GUARDIAN : AUTOGUARD. User Manual

Similar documents
GUARDIAN : SOLO Marine Lone Worker Protection

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Application, Installation, Operation & Maintenance Manual

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

1126 Series Ceiling Mount PIR Motion Detector

The Remote alarm Panel, TYPE RAPv2

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

FarmGuard External Wireless Security

LS800S Intruder Alarm System. Engineering Manual

Campers Alert TM Portable System Hunters Alert TM Portable System

PIR-100B User Manual

Wireless Keypads LKP(E)S8M Series

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Solution Ultima 862 Operators Manual ISSUE 1.10

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

SMARTWALK DEMENTIA WANDERING SYSTEM

HDCVI PIR Camera User s Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Installation and user manual for the BiWire / Conventional Repeater Panel

Solution Ultima Series Operators Manual ISSUE 1.00

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO

1125 PIR Motion Detector

REMOTE CONTROL CAR ALARM SYSTEM

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

IMQ SPA scope as CertAlarm CCB and RTL. Last update: 12th June 2017

Combi B Alarm box. Mounting instructions

Wireless Keypad GKP-S8M

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

P162A Wired PIR Motion Detector

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

FEC400 Series. Installation Manual

WIRELESS CCTV. Oil, Gas and Renewables Site Security.

Installation and ZONES: Operation Manual. Model: ON STI-34108

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Solution 844 Operators Manual ISSUE 1.10

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

WIRELESS CCTV. Utility Site Security & Surveillance.

User Operation Manual

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Movement Detector GJD 300

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Totally Wireless Video Security

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

TRUST WIRELESS ALARM SYSTEM 200S

New Silent Alert Fire Safe System

Intruder - Fire - Water Combined Alarm

WM3000 WIRELESS MODULES

Wireless Alarm system s manual

MOBILE CALL GSM Alarm System User s Manual

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Premium 8 Zone Wireless Alarm Kit

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Pioneer-R16 Gas Monitor Operator s Manual

USER MANUAL CEF AP28 CONTROL PANEL

arm wire free solutions nurse call personal security fire alarms

Advanced DIGITAL Wired PIR Motion Detector

Masthead Repeater Installation Handbook

5 Sounds and Indications

KwêBeams Effective wire free outdoor early warning system

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

WARNING FIRE DOOR CLOSING

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

D-Tect 2 GJD300 Quad PIR Movement Detector

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

DIY Home Security Support 30 numbers wireless sensors

SECURIT 700L PLUS ENGINEERING MANUAL

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

ERS-3600B. PERS-3600B Personal Emergency Reporting System

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Intruder alarm panel Terxon MX Operating instructions

Silent Alert Fire Safe System

Installation & Programming Guide

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

MLS. ALPHA-PAGE-LT v5.3. Contact monitoring-paging system. installation/owners manual #AP-LT53. Micro Logic Systems. phone 866-MLS-FREE

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Lifeline Vi Clever, not complicated

Accessories for Alarm Systems in the Protect Series. Instruction Manual en/en

INSTALLATION GUIDE XTLN-WIFI PANEL

Detailed operating instructions

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

>WIRELESS> ALARM SYSTEM CR200

i on Compact Security System

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

LUX Hardwired - Installation Notes

Operating Instructions

Transcription:

2018 : AUTOGUARD User Manual

User Manual - Page 2 : AUTOGUARD Wireless PIR Intrusion Detection System User Manual 2

Contents User Manual - Page 3 Description Page No. 1. System Description 3 1.1 Scope of Supply 3 1.2 Detector Heads 3 1.2.1 General 3 1.2.2 Detection Zones 4 1.3 Receiver / Base Station 5 1.3.1 General 5 1.3.2 Alarm Outputs 5 1.3.3 System Code Transmission & Settings 6 1.3.4 Storage / Carry Case 6 2. Operation & Deployment 6 2.1 General 6 2.2 Detector Deployment 7 2.3 Receiver / Base Station Deployment 7 3. Detector Battery Endurance 8 4. First Line Fault Finding 8 3

User Manual - Page 4 1. System Description The Autoguard system consists of the following: - 1.1 Scope of Supply 1 x Carry / storage case 1 x 8 zone receiver / base station complete with telescopic antenna 8 x IP65 wireless detector heads 8 x Bungee securing straps 8 x Small tripods 1 x Mains / charging lead 1 x External antenna + mount 1 x User manual 1.2 Detector Heads 1.2.1 General Each detector head is a self-contained battery powered unit capable of transmitting a coded alarm signal to the central monitoring station. Any number of similarly coded heads or a repeater may be deployed in up to eight separate zones. Each sensor is capable of continuous operation for up to about 10 years (see Section 3. for battery endurance). Alarm response is by way of passive infra red detection (PIR). The active alarmed area is a 30m beam detection zone from the sensor faceplate. This gives excellent selective positioning control when deploying the units, for example, running along a ship s open decks, across a hatch entrance way, gangway access point. The units have a protective faceplate that also acts as an on/off switch. Note: Environmental conditions may reduce effective operating distance. Once the heads are activated they are ready for immediate deployment as and when required. Optimum detection is achieved when mounted approximately 2m above the deck, 4

User Manual - Page 5 positioned so that target movement will be across the zone rather than towards or away from the unit. It is important to avoid situations where two or more heads can trigger simultaneously as this can corrupt the coded transmission to the base station. Once deployed the detection zones can be walk-tested using the base station on battery power. Note: Once activated the head has a reset time of approximately 5 seconds after movement has ceased. Detector heads should be tested/activated periodically otherwise after prolonged periods of inactivity the heads go to sleep and will require the cover to be replaced to reset the detector. 1.2.2 Detection Zones The detection zones are indicated in the diagrams below: - 2m 2.4m 30m Detection Zone Side View 3m 3m 30m 5

Detection Zone Plan View User Manual - Page 6 1.3 Receiver / Base Station 1.3.1 General The unit is lightweight and is intended for mains operation but also contains an internal rechargeable battery capable of providing up to 36 hours of portable / standby use, walktesting for example. The battery is charged automatically during mains operation. The base station can also be powered by an external 12V DC supply, the internal battery is charged during this mode of operation (this facility is available by special order only). A single on/off switch, this illuminates the yellow power indicator next to the switch. The alarm sounder may be set to one of three modes Off, Steady or Pulse by way of the audible alarm switch. The eight bank LED display indicates an alarm condition by the individual zone numbers and remains illuminated until the reset switch is activated. The incoming alarm signal also triggers the sounder depending on the mode setting. The reset switch is used to extinguish any illuminated zone LEDs as and when required. It will also reset the low battery warning. The sounder will operate again if a new alarm is received from a zone already illuminated on the LED display prior to reset. The low Battery indicator illuminates on receipt of low battery warning transmitted by any of the detection heads. (See notes on Detector Head Batteries). 1.3.2 Alarm Outputs On the rear of the unit either a two pole terminal is fitted for providing a single common output for all alarms or a 15 pin socket is fitted for additionally supplying individual outputs for all eight alarms. The individual outputs can be used, for example, to position CCTV cameras, while the common alarm is suitable for activating existing alarm systems. Base Station Alarm Outputs:- 6

User Manual - Page 7 A universally normally open contact available via the two pole terminal posts. This output closes momentarily on receipt of a valid alarm signal from any of the 8 zones. 15 pin D Connector Pin 1 7 Alarms 1 7 Pin 9 Pin 8 & 10 14 Output common for all alarms N/C Pin 15 Alarm 8 These outputs are clean, normally open giving momentary closure when a signal is received from any zone. 1.3.3 System Code Transmission & Settings On activation each Autoguard detection head transmits two separate signal codes back to the base station. A third low battery code will be transmitted when required. 1.3.4 Storage / Carry Case When not in use the system may be stored in a hard sided case for protection and ease of transportation and deployment. 2. Operation & Deployment 2.1 General Guardian is a completely self-contained portable intruder detection system demanding minimal skill during deployment and subsequent operation. Capable of monitoring up to eight separate zones from a single monitoring unit it provides invaluable protection for a vast 7

User Manual - Page 8 range of security operations where mobility and versatility are the prime operational requirements. The system is supplied in a robust protective case complete with the following items: - A battery / mains operated base station monitoring unit complete with alarm outputs and integrated radio receiver. Eight coded battery powered detection heads, for portable deployment on the ship as required, capable of transmitting a radio signal back to the base station giving location number of alarmed area Operating instructions 2.2 Detector Deployment 1. Remove the detector from its carry case 2. Install the detector(s) in their final locations: i. On a suitable bracket on the ship s structure / side rails ii. Free standing on its tripod base iii. Attached to a convenient point by the bungee cords 3. Remove the protective cover from the detector 2.3 Receiver / Base Station Deployment Power-up the base station by connecting the mains lead into the back of the unit Switch On the base station, the mains LED will glow yellow indicating power is supplied to the unit (The charging LED may also glow if the internal rechargeable batteries are at a certain voltage level. This LED indicates the unit is also being charged; this will not affect the application. With all or several detector units deployed, you may have several alarms showing, this is normal because they would have been activated during installation. Activating the reset button should clear these alarms, if not, check the detectors set-up. It is always required that a walk-test be carried out on each detector location. Once the base station is activated you can choose whether you want the activation audio able or silent. In either mode the alarm LED will illuminate on alarm The base station can be operated for up to 36 hours on its own internal rechargeable batteries, although it is normal to run the system from mains. 8

User Manual - Page 9 3. Detector Battery Endurance Days Years No Alarms 5606 15.36 Days Years 1 Alarm / 24h 5461 14.96 Days Years 2 Alarms / 24h 5323 14.58 Days Years 10 Alarms / 24h 4431 12.14 Days Years 24 Alarms / 24h 3443 9.43 4. First Line Fault Finding Symptom Probable Cause Remedial Action Equipment appears dead Loss of power supplies 1. Check mains supply 2. Check internal batteries 3. Check internal fuses Low battery indication No alarm activation during walk through test One or more PIR detector batteries low. Damage or loss of wireless communications Replace onboard batteries (batteries soldered onto PCB) 1. Check PIR detectors for damage. 2. Clean PIR detector aperture 3. Check all antennas and connecting cables 4. Check batteries 5. Check supplies 6. Check alarm sounder Persistent alarm activation Defective PIR Check suspect PIR for damage Clean front lens Check for external interference 9

User Manual - Page 10 C-VIGIL Ltd : marine (CVM) The Barn, Bryntirion Road Bagillt, Flintshire N. Wales, CH6 6DS +44 (0)1244 879 279 general@cvigil.co.uk www.cvigil.co.uk 10