Feat u r es. Wh at is an oil separ at or?

Similar documents
LR range (solid door) LR 750 G / GG

SALES SUPPORT DOCUMENT

Carbon Monoxide (CO) detection system

CHAPTER 10 TRAPS AND INTERCEPTORS

intelligent fire alarm ID60series panels

(12) United States Patent (10) Patent No.: US 6,979,403 B2

EM4 APPLICATIONS EXAMPLES

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Make value of the waste energy from your cooling units and heat water for free

UNI 321. User s Guide

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

Pneutrol International limited, 5 Caulside Drive, Antrim, Northern Ireland, BT41 2DU Tel +44 (0)

INSTALLATION INSTRUCTIONS (CANADA)

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Tri-Tech Medical Inc.

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

INSTALLATION INSTRUCTIONS

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VISTA 48DLCT HONEYWELL SECURITY

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Adsorption Air Dryers

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Synco living. Train the Tainer. Functions & Operation Safety & Security. Spring 2008 Page 1/32 Train the Trainer - Spring 2008

Owner s Manual AMERICAN PERC-RITE. WASTEWATER DRIP SYSTEMS 2 ZONE or 4 ZONE SIMPLEX or DUPLEX

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Med Touch Combination Alarm Conversion Kits

MODEL NUMBER NOMENCLATURE

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

ROYALTON SS1 & SS2 RRH OVEN

Brivis Touch Controller. Installer Manual

Installation, Operation, and Maintenance Manual. ASP HDPE Package Sewage Treatment Plants

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Overview of Haarslev s Approach to THP

LIST PRICE SCHEDULE. medical-grade refrigerators. medical-grade freezers. ice and water dispensers. ice machines. slope front bins

AMBIANCE CLX2 Series Wall mounted or recesses into a standard studded wall

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Compressed Air Filtration Oil/water separator for compressed air condensate ultrafilter International UFA-AC

IONIC LAMELLA PLATE CLARIFIER. Small in size - big in performance

SERVICE MANUAL REFRIGERATION

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Intelligent control systems Compressor control systems Overriding control systems Central instrumentation and control

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

ID50series. intelligent fire alarm panels

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

Replacement Parts List For Models COS-101 COS-101S

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Alcon Lighting P Continuum 23 Architectural LED Linear Pendant Mount Direct/Indirect Light Fixture

Replacement Parts List For Models COS-20G

EC 160 CO 2. Incubator

EWF1 WIRELESS SMOKE DETECTOR

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

ROTEX Sanicube: Hot water indirect cylinder.

B/S/H/ Error codes and service programmes PW

3.1 Environment Stormwater Ecology Integration with sport, social and heritage. 3.2 Heritage Levels of scale 3.2.

Addressable Fire Alarm Control System 2100 series

Upright Freezer 048-GM-48307

SYSTEM 5000 USER MANUAL

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

USING THE REFRIGERATOR COMPARTMENT

SCAN200E USER S MANUAL

TS700. Intruder Alarm Control Panel ENT 0 ESC

Inline Sludge Screens Municipal and Industrial Applications

Quick Guide. Carefully read the user handbook provided before using the appliance. Refrigerator Compartment 1. Control panel

SFC-200 SERIES LED FIRE ALARM PANEL

THERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration

EMD - Rotary Drum Screens

1. SYSTEM DESIGN PER NFPA 72 AND LIFE SAFETY SYSTEM SHALL HAVE 24 HR BACKUP BATTERIES

Pretreatment. Complete Line of John Meunier Products and Solutions WATER TECHNOLOGIES

CHAPTER 10 TRAPS AND INTERCEPTORS

ROTISSERIE OVEN PROGRAM GUIDE

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

WATCHDOG Alarm Instruments. Safety for Industry and Building Technology

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

Effective october 14, 2014

Jacopa Tipping Bucket

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

Fire control panels FC726 FC726-XA

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Solve Complex Comfort Challenges.

Fire Alarm Network Reference

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

ENGINEERING. Product Overview #AR-OV-11a

OPERATION & MAINTENANACE MANUAL

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2

Components Brochure DX CONNEXION

Food and Beverage. Application Notes. June, 2018

Transcription:

OIL EPARATOR

Wh at is an oil separ at or? An oil separator is a compact device that removes oil from water. The dimensions of the oil separators are calculated according to oily water flow. The separated oil from water are collected inside the separator in a compartment as the water is discharged into the effluent lines. Feat u r es Made from tainless teel, HDPE or Epoxy Coated teel st37 Equipped with high quality and unique components Easy installation, easy operation and low maintenance Excess oil storage and sludge / silt storage are standard features on all our oil separators, standard and automatic models. Adjustable weir is installed to control the oil flow level to the internal access oil storage, a standard feature on both manual and automatic models Odor protection is a standard feature in all our models. The separators are equipped with a vent which may be connected to a stack and odor removal housing. The heater keeps the excess oil at a constant temperature to prevent solidification caused by cold weather. The heater works automatically when the excess oil?s temperature drops below 15 C. Emptying valves are necessary when the system needs to be flushed. Excess oil and screen emptying valves are used to remove the excess oil and sludge when the separator?s storage is full. ludge screen removal pump removes the accumulated sludge through the filtration unit by dewatering. The sludge / silt pump works automatically. Excess oil pump removes the excess oil from the internal storage Excess oil level alarm system notifies the operator of the oil level inside the storage. Full protection control electrical board is equipped with various features and options like current protection, heater temperature controls and many more.

Wh er e do you u se Oil epar at or s? Food production factories Restaurants and cafeterias Hotels and holiday sites laughter houses Meat / Fish processing factories Car maintenance shops and Garages Facilities that use / deal with oil Waste water treatment plants Power plants t an dar ds; Oil & Grease eparators complies with EN825 1 and EN8252 standards

Types & M odels Oil & Grease eparators are designed for maximum efficiency and easy operation & maintenance. Various models are available for specific requirements such as: Undercounter Type Automatic / Manual Aboveground / Underground Oil eparators with builtin Pumping tations Aboveground Underground

Un iqu e Feat u r es Our products are equipped with unique equipment. Excess Oil torage and ludge/ ilt torage are standard in all our oil separators. tandard in Automatic and Manual Models. Adjustable Weir is used during installation to arrange the oil flow level to the internal excess oil storage. tandard in Automatic and Manual Models. Odor Protection is taken into consideration in all our design. Our separators are equipped with a Vent which may be connected to stack and an Odor Remover Housing. Heater keeps the excess oil at a constant temperatures to prevent solidification due to the climatic conditions. Works automatically when the excess oil temperature drops below 15 C. OW Empty Valves are necessary in case the system needs to be emptied. Excess Oil & ilt Empty Valves are to be used to remove the excess oil and silt when the separator storage is full. ludge ilt Removal Pump and Filtration Unit removes the accumulated sludge and the filtration unit dewaters the sludge. The sludge/slit pump works automatically. Excess Oil Pump removes the excess oil from the internal storage. Excess Oil Level Alarm ystem notifies the operator for the oil level inside the storage. Full Protection Control Board is equipped with various features and optionals from electrical current protection, heater temperature controls and many more.

EQUIPM ENT / INTRUM ENTATION Equ ipm en t / In st r u m en t Au t om at ic epar at or s M an u al epar at or s Removable ilt creen Adjustable Weir s Excess Oil torage Excess ludge torage Indirect Oil Heater OW Empty Valves Excess Oil & ilt Empty Valves ludge/ilt Removal Pump ludge/ilt Filtration Unit Excess Oil Removal Pump Excess Oil Level Alarm ystem O Full Protection Control Board O / tandard O / Optional / NA

Con t r ol Un it Feat u r es f or Au t om at ic M odels On ly applicable f or m odels: ZU (Un der Gr ou n d) / ZA (Above Gr ou n d Con t r ol Boar d Feat u r es 4x20 mah led screen with LCD panel / color display touchscreen Timer system with 90 days reserve Current measurement and monitoring every pump and equipment showing on/of position and total operation time Active and passive options for every pump and equipment Maximum protection with Operational Voltage et feature Main voltage measurement with emergency shut down for over or undervoltage For each instrument there is a led indicator on the screen Digital temperature control for separated oil heater. 'full', 'empty' signals and level detection for the waste oil Operational Logging and monitoring on LCD screen Contact relays for malfunctions or alert such as; 'full oil', 'fault', 'no network', 'over voltage' for main control systems (i.e. CADA) Log listing for; "Commissioning Date, erial No., Malfunction History, Last Maintenance Date" et feature for all controls and "Back to Factory ettings" feature Alarm with ound (Buzzer), Light (Led) and in Text (LCD creen) Optional M module for text messaging in case of failure or alarm

+90 212 876 2282 +90 212 876 3832 w w w.k azan cioglu.com bilgi@k azan cioglu.com Beylik dü zü O..B. M er m er ciler an ayi it esi 3. Cadde No:21 Beylik dü zü / ITANBUL TURKEY