Air Cooled Chillers & Heat Pumps WinPACK HE-A

Similar documents
Air Cooled Chillers & Heat Pumps FullPower HE-A

Package Hygienic Air Handling Units. PHK Series

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

PRODUCT GUIDE

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

HYDRONIC RESIDENTIAL

Motor-driven condensing units MTE MTE R-410A

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

PYXIS U PYXIS U. rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

TCHVZ TCEVZ

CHAPTER 6 CONDENSING UNITS

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

LZT High efficiency air to water heat pumps with E.V.I. compressors

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

LZA High efficiency air to water heat pumps with HP compressor

Galletti Water chillers and heat pumps catalogue

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

WZH Ground source heat pumps

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Modular Air-cooled Chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Aquaflair TRAC-TRAF-TRAH

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

High temperature air-to-water heat pumps

pyxis u pyxis ua NEW rcgroupairconditioning


BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

pyxis pyxisa NEW rcgroupairconditioning

1

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

nemo a hp rcgroupairconditioning R410A

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

HIWARM COMPACT kw

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

Roof top SPACE RPC 450Z R407C M011

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning


i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Roof top SPACE RPC 315Z R407C MA00

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Blue Box Epsilon Echos +

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Ultimate energy saving technology

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

Transcription:

Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1

Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class A chillers and heat pumps Standard electronic expansion valve Multipurpose for systems with 2 pipes + DHW (with optional RC100) Integrated MASTER/SLAVE control TCAEQY 2150 with Tank&Pump THAETY 4270 with coil protection nets accessory Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant. Construction features Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater. 2, 3 or 4 capacity steps with high efficiency at partial loads. Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. Air side heat exchanger: featuring micro-channels or finned coil with copper pipes and aluminium fins depending on models/sizes. Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles. Control: microprocessor electronic control with Adaptive Function Plus logic. Structure: load bearing structure made of galvanised and painted steel plate coated with polyester powders. The unit is also complete with: - compressor and fan circuit breaker switches; - display of cooling circuit high and low pressure; - electronic expansion valve; - Master/Slave control up to 4 units in parallel; - clock board. Versions T - High efficiency version with oversized condensing section (TCAETY- THAETY). Q - Super-silenced version complete with soundproofing compressor technical compartment, super-reduced speed fans and oversized condensing section (TCAEQY-THAEQY). Models TCAETY: high efficiency unit designed for cooling only. TCAEQY: super silenced unit designed for cooling only. THAETY: heat pump unit. THAEQY: super silenced heat pump unit. Factory fitted accessories Shell and tube evaporator. PUMP with single or double electric pump, including an automatic pump in standby. The pumps are available in the low or high head versions. TANK&PUMP with integrated buffer tank from 300 to 700 litres (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge. VPF control. Desuperheater. 100% heat recovery unit -10 C condensing control. -15 C condensing control with fans with EC motor (standard with Q versions). Condensing control with over-pressure fans. Power factor correction capacitors (cosφ > 0.94). Forced limit of power consumption. Forced noise limit. Energy parameter measuring device. Optimised energy efficiency. Soft starter. Soundproofed compressor box or technical compartment soundproofing. Compressor soundproof enclosures. Cooling circuit delivery and intake valves. Refrigerant leak detector. Cooling circuit high and low pressure gauges. Double safety valves. Metal filters or Coil protection grilles. Micro-channel coils with E-coating treatment. Copper/copper or copper/pre-painted aluminium coils. Control of min/max power supply voltage. Digital input for double set-point. 4-20 ma analogue signal for shifting set-point. Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery if applicable. Buffer tank integrative heaters Low temperature water production. Interfaces for serial communication with other devices. Anti-vibration mounts. Separately supplied accessories Remote keypad with display. Thermostat with display. Untes supervisors for unit monitoring and remote management. Untes sequencer for integrated management of multiple chillers. 1

WinPACK HE-A // TCAEY-THAEY 2110-4340 TCAETY-TCAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340 ❶ Nominal cooling capacity kw 110,5 121,5 138,4 156,4 175,4 200,3 223,2 241,3 276,3 309,1 345,1 ❶ Nominal cooling capacity kw 100,6 108,6 126,5 140,5 155,5 181,4 199,4 218,4 251,4 280,2 318,2 ❶ E.E.R. 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 ❶ E.E.R. 2,73 2,60 2,69 2,65 2,60 2,64 2,61 2,56 2,68 2,62 2,63 ❶ Absorbed power kw 35,3 39,2 44,2 50,3 56,6 64,4 72,0 77,8 88,8 99,7 111,3 ❶ Absorbed power kw 36,8 41,8 47,0 53,0 59,8 68,7 76,4 85,0 93,8 106,9 121,0 THAETY-THAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340 ❷ Nominal heating capacity kw 114,5 124,5 141,6 161,6 181,7 204,8 233,9 249,8 282,8 321,0 357,0 ❷ Nominal heating capacity kw 110,5 118,5 136,5 153,6 171,6 194,7 221,8 236,7 266,7 301,0 341,9 ❷ C.O.P. 3,22 3,22 3,21 3,22 3,23 3,22 3,21 3,20 3,20 3,20 3,20 ❷ C.O.P. 3,28 3,29 3,27 3,26 3,26 3,23 3,26 3,12 3,11 2,95 3,08 ❶ Nominal cooling capacity kw 101,6 112,6 126,5 145,4 161,4 186,3 209,3 231,3 263,3 301,1 334,1 ❶ Nominal cooling capacity kw 91,6 100,6 118,6 130,6 144,5 169,5 187,4 206,5 238,4 270,3 302,3 ❷ Absorbed power kw 35,6 38,7 44,1 50,2 56,3 63,6 72,9 78,1 88,4 100,3 111,6 ❷ Absorbed power kw 33,7 36,0 41,7 47,1 52,6 60,3 68,0 75,9 85,8 102,0 111,0 TCAETY-TCAEQY-THAETY-THAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340 ❸ TCAETY sound pressure db(a) 55 56 57 57 58 59 59 58 60 60 62 ❸ THAETY sound pressure db(a) 53 54 55 55 56 57 57 58 60 60 62 ❸ TCAEQY-THAEQY sound pressure db(a) 47 47 48 48 49 50 50 51 53 53 54 ❹ TCAETY sound power db(a) 87 88 89 89 90 91 91 90 92 92 94 ❹ THAETY sound power db(a) 85 86 87 87 88 89 89 90 92 92 94 ❹ TCAEQY-THAEQY sound power db(a) 79 79 80 80 81 82 82 83 85 85 86 Scroll/step compressor no. 2/3 2/3 2/2 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4 Circuits no. 1 1 1 1 1 1 1 2 2 2 2 Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 DIMENSIONS AND WEIGHTS 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340 L - Width mm 3.600 3.600 3.600 3.600 4.550 4.550 4.550 4.800 4.800 5.300 5.300 H - Height mm 2.440 2.440 2.440 2440 2.440 2.440 2.440 2.030 2.030 2.030 2.030 P - Depth mm 1.350 1.350 1.350 1.350 1.350 1.350 1.350 2.090 2.090 2.090 2.090 ❺ TCAETY weight kg 1.090 1.100 1.110 1.130 1.280 1.300 1.320 2.290 2.390 2.520 2.640 ❺ TCAEQY weight kg 1.250 1.260 1.270 1.290 1.440 1.460 1.480 2.420 2.520 2.650 2.770 ❺ THAETY weight kg 1.380 1.410 1.420 1.500 1.670 1.690 1.780 2.470 2.570 2.720 2.840 ❺ THAEQY weight kg 1.420 1.450 1.460 1.540 1.710 1.730 1.820 2.600 2.700 2.850 2.970 Data at the following conditions: ❶ Air: 35 C - Water: 12/7 C. ❷ Air: 7 C, D.B. 6 C W.B.- Water: 40/45 C. ❸ In open field (Q = 2) at 10 m from the unit. ❹ Total sound power level in db(a) based on measurements carried out in accordance with regulation UNI EN-ISO 9614. ❺ Weight referred to the unit without load and not accessorised. TCAEQY-THAEQY super-silenced versions. Performance according to EN 14511:2013. 2

WinPACK HE-A // TCAEY-THAEY 2110-4340 SEASONAL ENERGY PERFORMANCE 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340 TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE 1 Pdesignc (EN 14825) kw 110,5 121,5 138,4 156,3 175,3 200,2 223,1 241,3 276,2 309,1 345,0 1 SEER (EN 14825) 4,21 4,26 4,10 4,22 4,27 4,21 4,24 4,29 4,30 4,29 4,30 2 η s,c % 165 167 161 166 168 165 167 169 169 168 169 TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE 1 Pdesignc (EN 14825) kw 100,6 108,6 126,5 140,5 155,4 181,3 199,3 218,4 251,4 280,2 318,2 1 SEER (EN 14825) 4,13 3,99 4,01 4,07 3,95 4,08 4,00 4,09 4,17 4,17 4,13 2 η s,c % 162 157 157 160 155 160 157 160 164 164 162 THAETY MODEL SEASONAL PERFORMANCE IN HEATING MODE 3 Pdesignh (EN 14825) kw 96 104 118 135 150 173 201 211 242 273 302 3 SCOP (EN 14825) 3,53 3,51 3,75 3,49 3,76 3,39 3,57 3,64 3,62 3,64 3,63 4 η s % 138 138 147 137 148 133 140 142 142 143 142 THAEQY MODEL SEASONAL PERFORMANCE IN HEATING MODE 3 Pdesignh (EN 14825) kw 91 98 113 127 141 165 190 199 227 254 288 3 SCOP (EN 14825) 3,62 3,61 3,84 3,59 3,87 3,53 3,65 3,56 3,54 3,37 3,52 4 η s % 142 141 151 141 152 138 143 139 139 132 138 1 Low temperature application (7 C) 2 Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281) 3 In Average climatic conditions, low temperature application (35 C) 4 Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/213 and No.813/2013) 3

Export Sales Office Address: 53. Cadde 1450. Sokak Ulusoy Plaza No: 9/50 Cukurambar, Ankara, Turkey Email: export@untes.com.tr T+90 (312) 287 91 00 F+90 (312) 284 91 00 Manufacturing Plant-1 Air Handling & Ventilations Systems, Fan Coil Systems Packaged Air Conditioning Systems Address: Istanbul Yolu 37.km Kahramankazan, Ankara, Turkey Manufacturing Plant-2 Water Chiller and Heat Pumps Address: Istanbul Yolu 24.km Saraykoy, Ankara www.untes.com untesklima Untes Heating Air Conditioner Inc. reserves the right to make changes in the products, technical data, figures, designs and materials of the products in the catalog without any notice or information. All contents are copyrighted by Untes. 4