Owner s Manual for Swimming Pool Heat Pump

Similar documents
OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S Manual PRINTED IN CANADA 10/2009

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Owner s Manual PRINTED IN CANADA 05/2009

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

INSTALLATION AND USER MANUAL

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

SWIMMING POOL HEAT PUMP

Swedish design and manufacture since 1967

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Surna 25-Ton Chiller Operating & Maintenance Manual

Q&A 2016 Practical Guide

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

OPERATING INSTRUCTIONS

Owner s Manual. Operating Instructions The Controls on Your Dehumidifier Care of Product

Quick Start Guide. For product manuals and further installation / operation procedures visit

WATER HEATER FOR POOL & SPA

Appliances SAVE THE SALES RECEIPT! It is your proof of purchase and required for the limited warranty to apply.

Dehumidifiers. Déhumidificateur. Deshumedificador. GEAppliances.com. Safety Instructions... 2, 3. Owner s Manual

INSTALLATION AND USER MANUAL

HP50HA ABG Heat Pump

User Manual / Installation Instructions

INSTALLATION AND USER MANUAL

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Swimming Pool Heat Pump

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

INSTALLATION AND USER MANUAL

Owner s. 18 Misting MF18W. To view

WATER HEATER FOR POOL & SPA

OWNER and INSTALLATION MANUAL

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

AquaCal Operation Manual

BEFORE FIRST USE: TABLE OF CONTENTS

INSTALLATION/OPERATING INSTRUCTIONS. AQUEFIER POOL HEATERS Model TK125T

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

User Manual. Wine Cellar

USER GUIDE 30L 40L 50L. Instruction Manual. IFRIDGE30 (30L), IFRIDGE40 (40L) and IFRIDGE50 (50L) CAPACITY CAPACITY CAPACITY

13500 BTU RV Air Conditioner Installation and Operating Instructions

To make planning your kitchen even easier, IKEA has developed a complete line of high quality major appliances that are designed for everyday use and

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Operator s Manual. IP-100 Immersion Probe Cooler

Instruction Manual Item No.: V~, 60Hz

Owner s Manual Super-Slim Four-Way Cassette

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

ThermoSaver TM Hot Gas Defrost System

AquaCal Operation Manual

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

Instruction Manual Item No.: V~, 60Hz

KSD-35 DR11 KUE-35 DVN11

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

User Manual

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for future use.

Owner s. Coolerr. comply. To view

AquaCal Operation Manual

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Harmo Powerpack Horizontal Units Installation & instruction manual

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

AquaCal Operation Manual

Split Portable Air Conditioner

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

Installation and Operation Guide

Swimming Pool Heat Pump

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY


Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

Mira Platinum Wireless Controller

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36


5) Do not start or stop the unit by inserting or pulling out the power plug.

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

Portable Dehumidifier with Internal Pump

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Installation and Operation Guide

Prime Chiller Modular Upgradable Chiller

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

Outdoor Beverage Center

Instructions for installation and use English. More documents on: H B /09

Portable Refrigerator

Swimming Pool Heat Pump

12,000 BTU Evaporative Portable Air Conditioner

Transcription:

Owner s Manual for Swimming Pool Heat Pump FC Series nirvanahp.com

CONTENTS How it works 1 Installation 2 3 Settings 4 5 6 7 Start-up 8 Winterizing 9 Maintenance 10 Troubleshooting 11 12 13 Warranty 14

HOW IT WORKS Congratulations on the purchase of your Nirvana heat pump. It was designed and manufactured in Canada and is renowned for its efficiency and reliability. How it Works This heat pump is equipped with a large surface evaporator that allows heat to be extracted from surrounding air. This heat is transferred to the pool water by the titanium heat exchanger. This method generates substantial energy savings compared to conventional electric resistance, natural gas or propane pool heaters. IMPORTANT FACTS Your pool pumps should always be on when your heat pump is in operation. Using a pool heat pump to continuously maintain water temperature at a constant 80 F or 27 C from May to September costs approximately 1/6 of what it would cost with a conventional heater. 1

INSTALLATION Installation Site To get the best results from your pool heat pump, its location is critical. The heat pump takes hot air from its surroundings and transfers it to the pool water. To get the best performance from your unit, there must be a minimum clearance of 48" (120cm) above the heat pump and 24" (60cm) around it (image 1). The heat pump must be installed on a level surface. We recommend a concrete slab or patio stone that is detached from the foundation of the house. The heat pump should not be installed in an enclosed space (e.g., under a deck or in a shed ). 48 24 24 Image 1: Minimum Clearance Bypass System Although a bypass system is not necessary for your heat pump to work properly, we strongly recommend the use of a bypass system (image 2) to make the maintenance and winterizing of the heat pump easier. Image 2: Suggested Bypass System Electrical Connection WARNING! The electrical connection should be done The by electrical a professional connection according should to national, be done state or by provincial a professional and city Codes. according to national, state or provincial and city codes. The unit should be connected with a sufficient GFCI. The electrical diagram is located inside the electrical panel. Connection requires a 240V single phase panel. 2

INSTALLATION Filter Chlorine or Other Sanitizer One-Way Valve Pool Out In Bypass System (Recommended) Pump (Minimum 1.5 HP Recommended) Image 3 Water Connection 1. Connect the water line from the swimming pool filter to the water inlet connector located on the base of the heat pump. 2. Connect the water line returning water to the swimming pool to the water outlet connector on the base of the heat pump. 3. Once all the connections have been made, turn the circulating pump to ON to check water pressure and to ensure hat connections are watertight. The flow rate should be at between 40 and 80 gallons per minute (gpm) or 9-18m^3/hr. Higher flow will improve heat pump performance. Connections from your heat pump to your pool water line can be done either by a certified technician or by you. It is an easy task that requires rigid or flexible 2 PVC pipes (image 3). WARNING! The electrical connection should be done The by a Nirvana professional heat according exchanger to national, works state best or at provincial higher flow and rates city of Codes. up to 80 gpm (18m^3/hr). 3

SETTINGS Electronic Display Enter menu, OR return to previous display WITHOUT confirming changes. Actual water temperature Heat mode setting (Quiet, Smooth, Boost) Target temperature Heat pump is in Pool mode Return to previous menu and confirm changes. Change value Select sub-menu Power ON/OFF Heat pump is in SPA mode Compressor is ON Image 4: Button Layout 4

SETTINGS Image 5: User Menu User Menu -Set Temperature - Set the desired temperature of the POOL or the SPA. -Pool or Spa Mode - Change between POOL and SPA modes. Image 6: Set Temperature Sub-Menu -Heat Mode - (Variable Speed Fan Models Only) Change Between speed settings: Quiet Mode - Keeps the Fan Speed Lower to reduce noise when it is warm outside - This mode does not work below 60F - If Temperature Drops below 60F, Heat Pump will return to SMART Mode. Quiet Mode Reduces heat pump BTU Output due to reduced fan speed. Smart Mode - Varies Fan Speed according to Outside Temperature to produce the best COP Possible. As Temperatures get colder, Fan speed increases. As Temperatures get Warmer, Fan Speed Decreases, Boost Mode - Fan Speed is increased to improve BTU output of the heat pump. 5

SETTINGS -Daily Timers: Timers ON/OFF This activates the heat pump timer function - Make sure clock is set. Start Heating Time - Set the time of day when the heat pump turns on. The heat pump relay (optional) is activated whenever heat is ON. Stop Heating Time - Set the time of day when the heat pump turns off. Start Pump Time - Pump relay (optional) set the time of day when the pool pump turns on. Stop Pump Time - Pump relay (Optional) Set the time of day when the pool pump turns off. Set Clock Time - Allows User To Set Clock Time (Must be done every time the power is cut to the unit). -Settings: Min Outside Temp - Allows User to set the minimum outside temperature that the heat pump will turn on. This allows users to save energy by not heating on days when temperatures are too low or avoids heating at night. Note that this setting may prevent the pool from reaching set temperature at certain times of the year. Fahren. or Celsius - Select temperature units Fahrenheit or Celsius. Change Language - Set display language. 6

SETTINGS Actual refrigerant temperature Refrigerant temperature needed to exit defrost mode Actual water temperature Unit is in Defrost mode Image 7: Defrost Mode Defrosting Mode Defrosting is a normal cycle that takes a few minutes. During this process, the fan will be working while the compressor will be turned off. WARNING! The electrical connection should be done Improper by a professional installation, according adjustment, to national, service, state maintenance or provincial or and use city can Codes. cause fire, electrical shock or other conditions which may cause injury or property damage. Consult a qualified technician or service agency for information or assistance. All service calls under warranty should be authorized by Nirvana Heat Pumps Inc. 7

START-UP Image 8: Langelier Index Start-Up Nirvana Heat Pump Electric Box 1. Inspect the unit to ensure that it is in good operating condition. 2. Clean the swimming pool filter. 3. Balance the pool water according to the Langelier index. 4. Reconnect all the water inlets and outlets. 5. Turn on the circuit breaker. Silensor Pump Connection 8

WINTERIZING WARNING! The electrical connection should be done Water by a connections professional according to the to heat national, pump state should or provincial be disconnected and city Codes. during winter in order to allow the heat pump to fully drain itself. The winterization of the heat pump must be done before the air temperature falls below 0 C. WARNING! The electrical connection should be done Your by unit a professional should never according be to tilted national, more than state or 30-35, provincial even and city during Codes. transportation. Winterizing 1. Turn off the circuit breaker. 2. Drain the heat pump then loosen up all of the water connectors. 3. Rinse the inside of the heat exchanger s cylinder with a stream of tap water for about 15 minutes to remove any chlorine residue that could damage the heat exchanger. Block water inlet and outlet with a cloth or some plastic to prevent mice or other animals from entering the unit. For better protection, cover your heat pump with the Nirvana winter cover; call your dealer for details. 4. Tilt back the unit slightly to drain all the water from the unit. 9

MAINTENANCE WARNING! The electrical connection should be done To by prevent a professional injuries, according death, to or national, property state damage, or provincial read and city follow Codes. all of the instructions and warnings. Safety Tips Always disconnect the heat pump before: Opening the access door, Cleaning the cabinet or evaporator. Never sit or place a heavy object on top of the heat pump. Never put objects in or on the protective grid to prevent injuries or damaging the unit. A heat pump requires professional maintenance and repair. All do-it-yourself repairs on a unit under warranty may void the remainder of the manufacturer s warranty. Maintenance Maintenance or adjustments other than those recommended in this owner s manual should not be attempted. Contact your dealer for any questions or problems you may have concerning your unit. Regular Maintenance 1. Inspect and clean the pool filter regularly to ensure adequate water flow to the heat pump. 2. Inspect the evaporator and rinse it using a garden hose. Wash from top to bottom with a stream of water to remove any grass, leaves or other objects that could obstruct the evaporator. 3. Clean the heat pump casing with a mild soap (dish soap). Do not use any abrasives or bleach. 4. Inspect the skimmer regularly. Never use the skimmer to add chemicals to the pool. The PH should be maintained between 7.2 and 7.8. A higher level could result in damage to your unit and could void the warranty. 10

TROUBLESHOOTING PROBLEM CAUSE WHAT TO DO WATER FLOW ERROR CHECK WATER FLOW INSIDE HEAT PUMP DEFROST MODE ERROR LOW REFRIGERANT PRESSURE LOW PRESSURE FAILED 3 TIMES IN 1 HOUR RESET THE BREAKER ERROR HIGH REFRIGERANT PRESSURE HIGH PRESSURE FAILED 3 TIMES IN 1 HOUR RESET THE BREAKER The water flow inside the heat pump is insufficient; The bypass valves are in the wrong position; There is no water circulation inside the heat pump; The flow switch is defective. The heat pump is in de-icing mode. This Is Normal if outside temperatures are low Ventilation on the evaporator is insufficient The fan does not work Refrigerant leak The outside temperature is too low The heat pump low switch has cut off three (3) times in the same hour for one of the reasons above.(code LP) The water flow inside the heat pump is insufficient The bypass valves are in the wrong position The water exit is blocked There is an obstruction in the refrigeration circuit (piping blocked) The heat pump high pressure switch has cut off three (3) times in the same hour for one of the reasons above (code HP) Make sure the circulating pump works; Make sure the bypass valves are properly positioned; Check the skimmer (no obstruction). Wait until the end of the de-icing cycle. The heat pump will restart automatically. Check that the evaporator is not obstructed by pollen, grass, leaves; see the user s manual for safety and maintenance tips; Be sure there is enough free space around the heat pump (see the Installation Guide); Check that the fan is powered ON The heat pump will not re-start after one of the protection devices shuts it down for the third time in the same hour Close the circuit breaker to reset the heat pump Check whether there is adequate water circulation inside Check that the bypass valves are properly positioned Check if there is an object obstructing the water hose The heat pump will not re-start after one of protection devices shuts it down for the third time in the same hour Close the circuit breaker to reset the heat pump 11

TROUBLESHOOTING PROBLEM CAUSE WHAT TO DO NO CONNECTION DEFROST TEMPERATURE PROBE OPEN The display and main boards are not communicating. The de-icing sensor is not properly connected or is not receiving power Close the breaker switch and reopen it. If the problem is not resolved, the digital control will have to be changed. In this case, call your dealer. Call your dealer. DEFROST PROBE SHORT CIRCUIT WATER TEMPERATURE PROBE OPEN WATER TEMPERATURE PROBE SHORT CIRCUIT AIR TEMPERATURE PROBE OPEN AIR TEMPERATURE PROBE SHORT CIRCUIT The fan is functioning, no code is displayed and the compressor does not start The de-icing sensor is defective Call your dealer. The water temperature sensor is not properly connected or is not receiving power The water temperature sensor is defective The air temperature sensor is not properly connected or is not receiving power Call your dealer. Call your dealer. Call your dealer. The air temperature sensor is defective Call your dealer. Electrical problem in the compressor circuit Capacitor defective Compressor defective Call your dealer. 12

Before placing a service call There is always a possibility of condensation, especially on days with a high humidity level. If you see water near the heat pump, there s a good chance it comes from condensation. To make sure it is water from condensation you can shut the heat pump off, leaving the circulation pump running. Within a few hours, if you see that the water around the unit is drying up, it is indicative of normal condensation. Before calling your dealer, follow the steps below to avoid any unnecessary cost for a service call not covered by warranty. 1. Make sure the breaker is ON, the fuses are functional and the heat pump is connected properly (green light on the unit). TROUBLESHOOTING 2. Make sure that the circulation pump is running at full capacity, has sufficient flow and that the filter is clean. 3. Make sure that the pressure gauge on your filter indicates sufficient flow (between 10 and 15 PSI) If it does not indicate 10 to 15 PSI, start a backwash. 4. Make sure that the water inlet and outlet are open and bypass valve is closed. 5. Check whether the temperature set is higher than the actual pool temperature. 6. Check that the plumbing is positioned in a way to enable sufficient water flow. 7. Check that the evaporator is not obstructed by pollen, leaves, grass etc. (See maintenance for washing instructions). 8. When the temperature goes down to about 7 o C, the heat pump may switch to de-icing mode; it will then start a cycle that stops the compressor while letting the fan continue running. Once the cycle is complete, it will resume normal operation. 9. Frost may appear on the evaporator during cold weather and this is normal; however, if there is ½ of ice or more on the evaporator, contact us immediately. If your heat pump does not operate properly after following these steps, contact your dealer. All replacement must be made using Nirvana parts to maintain your heat pump performance, durability and safety as well as keeping your warranty valid. 13 WARNING! DO NOT modify or remove a safety device. The manufacturer disclaims all responsibility if installation or maintenance instructions are not followed or if electrical or mechanical components and / or safety devices have been modified in any way.

WARRANTY Warranty Please visit our website www.nirvanahp.com to register your unit online within 10 days after the installation of the unit. This information could be needed in the event of a product recall. To help you keep the information you might need in the future, please record the information below. Model : Serial number : Installation date : Make sure you keep your original invoice. A proof of purchase is required on any service call request. Manufacturer s Limited Warranty Nirvana Heat Pump Inc. Offers a limited warranty against defects in the operation of the heat pump. This warranty becomes effective upon installation and is valid for new heat pumps only (residential use only). A proof of the date of installation will be required. The heat pump must be installed according to manufacturer s specifications and must be operated under normal conditions of use as described in this owner manual. This warranty does not cover damage due to improper installation or use such as : inappropriate power of the unit for the size of the pool, improper use or maintenance according to the owner manual or provincial or national, state or municipal codes, installation by a person not authorized by Nirvana Heat Pump, flood, tornado, earthquake and other events known as an act of god, improper winterizing of the unit, frozen pipes, poor water quality or infiltration of abrasive substances or sand in the components of the unit, premature corrosion of the titanium coil resulting from improper use of chemicals (chlorine or salt level above or below standards), modification alteration, repair or replacement of parts made without the authorization of the manufacturer. Nirvana Heat Pump Inc. Agrees to repair or replace at its own discretion any parts deemed defective by an authorized dealer or technician. Heat pumps are not household appliances and should be repaired by a recognized technician. Evidence of servicing or repair by an unauthorized person will result in a cancellation of the manufacturer s limited warranty. The manufacturer will not be liable for direct or indirect damage caused by improper use or installation or for the inability to use the heat pump. The manufacturer does not offer any other warranty of any kind. No distributor or dealer is authorized to modify the terms and conditions of this warranty. Coverage under any additional warranty provided by a distributor or dealer is the sole responsibility of the dealer or distributor The warranty applies to the original purchaser and is transferable to successors only if the heat pump remains at the owner s original address and was installed according to standards and recommendations of this owner s manual, and until the expiry of the warranty. There is a $100 fee to transfer the warranty. Please contact 1-866-443-4476 to get the details. 14