PART NO. COMBUSTION AIR CAP

Similar documents
PART NO. COMBUSTION AIR TERMINATION CAP

PART NO. THROUGH THE ROOF VENT CAP

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

INFRARED RADIANT TUBE HEATER

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

A. Product Data: Include rated capacities, furnished specialties and accessories.

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

48TM GAS HEATING/ELECTRIC COOLING UNITS

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

SHP High Pressure Radiant Gas Brooder Series

FX5 Series Explosion-Proof Electric Air Heaters

INFRARED RADIANT HEATERS

ULTRA-SAFE Explosion-proof Duct Heaters

IS Series Pressure Sensing Switches

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

Heating Controls Technical

Direct Fired Heater Model AD Specification

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Evaporative Cooling Controls... 1F51 / 8A18Z / 21D Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

DIVISION FINNED WATER-TUBE BOILERS

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Control and power circuit fusing to meet N.E.C.

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

DIVISION FINNED WATER-TUBE BOILERS

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

Centro-Matic Automated Lubrication Systems System Controls

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

ULTRA-SAFE Explosion-proof Duct Heaters

AFUE 95% Heating Input 50,000 to 200,000 Btuh

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

TEMPERATURE & PRESSURE CONTROLS

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)


Ultra-Safe EXP Unit Heater

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Cabinet Unit Heaters Steam / Hot Water

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER

Innovation. Simplicity

A19, A28 Series Thermostats for Agricultural Buildings

DIVISION FINNED WATER-TUBE BOILERS

50TM COMBINATION HEATING/COOLING UNITS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Heating Products M arch 2012

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Two-Position Electric Duplex Room Thermostats

FEATURES AND BENEFITS

Thermostats Zoning Systems

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

THERMOSTATS THERMOSTATS HEATING AND COOLING

U n i t H e at e r s

KIC Air Curtains. Technical Guide

SUBMITTAL SCHEDULE & DATA

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Copyright 2011 AIA MasterSpec Full Length 06/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CALCANA USA LTD.

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

User s Manual

SECTION LIGHTING CONTROLS

Smart Products. Ingenious Solutions.

A11 Series Low Temperature Cutout Controls

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

50TM TFF COMBINATION HEATING/COOLING UNITS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

SECTION AIR DOORS

SECTION (15767) - UNIT HEATERS

WATER-TUBE POOL HEATERS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Indirect Gas-Fired Make-Up Air

SECTION HEATING BOILERS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Preparation Table Raised Condiment Rail models 8000N

WATER-TUBE POOL HEATERS

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Innovation. Simplicity

Tankless Water Heaters

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Greater temperature control

Custom Duct Heaters. Special Applications

Transcription:

ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction Heavy-gauge aluminum construction Riveted at all major stress points for durability and service Fits type B flue pipe. Can be used for sidewall venting as well as thru the roof venting C FITS PIPE DIMENSIONS A B C WEIGHT (ea.) 30297040 4 8-1/2 8-1/4 4 1-1/2 lbs. 30297060 6 10-1/2 9-1/4 6 4 lbs. 30297080 8 12-1/2 12-3/4 8 6 lbs. COMBUSTION AIR CAP Heavy gauge aluminum construction Eliminates downward draft Fits type B or single wall flue pipe Fresh air (combustion air) duct termination. A MODEL DIMENSIONS A B C WEIGHT (ea.) 41000020 3050 6-3/4 4-1/4 4 1.5 lbs. C B.023.017 41000000 5070 9-1/2 5 6 3 lbs. 41000010 7090 12 7 8 5 lbs. EXHAUST HOOD Used for indirect vented applications Directs the heat away from the draft inducer Includes bird screen Heavy gauge aluminized steel construction. 7½ 6 3¾ MODEL NO. WEIGHT (ea.) 3½ CB, LTS/U, and ETS/U 42924000 5 lbs. 4 (Side View) (Front View) RSTP15 and RSTP17 * 42406000 7 lbs. * Dimensions not shown 1

LINE REGULATORS Up To 2 psig Durable, corrosion-resistant construction Equipped with 12A09 Vent Limiting Device In the event of diaphragm rupture, gas escapement is limited to a non-hazardous level Must be installed on a horizontal plane. USE MODEL FOR HEATERS UP TO 140,000 BTU/HR FOR HEATERS 150,000 TO 220,000 BTU/HR FOR HEATERS 225,000 BTU/HR AND ABOVE PIPE CONNECTIONS MAXIMUM INLET OUTLET WEIGHT (each) 325-3L 03307260 1/2 x 1/2 2 psig 7 W.C. 2 lbs. 325-5L 03307310 1/2 x 1/2 2 psig 7 W.C. 2 lbs. 325-5L 03307270 3/4 x 3/4 2 psig 7 W.C. 2 lbs. LINE REGULATORS Above 2 psig Heavy-duty construction High Capacity Internal Relief Inlet and Outlet Pressure Taps for easy system checks Must be vented to the outside. MODEL PIPE CONNECTIONS MAXIMUM INLET OUTLET WEIGHT (each) 03483070 R622-BCF 1/2 x 1/2 10 psig 11 W.C. 3 lbs. FLEXIBLE CONNECTOR CSA Listed stainless steel gas connector. Included with all Tube Heaters. USE LENGTH I.D. FOR HEATERS UP TO 225,000 BTU/HR FOR HEATERS 225,000 BTU/HR AND ABOVE WEIGHT (each) 30302360 36 1/2 1 lb. 30302361 36 3/4 2 lbs. RT SERIES Line Voltage Thermostat Part #30348970 Temperature range 50ºF to 90ºF with ± 4ºF differential 22 amp full load Capable of controlling up to 7 Space-Ray infrared tube heaters Economically priced Durable, bi-metallic heat sensing element Simple connections with easy-to-reach wiring terminals Easy to mount, fits flat on wall with one-inch recess in wiring box. 2

HEAVY DUTY Line Voltage Thermostat Part #03209000 Temperature range 35ºF to 95ºF with ± 2ºF differential 16 amp full load Capable of controlling up to 6 Space-Ray infrared tube heaters Sealed, dust protected SPDT switch Liquid-filled sensing element, specially treated against corrosion and firmly attached to top of thermostat, provides uniform control at ambient temperatures Dependable single-pole, double-throw snap acting contacts in steel, dust-tight, NEMA 1 enclosure Close differential for critical requirements Adjustable cutout stop. GENERAL DUTY /HIGH HUMIDITY ENVIRONMENT Line Voltage Thermostat Part #30525010 Temperature range 40ºF to 104ºF with ± 2.5ºF differential 16 amp full load Capable of controlling up to 6 Space-Ray infrared tube heaters Recommended for general duty and high humidity environments such as car washes, agricultural buildings, and water treatment plants Quality constructed thermostat designed for use in harsh environments Watertight ABS plastic meets NEMA 4x and NEC Article 547-4 requirements Responsive, durable, 316 stainless steel, sidemounted sensing coil Adjustable dial allows thermostat to be recalibrated Single SPDT switch. 24 VOLT THERMOSTAT Part #30562000 Temperature Range 50ºF to 90ºF with ± 4ºF differential Adjustable Heat Anticipator 24 volts 0.1 to 1.0 Amps Individual Heater Operation Requires Relay Kit Hermetically sealed Reed Switch operated by a magnet attached to coiled bimetal Snap-action operation makes precise leveling of the thermostat unnecessary Universal mounting vertical and horizontal faceplates included Use with 24-Volt Thermostat Relay Kit (Part #43274000 for LTU40-75 & CB20-50 or Part #43274010 for LTU80-250, LTS40-250 & ETS/U40-250) to control one Space-Ray infrared tube heater. PTS/U Series can be externally connected with a single 24V Thermostat and do not require a 24-Volt Thermostat Relay Kit 3

SETBACK 3000 THERMOSTAT Part #43240030 Digital Programmable 24-Volt thermostat N5 or L5 Control Capable of controlling up to 5 Space-Ray infrared tube heaters Fan center relay shipped separately Temperature Range 45ºF and 90ºF with ±1ºF differential 4 different program periods per day w/ 7 day programming Temporary Temperature override Battery Back-up Supplied with Heavy Duty Self-contained Locked Cabinet & Enclosure SETBACK 5000 THERMOSTAT Part #43240050 Digital Programmable Line Voltage thermostat N5 or L5 Control Capable of controlling up to 6 Space-Ray infrared tube heaters Temperature Range 45ºF and 90ºF with ±1ºF differential 4 different program periods per day with 5/2 day programming Temporary Temperature override Battery Back-up Supplied with Heavy Duty Self-contained Locked Cabinet & Enclosure. TWO STAGE DIGITAL SETBACK THERMOSTAT Part #30644100 For modulating two stage heaters- N7 or L7 Control 24V Digital Night Setback Thermostat with Large hybrid dot matrix display Temperature Range 40ºF and 90ºF with ±1ºF differential 7 day programming & 4 periods per day with Night Setback function ENERGY STAR Compliant Temporary override, Hold & Vacation hold Optional smart recovery Advanced copy function for fast easy programming Temperature offset (user calibration) Programmable length minimum run time Multi-stage adjustable temperature differential/cycle rate ± 2.25ºF differential Dual power capable (system/battery) Daylight savings button Multimode keyboard lockout with user programmable 3 Digit Code TWO STAGE ECONOMY THERMOSTAT - Part #30348100 For modulating two stage heaters- N7 or L7 Control Temperature Range 50ºF and 90ºF with ± 4ºF differential 24V Mechanical Thermostat Bi-Metallic heat sensing element Easy to mount, fits flat with one-inch recess in wiring box Non adjustable differential Economically priced. To be used when a mechanical thermostat is specified 4

24V Thermostat Relay Kit To control one Space-Ray infrared tube heater with a 24V Thermostat. 43274000 for LTU40-75 & CB20-50 43274010 for LTU80-250, LTS40-250 & ETS/U40-250 PTS/U Series can be externally connected with a single 24V Thermostat and do not require a 24V thermostat Relay Kit Two Stage Thermostat Relay Kit Part# 44195000 Required when controlling multiple Two Stage heaters (N7 / L7 Controls) with a single 24V Two Stage Thermostat. One relay kit per heater required. Supplied with ABS Enclosure and mounted externally. Thermostat Enclosure Part# 43244010 Heavy Duty metal thermostat enclosure - tamperproof Hinged access door with locking cover Can be used with any thermostat except Part #30525010 Prevents direct radiant energy affecting the thermostat sensor. Enclosure dimensions 9 ½ X 5 ½ 4 CHAIN KITS 41690250 Chain Kit 25 ft. chain with 12 S-hooks 41690350 Chain Kit 35 ft. chain with 12 S-hooks (50' straight heaters) 41690500 Chain Kit 50 ft. chain with 12 S-hooks (80' straight heaters) 41690120 Chain Kit for CB Series, 12 ft. chain with 8 S-hooks MANUAL CUTOFF VALVES 30285000 CSA listed ball valve, ½" NPT 30285020 CSA listed ball valve, ¾" NPT, for heaters 225,000 Btu/hr and above 5

Manual (On/Off) Toggle Switch Part #40147000 Single Pole Single Throw 20A/125V 12A/250V Single Galvanized Gang Box (2 X4 X2-1/8) Galvanized Face Plate w/ Screws 60 Minute Auto Shut-Off Timer Part #30574000 Timer Dial Face Type Mechanical Up to 60 Minute Capable 120V SPST (Single Pole Single Throw) Breaks Circuit at End of Timing Cycle Spring Loaded Replaces Any Single Gang Switch Three Position Switch Kit Part# 40147010 High /Low /Off Control of two stage heatersf ABS Plastic Enclosure NEMA 4X Rated Enclosure dimensions 4.3 X 3.1 X 2.6 Deep SPACE-RAY P.O. Box 36485 Charlotte, NC 28236 Phone (704) 372-3485 Fax (704) 332-5843 Toll Free (800) 438-4936 www.spaceray.com info@spaceray.com 6