect an inner 45 elbow onto the unswaged end of an inner flue pipe and join with three galvanised screws or rivets. 2. Slide lower outer 45 elbow over the inner 45 elbow and connect to outer flue pipe or. 3. Carefully fit the internal wall plate over the end of the lower outer 45 elbow. 4. Slide inner extension pipe through the lower outer 45 elbow and connect to the inner 45 elbow. Ensure a positive connection at this joint as it will not be possible to access for fastening by screws or rivets. 5. Fit and secure the spacer clamp to the inner extension pipe at approximately the mid way point of the pipe. 6. Slide outer extension pipe over the inner extension pipe and connect to the lower outer 45 elbow. The inner / outer extension pipes and may be cut to size to shorten penetration. 7. Slide the transition slip joint over the outer extension pipe 8. Slide the outer transition / wall plate over the transition slip joint. Seal and secure to the external wall. 9. Connect the second inner 45 elbow onto the un-swaged end of to the inner extension pipe and join with three galvanised screws or rivets. 10. Slide upper outer 45 elbow over the second inner 45 elbow and connect to the outer transition / wall plate 11. Continue assembly to the heater and flue terminal as per the Direct Rigid Flueing instructions on page 4. For longer external runs use FLFEXT03 external pipe lengths see note on page 6. 12. Carefully move the internal wall plate into position and secure to the internal wall with the 4 screws provided. M Q M Q V V U S U R T TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm O M Typical Inbuilt Installation S T Zero Clearance Box R TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm N P FLAMEFIRE FS35 / FS35ETR Minimum Clearance 500 mm O See Note See Note N FLAMEFIRE IB35 / IB35ETR M P B D B D Rinnai 7 Installation Manual

The Rinnai Flamefire Heater Family T INFORMATION Inbuilt Royale IB35 / IB35ETR Freestanding Royale FS35 / FS35ETR Inbuilt Slimfire 252 / 25 RIBF2 / IB25 Inbuilt Reflection IB300 Freestanding Sapphire RIB2310 Inbuilt Sapphire RIB2310 Head Office 10-11 Walker Street, Braeside, Victoria 3195 P.O. Box 460 Tel: (03) 9271 6625 Fax: (03) 9271 6622 Australia Pty. Ltd. ABN 74 005 138 769 Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au National Help Lines Spare Parts & Technical Info Tel: 1300 366 388* Fax: 1300 300 141* *Cost of a local call Higher from mobile or public phones. 15401084 8 RA 04 110 FLF RIGIDFLUEINST Issue 4 110712