AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

Similar documents
ULTIMA ID PRO OPERATION MANUAL. Analyzer Part Number: 69HVAC -PRO2

"World Class Quality" ULT/MA ID- HVAC REFRIGERANT IDENTIFIER OPERATION MANUAL

YELLOW JACKET. Refrigerant Identifier OPERATION MANUAL. Part Numbers: Manufactured by:

ACTIVATE BEFORE FIRST TEST

Operation and Maintenance

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

The Dedicated Refrigerant Identifier

The Portable Refrigerant Diagnostic Tool

DiscovR R134a Refrigerant Identifier

Which Refrigerant Analyzer do I have? Ultima ID Model RI-2004HV Series

R EFRIGERANT A NALYZER S & ACCESSORIES

Operating Manual. Model CoolTech ID Refrigerant Identifier

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

The Inspector Automotive Refrigerant Identifier Part Number:

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Refrigerant Recovery Machine. Model No Operating Manual

and Refrigerant Identifier

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Section 2. Air Conditioning & Cooling System Service Equipment. Section 2: Suppliers: CALL:

OPERATION & MAINTENANCE MANUAL TC670

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

Caresaver Universal Refrigerant Recovery Unit

Automatic Water System Pump SERIES

Original Instructions Instucciones originales Consignes originales. Model: AC R-1234yf A/C Recover, Recycle, Recharge Machine

IMR IX176 Portable Gas Detector User Manual

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Model AC Original Instructions. Recover, Recycle, Recharge Machine for R1234yf A/C Systems

R100 Oil-Less Refrigerant Recovery Unit

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Safe Operation Manual. Honeywell IQ Force Gas Detector

OPERATION & MAINTENANCE MANUAL RHS680

User manual Flushing device VAS 6337/1a

CA5000 Liquid CO 2 Freezer Backup System

Installation Requirements for Models:

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

OPERATION & MAINTENANCE MANUAL AC860

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

TRS21 IGNITION PROOF SERIES

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

BAC 4000a BAC 5000yf

OPERATION & MAINTENANCE MANUAL AC880

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Sleeper Heater and Air Conditioner, Blend Air System 83.05

OPERATION & MAINTENANCE MANUAL TX600

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

TRS21 IGNITION PROOF SERIES

Operating Manual for. Model Recovery, Recycling, Recharging Unit

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

OWNER S MANUAL (English)

APC BC300 Series 40kW 208/450/480V User Guide

Read all instructions & warnings before using this product. Keep this manual for future reference. Warnings. Parts & Accessories

OWNER S MANUAL (English)

Reference Manual. MultiVision Gas Detector

Operating Instructions

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Operation Manual... 1 Manuel d utilisation Manual de Operación.. 60

AC1234 PRODUCT RANGE.

REFRIGERANT SYSTEM SERVICE WARNINGS

Model gffoz Process Ozone Sensor (In-Line)

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

Operate the Mutli-Gas Monitor PID

MGC Dock User s Manual

OWNER S MANUAL (English)

R134a RECOVERY/RECYCLE/RECHARGE Operating Instructions

AS950 REFRIGERATED SAMPLERS

RLD-H10P Refrigerant Leak Detector

Operating Manual. Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a

Carbon Dioxide Sample-Draw Detector Operator s Manual

Operation and Maintenance Manual

Hybrid Conversion Kit Procedure Guide

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Setup and Operation Manual

Recalibrate the way you look at gas detection

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

USER'S INFORMATION MANUAL

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Operating instructions

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

5000 Series Bottled Water System by.

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

LS-JRE OPERATION & INSTRUCTION MANUAL

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

User`s Manual. Using the device The basic diagram of product

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

3-1/2 Gallon Parts Washer

RECOVERY/RECYCLE/RECHARGE

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 PRECAUTION... 2 PREPARATION... 4 FUNCTION DIAGNOSIS...

D-TEK Select. Refrigerant Leak Detector

Transcription:

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL Analyzer Part Number: 68941

Table of Contents FOR YOUR SAFETY:... 3 IDENTIFIER WARNINGS/GENERAL CAUTIONS... 3 WELCOME... 5 1 INTRODUCTION AND OVERVIEW... 5 1.1 GENERAL... 5 1.2 FEATURES... 6 1.3 YELLOW JACKET 68941 COMPONENTS... 7 1.3.1 Ultima ID Base Unit... 7 1.3.2 R134a Sample Hose and 1/4" Flare Sample Hose.. 7 1.3.3 R134a Tank Adapter Fitting... 8 1.3.4 AC Power Adapter... 8 1.3.5 Control Panel... 9 1.3.6 Back Panel Connections... 9 1.3.7 Hard Shell Storage/Carrying Case... 10 2 YELLOW JACKET 68941 OPERATION... 11 2.1 FIRST USE... 11 2.1.1 Battery Charging... 11 2.2 TURNING ON THE UNIT... 11 2.3 CALIBRATION... 11 2.4 TESTING THE REFRIGERANT... 12 2.5 VIEWING THE TEST RESULTS... 12 2.6 PRINTING THE TEST RESULTS... 13 3 MAINTENANCE & TROUBLESHOOTING... 14 3.1 INSTALLING PRINTER PAPER... 14 3.2 CHANGING THE SAMPLE FILTER... 14 3.3 REPLACING THE SAMPLE HOSES... 15 3.4 LOW BATTERY WARNING... 15 3.5 ERROR MESSAGES.15 4 APPENDICES... 15 4.1 SPARE PARTS LIST... 15 4.2 APPENDIX B - SPECIFICATIONS... 16 2

For Your Safety: PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE ATTEMPTING INSTALLATION OR OPERATION! Attempting to operate the YELLOW JACKET 68941 without fully understanding its features and functions may result in unsafe conditions Always use protective eye wear and observe proper safety procedures when working with pressurized gases. Identifier Warnings Counterfeit Refrigerant Warning: Counterfeit refrigerant blends containing highly dangerous substances have been found in the marketplace. These substances include, but are not limited to, R40 (Methyl Chloride or Chloromethane). This and other substances require extreme care and special handling. It is the responsibility of the user to understand the life threatening dangers of these substances and take appropriate cautionary measures when connecting this device to the service port of the system. Failure to take appropriate precautions may result in fire, explosion, injury or death. Sample Filter Warning: Replace the sample filter of the instrument AS SOON AS RED SPOTS OR DISCOLORATION BEGIN TO APPEAR ON THE OUTSIDE DIAMETER OF THE WHITE ELEMENT. Failure to properly maintain and replace the sample filter will result in severe damage. Sample Input Warning: The instrument requires connection of the supplied sample hose to the LOW SIDE OR VAPOR port of refrigerant storage cylinders or air conditioning systems. DO NOT attempt to introduce liquid or samples heavily laden with oil into the instrument. DO NOT connect the sample hose to the HIGH SIDE or LIQUID port! Liquid or oil laden samples will cause severe damage to the instrument that will not be covered under warranty repairs. Connection to power sources greater than 13V DC could cause out of warranty damage. Only the supplied power supply or factory supplied replacement may be used. No operator access is permitted inside the enclosure. If the equipment is used in a manner not specified by the manufacturer, the protection by the equipment may be impaired. 3

General Cautions Operate this unit with vehicles or cylinders marked to contain R-1234yf refrigerant. Cross-contamination with other refrigerant types causes severe damage to the A/C system, to service tools, and equipment. Do NOT attempt to adapt the unit for another refrigerant. Do NOT mix refrigerant types through a system or in the same container. Some vehicles may contain illegal substitute refrigerants that may contain hydrocarbons. R-1234yf is considered a flammable substance. Failure to follow the manual can result in serious injury or death. Less than 2 grams of R-1234yf and unknown sample types are required to be vented with each sample. This identifier is designed with sealed heat sources and without sparking components. Ensure adequate ventilation in the recycling machine design to prevent the accumulation of refrigerants. DO NOT breathe refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose, and throat. If accidental system discharge occurs, immediately ventilate the work area. There must be adequate ventilation in the vehicle servicing area. The air detection sensor is a chemical fuel cell sensor that will eventually expire. The user must return the unit to replace the air detection sensor whenever the instrument indicates as such. Failure to replace the air detection sensor will result in non- functionality of the instrument. Wear eye and skin protection when working with refrigerants. Escaping refrigerant vapors can freeze upon contact. Do NOT direct refrigerant escaping from the sample hose toward exposed skin or toward the face. 4

WELCOME Thank you for purchasing the YELLOW JACKET 68941 Refrigerant Identifier. The YELLOW JACKET 68941 is the most advanced refrigerant identifier ever designed for determining the purity of specific gaseous refrigerants. It has many features to offer the user, which will be described in this manual. We recommend that all personnel who use this instrument read this manual to become more familiar with its proper operation. For further information regarding the application, operation or spare parts, please contact the Ritchie Engineering Co., Inc. Customer Service Department. If you have questions or comments, we would like to hear from you. Ritchie Engineering Co., Inc. 10950 Hampshire Avenue South Bloomington, MN 55438 Tel: (952) 767-7208 EMAIL: custserv@yellowjacket.com Visit us at www.yellowjacket.com 1 INTRODUCTION AND OVERVIEW 1.1 General Contamination of refrigerants either in storage cylinders or air conditioning systems can lead to component corrosion, elevated head pressures and system failures when utilized by unsuspecting technicians. The ability of the technician to determine refrigerant type and purity is severely hampered by the presence of air when attempting to utilize temperature-pressure relations. The development and introduction of various counterfeit and substitute refrigerants further complicate the ability of a technician to identify refrigerant purity based upon temperaturepressure relationships. The counterfeit and substitute refrigerant blends can also introduce a flammability hazard to the technician and the ultimate end user of the air conditioning system. 5

The YELLOW JACKET 68941 Refrigerant Identifier will provide a fast, easy and accurate means to determine refrigerant purity in refrigerant storage cylinders or directly in air conditioning systems. The instrument utilizes non-dispersive infrared (NDIR) technology to determine the weight concentrations of refrigerant types R134a, R12, R22, Hydrocarbons, Unknown and Air. Refrigerant purity is automatically determined for R134a refrigerant by the instrument to eliminate human error. The instrument is supplied complete with a ¼ flare and R134a sample hose, a R134a adapter fitting to permit sampling of ACME ported cylinders, a 12 VDC power supply and all required plumbing housed within a rugged, portable, storage case. Sample gas is admitted into the instrument through the supplied sample hose and presented to the sensing device. The instrument provides the user with direct, % by weight, concentrations of R134a, R12, R22, Hydrocarbons, Unknown and Air. Note that the instrument does not consider air to be a contaminant since it can be removed by most refrigerant recycling equipment. Since air is not considered to be a contaminant, it is possible to read 100% R134a plus 5% air. The instrument interfaces with the user with an LCD graphic display, status indicator lamps, and push button communication switches. Alarm indications are provided to alert the operator of instrument fault conditions or contaminated refrigerant presence. Direct, % by weight, concentrations of the sample refrigerant are provided on the display as well as user directions and prompts. An on-board printer is included to print on-the-spot test documentation. 1.2 Features The YELLOW JACKET 68941 Refrigerant Identifier is the most advanced instrument ever manufactured for determining the purity of gaseous refrigerants for the automotive market. Advanced ergonomic design Large graphic display with on-screen instructions Ultra fast 90 second test time Unknown channel to represent many refrigerants that are not R134a, R12, R22 or Hydrocarbons Electrochemical Fuel Cell Air Sensor Built in printer for instant test documentation Internal, rechargeable battery for cordless operation in any location USB Port for Field Software Updates Hard shell carry/storage case 6

1.3 YELLOW JACKET 68941 Components 1.3.1 YELLOW JACKET 68941 Base Unit The YELLOW JACKET 68941 base unit houses the Graphic Display, Infrared Bench, Electrical Connections, and Printer Module. These components require no maintenance, therefore there are no serviceable components internal to the instrument, and disassembly will void the warranty. Printer Door Control Panel Sample Filter Air Intake Port 1.3.2 R134a Sample Hose The 2 meter R134a Sample Hose is constructed of polyurethane ether with a plastic fitting on the analyzer end and a brass flow restrictor on the service end. The brass flow restrictor is mated to the R134a Low Side Coupler. The sample hose is considered a consumable maintenance part. (Replacement P/N 6-02-6001-32-0) Service End R134a Low Side Coupler Identifier End 7

1/4 Flare Sample Hose The 2 meter 1/4 Flare Sample Hose is constructed of polyurethane ether with a plastic fitting on the analyzer end and a brass flow restrictor on the service end. The brass flow restrictor is mated to a ¼ Flare Low Side Connector. The flow restrictor, clear hose and plastic fitting are considered a consumable maintenance part. Analyzer End Service End (1/4 SAE Flare Nut) 1.3.3 R134a Tank Adapter Fitting The R134a Tank Adapter Fitting will provide the user with an adapter to allow connection of the R134a sample hose to a R134a cylinder ACME port. ½ Acme Thread (Threads onto Cylinder Stub) R134a Low Side Stub (Fits into R134a Low Side Coupler) 1.3.4 AC Power Adapter O-Ring Seal (Internal) The YELLOW JACKET 68941 is powered from an internal LiFe battery pack. A 12 VDC Power Adapter is supplied to charge the battery and power the unit simultaneously for uninterrupted use. 8

1.3.5 Control Panel The Control Panel serves as the main user interface. The Control Panel features three soft key buttons that change their function as the instrument changes modes. The current function for each button is displayed by the soft key label at the bottom of the graphic display. Red and Green LED s at the top of the Control Panel are used for visual Pass/Fail indications. Green LED Red LED Soft Key Buttons Graphic Display Power On/Off 1.3.6 Back Panel Connections The connections located on the back panel are illustrated below. CAUTION: The sample outlet port should never be obstructed. Keep the sample outlet port free and clear at all times. Do Not Connect anything to the USB Port except factory software updates. USB Sample Inlet Sample Outlet 12VDC Power Input 9

1.3.7 Hard Shell Storage/Carrying Case The hard shell storage/carrying case is custom fit to the YELLOW JACKET 68941. It provides rugged protection for the instrument as well as convenient storage for all components. The enclosure is general purpose and is not watertight. 10

2 YELLOW JACKET 68941 OPERATION 2.1 First Use 2.1.1 Battery Charging The YELLOW JACKET 68941 has an internal, LiFe, rechargeable battery. Charge the battery for a minimum of two hours with the supplied power supply prior to first use. 2.2 Turning On the Unit Press the left power button and the splash screen shown in Figure 1 will appear. After selecting OK, the warm up screen shown in Figure 2 will appear for 30 seconds followed by the calibration screen shown in Figure 3. Connect the appropriate sample hose to the identifier now. LOW BAT VER XXX-XXX WARMING UP READY CONNECT HOSE TO DEVICE PAPER OK OFF CALIBRATE Figure 1 Figure 2 Figure 3 2.3 Calibration Each time the YELLOW JACKET 68941 begins a new test cycle it must first self-calibrate. The calibration takes 30 seconds and brings fresh air into the unit via an internal pump. This fresh air purges any excess refrigerant from the unit and ensures accurate test results. Calibration requires that the hose be connected to the device and disconnected from the AC system or refrigerant cylinder. Pressing the Calibrate button shown in Figure 3 will begin the calibration process and display the screen shown in Figure 4. 11

CALIBRATING READY CONNECT HOSE TO SOURCE TESTING OFF OK Figure 4 Figure 5 Figure 6 2.4 Testing the Refrigerant After the self-calibration is complete, the instrument is ready for testing the refrigerant and will display the screen shown in Figure 5. Connect the hose to the Low Side Vapor Port of the AC system or cylinder and open the valve. Press the OK button to begin the test and the screen shown in Figure 6 will be displayed. 2.5 Viewing the Test Results Upon completion of the test, close the source valve or disconnect the coupler. The YELLOW JACKET 68941 will display a screen similar to that shown in Figure 7 or Figure 8. R134A: 92.2 R12: 0.0 R22: 4.1 HC: 0.0 UNK: 3.7 AIR: 0.0 OFF PRINT OK R134A: 100.0 R12: 0.0 R22: 0.0 HC: 0.0 UNK: 0.0 AIR: 1.5 OFF PRINT OK Figure 7 Figure 8 If the refrigerant tested is 99.9% - 100.0% pure R134A the Green LED will illuminate. Should the refrigerant be less than 99.9% pure, the Red LED will illuminate. In either case, pressing the left button will turn the unit OFF, the center button will PRINT the test results and the right OK button will return to the calibration screen shown in Figure 3. Any indication on the UNK (Unknown) may indicate the presence of R40 or other highly dangerous substances. Extreme care should be used before taking any further action related to the AC System. 12

2.6 Printing the Test Results The test results can be printed by selecting the PRINT button. After the print is complete, carefully tear off the printout and the unit will return to the previous screen. Additional printouts may be made following the same procedure. Figure 9 and Figure 10 show sample printouts for various test results. 68940 Refrigerant Analyzer - TESTED R134A - R134A = 92.2% R12 = 0.0% R22 = 4.1% HC = 0.0% UNK = 3.7% AIR = 0.0% (Date) (Technician) XXXX-XXXX-XXXX XXXX-XXXX-XXXX Figure 9 68940 Figure 10 Refrigerant Analyzer - TESTED R134A - R134A = 100.0% R12 = 0.0% R22 = 0.0% HC = 0.0% UNK = 0.0% AIR = 1.5% (Date) (Technician) XXXX-XXXX-XXXX XXXX-XXXX-XXXX 13

3 MAINTENANCE & TROUBLESHOOTING 3.1 Installing Printer Paper The YELLOW JACKET 68941 is equipped with an on-board printer and uses an inexpensive thermal paper for printing. The paper roll should be changed when a red stripe appears on the left side of the printout. Open the printer door and remove the old roll by tearing the paper as it enters the printer then pressing the PAPER button shown in Figure 11 until the old roll exits the printer completely. Insert the new paper roll from the underside as shown below: LOW BAT VER XXX-XXX PAPER OK To feed the new paper roll, press the PAPER button on the Welcome screen as shown in Figure 11. This will feed the paper into the printer mechanism. Slide the paper through the slot in the printer door and close the door. 3.2 Changing the Sample Filter Figure 11 When inspecting the sample filter, look completely around the entire outside diameter of the white filter element located inside of the clear plastic housing. Look for red spots or the beginnings of discoloration on the white outside diameter of the element. Do not look into the round ends of the white element for red spots or discoloration. The round ends of the filter may always appear red. If red spots or discolorations are discovered, the sample filter requires replacement to prevent the influx of particulate and oil mists into the instrument. Obtain a replacement filter. Remove the existing filter from the retaining clip of the instrument by pulling straight up and out. CAREFULLY remove the flexible, black rubber tubing connections from both ends of the existing filter. DO NOT allow the tubes to slip back into the internal portion of the case. Discard the existing filter in an environmentally friendly manner. 14

Install the tube ends onto the barbs of the replacement filter, taking note to align the flow arrow of the filter with the flow arrow of the instrument top panel. CAREFULLY slide the tubing back into the internal portion of the instrument and seat the new filter into the retaining clip. Inspect the sample hoses for signs of oil entrapment. Replacement of the sample filter usually requires cleaning or replacement of the sample hoses. 3.3 Replacing the Sample Hoses If the sample hose assemblies become discoloured damaged, or the instrument displays a repeated High Air Content error, the sample hose should be replaced. 3.4 Low Battery Warning A Low Bat indication will appear on the upper right of the screen if the internal battery voltage falls below an acceptable level. The instrument should then be connected to AC power using the included power supply to recharge the battery. 3.5 Error Messages In the unlikely event that an Error message is displayed on the screen, power off the unit, take it to a location outside of the shop environment where fresh air is available and turn the unit back on. If the Error message reappears, contact our service department for assistance. Ritchie Engineering Co., Inc. 10950 Hampshire Avenue South Bloomington, MN 55438 Ph: 952-767-7208 custserv@yellowjacket.com 4 APPENDICES 4.1 Spare Parts List 68948 PART NUMBER DESCRIPTION Optional internal rechargeable battery kit with battery and 110V charger 68949 Optional 110/220V power adapter 68950 Thermal printer paper 1 roll 68977 In line identifier replacement filter 68978 R-12 replacement hose 68979 R-134a replacement hose 68994 Replacement flow restrictor hose (3 pak) 15

4.2 Appendix B - Specifications SAMPLE PARAMETERS: DETECTED COMPOUNDS: SENSOR TECHNOLOGY: REFRIGERANT SAMPLE: ACCURACY: POWER: OPERATIONAL TEMPERATURE: UNKNOWN REFRIGERANTS Vapor only, oil-free, 300 psig (2 MPa) Maximum R134a, R12, R22, Hydrocarbons, Unknown & Air Non-Dispersive Infrared (NDIR) 0.15 ounces (4 grams) per sample Better than +/- 2% for detected compounds when the R134A value exceeds 90%. R40 Detection begins between 2 3%. 12 VDC, 2 Amps Maximum 50-122 o F (10-50 o C) The YELLOW JACKET 68941 is capable of detecting the presence of refrigerants such as R40, R32, R125, etc. and will display them in the Unknown Channel. Detection of these refrigerants begins at concentrations between 2-3%. 16