Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

Similar documents
OPERATION AND INSTALLATION

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

Flow Factor ~

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

UNIT MUST BE ON A DEDICATED ELECTRICAL CIRCUIT. Owner s Manual Models: 02117/02678 INFRARED HEATER POLE SET

HAZEL OWNER S MANUAL INSTALLATION GUIDE WARRANTY

INSTALLATION AND OPERATING INSTRUCTIONS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

Installation and Operation Guide

DHC-E TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN

Installation and Operation Guide

e Bath Fan with Light User s Guide

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

PRACTICAL USER S GUIDE FOR THE CORNER WALL MOUNTED ELECTRIC FIREPLACE

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

User s guide RUH series Economical unit heater Replacement component list included

15-Year Limited Warranty

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

DUST FREE CARBON Whole House Air Purifier

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Model: EF34. Owner's Guide & Installation Manual

FLCH4R Garage and Utility Electric Heater

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

52 SAN LUCAS CEILING FAN

VENTILATION FAN / LED LIGHT

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Electric Space Heater

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Quest Power Electric Heat EHS 62 Pro

SUTTON 52 CEILING FAN

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

User Manual / Installation Instructions

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

B.I.C.A Built-In Coffee Appliance

ELECTRIC STOVE HEATER Models: FS2213B

Installation and Operation Guide

HI Industrial Utility Heater HI Soleus Air International

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

52 BARSTOW CEILING FAN

Installation & Operation Manual for WarmlyYours Towel Warmers

IMPORTANT INSTRUCTIONS

52 BAYTOWNE CEILING FAN

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

OWNERS MANUAL MODEL: Steamer PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

Ceiling Mount Air Purification System

WAILEA OWNER S MANUAL

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

Ozone + UV Sanitation

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Wet/Dry Vacuum Kit

English. Your Model Number is: HD1500 IMPORTANT

IMPORTANT SAFETY INFORMATION:

WA A Aqua Sub Bottom-load Water Cooler

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

INSTALLATION FLOOR REGISTERS WALL REGISTERS

INSTRUCTIONS FOR OPERATION AND CARE OF

Installation & Operation Manual for WarmlyYours Towel Warmers

16 OUTDOOR MISTING FAN

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Installation Manual. Models 99168, 99169, 99170

breeze easytm model # F100-1W

30-YEAR LIMITED WARRANTY

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

InstaDry High-Speed Hand Dryer Guide Issued 10/26/17

OPERATION AND INSTALLATION

No Touch Door Release Exit Sensor ACA-NTEB

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

TSL hand dryer. installation + maintenance

BLOW DRY & GO HAIR KIT

Model: M630-44FDC CAUTION:

Active Thermal Management. SEC-1 Installation Instructions

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

CEILING FAN LIGHT KIT

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

48 TAYLOR CEILING FAN

IMPORTANT SAFETY INFORMATION:

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

EclipseDryer Guide. Effective 10/09

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Instantaneous water heater - Operation and installation instructions

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³).

ST. KITTS CEILING FAN

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

With Remote Control. English

IceBoss Pro. ElectroBoss IceBoss Pro Portable Home Ice Machine. Portable Home Ice Maker Ice Boss Pro Stainless

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Transcription:

GALAXY TM Series Automatic Hand Dryer Operating Instructions for the User & Installation Instructions for the Licensed Installer THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE GALAXY TM AUTOMATIC HAND DRYER. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH. STIEBEL ELTRON, INC. WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BECAUSE OF IMPROPER USE. FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS WARRANTY. NEVER REMOVE THE UNIT S COVER UNLESS THE ELECTRICITY IS TURNED OFF. MAKE SURE THAT AIR INLET AND AIR EXIT GRILLS ARE ALWAYS KEPT FREE TO ENSURE PROPER AIR FLOW. IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THIS HAND DRYER OR IF YOU NEED A COPY OF THE INSTALLATION INSTRUCTIONS PLEASE CALL OUR TECHNICAL SERVICE LINE AT 1-800-582-8423.

LIMITED WARRANTY STIEBEL ELTRON, Inc. warrants to the original owner that the GALAXY TM hand dryer will be free from defects in workmanship and materials for a period of FIVE YEARS from the date of purchase. Should any part(s) prove to be defective under normal use during this period, STIEBEL ELTRON, Inc. will be responsible for replacement of the defective part(s) only. Damage to the housing due to abuse is not covered by this warranty. STIEBEL ELTRON, Inc. is not responsible for labor charges to remove and/or replace the defective part(s), or any incidental or consequential expenses. Should the owner wish to return the entire unit for repair, the owner must first secure written authorization from STIEBEL ELTRON, Inc. The owner shall be required to show proof of purchase date by including a copy of the original invoice, and to pay all transportation costs to return defective part(s) or hand dryer for repair or replacement. IF YOU NEED TO RETURN A PART OR A HAND DRYER UNDER WARRANTY, PLEASE CALL US FIRST TO OBTAIN SHIPPING INSTRUCTIONS. REMEMBER TO SEND A COPY OF THE INVOICE WITH YOUR RETURNED PART. STIEBEL ELTRON, Inc. 17 West Street West Hatfield, MA 01088 Phone: 800-582-8423 Operating Instructions for the user In order to dry your hands most efficiently, please use the following procedure: min. 4" 10 cm shake off excess water over the wash basin place hands underneath the unit at a distance of 4" - 7" rub your hands together as if you were washing them Your hands will be dry within 25-35 seconds. The STIEBEL ELTRON GALAXY TM series hand dryers are equipped with an infrared sensor switch. This sensor will activate the unit when hands are placed underneath it. Approximately 7 seconds after the hands have been removed, the unit will automatically shut off. The sensor is the black rectangle located underneath the unit between the air exit and air inlet grills. The sensor switch will not work properly if it has been covered by gum or dirt. If the sensor is obstructed, the hand dryer will switch off automatically to prevent it from running continuously. Should the unit overheat, a safety high-limit switch will turn off the heating element. The safety high-limit switch resets automatically once the heating element has had a chance to cool down. Normal Care To clean the case use a soft cloth with a mild detergent if necessary. Never use any abrasive cleaners since they will scratch the finish of the unit. Never spray water or cleaning fluids directly on hand dryer. While cleaning the unit, make sure the electric eye switch is not covered. THE GALAXY TM HAND DRYER DOES NOT CONTAIN ANY PARTS SERVICEABLE BY THE LAY PERSON. IN CASE OF MALFUNTION PLEASE CONTACT A LICENSED ELECTRICIAN. FIG. 1 48" 120 cm

TM GALAXY with Plastic Housing Installation Instructions for the Licensed Installer DO NOT INSTALL UNIT WHERE IT CAN ACCIDENTALLY BE SPLASHED WITH WATER, ELECTRIC SHOCK MAY RESULT. WARNING: BEFORE BEGINNING ANY WORK ON THE ELECTRIC INSTALLATION, BE SURE THE MAIN BREAKER PANEL SWITCH IS OFF TO AVOID ANY DANGER OF ELECTRIC SHOCK. NOTE: THE CIRCUIT SHOULD BE EQUIPPED WITH A GROUND FAULT INTERRUPTER WHERE REQUIRED BY LOCAL, STATE OR NATIONAL ELECTRICAL CODES. 1. All electrical work must comply with national and applicable state and local electrical codes. 2. The GALAXY TM hand dryer must have its own independent circuit using 3 wire cable of the appropriate size protected by a correctly rated double pole circuit breaker. The GALAXY TM 1 unit for 110-120V requires a 20 amp circuit breaker and a gauge #12 copper wire. The GALAXY TM 2 unit for 220-240V or 208V requires a 15 amp circuit breaker and a gauge #12 copper wire. 3. Install unit so that the bottom is approximately 48" above floor. Unit should be at least 4" from a perpendicular wall. (FIG. 1, previous page) 4. Transfer the four mounting points to the wall by using the enclosed drilling template and drill mounting holes. 5. Remove the two screws at the air outlet grill and the screw on the locking bolt (FIG. 2). 6. Pull down locking bolt. Remove front part of housing (FIG. 2). 7. Install a 1/2" electrical connector in the back part of housing in the hole located below the wiring block. 8. Feed wires through connector; tighten clamp down on wire. Mount back part of housing to the wall. 9. The live wires must be connected to the slots on the terminal marked N/L and L. Ground wire must be connected to the wire terminal on the blower housing with the ground symbol. WARNING: AS WITH ANY ELECTRIC APPLIANCE, FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH. 10. Reinstall front cover, push up locking bolt and reinstall the three screws that were removed earlier. Technical Data GALAXY TM 1: GALAXY TM 2: 120V, 60 Hertz, 1850 Watts (Heating element 1800 Watts, motor 50 W) At 240V, 60 Hertz, 2000 Watts (Heating element 1950 Watts, motor 50 W) At 208V, 60 Hertz, 1500 Watts (Heating element 1450 Watts, motor 50 W) For dimensions see figure 3. The weight of the unit without shipping materials is 5.5 lbs (2.5 kg). 1 Fan Motor 2 Heating Element 3 Sensor 208 240V/60Hz 110 120V/60Hz 1 2 FIG. 2 9 1/16" 230 mm FIG. 3 1M ~ N/L L 9 7/8" 250 mm L N/L 3

TM GALAXY with Metal Housing Installation Instructions for the Licensed Installer DO NOT INSTALL UNIT WHERE IT CAN ACCIDENTALLY BE SPLASHED WITH WATER, ELECTRIC SHOCK MAY RESULT. WARNING: BEFORE BEGINNING ANY WORK ON THE ELECTRIC INSTALLATION, BE SURE THE MAIN BREAKER PANEL SWITCH IS OFF TO AVOID ANY DANGER OF ELECTRIC SHOCK. NOTE: THE CIRCUIT SHOULD BE EQUIPPED WITH A GROUND FAULT INTERRUPTER WHERE REQUIRED BY LOCAL, STATE OR NATIONAL ELECTRICAL CODES. 1. All electrical work must comply with national and applicable state and local electrical codes. 2. The GALAXY TM hand dryer must have its own independent circuit using cable of the appropriate size protected by a correctly rated circuit breaker. The GALAXY TM 1 unit for 110-120V requires a 20 amp circuit breaker and a gauge #12 copper wire. The GALAXY TM 2 unit for 220-240V or 208V requires a 15 amp circuit breaker and a gauge #12 copper wire. 3. Install unit so that the bottom is approximately 48" above floor. Unit should be at least 4" from a perpendicular wall (FIG. 1, on page 2) 4. Transfer the four mounting points to the wall by using the enclosed drilling template and drill mounting holes. 5. Remove one screw on the locking bolt (FIG. 4). 6. Pull down locking bolt. Remove housing (FIG. 4). 7. Install a 1/2" electrical connector in the back part of housing in the hole located below the wiring block. 8. Feed wires through connector; tighten clamp down on wire. Mount back part of housing to the wall. 9. The live wires must be connected to the slots on the terminal marked N/L and L. Ground wire must be connected to the wire terminal on the blower housing with the ground symbol. WARNING: AS WITH ANY ELECTRIC APPLIANCE, FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH. 10. Reinstall front cover, push up locking bolt and reinstall the screw that was removed earlier. Technical Data 7/16" 6 mm 1 Fan Motor 2 Heating Element 3 Sensor 208 240V/60Hz 110 120V/60Hz 1 FIG. 4 electronic 9 1/16" 230 mm FIG. 5 N/L L L N/L 10 1/2" 266 mm GALAXY TM 1: GALAXY TM 2: 120V, 60 Hertz, 1850 Watts (Heating element 1800 Watts, motor 50 W) At 240V, 60 Hertz, 2000 Watts (Heating element 1950 Watts, motor 50 W) At 208V, 60 Hertz, 1500 Watts (Heating element 1450 Watts, motor 50 W) 1M ~ 3 For dimensions see figure 3. The weight of the unit without shipping materials is 8.8 lbs (4 kg). 2 STIEBEL ELTRON, Inc. 17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 or (800) 582-8423 Fax: (413) 247-3369 HandDryerSupply.com 804-859-2498 sales@handdryersupply.com