ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Similar documents
Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Ultrasonic Reflective Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Scale 0: 10 k Scale 50: 10 k (see note 2)

Ultrasonic Reflective Sensor

Model Number Structure

onlinecomponents.com

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Ultrasonic Proximity Sensor

Installation & Operation Manual

Original instructions JSNY7 Magnetic switch

CD6102 / CD6102 OC / CD6102-2

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Model Number Structure. Floatless Level Switch (Basic Type)

Duct Mount. Installation Instructions

CO2 Sensor User and Installation Guide

Annuciator Logic Controllers

- User Brochure tekmarnet 4 Setpoint Control 161

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Air Pump Up to 800 gallons

FW-RA-LED Remote Multiplex Annunciator Panels

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

- User Brochure Programmable Thermostat 510

FloorHeat Installation Manual

Preamplifier Power Supply PPS-02 user's guide

Original instructions Sense7-series Non-contact coded safety switch

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Clean Steam Generators

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

installation instructions Fan Tray System FTA-3/FTA-6

Installation & Operation Manual

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Duct Humidity/Temp Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Corrosion Resistant Fluid and Air Handling Systems.

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

HIH-4602-L Series Humidity Sensors

SKORPION Process Air Heater

MICRO SWITCH NT Series

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

OSRAM 1/25/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Design Criteria. Installation

Installation & Operation Manual

HOA6480 Series Barcode Sensor Infrared Products

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Room Humidity/Temp Sensor

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Protocol Station Remote Alarm

MODEL 4000A & 4001A ACCELEROMETER

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

MICRO SWITCH NT Series

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

Model 5190-F Temperature/Humidity Probe

Figure 1. Figure 2. See notes 1 and 2 below.

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Installation and Operations Manual

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Compact Equipment Warranty Policy

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

No Touch Door Release Exit Sensor ACA-NTEB

NT DUAL CHANNEL DISPLAY. User Guide

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Outside Air Humidity & Temperature Sensor

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

TrueClean ToteCleaner

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Single Station Remote Alarm

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

1/24/01 SYLVANIA Process Heat THREADED INLINE HEATERS , , , , , ,

Pressurized Filter Up to 1250 gallons

Model 5190-E Temperature/Humidity Probe

Humidity Monitor model 01080

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Easy installation in both new construction and retrofit

Models: SV1 (110V) SV1EU ( V) User s Manual. Register your product and get support at. v

OZX-300ST Ozone Generator

VS2000V Veterinary Vital Signs Monitor Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Transcription:

Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control. Employs high-polymer-resistive Sensor with superior durability. Compact and lightweight. Measurement ranges of 20% to 95% for humidity and 0 to 55 C for temperature. Ordering Information Dimensions Name Humidity Sensor Temperature/Humidity Sensor ES2-THB Humidity Sensor Module (See note.) ES2-M Model Note: All units are in millimeters unless otherwise indicated. Humidity Sensor ES2-THB Temperature/Humidity Sensor 50 22 Note: This is a replacement item. One Module is provided with the /-THB. Always attach the Humidity Sensor Module when using the /-THB. Approximately 7 VDC will be output for the humidity output if the Module is not attached or is incompletely attached. 50 Specifications Humidity Sensor section High-polymer resistive Humidity detection range 20 to 95% Humidity detection ±3% (25 C, 40 to 80%) accuracy Power supply voltage 24 VDC (See note 1.) Operating voltage range 85% to 110% of power supply voltage Current consumption 10 ma max. Humidity output 1 to 5 V (for humidity of 0% to 100%) Permissible load impedance: 100 kω min. (Use a 1:1 connection when connecting to an E5CC/E5EC/E5AC.) Temperature Sensor Platinum resistance thermometer Section (See note 2.) Temperature 0 to 55 C detection range Temperature output Pt100: 3 wire (See note 4.) Class JIS class B Communications cable length 5 m Operating temperature 0 to 55 C, humidity of 95% max. and humidity range (See note 3.) Storage temperature 20 to 60 C, humidity of 95% max. and humidity range (See note 3.) Degree of protection IP 20 equivalent Weight : Approx. 41 g (excluding cables) ES2-THB: Approx. 43 g (excluding cables) 5,000 ± 200 Cover 37 Heat-shrinking tube 4 dia. 37 5.5 dia. (25) 4 dia. 150 ± 20 ES2-M Humidity Sensor Module 21 Shield wire in transparent tube 12.7 Shield OUT G IN Humidity signal Note: 1. The maximum ripple voltage of 2% p-p max. The recommended power supply is the OMRON S8JX or S8VS. 2. ES2-THB only. 3. Do not use or store the Sensor for an extended period at a humidity of 90% or more. 4. Pt100 (JIS C 1604-1989) is used for the measuring elements. Set Pt100 for input sensor type of the Temperature. 17.5 Note: Firmly insert the connector all the way in when mounting the ES2-M to the Sensor. 1

Precautions for Safe Use ES2-THB Do not use the product in the following locations: Locations subject to water splashing or oil contact Locations subject to dust or corrosive gases Locations subject to icing or condensation Locations subject to direct sunlight Connection Examples Humidity Sensor ES2-THB Temperature/Humidity Sensor + 1 to 5 V or PT ES2-THB Yellow Green Brown A B B + Temperature input (platinum resistance thermometer) or PT Humidity input (1 to 5 V) or PT 24 VDC DC power supply GND 24 VDC DC power supply GND Shield (Ground separately.) Shield (Ground separately.) Cable Conditions Item Model ES2-THB Diameter AWG22 AWG24 Number of conductors 3 6 Shield Braided Braided Maximum conductive resistance (20 C) 60 Ω/km max. 92 Ω/km max. Finished outer cable diameter 5.5 mm 5.9 mm Note: Provide a separate cable according to the details listed at the left if the length of the supplied cable is insufficient. The cable can be extended to a maximum of 50 m. 2

Application Examples Temperature and humidity control for vegetable and fruit growing rooms ES2-THB Monitoring and data collection for clean rooms and storage locations ES-THB Alarm lamp Buzzer Factories and clean rooms Air conditioner Humidifier Heater Temperature Humidity control for constant-humidity warehouses and rooms for fermentation or ripening Temperature and humidity control for drying Humidifier or dehumidifier Office Warehouse ES2-THB Dehumidifier Temperature Humidity control for plant factories and greenhouses Exit side Dry air Sirocco fan Heater Exit Entrance Panel Meter Humidifier or dehumidifier Growing bed Office Plastic greenhouse ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 3

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2013.6 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: ES2-M ES2-THB