Solar Technology. CPC and Sunnyline. collectors. makes you independent. Pelletskessel.

Similar documents
makes you independent Solar Technology

Fresh water modules premium-line

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

Solar heating systems

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

Solar collectors. Speaker

Gas condensing boiler (wall mounted) TopGas

A strong team A ++ A +++ ROTEX gas hybrid heat pump

Frequently Asked Questions Solar Collector G24

KEMPER ThermoSystem. For further information on KTS use the QR code!

Solar technology VITOSOL 100-F VITOSOL 200-F VITOSOL 200-T

Soak in the Sunshine. Solar Hot Water

using Solar energy efficient efficiency rate

Gas condensing boiler UltraGas

Installation instructions

A strong team A ++ A +++ ROTEX gas hybrid heat pump

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

TopGas Wall Hung Condensing Gas Boiler

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

ROTEX gas hybrid heat pump. A strong team.

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Evacuated Tube - Solar Collector

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

ADVANCE ELECTRIC THERMAL STORE

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Heating with log wood

SOLAR HEATING SYSTEMS

English. Heating with logs & wood pellets 20-40

Press. Solar heating from Viessmann: innovative collectors for DHW generation and auxiliary heating

HT V2 HT Split

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

SOLAR TUBE COLLECTORS

The owner. Leszek Skiba. The company holds the required certificates and implemented the Quality Management System with ISO 9001:2000 Standard.

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

LATENTO Solar system. All-year solar systems Plastic storage tanks Vacuum tube collectors Solar - regulation Accessories

Heating with wood chips

UltraOil Condensing Oil Boiler

Solar water heating system

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

Type BK 20 BK 30 BK 50

The types BK 20 to BK 100 convincing power

Installation and operating instructions. DK energy storage and DK energy buffer

HERZ ECO-Line Heating with logs or wood pellets

Heating with pellets kw

Solar. domestic hot water systems. Using the sun s energy to provide hot water

Slide 1 Jul 20, 2006 Viessmann UK

TERMO Combi Cylinder TECHNICAL INFORMATION

GASOKOL TANK SYSTEM COMPACT, HYGIENIC, FUNCTIONAL, HIGH-PERFORMANCE

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Log fired heating system

ADVANCE ECB ELECTRIC COMBINATION BOILER

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

NOW FUTURE BUILDINGS CATALOGUE EUROPE SPRING / SUMMER 2018 HEALTHIER INDOOR CLIMATE + ENERGY SAVINGS WITH ULTRA-EFFICIENT SOLAR AIR TECHNOLOGY

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Forward-looking and energy effi cient Biomass heating

Efficient heating that won t cost the earth

maximise the sun s energy with warmflow solar Warmflow Solar

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

S SOLAR RANGE

GIALIX. An adjustable power to match your needs for more economies! Wall-mounted electric boiler 2 to 196 kw. F RENCH Manufacturer.

Danfoss the world s biggest producer of radiator thermostats

For latest prices and delivery to your door visit MyTub Ltd

UNLIMITED SOLAR ENERGY. FREE DELIVERY. 100% ENERGY, FREE FOREVER FOR HOT WATER AND HEATING

Aquamatic Instantaneous DHW production unit with integrated storage tank

Hot water on demand with incorporated energy saving function

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Simple solutions are usually the best...

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

QUANTUM. Series and features of the energy-efficient chiller series

VIESMANN. VITOSOL Flat-plate collectors and vacuum tube collectors Flat and pitched roof installation, and wall mounting.

Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

The new standard. The best solar absorber tubes. The highest performance collector. Efficient modular assembly system

INDUSTRIAL / DOMESTIC WATER HEATERS

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Heating with wood pellets kw

So far, we have covered the basic concepts of heat transfer and properties.

Compact and efficient.

CI/SfB (53) First Issue November Flat Panel & Heat Pipe Solar Thermal Systems

Components for solar heating systems

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

G124X - G234X - G334X Atmospheric Gas Boilers

Transcription:

Solar Technology CPC and Sunnyline makes you independent collectors www.fotolia.com Pelletskessel

We want you to be more than satisfied we want you to be excited! www.fotolia.com 2

makes you independent Sun Heat free of charge! l l l makes you independent is inexhaustible is environmentally friendly 3

The sun never sends us a bill In just 3 hours, the sun supplies enough energy to cover the annual energy needs of the entire population of the earth. The potential of solar energy is thus greater than the sum of all other renewable energy sources together. Both diffuse and direct sunlight (solar radiation) can be used for energy generation. Solar constant 1367 W/m 2 The average annual global radiation in Central Europe totals approx. 950 to 1.500 kwh/m² Absorption in the atmosphere Reflection by clouds Diffuse sunlight Direct sunlight + Direct sunlight Available solar energy Scatter in the denser atmosphere Diffuse sunlight Ground reflection Solar thermal technology With solar thermal technology, solar sunlight is converted into heat. This principle is used for DHW preparation and for heating support. Short-wave sun rays strike the highly selective coating of the absorber in the collector; 95% of these are absorbed and converted into heat. This generates long wave radiation. Thanks to the crystalline surface of the coating, no heat is radiated. Solar radiation on the collector 1 Sun rays strike the collector 8 Usable heat energy 2 1 Optical losses 2 Radiation from the glass surface 3 Absorption in the glass 4 Reflection from the absorber surface 8 5 7 4 3 Thermal losses 5 Heat radiation of the absorber 6 Thermal conductivity of the absorber 7 Convection between glass surface and absorber 6 4

makes you independent Solar irradiation during the course of the day The theoretically optimum orientation would be exactly to the south in order to be able to use the solar irradiation throughout the day. As the conditions in the early morning hours are less favourable to the use of solar energy (morning mists, cooler air temperatures), a deviation of approx. 10 to the south-west is recommended. As a result, the poorer conditions in the morning are deliberately not used, but the late afternoon sun can be utilised longer and under better conditions. 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 90 90 WEST EAST 80 70 Azimuth (degrees) 60 70% 80% 90% 95% 100% 50 40 30 20 10 Roof inclination (degrees) 10 0 SOUTH 20 30 40 60 70 80 Azimuth 50 (degrees) A heart of copper The heart of any collector is the absorber which converts the incident sun rays into heat. SOLARFOCUS uses only copper absorbers which are coated with a highly selective layer. Thanks to the crystalline surface of the coating, around 95% of the sun rays are absorbed. Cu Airtight and watertight design of SOLARFOCUS CPC collectors In contrast with conventional flat plate collectors, the CPC collector has an airtight and watertight construction. When heated, the air inside expands and the pressure is relieved via a special pressure relief valve. When the collector cools down again, a partial vacuum is created and the solar safety glass is supported over a large area by the reflectors. The airtight and watertight design without ventilation holes and rivets prevents any soiling of the absorbers, provides permanent protection for the inside of the collector and guarantees constant energy yields for years to come. Standard flat plate collector: Dirt deposits reduce the collector yield The sun's rays cannot penetrate. Greater energy losses SOLARFOCUS CPC collector: Sealed construction guarantees consistently high energy yields for decades The sun's rays are absorbed at 95%. Only 5% of energy is lost. (thermal emission) 5

Sophisticated technology in detail The collector is exposed to environmental influences such as wind, rain, dirt, UV radiation, snow loads and extreme variations in temperature over a period of decades. It is therefore all the more important that only high-quality materials are used that can withstand these adverse conditions. Materials such as wood, plastic and rubber do not offer the necessary resistance in the long term. Collector tray (1) l The 1.5 mm tight welded aluminium tray without ventilation holes forms the foundation. l The airtight and watertight design without ventilation holes and rivets protects the inside of your collector for decades. Absorber (2) l The highly selective coated copper absorber impresses with a solar absorption rate of approx. 95% and a thermal emission rate of approx. 5%. l The floating absorber coated on both sides guarantees maximum energy yields. PREMIUM up to condensation according l TECHNOLOGY l BENEFIT Reflector (3) l The cylindrical, high-gloss rolled, galvanically anodized pure aluminium reflector concentrates the penetrating solar radiation onto the vertically installed absorber ship. l The cylindrical, mirror-finish rolled, galvanically anodised pure aluminium reflector bundles the incidental sun rays onto the vertically installed absorber strip. The reflectors in the tray are protected against environmental influences, thereby guaranteeing a long service life. No wear of the coating. Optimum light bundling by the cylindrical form of the CPC reflector. As a result, the diffuse fraction of the light is also absorbed (Kdiff = 0.87). Solar safety glass (4) l 4 mm low iron content prism structured solar safety glass l Very high light permeability for high yields, impact and 1 hail-resistant Special seal (5) l Permanently elastic UV-protected special seal 8 years Guarantee Guarantee according to guarantee pass l Connects the tray, the glass and the glass holding strip. Diffusion-proof. Prevents the ingress of moisture and dirt. Glass holding strip (6) l Anodised aluminium special profile. l A UV and weathering-resistant aluminium profile instead of a rubber seal ensures the protection of the glass edges. Guarantees the lasting connection of glass and tray. 6 NO VENTILATION BORES NO PLASTIC

makes you independent Flush-sealing connections (7) l 1/2 external thread with flat seal l The surface seals on the inside and outside of the tray are fastened plane-parallel with brass nuts and hermetically seal the tray against environmental influences. No rubber or plastic seals susceptible to weathering. Simple hydraulic connection of the collectors. SCHEMATISCHE DARSTELLUNG 9 7 4 3 2 5 Schematic view: CPC-Kollektor 6 Negative pressure relief valve (8) l When the air inside the collector is warmed for the first time, the air expands and a positive pressure is created. The valve opens and the air can escape. When the air cools again, the valve closes and a negative pressure is created inside the collector. The reflectors support the glass pane on the tray. l No corrosion inside the collector caused by aggressive ambient air. No exchange between inside and outside air, and hence no convectional heat losses. No condensation, and therefore no destruction of the highly absorber coating. Annular gap air vent (9) l The annular gap air vent is located in the distributor pipe of the collector. l The annular gap air vent allows the solar collectors connected in series to be easily vented! NO WOOD NO INSULATION NO RUBBER SEALS 7

The reflector principle Each ingenious invention is based on a simple principe The angle of the sun on the collector surface changes continually with the Earth s movement. A standard flat-plate collector reaches its optimum efficiency when the sunlight hits the absorber directly at an angle of 90. However, this means that the majority of the sun's rays will strike the collector at an angle. Concentration in flat, weak radiation Due to its CPC geometry, the collector can still achieve usable temperatures even with weak sunlight at a low angle of incidence. l Based on the cylindrical design of the CPC reflector, the diffused part of the light is also absorbed (Kdiff= 0.87). 100% l This is important during the transitional period (spring and autumn), since up to 80 % of the sun s rays penetrate at an angle. SUNSET SUNRISE l Normal flat-plate collectors are irradiated from a single side and must be insulated on the back of the absorber to minimise heat loss. The CPC collector absorber is irradiated from both sides. Due to this double-sided irradiation, there is effectively no blind side to the absorber which would otherwise represent a net heat loss area. l The small absorber strip of the CPC collector also provides quick heating. SUNSET 50% 50% SUNRISE Your boiler will have a longer break due to the efficient use of the sun! The angle factor is the ratio of the optical efficiency from the current angle of entry to the vertical entry. The cylindrical shape of the CPC reflector allows it to absorb even diffuse light. Angle factor at 30 angle deviation = 1.10. l The vertical installation of the absorber allows the use of the inclined penetrating light. l The small absorber strip designates a small heat radiating surface and therefore less heat loss (radiator principle). l At the same time the small absorber strips of the CPC collector ensure rapid heating due to increased concentration. 8 Incidence Winkelfaktor Angle Modifier (-) (-) MORNING 365 DAYS AFTERNOON 1.10 1.02 1.0 Better energy absorption bessere Energieaufnahme Verlauf CPC-SOLARFOCUS SOLARFOCUS layout Verlauf FLAT-PLATE FLACHKOLLEKTOR COLLECTOR layout 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 EAST OST SOUTH SÜD WEST Winkelabweichung Declination

The benefits at a glance makes you independent l 10-year guarantee against condensation No insulation in the collector Only high-quality materials l Perfect exploitation of light at a low incident angle 87% diffusion factor l Suitable for all installation variants Flat construction l Universal application: Swimming pool heating, DHW preparation, heating support l Simple hydraulic connection Technical data S1 S1K Structure CPC-collector CPC-collector L = length [cm] 240 212.5 W = width [cm] 115.5 115.5 H = height [cm] 6.5 6.5 Surface area [m 2 ] 2.8 2.5 Aperture area [m 2 ] 2.5 2.3 Content [l] 1.6 1.4 Weight (empty) [kg] 55 50 Heat loss factor [W/(m²K)], [W/(m²K²)] A1 = 3,3 / A2 = 0,012 Conversion factor (according to aperture area) 0.74 Incidence angle modifier 30 / 50 1.1 / 1.02 Diffusion factor [Kdiff] 0.87 Heat capacity [J/m 2 K] 3950 Flow rate [l/m 2 h] 20-70 Pressure lost at 20 C and 50 l/m 2 h [mbar/m 2 ] 4.1 Glass cover Solar safety glass Max. operating pressure [bar] 10 TESTED ACCORDING TO EN 12975-1 and -2 Subject to technical changes 9

Sunny line sophisticated technology in detail: The collector is exposed to environmental influences such as wind, rain, dirt, UV radiation, snow loads and extreme variations in temperature over a period of decades. It is therefore all the more important that only high-quality materials are used that can withstand these adverse conditions. Materials such as wood, plastic and rubber do not offer the necessary resistance in the long term. Collector tray (1) l The 1.5 mm tight welded aluminium tray forms the foundation. l The high-quality finishing protects the inside of your collector for decades to come. l TECHNOLOGY l BENEFIT Absorber (2) l The highly selective coated full-area copper absorber impresses with a solar absorption rate of approx. 95% and a thermal emission rate of approx. 5%. l The floating absorber unit (blue-line absorber plate and copper heat transfer medium pipework are welded ultrasonically) guarantees the highest energy yields. Perfect appearance. Solar safety glass (3) l 4 mm low iron content prism structured solar safety glass. l Very high light permeability for high yields, impact and hail-resistant Special seal (4) l Permanently elastic UV-protected special seal. l Connects the tray, the glass and the glass holding strip. Diffusion-proof. Prevents the ingress of moisture and dirt. Glass holding strip (5) l Anodised aluminium special profile. l A UV and weather-resistant aluminium profile instead of a rubber seal ensures reliable protection of the glass edges. Guarantees the lasting connection of glass and tray. up to years Guarantee Guarantee according to guarantee pass Flush-sealing connections (6) l 1/2 external thread with flat seal. l The surface seals on the inside and outside of the tray are fastened plane-parallel with brass nuts and hermetically seal the tray against environmental influences. No rubber or plastic seals susceptible to weathering. Simple hydraulic connection of the collectors. 1 NO PLASTIC NO WOOD 10

makes you independent Backing insulation (7) l 50 mm low-binder mineral wool. l Thanks to the low binder content in the mineral wool, the insulation releases practically no gases on exposure to heat. 8 2 3 5 4 7 Schematische Darstellung: Sunny line -Flachkollektor Annular gap air vent (8) l The annular gap air vent is located in the distributor pipe of the collector. l The annular gap air vent allows the solar collectors connected in series to be easily vented! NO RUBBER SEALS 11

The benefits at a glance l 10-year warranty Strictly high-quality materials l Welded aluminium tray: Provides the best possible protection for the inside of the collector for decades to come l Highly selective full-area copper absorber 50 mm insulation for high efficiency, 4 mm low iron content solar glass, solar transmission 92% l Suitable for all installation variants (roof-integrated, on-roof, free-standing, wall mounted, etc.) l Universal application: Swimming pool heating, DHW preparation, heating support l Low installation costs Simple hydraulic connection Technical data Sunny 28 Sunny 21 Structure Flat plate collector Flat plate collector L = Length [cm] 240 178.5 W = Width [cm] 115.5 115.5 H = Height [cm] 8.5 8.5 Surface area [m 2 ] 2.77 2.1 Aperture area [m 2 ] 2.5 1.82 Content [l] 1.3 1.08 Weight (empty) [kg] 50 40 Heat loss factor [W/(m²K)], [W/(m²K²)] A1 = 3,4 / A2 = 0,011 Conversion factor (aperture area) 0.78 Flow rate based on [l/m 2 h] 20-70 Pressure lost at 20 C and 50 l/m 2 h [mbar/m 2 ] 4.1 Glass cover Solar safety glass Max. operating pressure [bar] 10 TESTED ACCORDING TO 12975-1 and -2 Subject to technical changes 12

Planning/design of a solar system makes you independent Persons and Intended Use Collector Area Storage Tank octo plus, fresh water module and solar system ca. 5,0 m² 300 liters DHW tank ca. 5,6 m² 300-400 litres DHW tank ca. 8,4 m² 300-500 litres DHW tank pellet top, with HYKO storage tank and solar plant 2-4 90 m² ca. 14,0 m² 800 litres Hyko Thermal Store 3-5 120 m² ca. 16,8 m² 1000 litres Hyko Thermal Store thermi nator II touch with stratified buffer storage tank, drinking water storage tank and solar plant 4-6 150 m² ca. 22,4 m² 1500litres buffer store and 400 litres DHW tank, These design recommendations should assist you in planning your system. The assumed values are for guidance only. Important parameters, such as hot water consumption, roof incline and aspect must be given individual consideration during the planning phase. The house energy index and type of heating are decisive in determining the coverage for partial solar heating installations. thermi nator II touch with stratified buffer storage tank, stratified load module, fresh water module and solar plant SOLARFOCUS, thanks to hundreds of standard schematics, can aid in your system, from conception and design to inception. 13

Everything from one supplier Plug-IN Domestic Hot Water Tank 3 DHW tank with pre-fitted pump set and solar control unit 3 Dual coil solar storage tank 3 Also available with high efficiency pump YOUR benefits l Simple assembly l Read-to-use DHW tank l Avoid assembly errors with the pre-assembled solar control unit and pump set. up to years Guarantee Guarantee according to guarantee pass Sensoren S3 Sensor 3 Sensor 2 Sensor 1 S2 S1 Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 300 l 500 mm 600 mm 1794 mm 0,8 m 2 1,52 m 2 148 kg 1892 mm 3 400 l 600 mm 700 mm 1591 mm 1,0 m 2 1,81 m 2 159 kg 1738 mm 3 500 l 600 mm 700 mm 1921 mm 1,27 m 2 1,95 m 2 230 kg 2044 mm 3 14

makes you independent Buffer Tank without solar coil 3 Buffer storage tank for large-scale solar energy systems 3 With external two-zone solar stratified charging module 3 Ideal in connection with a biomass boiler up to YOUR benefits l Serves as a storage tank for solar and biomass energy l Energy is supplied only when required l Avoids unnecessary boiler start-ups and low-load operation - longer service life for the boiler and a higher solar coverage rate for your solar energy system years Guarantee Guarantee according to guarantee pass Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 600 l /R 700 mm 900 mm 1700 mm 1,2 m 2 1,8 m 2 145 kg / 158 kg 1670 mm 3 800 l /R 790 mm 990 mm 1760 mm 1,8 m 2 2,4 m 2 170 kg / 192 kg 1740 mm 3 1000 l /R 790 mm 990 mm 2090 mm 2,4 m 2 3 m 2 202 kg / 232 kg 2100 mm 3 1250 l /R 950 mm 1200 mm 2100 mm 2,4 m 2 3 m 2 234 kg / 273 kg 2100 mm 3 1500 l /R 1000 mm 1250 mm 2125 mm 2,4 m 2 3,6 m 2 272 kg / 308 kg 2215 mm 3 15

Everything from one supplier Buffer tank with solar thermal system and fresh water module for external hot water in continuous flow mode and heating support 3 buffer tank with 2 coils für Schnellladung 3 Hygienic domestic hot water preparation with external module 3 Ideal in connection with a biomass boiler 3 Stratified charging pipe for the heating return flow 3 Stratified separation plate YOUR benefits l Serves as a storage tank for solar and biomass energy l Low space requirement l Simple, efficient system hydraulics up to years Guarantee Guarantee according to guarantee pass Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 500 l /R 650 mm 850 mm 1700 mm --- 1,2 m 2 103 kg 1670 mm on request 800 l /R 790 mm 990 mm 1760 mm --- 1,8 m 2 130 kg 1740 mm on request 1000 l /R 790 mm 990 mm 2090 mm --- 3,0 m 2 156 kg 2090 mm on request 1250 l /R 950 mm 1200 mm 2060 mm --- 3,0 m 2 189 kg 2090 mm on request 1500 l /R 1000 mm 1250 mm 2200 mm --- 3,6 m 2 210 kg 2210 mm on request 500 l /2R 650 mm 850 mm 1700 mm 1,2 m 2 1,8 m 2 131 kg 1670 mm on request 800 l /2R 790 mm 990 mm 1760 mm 1,6 m 2 2,4 m 2 169 kg 1740 mm on request 1000 l /2R 790 mm 990 mm 2090 mm 2,4 m 2 3,0 m 2 204 kg 2090 mm on request 1050 l /2R 790 mm 990 mm 2200 mm 2,4 m 2 3,0 m 2 209 kg 2170 mm on request 1250 l /2R 950 mm 1200 mm 2060 mm 2,4 m 2 3,0 m 2 240 kg 2090 mm on request 1500 l /2R 1000 mm 1250 mm 2200 mm 2,4 m 2 3,6 m 2 254 kg 2210 mm on request 16

makes you independent Buffer tank with solar thermal system, solar stratified charging module and fresh water module for external hot water in continuous flow mode and heating support 3 Buffer storage tank for large-scale solar energy systems 3 With external two-zone solar stratified charging module 3 Hygienic domestic hot water preparation with external module 3 Ideal in connection with a biomass boiler 3 Stratified charging pipe for the heating return flow 3 Stratified separation plate YOUR benefits l Serves as a storage tank for solar and biomass energy l Energy is supplied only when required l Avoids unnecessary boiler start-ups and low-load operation - longer service life for the boiler and a higher solar coverage rate for your solar energy system up to years Guarantee Guarantee according to guarantee pass Optionally with fresh water module or DHW tank Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating without insulation with insulation height coil coil height 6/4 possible 500 l/ps/sps 650 mm 850 mm 1700 mm --- --- 79/90 kg 1670 mm on request 800 l/ps/sps 790 mm 990 mm 1760 mm 97/112 kg 1740 mm on request 1000 l/ps/sps 790 mm 990 mm 2090 mm --- --- 114/132 kg 2090 mm on request 1050 l/sps 790 mm 990 mm 2200 mm --- --- ---/126 kg 2170 mm on request 1250 l/ps/sps 950 mm 1200 mm 2060 mm 146/162 kg 2090 mm on request 1500 l/ps/sps 1000 mm 1240 mm 2210 mm --- --- 163/182 kg 2210 mm on request 2000 l/ps 1100 mm 1340 mm 2440 mm 225/--- kg 2450 mm on request 3000 l/ps 1250 mm 1490 mm 2720 mm --- --- 280/--- kg 2705 mm on request 4000 l/ps 1400 mm 1640 mm 2900 mm 431/--- kg 2910 mm on request 5000 l/ps 1600 mm 1840 mm 2995 mm --- --- 501/--- kg 3010 mm on request 17

Everything from one supplier Fresh water module FWM 26-250 with high-efficiency pump 3 Flow rates: 26, 40, 50, 63, 75, 95, 150 and 250 l/min 3 Constant DHW temperature 3 Optimum stratification of the heating water in the buffer storage tank YOUR benefits l Hygienic domestic hot water preparation l Delivered ready for connection l Simple assembly l Low return temperatures l Cascade connection also possible 6 8 10 9 7 11 12 13 Fresh water technology Fresh water technology refers to the heating of DHW using the flow method. This means there is no need to store large volumes of hot water, yet completely hygienic DHW can be provided. External preparation with fresh water modules Fresh water modules transfer heat from a buffer tank to the DHW flowing through them with the help of a heat exchanger. The DHW temperature can be set as required and is maintained at a constant level via an electronic controller. Only the quantity of DHW you require at the exact moment flows through the fresh water module. 4 2 3 5 1 17 8 14 15 16 LEGEND: 1 Cold water inlet 2 Shut-off ball valve 3 Non-return valve 4 Dirt trap 5 Flow switch 6 Circulation non-return valve (optional Dual-circuit regulation Recirculation pump (optional) 7 Recirculation 8 Flushing option 9 Ultra-fast hot water sensor 10 Hot water 11 Buffer tank flow pipe 12 Plate-type heat exchanger 13 Wall mounting 14 Buffer circulation 15 Inlay non-return valve 16 Buffer tank return flow 17 "Plug-and-play" wiring 18 Flow rate/heat pump at 50 C buffer flow FWM 26 FWM 40 FWM 50 FWM 63 FWM 75 FWM 95 FWM 26 FWM 40 FWM 50 FWM 63 FWM 75 FWM 95 Buffer flow C 60 60 60 60 60 60 50 50 50 50 50 50 Cold water inlet C 10 10 10 10 10 10 10 10 10 10 10 10 DHW outlet C 45 45 45 45 45 45 45 45 45 45 45 45 DHW outlet l/min 26 40 50 63 75 95 15 25 34 46 51 65 Return temp. to buffer C 21 21 21 21 21 21 21 21 21 21 21 21 Max. output kw 60 84 130 157 180 230 37 61 98 120 139 181 Electr. power supply V 230 230 230 230 230 230 230 230 230 230 230 230 Connections 3/4 IT 3/4 IT 1 IT 1 IT 5/4 IT 5/4 IT 3/4 IT 3/4 IT 1 IT 1 IT 5/4 IT 5/4 IT Circulation conn. 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 1 IT 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 1 IT Height mm 770 770 960 960 1130 1130 770 770 960 960 1130 1130 Width mm 330 330 370 370 440 440 330 330 370 370 440 440 Depth mm 350 350 510 510 630 630 350 350 510 510 630 630 Weight kg 15 20 38 50 60 85 15 20 38 50 60 85 Flow Cold water inlet DHW outlet l/min Output Connections Circulation H/W/D mm Weight/kg FWM 150 60 C 10 C 45 C 150 390 kw 6/4 IT 5/4 IT 1050/900/450 135 FWM 250 60 C 10 C 45 C 250 650 kw 2 IT 5/4 IT 1050/1200/500 150

makes you independent Solar stratified charging module SLM 20-150 with or without fast charging mode: with high-efficiency pump 1 2 3 6 7 YOUR benefits l Optimum energy utilisation through stratified charging of the buffer storage tank l Minimum effort required for assembly l Delivered ready for connection 4 5 13 8 16 12 17 15 11 6 14 18 21 10 LEGEND: 1 Solar circuit safety valve 2 Solar circuit flow 3 3-way motorised switching valve 4 Solar circuit return 5 Solar circuit pressure gauge 6 Flow heat exchanger to buffer tank 7 Shut-off ball valve 8 Flow regulator 9 Inflow sensor for buffer tank 10 Wall mounting 11 Plate-type heat exchanger 12 3-circuit controller 13 Solar circuit pump 14 Venting valve 15 Buffer tank non-return valve 16 "Plug-and-play" wiring 17 Buffer tank charging pump 18 Flow regulator 19 Filling port 20 Flushing port 21 Heat exchanger return from buffer tank 22 Shut-off ball valve 23 3-way motorised valve 19 20 23 21 22 3 For optimum charging of the buffer storage tank on two levels 3 From 20 m² - 150 m² collector area Solar stratified charging module with fast charging mode A) B) Technical data, stratified charging modules SLMHE 20 SLMHE 40 SLMHE 60 SLMHE 80 SLMHE 100 SLMHE 150 Collector area m 2 bis 20 bis 40 bis 60 bis 80 bis 100 bis 150 Power kw bis 10 bis 20 bis 30 bis 40 bis 50 bis 65 SLMHE - primary pump Para 15/1-7 15/1-7 15/1-11,5 15/1-11,5 25/1-11 25/1-11 SLMHE - secondary pump Para 15/1-7 15/1-7 15/1-7 15/1-7 25/1-7 25/1-7 Buffer/solar connections 3/4 IT 3/4 IT 1 IT 1 IT 1 IT 1 IT H/W/D 770/330/350 770/330/350 960/370/510 960/370/510 1130/440/630 1130/440/630 Weight kg Approx. 25 Approx. 30 Approx. 45 Approx. 55 Approx. 65 Approx. 85 19

Large-Scale Solar Thermal Systems For which Kind of Applications? Areas of application for large-scale solar thermal systems: small businesses, industry, the catering and hotel industry, and the public sector How to start? Give us a call! Our friendly staff at the SOLARFOCUS Technical Support will be glad to assist you in planning and technical design of your large scale solar thermal systems. 20

makes you independent Pay Back? Large scale solar thermal systems today achieve pay back times of significantly under 10 years (with RHI or alike e.g. 2-7 years). With that such investments not only help to preserve and treat with care our environment, the energy produced essentially becomes free within a reasonably short periode. V ERLÄN GERTE GARAN TIEGEPRÜFTE QUALITÄT SOLARFOCUS 2013 21

INNOVATION ECONOMY QUALITY SOLARFOCUS is shaping the future with products that serve people and help the environment! SOLARFOCUS is concerned with the development, construction and distribution of solar and environmental technology products, with a focus on: Biomass heating, Solar thermal systems, Storage technology, Fresh water tecnology SOLARFOCUSis one step ahead: thanks to ongoing research, development and cooperation with renowned research institutes and partners, we have been able to show dynamic company development. Our products are only available from specialist dealers across Europe. Ongoing training and seminars with our partners ensure that plant operators receive project-oriented advice and professional plant installation. AWARDS such as: l Young Entrepreneur s Award l Austrian Innovation Award 1995 l Golden Pegasus Business Award l Nominated for National Award for Innovation l Voted Leading Upper Austrian Company for Brilliant Business Ideas l Upper Austrian Environmental Protection Award l Energy Genie Innovation Award 2003 l Haustechnik Award HVAC Award 2004 l Energy Genie Innovation Award 2011 l FORLENER Italian Innovation Award for energy-saving and eco-friendly technologies 2012 l Polish Innovation Award Zloty Medal 2012 and 2013 l Slovenian Innovation Award 2014 l Best Business Award 2014... and many more attest to our philosophy. 22

makes you independent The production ENVIRONMENT - FUTURE All our work is done by people for whom the environment and the use of renewable technology is a priority. SOLARFOCUS combines INNOVATIVE TECHNOLOGIES with MODERN PRODUCTION! 23

makes you independent Everything from one supplier Solar Log Wood Wood Chip Pellet Tested state-of-the-art technology G E N E H M I G U N G 19 94 GZ:312 P13/1 LAND STEIERMARK EN 303-5 CEN/TC 57 SOLARFOCUS Solar systems Biomass heating Storage technology Fresh water technology Your specialised dealer EN ISO 9001 certified makes you independent Solar thermal plants Biomass boilers SOLARFOCUS GmbH Werkstrasse 1 A-4451 St. Ulrich/Steyr e-mail: office@solarfocus.eu Tel.: +43 (0) 7252 / 50 002-0 web: www.solarfocus.eu Tel.: +43 (0) 7252 / 50 002-10 02/2015 Subject to technical modifications, typesetting and printing errors. The images used are symbolic photos. All use is prohibited without the written consent of the copyright holder SOLARFOCUS.