Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Similar documents
Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

The Advance You ve Been Looking For

Fire Safety Product Catalog

Fire & Life Safety Products CATALOG

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

Reshaping Duct Smoke Detection

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

Reshaping Duct Smoke Detection

Full Line Catalog and Product Brochures

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Selectable Output Chimes and Chime/Strobes

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Control / Communicator

Lite-Configurator Version 3.1 Readme

L-Series, Indoor Strobes and Horn Strobes

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

L-Series, Indoor Strobes and Horn Strobes

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev.

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Agent Release Control Panel

L-Series, Emergency Communication Devices

Addressable Detectors & Bases

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

SECTION FIRE ALARM SYSTEMS

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

TrueAlarm Analog Sensing

ELECTRONIC SOUNDER STROBE Model : AVD-C407

WFDE Series Waterflow Detector

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

DH100ACDCI Ionization Air Duct Smoke Detector

TrueAlarm Analog Sensing

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

Vista-20SEUL System Design Sheet

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AL600ULX Series. Power Supply/Charger. Installation Guide

Vista-50P/-50PUL System Design Sheet

TrueAlert Addressable Notification Appliances

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

good things in small packages

DH100ACDCI Ionization Air Duct Smoke Detector

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TrueAlert Notification Appliances

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

TrueAlarm ES Analog Sensing

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Potter Wall Mount Select-A-Strobe

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Multi-Point Peripherals

Vista-128FB System Design Sheet

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Life safety notification

Signature Series Auto-Sync Output Module (CC1S)

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Conventional Fire Detection

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Addressable Fire Alarm Control Panel

Xenex Conventional Fire Detection & Alarm System

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Multiple Input and Output Modules

July 14, 1999 DF C-100.

Silent Knight Device Compatibility

SAFEPATH Mass Notification System (SPMNS)

Fire Alarm System Fundamentals

Multi-Point Peripherals

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Commercial and Light Industrial Fire Alarm Control Panel

AND ARCHITECT SPECIFICATIONS

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Vista-10SE System Design Sheet

SAFEPATH SAFEPATH. Emergency communications system

TECHNICAL DATA OBSOLETE

s Notification Appliances

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Specification/ Data Sheet

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

LifeAlarm Fire Alarm Controls

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Detection and Control Components

TrueAlert Addressable Notification Appliances

Analog fire panels FPA-1000 Family

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

SP40S-D. Kingfisher Company, inc. Features: Description:

INSTALLATION AND MAINTENANCE

D7024 Fire Alarm Control Panel

Hazardous Location Supervised Warning Light

SELECT-A-HORN/STROBE SERIES

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

June 10, 2002 DF C S2424

DH500ACDC Intelligent Air Duct Smoke Detector Housing

Transcription:

F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with the highest level of reliability. In other words, we make it our business to develop advanced ideas that deliver advanced solutions. This product guide is divided into four areas: Conventional Detection a complete line of smoke detectors led by the innovative i 3 Series. Audible/Visible Notification the SpectrAlert Advance line, the industry s newest, most refined series of notification devices. HVAC Systems Monitoring the Innovair line and other specialty detectors designed to detect smoke in air duct networks. Sprinkler Systems Monitoring products designed to sense the flow of water through pipes, switches and valves. Conventional Detection i 3 Series Photoelectric Smoke Detectors Installation ease, intelligence and instant inspection are the guiding principles of the System Sensor i 3 Series photoelectric smoke detectors. The i 3 Series is a complete line standard, sounder, auxiliary Form C relay and isolated thermal models featuring plug-in bases, removable covers, remote maintenance signaling, drift compensation and smoothing algorithms, green and red LEDs, and simplified sensitivity measurement. Loop Type Thermal Sounder Form C Relay Operating Voltage Avg. Standby Current Max. Alarm Current 2W-B 2-wire No No No 8.5 35 VDC 50 µa 130 ma limited by control panel 2WT-B 2-wire Yes No No 8.5 35 VDC 50 µa 130 ma limited by control panel 4W-B 4-wire No No No 8.5 35 VDC 50 µa 23 ma 4WT-B 4-wire Yes No No 8.5 35 VDC 50 µa 23 ma 2WTA-B 2-wire Yes Yes No 8.5 35 VDC 50 µa 130 ma* 2WTR-B 2-wire Yes No Yes 8.5 35 VDC 50 µa 130 ma limited by control panel 4WTA-B 4-wire Yes Yes No 10 35 VDC 50 µa 35 ma 4WTR-B 4-wire Yes No Yes 10 35 VDC 50 µa 35 ma 4WTAR-B 4-wire Yes Yes Yes 10 35 VDC 50 µa 50 ma 4WITAR-B 4-wire Isolated Yes Yes 10 35 VDC 50 µa 50 ma * In direct power (non-reverse polarity), the maximum alarm current is 130 ma limited by the panel. In reverse polarity power, the maximum current is 30 ma for the 2WTA-B in alarm; 12 ma for all other 2WTA-B units on the loop. Add 25 ma for the RRS-MOD reversing relay alarm current. 100 Series Plug-in Smoke Detectors The 100 Series low profile plug-in smoke detectors are ideal for light commercial applications. Offered with a photoelectric sensor, the 100 Series units may be installed with a range of plug-in bases to accommodate a variety of wiring configurations and voltages. Detection Type Wiring Thermal Operating Voltage Avg. Standby Current Max. Alarm Current 2151 Photoelectric Mounting base dependent No See bases 85 µa Mounting base dependent 2151T Photoelectric Mounting base dependent Yes See bases 85 µa Mounting base dependent 1

400 Series Plug-in Electronic Heat Detectors The 400 Series plug-in electronic heat detector offers thermal detection in a 135 F combination fixed/ rate-of-rise configuration. The 5451 detector may be installed with a range of 400 Series plug-in bases. Temperature Rating Activation Method Max. Standby Current 5451 135 degrees F Fixed/Rate-of-rise 100 µa 100 Series Plug-in Smoke Detector Bases The 100 Series bases are designed for use with the System Sensor 100 Series plug-in smoke detectors and accommodate 2- or 4-wire loops and 12, 24 or 120 operating voltages to address a broad range of applications. Loop Type Operating Voltage Alarm Current B110LP 2-wire 12/24 VDC 10-100 ma limited by the control panel B110RLP 2-wire 24 VDC 22 62 ma B112LP 4-wire 24 VDC 14 39 ma B114LP 4-wire 120 VAC 75 ma (AC) maximum B116LP 2-wire 24 VDC 12 100 ma limited by the control panel 400 Series Plug-in Smoke Detector Bases The 400 Series bases are designed for use with System Sensor 400 Series and 100 Series plug-in smoke detectors and are offered in a variety of models for 2- or 4-wire loops and 12, 24 or 120 operating voltages. Loop Type Alarm Contact Type Operating Voltage Max. Alarm Current B401 2-wire 12/24 VDC 10 100 ma limited by the control panel B401B 2-wire 12/24 VDC 10 100 ma limited by the control panel B401BR 2-wire 24 VDC 10 62 ma B402B 4-wire Form A & C 24 VDC 14 39 ma B404B 4-wire Form A & C + A supervisory 120 VAC 75 ma (AC) maximum B406B 2-wire Form C 24 VDC 12 100 ma limited by the control panel CO1224T Carbon Monoxide Detector The CO1224T detector with RealTest is the industry s first carbon monoxide detector specifically designed for system connection. It is designed to maximize profits and minimize installation costs with code compliant features such as a trouble relay that sends a sensor failure or end-of-life signal to the control panel, and SEMS type terminal Philips-head screws that provide a quick and positive wiring connection while facilitating wiring supervision. The CO1224T unit also features a low current draw, which allows more detectors to be connected to the panel without having to purchase a more expensive panel or extra power supply. 2 Detection Type Wiring Operating Voltage Max. Standby Current CO1224T Electrochemical 4-wire 12/24 VDC 20mA 40mA Max. Alarm Current

5600 Series Mechanical Heat Detectors The 5600 Series mechanical heat detectors offer a low-cost means to protect property against fire and for non-life-safety installations where smoke detectors are inappropriate. To accommodate a broad range of applications, the 5600 Series units are available in a full line of configurations. Singleand dual-circuit models are available with low or high temperature ratings and with fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. Circuit Identification Method on Exterior Temperature Rating Activation Method Reflected Beam Smoke Detector The BEAM1224 Series reflected beam smoke detectors are equipped with both a transmitter and a receiver in one unit. They are easy to install and align with the included reflector. The BEAM1224S model comes with an integral sensitivity test feature. With six sensitivity levels, the BEAM1224 unit can be set to respond accurately in its respective environment. Plus, with multiple accessories ranging from multi-mounting to device heating, the BEAM1224 detector is capable of protecting any high ceiling area. Wiring Operating Voltage Avg. Standby Current Avg. Alarm Current Range Protected Spacing** 5601P Single Non-lettered 135 F (57 C) Fixed/Rate-of-rise 50 feet by 50 feet 5602 Single Lettering 194 F (90 C) Fixed/Rate-of-rise 50 feet by 50 feet 5603 Single Lettering 135 F (57 C) Fixed temperature 25 feet by 25 feet 5604 Single Lettering 194 F (90 C) Fixed temperature 25 feet by 25 feet 5621 Dual Lettering 135 F (57 C) Fixed/Rate-of-rise 50 feet by 50 feet 5622 Dual Lettering 194 F (90 C) Fixed/Rate-of-rise 50 feet by 50 feet 5623 Dual Lettering 135 F (57 C) Fixed temperature 25 feet by 25 feet 5624 Dual Lettering 194 F (90 C) Fixed temperature 25 feet by 25 feet **Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. BEAM1224 4-wire 10.2 32 VDC 17 ma max. @ 24 VDC 38.5 ma max. @ 24 VDC 16 328 ft. (5m to 100m) BEAM1224S 4-wire 15 32 VDC 17 ma max. @ 24 VDC 38.5 ma max. @ 24 VDC 16 328 ft. (5m to 100m) Multi-Voltage Conventional Relays The System Sensor multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of building system interfacing. Description Operating Voltage Operating Current Contact Ratings PR-1 PR-2 PR-3 R-10T R-14T R-20T R-24T R-10E R-14E R-20E R-24E Epoxy encapsulated (SPDT) relay with an activation LED Epoxy encapsulated (SPDT) relay with an activation LED Epoxy encapsulated (SPDT) relay with an activation LED Single (SPDT) relay with an activation LED 4-gang (SPDT) relay with 4 activation LEDs Single (DPDT) relay with an activation LED 4-gang (DPDT) relay with 4 activation LEDs Single (SPDT) relay with an activation LED and steel enclosure 4-gang (SPDT) relay with 4 activation LEDs and steel enclosure Single (DPDT) relay with an activation LED and steel enclosure 4-gang (DPDT) relay with 4 activation LEDs and steel enclosure 120 VAC 15 ma DC max. @ 24 VDC, 24 VAC, 120 VAC 24 VDC: 7 A with L/R = 5 ms; 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive; 30 VDC: 10 A resistive 10 40 VDC 30 ma DC max. 120 VAC: 10 A max. (resistive load); 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load); 30 VDC: 10 A max. (resistive load) 10 40 VDC 30 ma DC max. 120 VAC: 10 A max. (resistive load); 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load); 30 VDC: 10 A max. (resistive load) 20 ma DC max. @ 24 VDC, 20 ma DC max. @ 24 VDC, 40 ma DC max. @ 24 VDC, 40 ma DC max. @ 24 VDC, 20 ma DC max. @ 24 VDC, 20 ma DC max. @ 24 VDC, 40 ma DC max. @ 24 VDC, 40 ma DC max. @ 24 VDC, 3

Conventional Detection Accessories Complementing the line of System Sensor detection products is a host of accessories designed to enhance installation, testing, operation, and maintenance. SENS-RDR RRS-MOD 2W-MOD2 RT A77-AB2 XR2B A77-AB RMK400 SMB600 MOD400R EOLR-1 APA151 BEAMLRK BEAMMMK BEAMSMK BEAMHK BEAMHKR RA400Z RTS451 RTS451KEY Description i 3 series infrared sensitivity reader i 3 series reversing relay / synchronization module i 3 series loop test and maintenance module i 3 series removal/replacement tool i 3 series retrofit adapter bracket 100 series installation/removal tool 100 series retrofit adapter bracket 100/400 series recessed mounting kit 100/400 series surface mount kit 100/400 series field sensitivity test module End of line power supervision relay Remote annunciator with piezo alarm Long-range kit for BEAM1224/BEAM1224S Multi-mount kit for BEAM1224/BEAM1224S Surface-mount kit for BEAM1224/BEAM1224S Heater kit for transmitter/receiver unit Heater kit for reflector Remote annunciator for spot and duct smoke detectors Remote test station accessory Remote test station accessory with key SENS-RDR MOD400R 2W-MOD2 APA151 RTS451KEY Audible/Visible Notification SpectrAlert Advance Wall-Mount Strobes The SpectrAlert Advance wall-mount strobe features a universal mounting plate with plug-in design, 11 field-selectable candela settings, and dual voltage in one device. The amber lens strobes provide the distinctive visual signal used for mass notification during non-fire evacuations. SpectrAlert Advance strobes are listed to UL 1971. SW-ALERT and SWH-ALERT amber lens strobes are listed to UL 1638. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SR SR-P* SR-SP* SRK SRK-R* SRK-P SRH SRH-P* SRHK SRHK-R* SRHK-P SW SW-P* SW-ALERT** SWK SWK-P SWH SWH-P* SWH-ALERT** SWHK SWHK-P Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. ** UL 1971 is not applicable to mass notification devices. Listed candela rating is per UL 1638 on-axis rating. 4

SpectrAlert Advance Wall-Mount Horn Strobes The SpectrAlert Advance wall-mount horn strobe is rich with features guaranteed to deliver cost-efficient installation time. Features include universal mounting plate with plug-in design, 11 field selectable candela settings, dual voltage in one product, and rotary switch selectable horn tone and volume settings. SpectrAlert Advance horn strobes are listed to UL 1971 and UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. P2R P2R-P* P2R-SP* P2RK P2RK-R* P2RK-P P2RH P2RHK P2RHK-R* P2RHK-P P2RHK-120 UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, Standard Range (15 115 cd) 8 17.5 V 16 33 V DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 P2W P2W-P* Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input P2WK Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, High Range (135 185 cd) 16 33 Volts 16 33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 P2WH Temporal High 245 259 290 297 Temporal High 215 231 258 265 P2WH-P* Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 P2WHK Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Description, outdoor, high-candela horn strobe with integral 120V adapter; includes outdoor backbox To calculate current draw for 4-wire horn strobes, add the required strobe current and horn current from the tables below: P4R P4RK P4RK-R* P4RH P4W P4WK P4WHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 5

SpectrAlert Advance Mini-Horns The SpectrAlert Advance series of mini-horn sounders are designed to provide primary and secondary signaling for fire and security applications. They include two volume settings, 12- or 24-volt operation and are compatible with the System Sensor synchronization protocol. MHR MHW Sound Pattern Volume Sounder Current Draw (ma RMS) DC FWR DC FWR Temporal High 12 10 17 15 Temporal Low 10 9 14 13 Non-temporal High 22 17 29 25 Non-temporal Low 17 13 21 19 SpectrAlert Advance Horns The SpectrAlert Advance horn includes a universal mounting plate with plug-in design, three volume settings, and a rotary switch used for horn tone selection. SpectrAlert Advance horns are listed to UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. HR HRK HKR-R* HW UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 * All outdoor units ending in K include weatherproof back box except those with a -R suffix SpectrAlert Advance Chimes The SpectrAlert Advance chimes feature rotary switch selectable horn tone and volume settings and are compatible with the System Sensor synchronization protocol. Intended for private mode applications, the chime meets UL 464. CHR CHW UL Max. Chime Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR 1 Second Chime High 34 50 58 51 1 Second Chime Low 30 51 51 54 ¼ Second Chime High 34 51 50 50 ¼ Second Chime Low 31 51 50 52 Temporal Chime High 30 50 48 54 Temporal Chime Low 30 47 50 51 5 Second Whoop High 32 52 34 54 5 Second Whoop Low 30 40 34 52 Coded High 48 49 50 50* *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. 6

SpectrAlert Advance Chime/Strobes The SpectrAlert Advance chime/strobes feature a plug-in design, seven field-selectable candela settings, and dual voltage in one device. Intended for private mode application, the chime/strobe meets UL 1638. CHSR CHSW UL Max. Chime/Strobe Current Draw (ma RMS) DC Input 15 15/75 15 15/75 30 75 95 110 115 1 Second Chime High 131 142 65 76 94 160 185 207 213 1 Second Chime Low 131 142 64 75 92 157 183 203 212 1/4 Second Chime High 129 142 66 75 95 159 184 205 212 1/4 Second Chime Low 129 142 64 74 91 155 181 204 211 Temporal Chime High 125 142 64 74 91 156 181 205 211 Temporal Chime Low 129 141 65 75 92 155 180 200 209 5 Second Whoop High 133 145 70 81 99 165 189 210 217 5 Second Whoop Low 130 143 66 77 95 160 186 206 214 One Time Chime* 127 141 64 76 93 156 182 203 210 FWR Input 15 15/75 15 15/75 30 75 95 110 115 1 Second Chime High 128 150 72 82 98 158 183 202 210 1 Second Chime Low 127 150 71 81 97 157 182 202 210 1/4 Second Chime High 129 149 72 82 99 160 183 203 211 1/4 Second Chime Low 128 149 71 81 97 154 179 196 205 Temporal Chime High 128 148 71 81 97 157 179 199 206 Temporal Chime Low 125 147 71 81 97 156 180 200 206 5 Second Whoop High 136 152 84 93 110 170 193 212 220 5 Second Whoop Low 132 150 77 86 102 161 184 203 214 One Time Chime* 127 147 72 82 97 157 181 200 210 *Chime/strobes cannot be powered with a coded supply. SpectrAlert Advance Ceiling-Mount Strobes The SpectrAlert Advance ceiling-mount strobes feature a universal mounting plate with preliminary snap-in feature to hold the product in place for the screw attachment, 11 field-selectable candela settings, and dual voltage in one device. SpectrAlert Advance strobes are listed to UL 1971. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SCR SCRK SCRK-R* SCRH SCRHK SCRHK-R* SCW SCW-P* SCWK SCWH SCWHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 7

SpectrAlert Advance Ceiling-Mount Horn Strobes The SpectrAlert Advance ceiling-mount horn strobes are rich with features guaranteed to cut installation time and maximize profits. Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 11 fieldselectable candela settings, dual voltage in one product, and rotary switch selectable horn tone and volume settings. SpectrAlert Advance horn strobes are listed to UL 1971 and UL 464. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. PC2R PC2R-P* PC2RK PC2RK-R* PC2RH PC2RHK PC2RHK-R* PC2W PC2W-P* PC2W-SP* PC2WK PC2WH PC2WH-P* PC2WHK UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, Standard Range (15 115 cd) 8 17.5 V 16 33 V DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (ma RMS), 2-wire Horn Strobe, High Range (135 185 cd) 16 33 Volts 16 33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 To calculate current draw for 4-wire horn strobes, add the required strobe current and horn current from the tables below: PC4R PC4RH PC4W PC4WK PC4WHK Standard High UL Max. Strobe Current Draw (ma RMS) DC FWR DC FWR 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Horn Current Draw (ma RMS) Sound Pattern db DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print); -SP denotes FUEGO printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes. 8

SpectrAlert Advance Dual Voltage Evacuation Speakers The dual voltage (25/70.7 Vrms) evacuation speakers feature a plug-in design for reducing ground faults and allowing for fast installation. The low total harmonic distortion of the SP speaker offers high-fidelity sound output while the SPV speaker offers high-volume sound output for use in high-ambient-noise applications. The outdoor models ship with a plastic outdoor back box featuring removable side flanges and improved salt water corrosion resistance. Outdoor products are rated from 40 F to +151 F ( 40 C to +66 C) and have a NEMA 4X rating. SpectrAlert Advance speakers are listed to UL 1480 for fire protective signaling systems. SpectrAlert Advance Selectable Output Speaker Strobes The selectable output speaker strobes offer many features to reduce ground faults and make installation simple, including plug-in design with universal mounting plate, rotary switches for voltage and power settings, 11 field-selectable candela settings, and speakers for high fidelity or high volume. The outdoor models ship with the plastic outdoor back box and are rated from 40 F to +151 F ( 40 C to +66 C) for outdoor operation. SpectrAlert Advance selectable output speaker/ strobes are listed to UL 1971 and UL 1480. Model numbers with a K suffix are listed to UL 1638 and NEMA 4X for outdoor use. SPSR SPSR-P* SPSRV SPSRV-P* SPSCR SPSCRV SPSRK SPSRK-R SPSRK-P SPSRH SPSRH-P* SPSCRH SPSCRVH UL Max. Strobe Current Draw (ma RMS) SPSW SPSW-P* SPSWV SPSWV-P* SPSCW SPSCW-P* SPSCWV SPSCWV-P* SPSWK SPSWK-R SPSWK-P SPSCWK SPSCWK-R SPSWH SPSWH-P* SPSCWH SPSCWH-P* SPSCWVH SPSCWVH-P* SPSCWHK SPSCWHK-R * For all SpectrAlert Advance models, a -P suffix denotes plain housing (no FIRE print). 8 to 17.5 Volts DC 8 to 17.5 Volts FWR 16 to 33 Volts DC 16 to 33 Volts FWR 15 123 128 66 71 15/75 142 148 77 81 30 N/A N/A 94 96 75 N/A N/A 158 153 95 N/A N/A 181 176 110 N/A N/A 202 195 115 N/A N/A 210 205 135 N/A N/A 228 207 150 N/A N/A 246 220 177 N/A N/A 281 251 185 N/A N/A 286 258 SpectrAlert Advance Sync Circuit Module The SpectrAlert Advance Sync Circuit module is designed to simplify installations requiring signal synchronization. Average Current (ma) Peak Current (ma) In-rush Current (ma) Voltage DC FWR DC FWR DC FWR MDL MDLW Description SPR SPW Wall mount speaker SPRV SPWV Wall mount speaker, high db SPCR SPCW Ceiling mount speaker SPCRV SPCWV Ceiling mount speaker, high db SPRK, SPRK-R SPWK, SPWK-R Outdoor wall mount speaker SPCWK, SPCWK-R Outdoor ceiling mount speaker 12 10 12 30 31 87 122 24 11 15 35 37 198 262 9

SpectrAlert Advance Accessories SpectrAlert Advance devices can be adapted to nearly any application by selecting the appropriate accessory to meet the application need. Our mounting options allow our strobes, speakers, horns, chimes, and strobe combinations to be placed in new or existing construction with professional results. Description SPBBSC SPBBSCW Surface mount back box skirt for ceiling mount speaker strobe SPBBS SPBBSW Surface mount back box skirt for wall mount speaker strobe RFP RFPW Retrofit plate for SpectrAlert Advance devices BBS-2 BBSW-2 Surface mount back box skirt for wall mount horns, strobes, and horn strobes BBSC-2 BBSCW-2 Surface mount skirt for ceiling mount horns, strobes, and horn strobes SA-WBB Wall mount, metal outdoor back box for horns, strobes, and horn strobes SA-WBBC Ceiling mount, metal outdoor back box for horns, strobes, and horn strobes TR-HS TRW-HS Wall mount trim ring for SpectrAlert Advance horns, strobes, and horn strobes TRC-HS TRCW-HS Ceiling mount trim ring for SpectrAlert Advance horns, strobes, and horn strobes TR TRW Wall mount trim ring for SpectrAlert Advance speakers and speaker strobes TRC TRCW Ceiling mount trim ring for SpectrAlert Advance speakers and speaker strobes MWBB MWBBW Wall mount metal outdoor back box for speakers and speaker strobes MWBBCW Ceiling mount metal outdoor back box for speakers and speaker strobes MP120K Indoor/outdoor 120VAC adapter mounting plate for use with SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes Wall Ceiling Description LENS-A LENS-AC Amber lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-B LENS-BC Blue lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-G LENS-GC Green lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models LENS-R LENS-RC lens attachment for SpectrAlert Advance non-fire (plain) indoor or outdoor strobe models HVAC Systems Monitoring During a fire, an HVAC system can circulate toxic gasses and smoke throughout a building unless that building is equipped with InnovairFlex duct smoke detectors. Overcome Mounting Constraints InnovairFlex housings can accommodate multiple installation footprints, including rectangular, square, and anything in between. uce Installation Time Sampling tubes can be installed from the front or back of the detector without the need for tools or hardware. Additional conduit openings, improved wiring space, and high-contrast terminal designations simplify the installation process further. Simplify Testing and Maintenance On 4-wire models an easy access test/reset button simplifies system testing, and Power, Trouble, Maintenance, and Alarm LEDs assure quick and convenient status checks. The cover missing trouble signal, now included on all models, assures system integrity. 10 Model Description Wiring D2 D4120 D4120W D4S Photoelectric low-flow duct smoke detector Photoelectric low-flow duct smoke detector Watertight photoelectric lowflow duct smoke detector Photoelectric low-flow sensor only component Air Velocity Range Operating Temp. Range 2-wire 100 4000 ft/min 4 to 158 F ( 20 to 70 C) 4-wire 100 4000 ft/min 4 to 158 F ( 20 to 70 C) 4-wire 100 4000 ft/min 4 to 158 F ( 20 to 70 C) 4-wire 100 4000 ft/min 4 to 158 F ( 20 to 70 C) D4P120 Power board only component 4-wire 4 to 158 F ( 20 to 70 C) 2151 Photoelectric no-flow/low-flow smoke detector 4-wire 0 3000 ft/min 32 to 120 F (0 to 49 C) Rating Operating Voltage Alarm Current 12/24 VDC 130 ma max 24 VAC/DC or 120 VAC 65 ma max at 24 VDC NEMA 4 24 VAC/DC or 120 VAC 65 ma max at 24 VDC 24 VAC/DC or 120 VAC 65 ma max at 24 VDC 24 VAC/VDC or 120 VAC 65 ma max at 24 VDC 24 VAC/DC w/b114lpbt base; 120 VAC w/b114lp base Auxiliary Contact 2 Form C Auxiliary 2 Form C Auxiliary 2 Form C Auxiliary 75 ma max 1 Form A & 1 Form C Auxiliary Relay

HVAC Accessories Model Description Operating Voltage SSK451 Multi-signaling accessory, remote test station with horn, allows local testing of a remote duct detector, for use with System Sensor D4120, DH100ACDC and DH400ACDC 15 35 VDC APA151 Remote annunciator with piezo alert 16 33 VDC RA400Z Remote annunciator for spot and duct smoke detectors 3.1 32 VDC RTS451 Remote test station accessory 2.8 32 VDC (Alarm LED) RTS451KEY Remote test station accessory with key reset 14 35 VDC (Power LED); 2.8 32 VDC (Alarm LED) RTC100 Remote test coil kit with low-profile ring (includes RTS451 remote test station) PS24LO(W) Mini-Alert add-on strobe for use with SSK451 or PA400W 16 33 VDC DST1 DST1.5 DST3 DST5 DST10 ETX InnovairFlex sampling tube for ducts up to 1 foot InnovairFlex sampling tube for ducts 1 to 2 feet InnovairFlex sampling tube for ducts 2 to 4 feet InnovairFlex sampling tube for ducts 4 to 8 feet InnovairFlex sampling tube for ducts 8 to 12 feet InnovairFlex twelve-inch exhaust tube Sprinkler Systems Monitoring WFD Series Water Flow Detector The WFD Series water flow detectors are available in a range of sizes to accommodate fire sprinkler risers from two to eight inches. All units feature vane type paddles and an adjustable mechanical relay. Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD20 2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD25 2 1 /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD30-2 3 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD35 3 1 /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD40 4 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD50 5 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD60 6 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM WFD80 8 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4 10 GPM T-Tap Series Water Flow Detector The T-Tap water flow detectors are compatible with one-inch NPT style connections, making them ideal for residential or branch line signaling applications. Model WFDT WFDTH WFDTNR Compatible Tee Fittings 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. Pressure Rating Contact Ratings 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC Triggering Threshold 4 10 GPM 4 10 GPM 4 10 GPM 11

Supervisory Switches System Sensor manufactures devices for supervising a variety of control valves, including outside screw and yoke, post indicator, butterfly, and rising and non-rising stem gate. Model Description Valve Size Contact Rating OSY2 PIBV2 PSP1 Used to monitor the open position of an outside screw and yoke type gate valve Used to monitor the open position of post indicator and butterfly control valves A plug-in special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used 1 to 12 10 AMP @ 125/250 VAC; 2.5 AMP @ 6/12/24 VDC 10 AMP @ 125/250 VAC; 2.5 AMP @ 6/12/24 VDC Plug Contacts: 250mA @ 6/12/24 VAC/DC, normally open Cover Tamper: 5A @ 125/250 VAC, 2.5A @ 6/12/24 VAC Maximum Operating Current 250mA EPS Series Pressure Switches The EPS Series pressure switches are offered in three varieties and with one or two SPDT contacts. The EPS10 alarm pressure switches are ideal for dry pipe systems, while the EPS40 and EPS120 supervisory pressure switches are intended for supervising air pressure in pipes or pressure tanks. Model EPS10-1 EPS10-2 EPS40-1 EPS40-2 EPS120-1 EPS120-2 Maximum Operating Pressure Maximum Adjustment Range Differential Contact Rating 250 psi 4 to 20 psi 3 psi 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 250 psi 10 to 100 psi 3 psi @ 10 psi and 6 psi at 100 psi 250 psi 10 to 200 psi 3 psi @ 10 psi and 9 psi at 200 psi 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC Threaded Connection 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon Alarm Bells The alarm bells offer high output notification in security and fire alarm systems. Six-inch, eight-inch, and ten-inch models are available for 24 VDC and 120 VAC systems. Model Gong Size Nominal Voltage Operating Voltage Sound Output Maximum Current SSM24-6 6 24 VDC 16 33 VDC 82 db DC 31.1 ma / FWR 53.5 ma SSM24-8 8 24 VDC 16 33 VDC 80 db DC 31.1 ma / FWR 53.5 ma SSM24-10 10 24 VDC 16 33 VDC 81 db DC 31.1 ma / FWR 53.5 ma SSV120-6 6 120 VAC 96 132 VAC 85 db 53 ma SSV120-8 8 120 VAC 96 132 VAC 82 db 53 ma SSV120-10 10 120 VAC 96 132 VAC 82 db 53 ma 12

System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated, and designed for real-world applications. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor s high quality, innovative products are the most comprehensive in the industry. 2008 System Sensor. The company reserves the right to change specifications at any time. A05-0363-008 10/08 #2036