Bedienungsanleitung. Fass-, Behälter- und Containerpumpen. F dichtungslos. F ,98% Fassentleerung. F

Similar documents
The sealless FLUX F 424

The sealless FLUX F 424

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

KEVA 20, 30 & 45 ATEX ELECTRIC VACUUM CLEANER OPERATOR MANUAL

OPTIBAR DP 7060 Supplementary Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

The Safest Connections...

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Technical Data. Dimensions

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Operating instructions Page 6

INSTRUCTION MANUAL (ATEX / IECEx)

Manual / Handbuch Spare parts list / Ersatzteilliste

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

SERVICE MANUAL. Freestanding cooker 500 and 600 / Range Gas- gas Electric CFSGSV14 CFSGWH14 CFSESV14 CFSEWH14

Drum and Container pumps Series 400 for low-viscosity media

BMW E36 Thermostat Removal And Coolant Flush

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Temperature Sensor TRG Original Installation Instructions English

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

Operating Manual Distribution box

Installation manual plugs and connectors QUICK-CONNECT (63 A)

SHR3D IT. Version 1.0 November English user guide

OPTIBAR P 1010/2010 C Supplementary instructions

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

OPTIWAVE X500 Supplementary Instructions

Technical Data. Dimensions

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Mechanical seals external, single or double, to DIN EN 12756

INSTRUCTION MANUAL W-400

Pneumatic agitator A MAN R

AJ-44 Rack Conveyor Dishmachine Maintenance Instructions. Changing Conveyor Direction

SMK 22 SMK SMK SMK 22-82

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

OPERATING INSTRUCTIONS

Before using your machine, you must familiarize yourself with all of its components.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

150MM ELECTRIC EARTH BORER

Sleeper Heater and Air Conditioner, Blend Air System 83.05

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Ireland. Australia. New Zealand

HAWK GLADIATOR SERIES. Equipment types:

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

FLUX AIR-OPERATED DIAPHRAGM PUMPS TYPE RFM AND RFML OF SOLID CONSTRUCTION

EN Instruction manual

OPERATING INSTRUCTIONS

3. DISCONNECT AIR CONDITIONING TUBE ASSY SST HINT: Disconnect in the same way as the cooler refrigerant suction hose No.1.

CBT LW MAINTENANCE GUIDE

DIRTY WATER SUBMERSIBLE PUMP

Tornado Operations & Maintenance Manual

PEPPERL+FUCHS GmbH

PJ130S High Pressure Cleaner

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Operation Guide for Hendor Pumps & Filters. 1. Introduction

SCHÜTZ ECOBULK WITH IMPELLER Operating manual

Vacuum leak detector VLX.. / Ex

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

Ireland. Australia. New Zealand

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

SUBMERSIBLE DIRTY WATER PUMP

Model: 1100 Float-Controlled Condensate Trap, PN 25

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

2.2. Type 90. Safety cabinets for active storage of drums

Safety vacuum drying oven for flammable solvents

Technical Data. Dimensions

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

USER MANUAL. PEDESTAL FAN (16 Inch)

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

ANTIBACTERIAL HAND VAC WITH UV LIGHT

START-UP AND CLEAN-UP PROCEDURES

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

G-10f/GCG-10f UPRIGHT COOLER

EN Instruction manual. gasprofi 1 SCS micro. The smallest laboratory gas burner with more safety. DIN 30665, part 1

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

HD Kompakt Service Manual

Installation instructions

Tornado Operations & Maintenance Manual

NRG NRG NRG NRG

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Part 2: Installation Instructions cl

SuperKlean Washdown Products

CONSTANT PRESSURE PUMP

Transcription:

Bedienungsanleitung Fass-, Behälter- und Containerpumpen F 424... dichtungslos F 425... 99,98% Fassentleerung F 426... Mischpumpe F 430... mit Gleitringdichtung Operating Instructions Page 13-23 Barrel and Container Pumps Type F 424... sealless F 425... 99,98% barrel emptying F 426... Mixing Pump F 430... with mechanical seal Mode d'emploi Page 24-34 Pompes vide-fûts Type F 424... sans joint F 425... Pompage efficace à 99,98% F 426... Pompe mélangeuse F 430... avec garniture mécanique

Possible Motor - Pump Combinations Only use motors and pumps in the following combinations. 1 2 3 Do not operate motor in hazardous locations. Do not use the pump for transferring flammable liquids. For use in hazardous locations only use explosion-proof electric motors which are approved for category 2 ( ZONE 1 ) or compressed air motors. For transferring flammable liquids only use pumps which are approved for category 1 ( ZONE 0). For use in hazardous locations only use explosion-proof electric motors which are approved for category 2 ( ZONE 1 ) or compressed air motors. Do not use the pump for transferring flammable liquids. Motors not explosion-proof Pumps Motors explosion-proof F 424 PP ; PVDF F 414 F 425 PP F 416 Ex 1 F 417 F 426 PP 3 F 416-1 Ex F 417 EL F 427 S F 416-2 Ex F 457 F 430 PP ; PVDF ; AL F 460 Ex F 457 EL F 460 Ex EL F 458 1 2 F 424 S F 460-1 Ex F 458 EL F 425 S FBM 4000 Ex F 458-1 F 426 S F 430 HC F 430 S 13

For use in hazardous locations For transferring flammable liquids class AI, AII and B only use pumps which are approved for ZONE 0. F 424 S-../.. F 425 S-../.. F 426 S-../.. F 430 S-../.. F 430 HC-../.. EC-Type-Examination Certificate PTB 00 ATEX 4108 X EC-Type-Examination Certificate PTB 99 ATEX 4001 X EC-Type-Examination Certificate PTB 00 ATEX 4109 X EC-Type-Examination Certificate PTB 00 ATEX 4110 X Only use explosion-proof electric motors which are approved for ZONE 1 or compressed air motors. F 416 Ex F 416-1 Ex F 416-2 Ex F 460 Ex F 460 Ex EL F 460-1 Ex FBM 4000 Ex Compressed Air Motor Compressed Air Motor Compressed Air Motor Commutator Motor Commutator Motor Commutator Motor Brushless Motor Observe EC-Type-Examination Certificate. The pump is not approved for stationary installation. The explosion-proof motor must definitely be outside the barrel and/or container. Only use electrically conductive hoses (see TRbF 131 part 2). The installation and operation must comply with the relevant Health & Safety Regulations. (In the Federal Republic of Germany these are "TRbF" and also "BG Chemie"). 14

Before starting operation in hazardous locations Connect the earth continuity conductors (earth wires) to the designated screw on the explosion-proof motor and pump. If the connection between motor and pump already provides a conductive path, one of the earth continuity conductors may be deleted. Connection to the mains via an explosion-proof plug device or an explosion-proof cable terminal box only. Ω Eelectrically conductive hose (see TRbF 131 part 2) completely mounted with swaged hose fittings to ensure a conductive path for the pump, hose and fittings. R < 10 6 Ω Ω The electrically conductive base ground has to be an integral part of the equipotential bonding system. If a conductive base ground is not available, earth continuity conductors have to be connected to all barrels and containers. Ω Ω Remove paint and dirt from all connection points of earth continuity conductors and containers to the electrically conductive base ground to ensure good conductivity. The use of the commutator motor in combination with the pump requires a complete and definite equipotential bonding. An equipotential bonding consists in an electrically conductive connection between the motor and the pump according to EN 50 014:1994-03 Paragraph 15 and DIN VDE 0165:1991-02 Paragraph 5.3.3. The pump has to be arranged in a way that no friction and impinge sparks form and that the operating conditions ensure safe operation. 15

Safety Instructions Only use the pump for its intended purpose. Never leave the pump unattended. The pump has to be used in vertical position only. When pumping liquids which contain solid particles in suspension, a suction strainer must be used. Before starting each operation, check motor, pump, hose and connections to ensure safe operation. Take care of external damages, too. To avoid damages on the pump and the container, do not roughly place the pump on the bottom. Constant use with the pump being placed directly onto the bottom of the barrel and/or container may cause wear on bottom of the barrel and/or container. Use a compression gland or an attachment clamp to fix the pump and make sure that it will not touch the bottom of the barrel and/or container. Install the pump in a way which ensures that it cannot fall into the container. Only use the pump with a suitable hose. Ensure that the hose is securely fixed to the hosetail. The pump should not be immersed deeper into the liquid than the outlet connection. Comply with all relevant safety instructions. Wear appropriate protective clothing. (Face shield, protective gloves, etc.). Please also take care of persons working in the nearer sourroundings. 16

Safety Instructions Comply with the operating instructions of the motor. Never operate the pump dry. The pump should not be exposed to the weather. Before removing the motor from the pump: Completely drain pump, flexible hose and hand tap. Never remove the motor from the pump as long as there is any back pressure. Always first drain flexible hose and hand tap. When used on pressurized containers, the motor may only be removed from the pump after having depressurized the container. Clean after each operation. Never store the motor in areas in which corrosive vapours exist. Before inserting the electrical plug into the socket or connecting the air supply hose to the air motor, ensure that the Start/Stop switch is set to "0" ( Stop ). Torque on F 425 / F 426 : F 425 S-41/34 F 426 S-41/38 0,8 Nm F 425 PP-50/34 F 426 PP-50/33 0,8 Nm 5 Nm 17

Starting Operation Available drive motors : Commutator motors F 417, F 417 EL, F 457, F 457 EL, F 458, F 458 EL, F 458-1, F 460 Ex, F 460 Ex EL, F 460-1 Ex Brushless motor FBM 4000 Ex Three-phase gearmotors F 414 Compressed air motors F 416 Ex, F 416-1 Ex, F 416-2 Ex 18 Make sure that the supply voltage corresponds to the voltage indicated on the name plate. When using air motors, please do not exceed the maximum operating pressure and always use a filter-regulator-lubricator unit. Put the motor onto the pumps. Never operate the pump unless the union nut between pump and motor has been firmly tightened by hand. Immerse the pump into the liquid and secure it in a vertical position by the use of a compression gland or a container clip. Always check the power supply cable for damage before starting operation. Keep solvents away from the power supply cable. Before inserting the electrical plug into the socket or connecting the air supply hose to the air motor, ensure that the Start/Stop switch is set to "0" ( Stop ). Insert the plug or connect the air supply hose. Switch on the motor. On motors F 417 EL, F 457 EL, F 458 EL and F 460 Ex EL the speed may be regulated by the adjustment knob (control of delivery rate).

Three-phase Gearmotor F 414 Repairs to three-phase gearmotors should only be carried out by suitably qualified personnel. Only use three-phase motors with a starter including an overload cut-out. Check direction of rotation of the motor. ( Direction of rotation according to the arrow on the motor ). In case of portable use of three-phase motors: Before inserting the electrical plug into the socket, ensure that the Start/Stop switch is set to "0" ( Stop ). Check direction of rotation when switching on the motor. ( Direction of rotation according to the arrow on the motor ). Comply with additional safety instructions which are contained with the terminal box of the three-phase gearmotor. Air Motor F 416 Ex, F416-1 Ex, F 416-2 Ex Before connecting the air supply hose to the motor, set the Start/Stop switch to "0" (Stop). ( On model F 416 Ex unlock locking mechanism of the on/off operating trigger ). Use a silencer or an exhaust air hose. Air consumption F 416 Ex, F 416-1 Ex, F 416-2 Ex : At 3 bar operating pressure ~ 7 l/sec. At 6 bar operating pressure ~14 l/sec. 19

Barrel Emptying up to 99,98% F 425 S-41/34, F 425 PP-50/34 As soon as no liquid will be delivered anymore : Close the flow back stop valve while the motor is still running. Switch off the motor. To achieve an utmost barrel emptying : Tilt the barrel. maximum immersion depth Always completely drain pump before storing. Valve OPEN Valve CLOSED Safety catch Hexagonal nut Adjusting lever F 425 S-41/34 20 Safety catch For dismantling insert screwdriver here. F 425 PP-50/34 Picture 1

Mixing Pump F 426 S-41/38, F 426 PP-50/33 When mixing electrically non-conductive liquids there is a risk that the circulated liquid will be charged electrostatically. Make sure that any ignition risk will be eliminated. When, during pumping and mixing operations, the mixing openings are above the liquid level, there is a risk of splash. On open barrels and containers splash guards must be installed. mixing pumping Safety catch Hexagonal nut Adjusting lever F 426 S-41/38 Safety catch Picture 2 For dismantling insert screwdriver here. F 426 PP-50/33 21

Cleaning after each operation Clean the pump by flushing a appropriate cleaning agent. The pump should not be immersed into the cleaning agent higher than the outlet connection. Pump and hose must be compatible with the cleaning agent. Do not use flammable liquids to clean the pump or motor. Please observe Safety Instructions. Dismantling of Pumps for Cleaning 1 Unplug the pump or disconnect the air supply hose. 2 Unscrew the union nut between pump and motor. 3 Remove motor from the pump. 4 Never store the motor in areas in which corrosive vapours exist. 5 Dismantling of pump as follows : 5.1 F 424 S-43/38, F 424 S-43/37 Z, F 424 S-50/45 Z, F 424 PP-41/36, F 424 PVDF-41/36, F 424 PP-41/35 Z F 424 PVDF-41/35 Z, F 424 PP-50/43 Z Unscrew foot piece. Lock coupling on the motorside of the pump by a wrench or a big screwdriver and unscrew the impellor. Take the inner tube out of the pump assembly. 22

5.2 F 424 PP-50/38,F 424 PVDF-50/38 Unscrew foot piece. Lock coupling on the motorside of the pump by a wrench or a big screwdriver and unscrew the impellor. Unscrew the outer tube. 5.3 F 425 S-41/34,F 425 PP-50/34, F 426 S-41/38 Please see pictures on page 17 and 20 On F 425 S and F 426 S: Release adjusting lever and hexagonal nut. Take off safety catch. On F 425 PP: Press out safety catch with a screwdriver. Set outer tube to position: F 425... to position "Valve OPEN" F 426... to position "mixing" Take the inner tube out of the pump assembly. 5.4 F 426 PP-50/33 Please see pictures on page 17 and 21 Remove threaded pin. Take out inner tube. Press out safety catch with a screwdriver. Set outer tube to position: "mixing" Take out the inner tube of the mixing tube. 5.5 F 430... Take the inner tube out of the pump assembly. 23