TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Similar documents
Wireless High Voltage Digital Thermostat

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

ZIGBEE COMMUNICATING THERMOSTAT

RCS Residential Control Systems Inc.

Safety & Installation Instructions

Safety & Installation Instructions

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

T-32-TS Touchscreen Thermostat. Installation Manual

Safety & Installation Instructions

RCS Residential Control Systems Inc.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

INSTALLATION INSTRUCTIONS

Detailed Installer Guide

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Schneider Electric Erie T155 Series

INSTALLATION, OPERATION & QUICK START GUIDE

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Safety & Installation Instructions

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installation Manual for Hot Yoga Studio Electric Radiant Heating

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Comfort System T-21-P Touchscreen Thermostat Installation Manual

PRO Installation. Thermostat Wi-Fi

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Installation Instructions

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Commercial Touchscreen Thermostat

W1/B, O, W2/E, Y1, Y2, G. Gas or electric. Wireless, 915MHz, proprietary protocol. Up to 100 feet 24VAC, 2.4VA. Molded plastic

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

PerFormance Pro t4900 school series InstallatIon GUIDe

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Omnistat3 Hospitality Energy Management Thermostat

Installer Guide. WARNING Important Safety Information. 1 Specifications

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training

GETTING STARTED WITH SMART THERMOSTAT

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Networkable Fan Coil Controller Specification and Installation Instructions

Powerley Thermostat. Installation & Operation Guide

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

Control4 Wireless Thermostat by Aprilaire. Safety and Installation Guide

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

Detailed Installer Guide

Emerson Blue Easy Set 1H/1C

Model number is located on back of thermostat.

Install Guide CT100. Caution. Caution

Smart Temp. Model

Universal Programmable Smart Wi-Fi Thermostat Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control*

LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

Crestron CHV-TSTATEX infinet EX Thermostat Operations & Installation Guide

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

CT1001/CT1002 Touchscreen Programmable Thermostat

Operation and Maintenance Manual OM 897-3

T7200D,E Series 2000 Commercial Microelectronic Thermostats

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

SMART BATTERY POWERED Z-WAVE THERMOSTAT

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Programmable Thermostat

PerFormance Pro t12000 series InstallatIon GUIDe

WARNING Important Safety Information

Models: 1F95U-42WF, ST75 Version: October Sensi TM. Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE

Installation and Setup Guide

LOW VOLTAGE CONTROL CIRCUIT WIRING

Operator: SaVe these instructions forfuture use

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Two-Position Electric Duplex Room Thermostats

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

EL-TSTAT-8820 Safety & Installation Instructions

Fan Coil Unit (FCU) Application Guide

ZTS-500US Z-Wave Smart Thermostat

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

OWNER S MANUAL Venstar Inc. 08/07

PRO Installation. Touch Wi-Fi Thermostat

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

VisionPRO 8000 with RedLINK

1F98EZ-1421, Easy Install

1F Non-Programmable 5/1/1 Day 7 Day

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

ELECTRONIC COMMUNICATING THERMOSTAT

TOTALINE WALL THERMOSTATS

Description Model(s) Page(s) Description Model(s) Page(s) Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

SAS6000UTK-7 UNIVERSAL THERMOSTAT

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Transcription:

CD-TB200-01 TB-200 Product Battery Powered Thermostat Description The Evolve Wireless Digital Thermostat/Temperature Sensor is designed to control the majority of HVAC systems when used in conjunction with the RPTAC-5. This device is battery operated and includes a 128 x 64 backlit graphical display and a 6 button keypad with on screen labels. The Battery Operated Thermostat contains a robust interface and is designed for use with communicating systems where remote monitoring and/or remote control are desired. The Thermostat interface includes heating and cooling display, system mode, fan mode display and control and fan cycler amongst other features. The device can be wall mounted or mounted on a single-gang junction box. This Battery Operated Thermostat is designed to work with other Evolve enabled devices. Specifications SKU: TB-200 Supported Networks: - Z-Wave Signal (Frequency) 908.42 MHz Power: (4) AA Batteries (no wiring needed) Dimensions: 4.5 H x 5.75 W x 1 D Weight: 0.51 lbs. Available in Glass only Wiring Between the TB-200 and the RPTAC-5 No wiring needed. All communication is done via RF.

CD-T100H-01 T-100-H Product Wireless Digital Thermostat Description The Evolve Wireless Digital Thermostat is designed to control the majority of HVAC systems with its all-in-one design including a 128 x 64 backlit graphical display and 6 button keypad with on screen labels. The Wireless Thermostat contains a robust interface and is designed for use with communicating systems where remote monitoring and/or remote control are desired. The Thermostat interface includes heating and cooling display, system mode, fan mode display and control and fan cycler amongst other features. The device can be wall mounted on a single-gang junction box and requires both 24VAC (R) and 24VAC (C) wires from the HVAC System for power. This Wireless Digital Thermostat is designed to work with other Evolve enabled devices. Evolve nodes of other types can be included in the network and will also act as repeaters to increase the range of the network. Specifications SKU: T-100-H Supported Networks: - Z-Wave Signal (Frequency) 908.42 MHz Power: 24 VAC, Wiring 18 AWG Dimensions: 4.5 H x 5.125 W x 1 D Weight: 0.51 lbs. Available in Glass or Matte finish Wiring The device uses standard thermostat connections: C, R, W1, W2, Y1, Y2, G. The use of each of these terminals vary by application. The most common applications are outlined below; for applications not found on this list, please contact Evolve Technical Support at support@ evolvecontrols.com for more detail.

CD-T100H-01 Wiring Cont d HVAC Type: Hotel 3 Speed HVAC System Wiring Voltage: 24VAC Single Transformer Systems * Heat Pump diagram on next page. Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat board. Cut RC/RH jumper JP1 for separate heating and cooling transformers Cooling 24V Fan Low 24RC G 24C 24RH 24V Com 24V Heating Compressor Y1 W1 Heating Fan High Y2 W2/O Fan Med Remote Sensor 2 RS2 RS1 Remote Sensor 1 Remote Sensor 2 RS2 RS1 Remote Sensor 1 Sensor Shield RSC RSC Sensor Shield NU HC H1 NU Hotel HVAC System Thermostat Connection C 24VAC Common R 24VAC Return Heat Compressor Fan Low Fan Med Fan High

CD-T100H-01 Wiring Cont d HVAC Type: Hotel Heat Pump HVAC System Wiring Voltage: 24VAC Single Transformer Systems Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat board. Cut RC/RH jumper JP1 for separate heating and cooling transformers Cooling 24V Fan Low 24RC G 24C 24RH 24V Com 24V Heating Compressor Y1 W1 Aux Heat Fan High Y2 W2/O Change over valve* Remote Sensor 2 RS2 RS1 Remote Sensor 1 Remote Sensor 2 RS2 RS1 Remote Sensor 1 Sensor Shield RSC RSC Sensor Shield NU HC H1 NU Heat Pump HVAC System THERMOSTAT CONNECTION C 24VAC Common R 24VAC Return W Electric Heat O Change Over Valve* Y Compressor G Low Fan High Fan * Reversing Valve

CD-T100H-01 Wiring Cont d System Type Selection in the Installer Setup Menu System Type Fan Coil A Fan Coil B Heat Pump A Heat Pump B Fan Speeds 3 speed 2 speed 1 speed 2 speed Heat Stages 1 1 3 2 Cool Stages 1 2 2 1 Terminal Output Output Output Output C 24VAC C 24VAC C 24VAC C 24VAC C RH 24VAC R 24VAC R 24VAC R 24VAC R RC nu nu nu nu W1 Heat valve Heat valve Aux Elect Ht Aux Elect Ht W2/O Fan 2 Fan 2 Changeover Changeover G Fan 1 Fan 1 Fan 1 Fan 1 Y1 Cool Valve 1 Cool Valve 1 Comp stg 1 Comp stg 1 Y2 Fan 3 Cool stg 2 Comp stg 2 Fan 2

CD-T1500-01 T-1500 Product Wireless High Voltage Digital Thermostat Description The Evolve Wireless Digital Thermostat is designed to control the majority of HVAC systems with its all-in-one design including a 128 x 64 backlit graphical display and 6 button keypad with on screen labels. What makes this device different then the T-100-H is purely higher voltage. The Wireless Thermostat contains a robust interface and is designed for use with communicating systems where remote monitoring and/or remote control are desired. The Thermostat interface includes heating and cooling display, system mode, fan mode display and control and fan cycler amongst other features. The device can be wall mounted or mounted on a single-gang junction box. This Wireless Digital Thermostat is designed to work with other Evolve enabled devices. Evolve nodes of other types can be included in the network and will also act as repeaters to increase the range of the network. Specifications SKU: T-1500 Supported Networks: - Z-Wave Signal (Frequency) 908.42 MHz Power: 110 VAC 277 VAC, Wiring 18 AWG Dimensions: 4.5 H x 5.75 W x 1 D Weight: 0.51 lbs. Available in Glass or Matte finish Load rating: 2 Amps max heat/cool, 1/6 HP fan Relay Contact Rating: - 120 VAC, 10A - 240VAC, 10A - 277VAC, 8A Rated for pilot relay duty only Wiring The device uses standard thermostat relay connections: The use of each of these terminals varies by application. The most common applications are outlined below; for those not found on this list, please contact Evolve Technical Support at support@evolvecontrols.com for more detail.

CD-T1500-01 Wiring Cont d Install the mounting bracket to the junction box with either 2 (single gang) or 4 screws (double gang). Mounting Bracket Standard Junction Box Screw: 6/32 x 3/4 Fan Coil: Black = power White = Neutral Red = heating Brown = only used in a 3 speed system, this wire represents MEDIUM fan Blue = cooling Orange = only used in a 2 or 3 speed system, this wire represents HIGH fan Yellow = LOW fan. Note: in a 1 speed system, the wire is the default only fan terminal used Black 4-pipe Fan Coil HVAC System 3 Speed Fan Line Red HEAT Blue COOL Yellow LOW 120VAC - 277VAC Brown MED Orange HIGH Fan Cool Valve Heat Valve White Black 4-pipe Fan Coil HVAC System 2 Speed Fan Neutral Line Red HEAT Blue COOL Yellow LOW 120VAC - 277VAC Brown MED Orange NOT USED Fan Cool Valve Heat Valve White Neutral

CD-T1500-01 Wiring Cont d Connect the thermostat wires to the cable wires using appropriate sized wire nuts. Push the wires into the junction box. Tilt the thermostat so that the top of the thermostat is resting on the mounting tabs of the mounting plate. Push the bottom of the thermostat towards the wall and secure in place with the self-tapping screws as shown to the right. Standard Junction Box Turn power back on. LCD should display temperature and thermostat functions.

TC-500 Thermostat DESCRIPTION The Evolve Controls Thermostat is designed to control the majority of HVAC systems with its all-in-one design including a 4.3, Backlit LCD Display with Integrated In-Cell Touchscreen. The Wireless Thermostat contains a robust interface and is designed for use with communicating systems where remote monitoring and/or remote control are desired. The Thermostat interface includes heating and cooling display, system mode, fan mode display and control and fan cycler amongst other features. The device can be wall mounted on a single-gang junction box and requires both 24VAC (R) and 24VAC (C) wires from the HVAC System for power. This Digital Thermostat is designed to work with other Evolve Controls enabled devices. Evolve Control nodes of other types can be included in the network and will also act as repeaters to increase the range of the network. FEATURES 4.3, backlit LCD display with integrated In-Cell touchscreen Ambient temperature Onscreen set point, operation and fan mode controls Degrees Fahrenheit or Celsius modes Monitors, displays and reports relative humidity Remote control of thermostat functions Z-Wave compatible Optional remote Z-Wave and wired sensors

TC-500 SPECIFICATIONS SKU: TC-500 Supported networks: Z-Wave ( 500 series chip ) Signal (Frequency) 908.42 MHz Wireless Communication Range: up to 130ft (40m) indoors Uses standard thermostat connections Central HVAC systems or seperate heating/cooling systems Heat Pump HVAC systems : 3-stage heating, 2-stage cooling Standard gas/electric HVAC Systems : 2-stage heating, 2-stage cooling Fan system : Selectable for gas or electric heat systems and supports Fan Cycler feature Emergency Heat: In Heat pump mode, Emergency Heat mode is directy selectable from the thermostat Automatic heating and cooling changeover Z-Wave Network INSTALLATION 11:48PM Humidity - 45% 76 C R G W1 W2/O Y1 Y2 HVAC System Copyright 2018. Evolve Guest Controls, LLC. All Rights Reserved. Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries.