RIVERTRACE ENGINEERING LTD

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Bristol Babcock Oil Content Monitor "oil in water"

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

A New Standard of Excellence

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

APPLICATION DATA SHEET

Turbimax CUE21 / CUE22

continuous emissions monitoring Combustion & Environmental Monitoring

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

APPLICATION DATA SHEET

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Parker icount Oil Sampler (IOS)

Process Alarm Solutions

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

OPTISENS TUR 2000 Technical Datasheet

Honeywell SLATE ICM Platform

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Allure EC-Smart-Air Series Communicating sensors

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Danfoss gas detection unit Type GD Heavy Duty

gas monitoring system

Complete Boiler Management in a Compact, Affordable System

ZXSe Range Data Sheet

Zircomat Oxygen Analyzers

icount Oil Sampler (IOS)

Turbimax CUE21 / CUE22

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Industrial Grade Gas Detection

Technical Manual. Level Alarm Unit CARLA & WIDS

portable gas analyser

Danfoss gas detection units

Model D12-IR. Digital Gas Transmitter...

Maxline 2 Thermal Imaging Solutions for Manufacturing

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Substation Monitoring System

Advanced FireAlarm Panel 1-4Loop

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

HART XL High Sensitivity Smoke Detection

HFID Heated Total Hydrocarbon Analyzer Module

BORS - Bilge Oil Removal Systems

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

AS950 REFRIGERATED SAMPLERS

AUTROSAFE. An interactive fire detection system for larger vessels

Datalogging as standard

For Complete Fire and Gas Solutions

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

CN7232 Advanced Garage Ventilation Controller

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

SIMPLICITY BY DESIGN M52 CONTROLLER

Networked Access Control Panel. Installation Guide

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Advanced Integrated Ecological monitoring solutions & Process analysis for Marine Industry & Port Authorities

AS950 PORTABLE SAMPLERS

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

EL-USB-1-LCD Temperature Data Logger with LCD

EC3-X33 Stand-alone Superheat Controller Technical Data

Tankless On Demand Electric Water Heater

Fact Sheet TANK CONTENT AND DRAUGHT MEASURING SYSTEM Issue Date

Instrumentation and Controls Group

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Touchpoint Plus. A whole new control experience

GESTRA Steam Systems OR English. Installation Instructions Oil & Turbidity Detector OR 52-7

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Industrial Grade Gas Detection Detecting The Difference

for Drinking Water Systems

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Recalibrate the way you look at gas detection

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

HART XL High Sensitivity Smoke Detection

Architectural and Engineering Specification for a. Flash / Flare

Heatless Desiccant Compressed Air Dryers

Danfoss gas detection units

AZTECA A LITRE STERILISER

SECTION Fluorescent Dissolved Oxygen Measuring System

Triton Series High Efficiency Boiler

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Transcription:

marine Specialists in water quality monitoring www.rivertrace.com

INTRODUCTION Rivertrace is a market leader with over 30 years experience of Oil in Water Quality Monitoring. Rivertrace manufacture oil content monitors for the marine, offshore and industrial markets with up to date technological engineering solutions to meet strict regulatory requirements. Our impressive client list includes leading European, American and Asian separator manufacturers. We also supply most of the major International Shipping Companies together with the leading Offshore Oil and Gas Operators as well as Premier Land Based Industrial Organisations. We are dedicated to producing high quality products and service to meet oil in water monitoring solutions. Rivertrace are accredited to ISO 9001:2008 and employ around 28 people at our 10,000 sq. ft. factory in Redhill. Local sales, service and support is provided by our strong global network of agents. OUR SALES & SERVICE NETWORK

CONTENTS PAGE 2: PAGE 4: PAGE 6: PAGE 10: PAGE 12: PAGE 14: SMART CELL 15PPM OIL CONTENT MONITOR TO MEPC 107(49) SMART PFM 107 OIL-IN-WATER MONITOR SMARTSAFE ORB BILGE OVERBOARD SECURITY SYSTEM SMART ODME TO MEPC 108(49) SMART 50M OIL IN WATER MONITOR SMART TURBIDITY MONITOR marine 1

SMART CELL 15PPM OIL CONTENT APPLICATIONS Bilge Water Discharge Rig Slop Tank Discharge Air Cooler Drains Overboard Discharge Oily Water Separator Discharge By utilising the Smart Cell Detector Array Technology, developed by Rivertrace, the OCM analyses all three oil types (HFO, Diesel and Emulsions) simultaneously without the need for re-calibration. A manual cell cleaning device is included as standard to easily enable routine maintenance. Optical cell fouling is recognised as a leading cause of monitor malfunction or incorrect reading. By simple operation of the manual cleaning device, the Smart Cell remains in optimum operating condition. Replacement calibrated measuring cells can be purchased for easy change over on board the vessel and calibration verification kits enable the crew to demonstrate the monitor is within factory calibration to PSC Surveyors. The Smart Cell Bilge Alarm is readily available as a 5ppm version if required. It can also be tailor made for Hazardous Environments (Zone 1 & 2) as an Exd system with Auto Clean, all enclosed in an explosion proof cabinet. We also offer the system in an Anti- Magnetic version, ideal for submarines and minesweepers. OPTIONS > FLOWSWITCH > The flowswitch option has been designed to ensure that bilge water is flowing through the measuring cell when in monitoring mode. An error is shown on the display if there is no flow. The flowswitch monitors the flow of water through the cell. This ensures that the flow cannot be shut off accidently or maliciously. In case of no flow, the Smart Bilge will close the overboard discharge valve. AUTOCLEAN > The autoclean option has been designed to ensure that the measuring cell glasstube is kept free from fouling. Cell fouling is recognised as a leading cause of monitor malfunction. Fitting the Autoclean removes the need for the ship s crew to remember to clean the cell manually. All options can be ordered from new or retrofitted to existing RTE Smart Cell monitors. 5 ppm > available factory set 5 ppm calibration verification kits are also available www.rivertrace.com 2

MONITOR TO MEPC 107(49) Smart Cell SPECIFICATION MEASUREMENT Oil types: HFO, Diesel and Mixture C (IMO defined) Clean water calibration: +/- 2ppm of factory set values Oil range: 0-40 ppm Accuracy oil + solids: +/- 5ppm up to 30 ppm Solids discrimination: 100ppm Iron Oxide in 10 ppm Diesel Response time: < 5 sec (oil reading) ALARMS Oil alarm 1 setpoint: 1 15 ppm user adjustable Oil alarm 2 setpoint: 1 15 ppm user adjustable Oil alarm 1 delay: 0 5 seconds user adjustable Oil alarm 2 delay: 0 600 seconds user adjustable INPUT / OUTPUT Analogue output: Loop powered 4-20mA / 0-20mA 24V Switch inputs: 2 x switch inputs for separator and backflush status DATA STORAGE AND RETRIEVAL Calibration data storage: Stored in cell IMO required data: Stored in Control enclosure IMO required data retrieval: Via LCD display, RS 232 comms link or USB SYSTEM AND SUPPLY Supply voltage: 115 or 230V AC, 50 60Hz (24V AC & 12V DC available) Supply voltage Consumption: < 50 VA incl. solenoid valve Supply voltage tolerance: +/- 15% Projected life: > 50,000 hrs Protection class: IP 65 Approvals: MEPC 107(49) DNV-GL, USCG, CCS, Class NK, Russian Register, Transport Canada. Weight: 3.2 Kg / 7.05lb Specifications and system descriptions accurate at time of printing. These are subject to change. VERIFICATION > The monitor s calibration can be checked using our calibration verification kit. This is an approved method of demonstrating that the unit is still working correctly to Port State Control and Class. www.rivertrace.com 3 Exd Version Smart PFM Smartsafe ORB Smart ODME Smart 50M Smart Turbidity

SMART PFM 107 OIL-IN-WATER APPLICATIONS FPSO/FSO/FSU Produced Water Discharge Drill Rig Slop Tanks Oily Water Separator Discharge Regulatory Compliance PRINCIPLE OF OPERATION The monitor measures particulates in the sample stream on a continuous basis by passing the process fluid through a proprietary photo optical measuring cell developed by Rivertrace Technologies. Using a combination of optical recognition algorithms and light intensity it is possible to differentiate between Oil particles, Gas/Air Bubbles and Solid particulates in the range 0-500 microns. Flow and particulate characteristics can be visualised live via remote access and via optional dedicated software on any Windows PC or via the 7 display. Oil concentration, pressure, temperature and oil alarm status are displayed on an easy to read back lit alpha numeric LCD display. Oil concentrations, alarms and fault log are stored within the system to comply with the reporting requirements of IMO resolution MEPC.107(49) and can be accessed remotely or downloaded onto a pc via LAN or USB for further analysis. When connected to the internet it is possible for remote diagnostics to be performed by the manufacturer or an approved service centre. The Smart-PFM 107 offers a choice of auto cleaning methods to ensure the accuracy is maintained at all times. Dependant of the utilities available you can choose from air driven solenoid or electronic actuator. The cleaning is fully automatic and operates whenever it senses contamination of the optical windows. FEATURES Oil, gas, suspended solid inflow measurements Oil type independent no calibration required Solid particles and gas contamination independent Measure concentration, size and number density of oil, solids and gas Embedded windows with full auto restore via secondary hard Disk Exd version www.rivertrace.com 4

MONITOR Smart Cell Smart PFM SPECIFICATION Oil concentration range Oil concentration accuracy Particle size range Oil alarm 1 & 2 operating point Oil alarm 1 operating delay Oil alarm 2 operating delay Alarm contact rating Alarm relay mode Output signal www.rivertrace.com 5 0-40 ppm for MEPC 107(49) higher ranges available +/- 1 ppm 1 to 500 μm 5 ppm or 15 ppm maximum (adjustable) 1-5 seconds 10 to 600 seconds 5 Amps at 230 VAC De-energised in alarm state 4-20 ma Network communication Ethernet (RJ45) remote access Wi-Fi optional with additional hardware IMO Data transfer Ambient temperature Humidity Sample temperature Sample flowrate Sample pressure Clean water requirements Cleaning system Weight USB 2 Memory stick 0 C to 55 C (32 F to 131 F) 95% maximum non condensing 1 to 70 C (33.8 F to 158 F) 0.5 to 5 l/min (0.26 to 1.3 gpm) 1 to 10 bars (14.5 to 145 psi) None Compressed air at 6 bar (87 psi) 28 kg (62 lbs) Dimensions [mm] Height: 528mm (20.8 ), Width: 600mm (23.6 ), Depth: 280mm (11 ) Supply voltage Supply variation Supply frequency Power consumption Degree of ingress protection Approvals Display : 100-240 VAC or 24 VDC option available +/- 10% of nominal voltage 50-60 Hz 50 VA normal, 100 VA peak IP65 MEPC.107 (49), MED, UL 7" capacitive touchscreen Smart Turbidity Smart 50M Smart ODME Smartsafe ORB

SMARTSAFE ORB BILGE OVERBOARD APPLICATIONS Bilge Water Discharge Security Electronic Oil Record Book Oily Water Separator Discharge Protection Against Magic Pipe The Smartsafe ORB (oil record book) Bilge Overboard Security System was developed in response to our customers worldwide requests and requirements. This system records the oily water discharge process of any Oil Water Separator (IMO - MEPC 60.33 or 107.49) thus avoiding the common mistakes of manual entries and log variations in the oil record book. This is often seen as an easy target for Port State Control and other Marine Enforcing Agencies. In its simplest form the Smartsafe ORB will utilise the ships GPS and records the process of the bilge water discharge. The base unit documents the vessel s time/date/latitude and longitude of the start and stop of the discharge process. The event summary is displayed on the control screen for easy viewing and is used to annotate the oil record book. The system has the ability to record data from up to 3 Oily Water Separators (OWS). This data can be downloaded to a PC, printed or emailed using the built-in email application. The Smartsafe ORB has sufficient memory to store three years of typical discharge records. OPTIONAL COMPONENTS GPS + Interface Unit Printer Flow Meter Secondary Diverter Valve Separator Interface Unit Summary Discharge Log www.rivertrace.com 6

SECURITY SYSTEM Smart Cell SPECIFICATION Supply voltage: Supply variation: Supply frequency: Consumption: Control display: Approval: 100 240V ac ±10% of Nom. Voltage 50/60 Hz 30 VA Max LCD with touch screen interface ABS Type Approval/Product Specifications and system descriptions accurate at time of printing. These are subject to change. This system may be installed in line with any new and existing IMO MEPC 60(33) and 107(49) approved monitors. Smart 50M Smart ODME Smart PFM Smartsafe ORB OCD CM - MEPC 60 (33) Smart Cell MEPC 107 (49) www.rivertrace.com 7 Smart Turbidity

SMARTSAFE ORB BILGE OVERBOARD www.rivertrace.com 8

SECURITY SYSTEM Smart Cell Smart PFM OPTIONAL COMPONENTS GPS & INTERFACE MODULE: FLOW METER & SECURITY CAGE: SECONDARY DIVERTER VALVE & TAMPER PROOF SECURITY CAGE: Where the ships GPS is not able to be used, in cases where there are no spare outputs for example, Rivertrace can provide a standalone NMEA 0183 GPS and Interface module that connects directly into the Smartsafe ORB. Adding a tamper proof electronic Flow Meter to the Smartsafe ORB enables the exact amount of water discharged to be measured which gives the following advantages; Volume of actual Oil discharged overboard can be calculated and recorded utilising the PPM reading from the OCM. To increase the overall security of the system to prevent accidental or malicious discharge or separator bypass, a secondary diverter valve with position feedback can be installed after the standard IMO diverter valve. This secondary valve is controlled solely by the Smartsafe ORB and will immediately be closed should a malfunction or malicious act be detected. Smartsafe ORB Smart ODME SEPARATOR INTERFACE MODULE: PRINTER: In cases where the Smartsafe ORB is installed in the Engine Control Room and the signals from the OCM or Separator are not compatible, a separator interface module is required. This converts any signals from any OCM and any Oily Water Separator into a compatible signal for the Smartsafe ORB. This also enables the Smartsafe ORB to be retrofitted to any vessel irrespective of the type of equipment fitted. By adding a printer to the system the summary discharge log can then be printed at the end of each discharge and attached to the manual Oil Record Book, avoiding potentially costly manual entry errors. www.rivertrace.com 9 Smart 50M Smart Turbidity

SMART ODME TO MEPC 108(49) APPLICATIONS Dirty Ballast Water Discharge Clean Ballast Water Discharge Bio Fuel Approved Easy Installation Smart ODME Pump - Measuring Cell The Oil Discharge Monitoring Equipment (Smart ODME) has been designed to provide means of monitoring, recording and controlling the ballast discharge for crude oil, product and chemical tankers including ICE class vessels. This system is modular in construction and does not require the usual pump/motor bulkhead penetration as used on older systems. The Smart ODME includes all components required to meet MEPC 108(49) and the latest MEPC 240(65) for Bio Fuels, effective 1 January 2016. The Smart ODME incorporates a simulation mode to aid system demonstration to PSC surveyors, is designed for ease of retrofitting, operation, installation and maintenance. Discharge limits are set at 30 litres of Oil per nautical mile or 1 / 30,000 of the previous cargo for dirty ballast. Smart ODME Zener Barrier Module Assembly www.rivertrace.com 10

SPECIFICATION MEASUREMENT Oil types: As Per MEPC 108(49) + MEPC 240(65) requirements Clean water calibration: Automatic Oil measurement range: 0-1000 ppm all types Resolution: 1 ppm Accuracy oil + solids: As Per MEPC 108(49) requirements DATA STORAGE AND RETRIEVAL Data retrieval: via LCD display or download to PC using Hyperterminal or Rivertrace IMOLog downloader programme SYSTEM AND SUPPLY Supply voltage: 115 / 230V ac, 50-60Hz (Switchable) Zener Barrier/Computer Module: 115 / 230V ac, 50-60Hz (Switchable) Motor: 380-440V ac, 50-60Hz, 3 phase, 250W Supply voltage Consumption: < 50 VA Single Phase Approvals: MEPC 108 (49) - DNV GL, GL + USCG, ABS, CCS, NKK, BV, and Russian Register MEPC 240(65) - DNV GL Smartsafe ORB Specifications and system descriptions accurate at time of printing. These are subject to change. Smart 50M Smart PFM Smart ODME Smart Cell www.rivertrace.com 11 Smart Turbidity

SMART 50M OIL IN WATER MONITOR APPLICATIONS Hydrocarbon Leak Detection Lube Oil Cooler Monitoring Boiler Feed Protection Heat Exchanger Leak Detection Produced Water Reuse - RO Feed Water, Steam Generator Feed Water Industrial Wastewater/Groundwater discharge A versatile and sophisticated monitor to suit multiple applications in marine and industrial environments. The Smart 50M uses a nephelometry based detection technique and uses sophisticated algorithms to detect Oil and suspended solids in the sample. The design of the measuring cell allows the monitoring of high temperature and high pressure samples across multiple ranges of Oil Concentration. Auto-Clean and Auto-Zeroing functionality ensures the maintenance is minimal and that the measuring cell is kept free from fouling. The Smart 50M can provide the Oil Concentration value to a DCS or PLC using a 4-20mA output and additional process variables can also be provided using the Modbus digital communications protocol (over RS485). As standard the following data is available: Oil Concentration Sample Pressure Sample Temperature Solids Content Fault Status Alarm and Run states www.rivertrace.com 12

Smart PFM Smart Cell SPECIFICATION Ranges: Low range 0-10ppm Medium range 0-200ppm High range 0-3000ppm Accuracy: Low range +/- 0.15% Medium range +/- 5 ppm High range +/- 200 ppm Alarm 1 Operating Point: Low range 1-10 ppm Medium range 1-200 ppm High range 1-3000 ppm Alarm 2 Operating Point: Low range 1-10 ppm Medium range 1-200 ppm High range 1-3000 ppm Alarm 1 Operating Delay: Alarm 2 Operating Delay: Alarm contact rating: Output signal: Ambient temperature: Humidity: Sample temperature: Sample Flow: Sample Pressure: Clean Water requirements: Weight: 1-15 seconds 1-600 seconds 8 AMP @230VAC 4-20 ma, Modus over RS485, 4-20 ma with HART option 1-60 C / 34 122 F Max 98% non condensing 1-95 C / 34-203 F 0.3-3 Ltrs per min / 0.079-0.79 Gal per min 1.0 Bar Minimum / 14.50 Psi 3.0 Bar Nominal / 43.50 Psi 10.0 Bar Maximum / 145 Psi 0.3-3L per min / 0.079-0.79 Gal per min for zeroing 15kg / 33.07 lb Size: 500 x 360 x 150mm / 19.7 x 14.2 x 5.9 Supply voltage: Power consumption: Degree of Protection: Approvals (pending): 115-230 VAC 15 VA IP56 Tested to EN61010 EN61326 (CE), c UL us. Smart 50M Smart ODME Smartsafe ORB Specifications and system descriptions accurate at time of printing. These are subject to change. www.rivertrace.com 13 Smart Turbidity

SMART TURBIDITY MONITOR APPLICATIONS Exhaust Scrubber Water Monitoring Sewage Treatment Plant Effluent Monitor Brewing Quality Monitor By utilising the Smart Cell Detector Array Technology, developed by Rivertrace technologies, the monitor accurately analyses the quality of the sample stream and outputs the turbidity value in nephelometer turbidity units (NTU) Turbidity is the cloudiness or haziness of a fluid caused by large numbers of individual particles that are generally invisible to the naked eye. A manual cell cleaning device is included as standard to easily enable routine maintenance and prevent Optical cell fouling which is recognised as a leading cause of monitor malfunction or incorrect reading. By simple operation of the manual cleaning device, the measuring cell remains in optimum operating condition. Replacement calibrated measuring cells can be purchased for easy change over and calibration verification kits enable the user to demonstrate the monitor is within factory calibration. The Smart Turbidity Monitor is also available in for Hazardous area Environments classified as Zone 1 & 2. OPTIONS > All options can be ordered from new or retrofitted to existing Rivertrace Smart Cell monitors. AUTOCLEAN > The autoclean option has been designed to ensure that the measuring cell glass tube is kept free from fouling. Cell fouling is recognised as a leading cause of monitor malfunction. Fitting the Autoclean removes the need for the ship s crew to remember to clean the cell manually. VERIFICATION > The monitor s calibration can be checked using our calibration verification kit. This is an approved method of demonstrating that the unit is still working correctly. (Also applicable for Port State Control and Class inspections). www.rivertrace.com 14

Smart PFM Smart Cell SPECIFICATION MEASUREMENT Clean water calibration: +/- 2 NTU of factory set values Turbidity range: 0-100 NTU Accuracy: +/- 1 NTU Response time: < 5 sec Smartsafe ORB ALARMS Alarm 1 set point: Alarm 2 set point: Alarm 1 delay: Alarm 2 delay: INPUT / OUTPUT Analogue output: 1 100 NTU user adjustable 1 100 NTU user adjustable 0 5 seconds user adjustable 0 600 seconds user adjustable Loop powered 4-20mA / 0-20mA 24V Smart ODME DATA STORAGE AND RETRIEVAL Calibration data storage: Stored in cell assembly SYSTEM AND SUPPLY Supply voltage: 115 or 230V AC, 50 60Hz (24V AC & 12V DC available) Supply voltage Consumption: < 50 VA incl. solenoid valve Supply voltage tolerance: +/- 15% Projected life: > 50,000 hrs Protection class: IP 65 Smart 50M Weight: 3.2 Kg / 7.05lb Specifications and system descriptions accurate at time of printing. These are subject to change. 15 Smart Turbidity

HISTORY In the early years the initial Rivertrace product range comprised two 15ppm oily water separator monitors, our OCD1 and OCD2 models. These were later joined by the highly sensitive and successful OCD50 series for boiler condensate monitoring. In 1994 the OCD1 and OCD2 were superseded by the OCD1M and OCD2M models. These in turn were replaced by the OCD CM in response to the introduction of IMO resolution MEPC 60(33) in 2000. 1983 1994 1989 In 1989 the company expanded into the offshore industry, producing a range of custom-made oil-in-water analysers for a variety of applications. As a result we quickly became a leading supplier to North Sea oilfield operators. In the early 1990s we received numerous requests for oil discharge monitoring systems from clients who thought that existing designs had room for improvement. In conjunction with our customers we drew up the specification for a new ODM that could not only meet IMO regulations, but still improve on the performance of equipment available at that time. The Rivertrace Oil Discharge Monitor OCD10M was launched in late 1995. 1995 2005 In 2004 the Smart-Bilge monitor was designed and launched to comply with the new IMO resolution MEPC 107 (49) applicable from the 1st January 2005. As a result of the changes in IMO regulations and the introduction of MEPC 108 (49) also applicable from 1st January 2005 a new Smart ODME design was introduced featuring advanced measuring principles. TODAY Today the company employs approximately 28 people at our 10,000 sq. ft. factory close to Redhill, 20 miles south of central London. Our global network of agents ensures local service and support worldwide. Today we are at the forefront of designing systems that not only meet but go beyond the requirements of tightening environmental legislation. With the introduction of the SmartSafe Bilge Overboard Security System we are continuing to meet new environmental challenges head on. www.rivertrace.com 16

SUPPORT Tech Support Spares Enquiry Returns Rivertrace is committed to providing exceptional customer service which includes aftersales care. Should you require technical support with any of our products, please contact us via the email address below. remotesupport@rivertrace.com If you wish to purchase or make an enquiry about spares, please submit details to the email address below. A member of our dedicated sales team will respond with a list of spares, current costs and lead times. sales@rivertrace.com Our procedure to manage returns, repairs, and replacements ensure turnaround times are as short as possible. To receive a copy of the Rivertrace returns policy please contact the email address below: sales@rivertrace.com ACCREDITATIONS

Rivertrace Limited Unit P, Kingsfield Business Centre Philanthropic Road Redhill Surrey RH1 4DP England Tel: +44 (0)1737 775500 Fax: +44 (0) 1737 775501 email: sales@rivertrace.com email: service@rivertrace.com www.rivertrace.com