Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř

Similar documents
Development of high sensitivity radon detectors

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Development of the Groundwater Radon Detector

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

A new passive integrating detector for measurement of individual radon exposure at working places.

Detectors used in the intercomparison

Measurement system for detection of Radon in building

Quality and Technology - Made in Germany -

TPC BASED IMP. Limin Duan, Gas Detector Group. Institute of Modern Physics, CAS TPC tracker detector technology mini-workshop

Sensitivity to Thoron on Passive Radon Detectors

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

The LHCb Outer Tracker: Production & Ageing studies

W.E.T. (Water Extraction Techniques) Lab

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Technical Manual Ionisation Chamber MUSIC80

Radon monitoring system in the Kamioka mine

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Sergey Kiselev. SRC Federal Medical Biophysical Center

Introduction...1 Specifications... 1 Limitations... 1

EDELWEISS-III dark matter search: first results and future

On-farm cross-flow dryer. Cross-flow drying. Goal. The glass transition (Tg) line. Tempering

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Environmental Radiation Monitoring System

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

Ultraviolet radiation detector to obtain the rate of particles at different heights

Particle Detectors. Summer Student Lectures 2007 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

C-NRPP Quality Assurance Guidance for Radon Test Devices

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

LCTPC Setup at the DESY Testbeam. AWLC 14, Fermilab , R. Diener, DESY

Basic Properties and Application Examples of PGS Graphite Sheet

Controlling Static on an Unwinding Roll

Measurement Devices. Topic 5 - Audio 56

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

their original bags during the test period determine what background reading they might accumulate. The actual

ß-Aerosolmonitor FHT 59 C

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

Status Report about the TPC Detector and Module at CEPC

Aging Tests of of Full Scale CMS Cathode Strip Muon Chambers

Intercomparison s working group:

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Radiation Monitoring Equipment

Operation Manual. Rad-1-Cloud_Precipitation-v1

A Beam radiation monitor for the SVT based on CVD diamond sensors!

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

Status of the LHCb Detector. LHCC Open Session CERN, 27 November 2002 Werner Witzeling on behalf of the LHCb Collaboration

AEROSOL SEPARATION PARTICLE CHARACTERISTICS 27/11/2010

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Solar-Powered Hot Cup

GEM detectors activity at the Laboratori Nazionali di Frascati of INFN

Antoine Drouart DSM/DAPNIA/SPhN. Köln, 5 th of December,

Radon Entry Dynamics with Alpha Track Monitors or Just How Does the Radon Get In?

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

APR DESIGN FOR RECYCLABILITY GUIDELINES:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CONTENTS 1. 1 Ionizing Air Guns Overview Benefits Applications Models Ionizing Air Guns... 3

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

CONTENTS 1. 1 Ionizing Air Nozzles Overview Benefits Applications... 2

SINGLE COMPACT DISC METALLIZATION TYPE SINGULUS III / 3

STATUS OF THE LHC EXPERIMENTS.

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

ATLAS Beam Abort System Using CVD Diamond Sensors

Guide for Radon Measurements in Residential Dwellings (Homes)

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Effect of different air velocities on convective thin-layer drying of alfalfa for livestock feeding

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

R&D of GEM detector high rate for CBM Experiment at FAIR Muon Chamber R&D in India

MATERIAL EVALUATION REPORT STATIC DECAY, RESISTANCE AND TRIBOELECTRIC CHARGE GENERATION TESTING OF MERINO ESD LAMINATE SAMPLES MERINO INDUSTRIES, INC.

Detector Configurations for the MAJORANA Demonstrator

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

300KV Van de Graaff Generator Kit Builders Manual

Smoke Detection in Low Gravity Results from the Smoke Aerosol Measurement Experiments (SAME) Conducted on the International Space Station

Thermal Performance of a Loop Thermosyphon

Minco SmartHeat SLT Self-Limiting Thin-Film Heater Technology

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB. Development of a wavelength-shifting fiber-based photon detector for LBNE

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

Status Report of Active Space Radiation Detector, A-DREAMS-2 at NIRS

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Mega Mushroom Kit Setup

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Underground Air Radon Monitoring First Experiment

Development of the Micro Capillary Pumped Loop for Electronic Cooling

What you need to know

Highlights of Germanium Detector technology

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

RF0809 SERVICE FLASH. Frost Build Up On Upright Freezer Door Dyke SERVICE FLASH BRAND MODEL/SERIAL # CAUSE

Environmental radioactivity surveillance system of ANPA

Transcription:

Institute of Experimental and Applied Physics CTU in Prague Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř Fadahat Mamedov, Ivan Štekl, Karel Smolek 1

Outline Introduction Rn diffusion apparatus Apparatus for measurement of low activity of radon Radon emanation apparatus Conclusions & Future plans 2

Introduction Radon R&D for SuperNEMO experiment Goal : A(222 Rn) < 0.1 mbq/m3 in the tracking chamber Main sources of the radon background: Diffusion of the radon coming from outside the detector Emanation from the materials inside the detector Radiopurity of the gas in the tracking chamber ssible solutions : Isolation of the tracking chamber from the calorimeter part using thin foils with low radon diffusion coefficient - Rn diffusion apparatus Development of radon detectors sensitive to ~0.1 mbq/m3 - Rn sensitive detector Emanation measurements of some crucial materials that will be installed inside the detector (glass from PMT, wires )- Rn emanation apparatus Increase of the gas flow by a factor up to 10 to lower the radon level in the tracking chamber recycling of the gas Purification of the gas before entering the tracking chamber 3

Apparatus for measurement of radon diffusion The device uses the electrostatic collection of charged particles for the detection of Rn decay products Two stainless steel hemispheres separated by tested material foil Left side hemisphere with high Rn activity [activity Rn 38 kbq/m 3, dry air flow through Rn source 0.34 l/min], Right side hemisphere with low Rn activity [background 7±3 events per day], Airflow controlled by air pump and monitored by temperature and humidity sensors. For the evaluation of the Rn diffusion through tested foil a long term measurements of Rn activities on both sides is needed. Lowest Limit of Detection (LLD) of the device reaches the sensitivity of the radon diffusion D at the level ~10-18 m 2 s -1 Efficiency of detector 40% [RH=0% 4 kv] 1/2 - Left/right vessel, 7 - Air pump, 0.34 l/min 3 - Radon source, 8 - Air dryer 4 - Sensors of temperature, humidity, and pressure, 5 - Flow-meter, 6 - Air buffer, 4

Measurement of background in radon diffusion apparatus: B = 7.0 ± 3 counts/day Counts/6h Time [h] 5

Measurements of Rn diffusion for different type of materials for the SuperNEMO detector Foils: Mylar, TROPAC III, EVOCH, PET, HDPE, Mylar junction, TROPAC III junction, Bovlon, EVOCHPET, Al foils, Nylon,.. Glue :SILICON, STYCAST 1264, Glue, SBR, Emultex 5018, Glue PE, Synthomer 47B40 PE. Rubbers: RTV615, RTV ECOO, WB 50T, UR 6, PVC,. Sealing of construction part of SuperNEMO detector: Valve PINDelrin Glass 52mm 32mm Sheets: Delrin, PLEXY,. 6

Counts [in 2h] Measurement of Rn diffusion through 50 µm NYLON film Rn suppression factor C1/C2 > 76 500 Diffusion coefficient D =4.7 10-16 m 2 s -1 7

Experimental results of radon penetration through different types of materials. C1 and C2 are concentrations of radon in the left and right chamber of the radon diffusion apparatus. Providing of the coefficient of diffusion D or the diffusion length L for the junctions of two materials is not meaningful, therefore we do not provide them in the table. Thickness d [µm] C 1 /C 2 C 1 /C 2 normalized to 15 µm Diff. coefficient D [10-12 m 2 s -1 ] HDPE (2 layers) 2 144 3.5 1.1 19 3000 TROPAC III 102 > 8300 > 600 < 0.0043 < 46 Mylar (2 layers) 2 20 > 9100 > 2300 < 0.0012 < 24 EVOH (2 layers) 2 15 > 31000 > 8900 < 0.00035 < 13 EVOH PE 125 165 20 0.013 254 Silicon 2 800 2.5 1.008 320 12 000 RTV 615 2 100 1.33 1.002 1084 22 747 RTV 116 (on stainless steel sheet ) 3.5 25 1.1 7201 58599 RTV ECOO 2 000 1.5 1.002 1 030 22 200 STYCAST 1264 2 000 > 7268 > 6.9 < 0.43 < 455 PET 1 000 > 41 136 > 35 < 0.076 < 190 PLEXY 1 000 1 617 9.8 0.29 371 Butyl 1 000 2.5 1.02 1180 7 496 Emultex 518 (6 µm) PE (11 µm) 17 > 9 985 > 8 261 < 0.00038 <13 WB 50T 50 12.5 4.4 0.74 593 RTV 615 with 60% resin Stycast 1 000 1.3 1.005 521 15 765 Mylar junction 20 110 85 0.030 120 TROPAC junction 102 > 6300 > 500 < 0.0051 < 50 PVC 2mm 2 9 1.1 44 4 600 Derlin sheets 1 47 860 36 0.072 186 Resin UR6 manufacturer KEMICA 2.1 159 000 15 0.19 297 Neoprene 1 15.6 1.2 12.4 2 430 Bovlon film 0.015 4.0 4.0 0.84 633 SBRAcrylic on stainless steel sheet 2 6 680 47 16 2 760 Emultex 518 on stainless steel sheet 2 >20 900 >126 <5.9 <1 680 NYLON 50 76 500 6 380 0.00047 158 Synthomer 47B40PE 700120 739 8.3 0.27 406 Diff. length L[µm]

First prototype of the hemispherical detector for measurement of low activity of radon -Volume 50 l -Inner surface is electrochemically polished to level of 0.4 µm -HV up to 12kV Efficiency of radon detection 32% ( 8kV) PIN diode First prototype of the hemispherical detector with volume of 50 l (outer view on the left), schematic view of the HV feedthorough (middle) and conduction of PIN diode (right) 9

Measurements of background for the hemispherical detector Energy spectrum measured at the beginning of background measurement (5 Bq/m 3 ) Events[per day] 218 214 Energy spectrum measured after two months. Energy[MeV] Background is 11±1 events/day in the ROI (6.2-7.8 MeV, 214 ) Events[per day] Energy[MeV] 10

Construction of radon detector with different volume Detection volume of 50 l, 20kV MEASUREMENT TIME DETECTION LIMIT 1 day 10 mbq/m3 7 days 3,5 mbq/m3 30 days 1,6 mbq/m3 79 days 1,0 mbq/m3 Detection volume of 200 l 11 Detection volume of 85 l

Apparatus for measurement of Rn emanation PIN diode - - - - 212 sitive ions 216 216 212 216 216 212 212 216 212 216 216 212 Emanation 220 Rn 220 Rn 220 Rn 220 220 Rn Rn 220 Rn Setup is based on diffusion apparatus Made from stainless steel Volume of detector 6 l, HV= 2.5 kv, PIN diode Background is B = 7.2 ± 0.5 events/day in the ROI Material (6.2-7.8 MeV, 214 12)

Examples for measurement of radon emanation from materials Thoron emanation from tungsten electrodes Measurements of Rn emanation from glass pellets Events per[6h] Time[h] 13

Conclusions & Future plans 1) The radon diffusion apparatus identifies suitable material candidates for the inner and outer radon shielding for the SuperNEMO detector. Several candidates for outer shielding e.g. TROPAC, EVOH (more layers),.. SBR seal, Resin UR6 Candidates for inner shielding (tracker) Nylon (influence of humidity), EVOH, Emultex 518 (with PE), SBR seal 2) Measurement of radon background in the SuperNEMO detector The radon background in the detector will be extremely low. Our detector is able to measure activities ~10 mbq/m 3 in 1 day measurement 3) Measurement of radon emanation from materials Measurement of different types of materials for the SuperNEMO detector Future plans Increase of radon detector sensitivity to ~0.1 mbq/m3 for use with radon concentration line. 14

Thank you for your attention 15