Test Drive Technologies Vehicle Inspection Appraisal Services 19424 Ellwood Road Breese, IL. 62230 636-388-8378 / 618-960-4696 steve@testdrivetech.com CHASSIS IDENTIFICATION COACH IDENTIFICATION VEHICLE DATA INFORMATION Chassis Vehicle Identification Number 4UZFCTFG2JCJD9867 Coach Vehicle Identification Number 4UZFCTFG2JCJD9867 Chassis Manufacture NEWMAR / FREIGHTLINER Chassis Year 2018 Chassis Model ESSEX Inspection Sticker Date Registration Date GVW / CCC Information 54,000 LBS Mileage Shown 8,058 Engine Manufacture CUMMINS Engine Model X15 Transmission Manufacture ALLISON Transmission Model Axle Manufacture EATON Axle Model Suspension Type AIR RIDE BAG Brake Type AIR BRAKES Leveling System Type HYDRAULIC / AUTO MOTORHOME CHASSIS Condition of Cockpit Dashboard Gauge Cluster Gauges Respond to Self-Test Warning Lights Cockpit Entertainment / Controls (CURRENTLY BEING REPAIRED) MULTIPLE FAULT CODES IN DIAGSTIC SYSTEM TOUCHSCREEN HAS A FIST SIZE AREA IN CENTER OF SCREEN WHICH IS IPERABLE - MECHANIC SAID IT IS ON ORDER AND BEING REPLACED Page 1 of 10
ENGINE COMPARTMENT Engine Cleanliness Hoses Belts Radiator Fans Oil Level Oil Condition Leakage CLEAN FULL PENDING ALYSIS RESULTS NE TRANSMISSION / DRIVELINE Transmission Cleanliness Lines Hoses Transmission Cooler Fluid Level Fluid Condition Leakage CLEAN FULL PENDING ALYSIS RESULTS NE EXHAUST SYSTEM Exhaust Condition Pipes Converter Muffler Brackets Leakage NE EXTERIOR - CHASSIS / FRAME Frame & Components Frame Type Frame Condition Axles, Springs, Shocks & Hanger Components Wheels / Tires & Rims - Type Wheels / Tires & Rims - Condition Brake Type Brake Condition Spare Tire & Mounting Rack Leveling / Stabilization System Type Leveling / Stabilization System Operation Hitch & Pin Box Equipment Chains & Break Away Switch Operation ALL PRESENT CONVENTIOL AIR BRAKES HYDRAULIC Page 2 of 10
EXTERIOR COMPONENTS Roof Type General Condition of the Roof Joints & Seals Vents Vent Covers Plumbing Vents Air Conditioning Covers & Exterior Coils Ladder Satellite Antenna Radio Antenna Refrigerator Vent Skylights Air Horns Spot Lights Solar Panels Signs of Equipment Removed FIBERGLASS IN GENERATOR COMPARTMENT SIDE WALLS Front Type of Construction Street Side Type of Construction Curb Side Type of Construction Rear Type of Construction Decals & Paint Corner Joints, Trim & Gutters FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS DOORS Entrance Doors Condition of Doors Screens Decals & Trim Latch & Lock Systems MAIN DOOR CURBSIDE / EMERG EXIT REAR DOOR (EMERG DOOR DOES T DEAD BOLT, LOOKS LIKE PLASTIC RING IS CATCHING LATCH) WINDOWS Type of Windows SLIDE Count of Windows 10+ Condition of Windows Emergency Windows Seals & Gaskets Window Screens PRESENT STORAGE Storage Compartments 6 Page 3 of 10
Door & Interior Compartment Conditions Door Lock Types Seals & Waterproofing Area Around Compartment Condition Operation of Doors & Locks Hinges & Gas Cylinders Slide-Out Trays & Shelves Flooring & Interior Walls of Compartments Compartment Lights POWER LOCKS (ENG COMPARTMENT GAS CYLINDERS DO T HOLD HOOD OPEN FULLY) (ELECTRIC PANEL LIGHT BULB IP) AWNINGS Number of Awnings 1 Type of Awnings POWER - ROLL UP - SELF STORAGE Sizes of Awnings 25 FT Fabric & Condition Manual or Electric Operation POWER Hardware & Locks Condition SLIDE OUT TOPPER AWNINGS Number of Slideout Awnings 3 Type of Slideout Awnings FABRIC Sizes of Slideout Awnings 30 FT / 20 FT / 6 FT Fabric & Condition Manual or Electric Operation POWER Hardware & Locks Condition WINDOW AWNINGS Number of Window Awnings 4 Type of Window Awnings FABRIC Sizes of Window Awnings MULTIPLE Fabric & Condition Manual or Electric Operation POWER Hardware & Locks Condition SLIDE OUT(S) Number of Slideouts 3 Type of Drive - Hydraulic, Electric, Cable or Schwentke HYDRAULIC POWERED / CHAIN DRIVEN Mechanical Operation of Slide System Condition of Seals Tracking / Rack System Type CHAIN SYSTEM Tracking / Rack System Condition Override Operation Feature OPERATIOL Misc. Trim & Decals of Slides Page 4 of 10
STEPS Type of Steps - Manual / Electric Condition & Operation of Steps Non-Skid Strips Grab Handles HYDRAULIC STEPS STOP ABOUT 1/3 OF THE WAY OUT AND TURN OFF THE PUMP AS IF THEY ARE APPROACHING THE PROXIMITY SWITCH. THEY DO END UP GOING OUT ALL THE WAY IF YOU USE THE MANUAL OVERRIDE BUTTON INSIDE THE DOOR CHASSIS LIGHTS Lighting Type Turn Signals Marker Lights Brake Lights Clearance Lights Docking Lights Reverse Lights Tongue / Hitch Lights LED OPERATIOL - D/S SIDE TURN LAMP IP OPERATIOL OPERATIOL OPERATIOL OPERATIOL OPERATIOL OPERATIOL CHASSIS VOLTAGE SYSTEM (12 VOLT DC) Visual Condition of Batteries Visual Condition of Cables & Connectors Disconnect Switch & Battery Watering System Manual Voltage Reading 13.49 VOLTS MISC. ELECTRICAL SYSTEM Cable TV Hook Up Satellite TV Hook Up Wireless Internet COACH VOLTAGE SYSTEM (12 VOLT DEEP CYCLE) Visual Condition of Batteries Visual Condition of Cables & Connectors Disconnect Switch & Watering System Manual Voltage Reading Converter Operation Interior Lights Interior Fans Exterior Porch & Security Lights Antenna Signal Booster 13.53 VOLTS HOUSE / SHORE / PEDESTAL POWER (120 VOLT AC) Visual Inspection of Power Cord Verify Power from Outlet / Pedestal Perform Hot Skin Test CLEAR Page 5 of 10
Inspect Interior of Breaker Panel Box - Beakers & Wiring Operation of GFCI Circuits Polarity of all Wall Receptacles Operation of Ceiling Fans Operation of 120 Volt Lights INVERTER SYSTEM Type of Inverter Operation of Inverter Cables, Wiring & Fuses Verify Operation of Inverter w/ Load 3000-WATT INVERTER GENERATOR Type of Generator Starting of Generator Fuel Prime Switch Operation Oil Level & Condition Filter Condition Coolant Level & Condition Circuit Breaker Operation Verify Generator Operation w/ Load DIESEL PLUMBING (CITY WATER) City Hook Up Condition Verify Inline Check Valve Inspect Inline Water Filter Bathroom Faucets Shower Fixtures Shower Doors, Racks & Other Hardware Kitchen Faucets Toilet Operation T INSTALLED PLUMBING - ON DEMAND / ONBOARD WATER Verify Tank Holds Water Test Water Pump Operation for Pressure Does Water System Hold Pressure Do All Water Fixtures Function Any Leaks Under Pressure Verify Operational of Exterior Shower Verify Exterior Sink Verify Caps on Lowest Water Point Exterior Valves Condition VERIFIED PLUMBING - BLACK WATER WASTE SYSTEM Valve & Handle Operation Check Sealing of Valve Page 6 of 10
Tank Wash System Operation Toilet Flapper Seal Holding Water PLUMBING - GRAY WATER WASTE SYSTEM Valve & Handle Operation Check Sealing of Valve PROPANE SYSTEM Inspect Condition of ASME Tank or Cylinder(s) Date of DOT Cylinders High Pressure Hose & Fittings Condition Inspect Regulator, Cover & Positioning Verify Inline Regulator on Split DOT Cylinders Perform Leak Test - 8" W.C. for 3-5 Min REFRIGERATOR Make / Model Serial Number Operation on LP Operation on Electric Operation on Auto Doors Latch & Seal Correctly Maintain Temp Range Recall Kit Installed Condensation Line Drain Interior Light Function DOMETIC / WRF5605EYM05 VS62227284 41 DEG FRIDGE / 1 DEG FREEZER CLEAR WATER HEATER Water Heater Type ON-DEMAND Make / Model Serial Number 393131 Operation on LP Operation on Electric Operation on Auto By Pass Valve Operation Anode Rod Condition (Requires Owner Approval & Tools) Tank Sludge Dauber Screens Installed FURCE Furnace Type HYDRO HEAT Make / Model OASIS / 34900 Serial Number CH50M-1226-6847 Operation on LP Operation on Electric Operation on Auto Page 7 of 10
General Condition of Unit Furnace Operation Dauber Screens Installed COOK TOP / STOVE Stove Type Make / Model Serial Number General Condition of Unit Oven Burner Light Top Burners Light Exhaust Fan (Vent Hood) Operation ELECTRIC INDUCTION TRUE INDUCTION UBLE TO LOCATE DATA STICKER NEW INDUCTION PANS TO TEST WITH AIR CONDITIONER(S) Make / Model of Air Conditioner(s) DOMETIC PENGUIN / 651816H751C0 Serial Number of AC(s) 60428091 / 638208190 / 638208181 Ducted / Non-Ducted DUCTED Thermostat Control / Manual Control THERMOSTAT Filter Condition Plenum Divided & Sealed Temperature at Each Unit 45 DEGREES ON AC / 92 DEGREES ON HEAT MICROWAVE Make / Model of Microwave Serial Number of Microwave General Condition of Unit Heats Cup of Water Turn Table & Components in Microwave GE / DSA9120SF355 V6200181K, TO BOIL WASHER / DRYER Make / Model of Washer Serial Number of Washer Operation of Washer Make / Model of Dryer Serial Number of Dryer Operation of Dryer WHIRLPOOL / WFW30906W WHIRLPOOL / CF63006283 CEILING CONDITION & APPEARANCE Ceiling Skylights Discoloration, Damage or Stains Roof Vent Operation Light Switches Light Fixtures (LAMP TO THE LEFT OF COUNTER TV IS DIM) Page 8 of 10
WALL CONDITION & APPEARANCE Walls Discoloration, Damage or Stains Repairs Performed Window Coverings / Shades FLOORS CONDITION & APPEARANCE Floors Carpet Condition Tile / Hard Flooring Condition Water Damage or Soft Spots Repairs Performed CABINETS CONDITION & APPEARANCE Cabinets Trim Work Doors Drawers Bookshelves Counter Top Sink Hardware & Latches Repairs Performed FURNITURE CONDITION & APPEARANCE Couches Chairs Bedding Fabrics Match Décor ENTERTAINMENT COMPONENTS Entertainment Components List MFG / Model Serial Number Do all Components Power On DVD, SAT, FRONT TV, CENTER TV, EXT TV SONY ALARMS & FIRE SAFETY Carbon Monoxide Alarm / CO Detector Liquid Propane Alarm / LP Detector Smoke Detector / Fire Alarm Fire Extinguisher TESTED AND WORKING PRESENT AND CHARGED ACCESSORIES & MISC. Accessories Backup Camera Page 9 of 10 OPERATIOL
Misc. INSPECTOR'S FIL TES CHASSIS AND COACH ARE BOTH IN EXCEPTIOL CONDITION. THERE ARE A FEW ITEMS THAT NEED TO BE ADDRESSED: CODES STORED IN DIAGSTIC SYSTEM NEED VERIFIED AND TROUBLESHOT BY FREIGHTLINER MFG. STEPS NEED CHECKED OUT WHY THEY DO T EXTEND ALL THE WAY OUT. TOUCHSCREEN NEEDS REPLACED. REAR DOOR LATCH NEEDS ADJUSTED / REPLACED. WALL LAMP NEAR TV NEEDS CHECKED FOR BEING TOO DIM. D/S SIDE TURN LAMP IP, NEEDS TROUBLESHOT. DOUBLE CHECK ALL LAMPS IN CARGO STORAGE FOR OPERATION. ENG COMPARTMENT CYLINDERS DO T HOLD HOOD OPEN FULLY. OIL SAMPLES TAKEN FROM ENGINE AND TRANSMISSION AND WERE SENT OUT FOR ALYSIS. INSPECTOR'S ME: STEVEN S. PAUL INSPECTOR'S CERTIFICATION: NRVIA# 1928 INSPECTOR'S SIGTURE: INSPECTION DISCLAIMER THIS INSPECTION HAS BEEN PERFORMED AT THE LOCATION OF THE VEHICLE WHETHER AT A PRIVATE SELLER, DEALERSHIP OR OWNER'S LOCATION. THE VEHICLE MAY OR MAY T HAVE BEEN LIFTED FOR ACCESS DEPENDING ON THE VEHICLE LOCATION, WEATHER CONDITION, GROUND CONDITION AND VEHICLE CONDITION, A TE WILL BE ADDED TO THE INSPECTOR'S COMMENTS. THE INFORMATION PROVIDED IN THIS REPORT IS ONLY A SPSHOT OF THE VEHICLE'S CONDITION ON THE SPECIFIC DAY OF INSPECTION AND DOES T PROVIDE ANY WARRANTIES OR GUARANTEES THEREAFTER. THERE WERE PARTS REMOVED USING TOOLS OF ANY KIND FOR THIS INSPECTION ALTHOUGH SPECIAL TESTING EQUIPMENT MAY OR MAY T HAVE BEEN USED TO DISCOVER THE CONDITION OF CERTAIN PARTS. EVERY EFFORT HAS BEEN MADE TO PROVIDE THE MOST THOROUGH AND ACCURATE INSPECTION POSSIBLE DURING THIS INSPECTION INCLUDING A TEST DRIVE. IF A TEST DRIVE WAS T PERFORMED A REASON IS INCLUDED IN THE INSPECTOR'S FIL TES INDICATING WHY IT WAS T. SOME POSSIBLE REASONS INCLUDE, LACK OF PROPER LICENSING OR INSURANCE DOCUMENTS, CONDITION OF THE VEHICLE, WEATHER, TRAFFIC CONDITIONS, SELLER T PRESENT OR SELLER DID T AUTHORIZE THE TEST DRIVE. IN SOME CASES, THE INSPECTOR WILL RIDE ALONG IN THE VEHICLE WHILE THE SELLER DRIVES, A TE WILL BE PROVIDED IN THE INSPECTOR'S TES INDICATING SUCH. Page 10 of 10