EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

Similar documents
EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

IES308. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

4 Channel Contact Closure SFP DIN Fiber Link System

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

UNC100 Integra Manual

Installation Instruction Manual ILS-S

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

IntelliDoX Operator Manual

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Experion LX Direct Station Specification

SAILOR 6101 and 6103 Alarm Panel. Installation and user manual

Owner s Manual. PIR-1 IR Learner

EOTec 2C32 Installation Guide

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Fratech Multipath-IP

VA301C CONTROLLER WITH BACnet OPTION

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

600 Range Dialer Installation Manual. Version 1.0

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

RMS/RPX Reader. User Manual

Bulletin 1608N MiniDySC Dynamic Sag Corrector

VX SERIES Wireless Thermostat with Occupancy Sensor

SEE DISCLAIMER ON REVERSE

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

NWA300 Field-Based Analog 4-20mA DC Current Meter User's Manual OM

IndigoVision Alarm Panel. User Guide

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

M5200 Industrial Pressure Transducer

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

Series: MBC1-TC Mini Benchtop Temperature Controller

Galaxy Pulsar Plus Digital Battery Plant Controller

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

MicrOTDR. Optical Fault Locator. User Manual

Remote / Network Control for Rack Cabinet Access - DL Series

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

M5800 Pressure Transducer with Rotatable Display

Thermometer model 02059

SAFETY INFORMATION AND WARNINGS

T3/E3 Fiber Optic Line Drivers

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Document No

IFS SFP Tranceivers User Manual

Door Release Power Supply

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

High-Speed Voice and Data Link Access Multiplexer

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

PlanarMag Product Technology

QS941A Controller User Interface

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

IFS Fiber Module Installation & Operation Instructions

M5800 Pressure Transducer with Rotatable Display

T4000 Security Communicator

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Static Pressure Control

RS485 MODBUS Module 8AI

Added password for IP setup page : Password must be in IP format!

Model 144H. Product Data Sheet , Rev DB February Content

CD6102 / CD6102 OC / CD6102-2

Model T B Intraoffice T1 Repeater User Manual

! "! # Please read these installation and operating instructions completely and carefully before starting.

Installation Instruction Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Fratech Multipath-IP STU

Dolphin 9900 Mobile Computer

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Dual Input ph/orp Analyzer

Warranty Registration

CPS3200U Technical Support Guide

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Simplex Panel Interface Guide

U5300 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

LevelSET S GSM Functionalities Instructions for Commissioning and Use

U5600. Wireless Pressure Transducer SPECIFICATIONS

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

MTRA-FSP Level Control Relay. Installation & Operation Manual

GPS Evaluation Kit EVA1037/1080

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MiNi Server environment MoNitoriNg SySteM

Operating Instructions SIPLUS CMS4000 MCN11. Preface 1. Product Overview 2 SIPLUS CMS4000. Installation 3. Media Converter Node (MCN11) Wiring 4

Transcription:

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch User s Guide

All Rights Reserved Dissemination or reproduction of this document, or its contents, is not authorized except where expressly permitted. Violators are liable for damages. All rights reserved, for the purposes of patent application or trademark registration. Disclaimer of Liability The information contained in this document is subject to change without notice. EtherWAN is not liable for any errors or omissions contained herein or for resulting damage in connection with the information provided in this manual. Warranty For details on the EtherWAN warranty replacement policy, please visit our web site at: https://kb.etherwan.com/index.php?categoryid=13 Products Supported by this Manual: EX41922-T

Preface Audience This guide is designed for the person who installs, configures, deploys, and maintains the Ethernet network. This document assumes the reader has moderate hardware, computer, and Internet skills. Document Revision Level This section provides a history of the revision changes to this document. Revision Document Version Date Description A Version 1 06/13/2017 Changes in this Revision This is first version of this document. iii

Contents Preface... iii Changes in this Revision... iii Contents... iv Introduction... 5 Unpacking the Hardware... 5 Hardware Features... 6 Front Panel... 6 Preparing the Installation Site... 7 Checking the Installation... 8 Applying DC Power... 8 10/100/1000BASE Ports... 9 Two 100/1000 SFP Slots... 9 Set DIP Switches... 9 Relay Output Alarm... 10 Specifications... 11 Technology... 11 Power... 11 Mechanical... 12 Interface... 12 Environment... 12 Regulatory Approvals... 13 Application Example... 14 iv

Introduction Congratulations on your purchase of the EX41922-T Hardened Unmanaged Power over Ethernet (PoE) Switch from EtherWAN Systems, Inc. Your switch is a state-of-the-art IEEE-compliant network solution designed for users who require high-performance to eliminate bottlenecks and increase productivity. To simplify installation, the switch is shipped ready for use. Unpacking the Hardware Unpack the items and confirm that no items are missing or damaged. Your package should include: One EX41922-T Hardened Unmanaged PoE Switch One CD containing this user s guide One quick start guide If any item is damaged or missing, notify your authorized EtherWAN representative. Keep the carton, including the original packing material, in case you need to store the product or return it. 5

Hardware Features Front Panel 10/100/1000BASE Ports The switch is equipped with two 10/100/1000 Mbps RJ-45 ports. These ports can be connected to routers, other switches, or end devices. Use category 5e or higher UTP/STP cable. 100/1000 SPF Slots Your switch model has two SFP slots. SFP transceivers can be installed directly into these ports. Ensure that the same type of transceiver is used at both ends of the link and that the correct type of fiber cable is used. LEDs The EX41922-T front panel LEDs show power and link/activity status. The table below summarizes the LED indicator functions. 6

Table 0-1. Front Panel LEDs LED Color Status PWR 1, 2 Green ON = switch is receiving power. Fault Red ON = Alarm state - Relay alarm action on switch contact OFF = Non-alarm state PoE Amber ON = Powered device connected OFF = No powered device connected 10/100/1000TX Ports Green ON = valid network connection at 10/100Mbps Link/Activity Amber ON = valid network connection at 1000Mbps OFF = no data transmission on port. Flashing = port is sending or receiving data. 100/1000SPF Ports Link/Activity Green ON = valid network connection at 10/100Mbps Amber ON = valid network connection at 1000Mbps OFF = no data transmission on port. Flashing = port is sending or receiving data. Preparing the Installation Site Before you install your Hardened Unmanaged Switch, be sure your operating environment meets the operating environment requirements in the table below. Site Requirements Characteristic Requirements DIN Rail Mounting Power source Environment Temperature Operating humidity Ventilation Insert the top of the rail clip onto the DIN rail track, and then push the bottom of the switch until it snaps into place. Provide a power source within 6 feet (1.8 meters) of the installation location. Power specifications for the Hardened Unmanaged Switch are shown in Appendix A. Install the Hardened Unmanaged Switch in a dry area, with ambient temperature between -40 and 75ºC (-40 and 167ºF). The installation location should have a maximum relative humidity of 95%, non-condensing. Do not restrict airflow by covering or obstructing the top and side panels of the Hardened Unmanaged Switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. 7

Checking the Installation Before you apply power: Inspect the equipment thoroughly. Verify that all cables are installed correctly. Check cable routing to make sure cables are not damaged or create a safety hazard. Be sure all equipment is mounted properly and securely. Applying DC Power The switch is equipped with an 8-pin terminal block, with two power inputs having operating voltage of 52~57VDC, and a relay output with current 0.5A @ 48VDC. Only one power input is required to operate the switch. However, redundant power supply functionality is supported. When you apply power: All green Link/Activity LEDs blink momentarily. The green Power LED goes ON. The Link/Activity LEDs for every port connected to a device flash, as the Hardened Unmanaged Switch conducts a brief Power On Self-Test (POST). 8

10/100/1000BASE Ports The switch is equipped with two 10/100/1000BASE-T PoE IEEE802.3at 30 Watts each, with a total PoE power budget of 60 Watts. These ports can be connected to routers, other switches, or powered devices. Use category 5e or higher UTP/STP cable. Two 100/1000 SFP Slots Your switch model has two SFP slots. SFP transceivers can be installed directly into these ports. Ensure that the same type of transceiver is used at both ends of the link and that the correct type of fiber cable is used. Set DIP Switches The switch has a 6-position DIP switch that controls the alarm status on each port. Alarms are sent through the relay output. DIP Switch 1 2 3 4 5 6 Setting and Description ON = Port 1 Alarm is enabled. OFF = Port 1 Alarm disabled. ON = Port 2 Alarm is enabled. OFF = Port 2 Alarm disabled. ON = Port 3 Alarm is enabled. OFF = Port 3 Alarm disabled. ON = Port 4 Alarm is enabled. OFF = Port 4 Alarm disabled. ON = Port 3 100SFP is enabled. OFF = Port 3 100SFP disabled. ON = Port 4 100SFP is enabled. OFF = Port 4 100SFP disabled. 9

Relay Output Alarm Alarm Contact (for two power inputs: PW1, PW2). Default state is PW1 and PW2 both off, Points 1 & 2 closed and Points 2 & 3 open. Relay contact PW1 PW2 Points 1 & 2 Points 2 & 3 Alarm state Off Off Closed Open Alarm state Off On Closed Open Alarm state On Off Closed Open Non-Alarm On On Open Closed 10

Specifications Technology Specification Standards Forward and Filtering Rate Packet Buffer memory Processing Type Jumbo Frame Address Table Size Description IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX/100BASE-FX IEEE802.3ab 1000BASE-T IEEE802.3z 1000BASE-SX/1000BASE-LX IEEE802.1x, Full duplex flow control IEEE802.1az Energy Efficient Ethernet IEEE802.3af/at Power Over Ethernet 10 Mbps: 14,880 pps 100 Mbps: 148,810 pps 1000 Mbps: 1,488,100 pps 1MB Store-and-Forward Half-duplex back-pressure and IEEE802.3x full-duplex flow control Auto Negotiation Auto MDI/MDIX 10 kb 8K MAC addresses Power Specification Power Input: Power Consumption: 52 ~ 57 VDC 63.6W@52VDC, 63.8W@57VDC Description 11

Mechanical Specification Description Casing Aluminum IP30 Dimensions 42 x 90 x 100mm (W x D x H) (1.65 x 3.54 x 3.94 ) Weight Installation 0.37Kg (0.82lbs.) DIN-Rail Interface Specification Ethernet Ports LED Indicators 10/100/1000BASE-T: 2 ports 1000BASE SFP: 2 ports Description Per Unit: Power1 (Green), Power2 (Green), Fault (Red) Per Port: Link & Activity (Green, Amber), PoE (Amber) Environment Specification Operating Temperature Storage Temperature Ambient Relative Humidity -40 C to 75 C (-40 F to 167 F) -40 C to 85 C (-40 F to 185 F) 5% to 95% (non-condensing) Description 12

Regulatory Approvals Specification Description ISO Safety UL 61010 EMI Manufactured in an ISO 9001 facility FCC Part 15B Class A VCCI Class A EN 61000-6-4 EMS EN 61000-6-2 EN 61000-4-2 (ESD Standards) EN 61000-4-3 (Radiated FRI Standards) EN 61000-4-4 (Burst Standards) EN 61000-4-5 (Surge Standards) EN 61000-4-6 (Induced RFI Standards) EN 61000-4-8 (Magnetic Field Standards) Environmental Test Compliance IEC 60068-2-6 Fc (Vibration) IEC 60068-2-27 Ea (Shock) FED STD 101C Method 5007.1 (Free fall w/ package) 13

14 Application Example

EtherWAN System, Inc. www.etherwan.com USA Office 4570 E. Eisenhower Circle Anaheim, CA 92807 TEL: +1-714-779-3800 Email: info@etherwan.com Pacific Rim Office 8F., No.2, Alley 6, Lane 235, Baoqiao Rd. Xindian District, New Taipei City 231 Taiwan TEL: +886-2- 6629-8986 Email: info@etherwan.com.tw EtherWAN has made a good faith effort to ensure the accuracy of the information in this document and disclaims the implied warranties of merchantability and fitness for a particular purpose, and makes no express warranties, except as may be stated in its written agreement with and for its customers. EtherWAN shall not be held liable to anyone for any indirect, special or consequential damages due to omissions or errors. The information and specifications in this document are subject to change without notice. Copyright 2018. All Rights Reserved. All trademarks and registered trademarks are the property of their respective owners. User Guide January 2, 2018 Document version: Version 1