R0A (kw-0kw) 0Hz KJR-0B/BE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the main board through the wired controller and the running condition can be displayed by the wired controller. ON/OFF TIME ON TEMP.SET TIME OFF OK PAGEUP/TEMP+ MANUAL/AUTO PAGEDOWN/TEMP- QUERY 0 ADDRESS- HEAT ADDRESS+ LOCK RESET ADDRESS SET 0 Mode Run Fault Turn-On Mode Time On Time Off Auto Manu TB Tot. Out On Online units Qty. Tot. load Query Heat Net-On 0 Item Description Item Description Heating mode. The unit has error, the light is on. AUTO running mode. When querying, the light is on. Dehumidification mode. When start up the auxiliary electric heater, the light is on. MANUAL running mode. When start up the net-on, the light is on. Pump mode. Current unit Amp. The running current of compressor in system A Actual output capacity. The outdoor ambient temp. T 0 Total load. The piping temp. TA of condenser in system A Inspected the units quantity on line. The piping temp. TB of condenser in system B The icon of unit quantity on line. 0 Setting water temp. Ts The total outlet water temp of plate heat exchanger. The running current of compressor in system B Display time of timing on or off. Display query data. Cooling mode. Normal running, the light is on.
R0A (kw-0kw) 0Hz R0A (kw-0kw) 0Hz KJR-0A/MBE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the main board through the wired controller and the running condition can be displayed by the wired controller. KJR-0A/MBE is a new generation wired controller used in the 0kW with low temp. cooling and kw digital scroll module with the new function of temperature difference setting, checking points and remote control function displaying etc. The wired controller KJR-0A/MBE is functional design to effectively promote controlability to meet customer s requirements.the new wired controller KJR-0A/MBE will replace the KJR-0B/BE, the KJR-0B/BE will not apply for the new module. The wired controller added new function as follow: The capacity adjusting action of regress differential temperature is adjustable. The adjustable range is,,, C ( C is default). Real time clock control. Malfunction manual reset. Point check parameter. Remote control remind function. Network control system SYSTEM INTRODUCTION This system is mainly composed by Epistatic Unit (network control system of epistatic unit), KJR-0B wired controller as well as sub-module. Each Epistatic Unit connects with a bus via serial port; mostly set of KJR-0B wired controller could be connected with a bus, while each wired controller could be under connected with mostly sets of Heat Pump Air Chilling module (i.e. mostly sets of Heat Pump Air Chilling module could be connected in this system). The address 0 is the main unit, other address are auxiliary units. Hardware composing Computer, RS- converter, KJR-0B/BE,KJR-0A/MBE wired controller, Module unit group. ON/OFF RS/RS converter Computer TIME ON TEMP.SET X,Y,E TIME OFF OK PAGE UP KJR-0E KJR-0E KJR-0E ALARM CLEAR PAGE DOWN QUERY CLOCK 0 ADDRESS/- ADDRESS/+ P,Q,E LOCK ADDRESS SET HYSTERESIS PCB PCB PCB On Off Units Qty. Run! Error Time On Time Off Query Antifreeze 0 PCBs PCBs PCB Net-On Item Description Item Description The unit quantity on line. AUTO running mode. Cooling mode. Heating mode. Pump mode. No used. Normal running, the light is on. 0 The unit has error, the light is on. When querying, the light is on. Anti-freeze protection. Remote control is on or off. Display time of timing on or off. Display query data. Main Function: Control operation mode in the refrigeration system. Query real-time operating parameter in the main system and subsystem. Set up the weekly timing that could realizes the schedule management for the refrigeration system. Record refrigeration system error.
R0A (kw-0kw) 0Hz R0A (kw-00kw) 0Hz 0 Protection All the protection and alarm information will be showed on the LED display on the main board. The Chiller Controller continuously performs important self-diagnostic checks while monitoring system temperatures, pressures and protection devices. It wills automatically shut down a compressor, a refrigerant circuit or the entire unit if a fault occurs. Use the check button and LED display can check the system operating status. When under protection or error,the LED will display protection code or error code. Check button LED display E0 Water flow detection error (The third time) P0 High pressure or air discharge temperature protection error in system A E E Power phase sequence error Communication error 0 P P Low pressure protection system A High pressure or air discharge temperature protection in system B Compressor current protection E Total water outlet temperature sensor error P Low pressure protection System B E Outlet water temperature sensor in Shell and tube exchanger error P Current protection in system A E Pipe temperature sensor in condenser A error P Current protection in system B E Pipe temperature sensor in condenser B error P Condenser high pressure protection in system A E Outdoor ambient temperature sensor error P Condenser high pressure protection in system B 0 E E System A is air discharge temperature sensor in digital compressor error Water flow detection error (The first and second times) P P System A is air discharge temperature sensor in digital compressor Protection of outlet and inlet water temperature difference Phase protection EA Main unit detect that auxiliary unit s quantity have decreased PA Starting protection of low-temp cooling EB EC Freeze-proof temperature sensor in shell and tube exchanger error Wire control did not found out any on-line module unit 0 Pb PC System freeze-proof protection ADDITIONAL SAFETY PROTECTION ED Ed EE EF Wire control and module unit communication error -hour consecutive -times PE protection Wire control and computer communication error Inlet water temperature sensor error PE F F Low-temperature protection of shell-and-tube heat exchanger EEPROM failure Failure of reduction of wired controller number at parallel connection of multiple wired controller (reserved)parallel connection of multiple wired controller Only for MGCSL-F(D)0W/RN,MGB-DW/RN, MGBT-F0W/RN E0 E E Error of outdoor EEPROM Power phase sequence error Communication error P0 P P High pressure or air discharge temperature protection error in system A (manual recovery) Low pressure protection System A (manual recovery) High pressure or air discharge temperature protection in system B (manual recovery) Midea modular air cooled chillers are equipped with intelligently designed safety control to ensure continuous safe operation. High and low pressure switch is provided to prevent the compressor damage resulting from either abnormally high discharge head pressure or low pressure. Differential pressure and paddle type flow switches are also provided with the units. The wired controller provides accurate water temperature control in the circuit by closely monitoring and reacting to the input from the water entering temperature, water leaving temperature and ambient air temperature. During normal condition, if the outlet water temperature falls below setting temperature (antifreeze temperature) the unit will be cut off automatically. Flow switch and Power contactor with thermal relays for compressor, fan motor and water pump are providing secondary protection for the unit. Each module is equipped with overload condenser fan motor protection and pump interlock input. E Error of total outlet water.temp sensor(be valid for main unit) P Low pressure protection System B (manual recovery) E Error of unit outlet water.temp sensor 0 P Current protection in system A (manual recovery) E Pipe temperature sensor in condenser A error P Current protection in system B (manual recovery) E Pipe temperature sensor in condenser B error P Condenser high temperature protection in system A E Outdoor ambient temperature sensor error P Condenser high temperature protection in system B E Output of the power protector error P 0 E Water flow detection error(manual recovery) P Protection of outlet and inlet water temperature difference EA PA Low ambient temperature drive-up protection Eb Freeze-proof temperature sensor in shell and tube exchanger error Pb System anti-frozen protection EC Ed Wire control detect that the units on-line have decreased. PC Pd Anti-freezing pressure protection of the system A (manual recovery) Anti-freezing pressure protection of the system B (manual recovery) Low pressure switch High pressure switch Three phase power protector EF Error of inlet water temperature sensor 0 PE Low-temperature protection of evaporator (manual recovery)
R0A (kw-0kw) 0Hz R0A (kw-0kw) 0Hz Typical piping 00kW module water pipeline sketch drawing /0kW module water pipeline sketch drawing Automatic Watering To Drain ExpansionTank Automatic Watering To Drain ExpansionTank Collector AUX.electric heater Collector Distributer AUX.electric heater Distributer The table below describes the symbols. The table below describes the symbols. Explanation explanation Explanation explanation Stop Valve Y-Shaped Filter Stop Valve Y-Shaped Filter Pressure Gauge Thermometer Pressure Gauge Thermometer Water Flow Switch Water Pump Water Flow Switch Water Pump -Way Valve Check Valve -Way Valve Check Valve Soft Joint Air Vent Soft Joint Air Vent
R0A (kw-0kw) 0Hz R0A (kw-0kw) 0Hz Electric characteristics Accessories Item Name of accessory Type Qty Shape Usage Outdoor Unit Power Supply Compressor OFM Model Hz Voltage Min. Max. TOCA MFA LRA RLA kw FLA MGB-FW/RN 0 0-. ( ).( ) 0.. MGB-DW/RN 0 0-. ( ).( ) 0.. MGB-F0W/RN 0 0-. ( ).( ) 0.. MGB-D0W/RN 0 0-. ( ).( ) 0.. MGCSL-F0W/RN 0 0-. ( ).( ) 0. MGCSL-D0W/RN 0 0-. ( ).( ) 0. MGB-FW/RN 0 0-00 0. 00 0( ). ( ) 0.( ).0( ) MGB-F0W/RN 0 0-00 0. 00 0( ).( ) 0.( ).0( ) MGB-FW/RN 0 0-00 0. 00 0( ). ( ) 0.( ).0( ) MGB-DW/RN 0 0-0 //.././. 0.( ).( ) MGB-F0W/RN 0 0-00 0 0 00 0( ). ( ) 0.( ).0( ) MGB-F00W/RN 0 0-00 0 0 00 0( ). ( ) 0.( ).0( ) MGBT-F0W/RN 0 0-00 0 0 ( ) 0.( ).( ).( ) Remark: TOCA: Total Over-current Amps. (A) MFA: Max. Fuse Amps. (A) LRA: Locked Rotor Amps. (A) RLA: Rated Locked Amps. (A) OFM: Outdoor Fan Motor. FLA: Full Load Amps. (A) kw: Rated Motor Input (kw) Installation and owner's --- manual The total outlet water LSQWRFM/A-C.ZL.0 temperature test kit KJR -0B/BE KJR -0A/MBE Water flow switch WFS-00-H Installation and using instruction. Inspection the temperature of total outlet water. Control the system. Control the system. (only for MGCSL-F(D)0W/RN, MGB-DW/RN, MGBT-F0W/RN) Anti-freezing protection (Only for 00kW) Function option ITEMS Cooling mode Heating mode Cooling in low ambient temperature(-0 C) PC based network software control BMS gateway(lonworks) BMS gateway(modbus) Alarm signal output Remote control(start/stop/mode setting) Set the water delta T Manual reset the alarm Inquire the outlet water temperature and anti-freeze temperature Clock display on the wire controller/stop setting according to the timer STANDARD OPTION Any of the option function should be confirmed by the factory before place the order. It is helpful for the factory to do necessary change in the product.