FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

Similar documents
No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

HX-80NRAM. High Mount Outdoor Detector

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

RLS-3060SH REDSCAN ULTIMATE

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

RLS-3060SH REDSCAN ULTIMATE

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Description. Optex Incorporated

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR ENGLISH FEATURES FRANÇAIS DEUTSCH INSTALLATION HINTS

D-Tect 2 GJD300 Quad PIR Movement Detector

VX-402, VX-402REC CONTENTS FEATURES

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

English. Italiano. Português. Françias. Español

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

D-TECT 3 IP. GJD260 IP Motion Detector

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

PHOTOELECTRIC DETECTOR

Movement Detector GJD 300

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Intrusion Outdoor Protection Perimeter

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Basic hints for better system design for Redwall PIR detector

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Detector Application Notes

DD205RF/TX Detector Installation Sheet

D-TECT 2 IP. GJD230 IP Motion Detector

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Immunity. P/N: ver.b

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

LUX Hardwired - Installation Notes

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

METAL DETECTOR MODEL NO: MD1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: /08

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Advanced DIGITAL Wired PIR Motion Detector

Installation Instructions

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

PHOTOELECTRIC DETECTOR

Passive Infrared Motion Detector 5420/90P. Installation Instructions

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

CS150 OWNER S MANUAL DISCRIMINATOR METAL DETECTOR

LPCMPIRM65 & LPCMPIRDSI65

Twin Photobeam Detectors Manual

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Simple Instructions for the WisePIR

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

High Frequency Sensor

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Installation And commissioning manual. Series S Double Beam 1/16

Welcome. Welcome to the new Optex Event-Driven CCTV catalogue.

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Long-Range Barrier Sensors

DI601AM Outdoor PIR/AM Detector Installation Sheet

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

Viewguard Motion detctors PIR and DUAL detectors

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Movement-based energy control

DATA CENTER SECURITY. March 2017 Anton Panaitescu

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Commercial Series TriTech Motion Detector. Reference Guide

Premier External TD. Installation Manual INS352-3

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

Installation Guide. Home Network System Motion Sensor KX-HNS102HM. Model No.

Motion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.

General Description. Industrial LuNAR DT AM Grade 3 Features

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Installation Instructions

Radar Sensor. Radar Security Detector Model No. : DND-30L/30W, DND-60L/60W, DND-90L/90W. Feature. Specification. Reference

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Installation Manual Premier Elite Orbit QD/DT INS483-2

English. Series. Installation and Use Manual

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Transcription:

6 78 9 No.9-126-4 8-7 PASSIVE INFRARED AND COMBINATI DETECTOR FEATURES OPM-32 and OPM-33 are highly-reliable combination detectors equipped with the Adjustable Microwave Range Limiter Technology and the Dual Quad Zone Logic PIR to detect motion outdoors. 1.DESCRIPTI AND OPERATI MIDI HOOD microwave sensor OPTI OPM-WT (Walk tester) A buzzer goes upon detection in microwave and PIR detection areas. 2.DETECTI AREA sensor unit cover / unit Wiring guide WIDE ANGLE TOP VIEW 1m Cover fastening screw OPM-32 PIR sensor (Near) PIR sensor (Far) Mount visual alignment aid Mounting holes (4 holes) MW distance set Function set GREEN LED PIR detection YELLOW LED Microwave detection RED LED alarm output Alarm output Ball joint NARROW ANGLE TOP VIEW 1m 1 2 3 4 OPM-33 OPM-WT connector Tamper output Ball joint fastening screw Tamper 1m 1 1 2 2 3 SIDE VIEW Microwave area PIR Near area PIR Far area 1m 1 1 2 2 3 SIDE VIEW Microwave area PIR Near area PIR Far area 4m 1 1 2 2 3 4m 1 1 2 2 3

6 7 894 6 7 894 23 461 3.INSTALLATI HINTS Microwave area Fence, Wall Mounting height is 2.4-4.m. Avoid moving objects in the detection area(i.e.swaying trees, bushes, etc.). Aim the detector at wall or the ground, to avoid unwanted detection Set the microwave distance properly to prevent any object outside a fence or a wall from being detected (The microwave may detect any object beyond obstacles). After adjusting the PIR area, firmly fix the sensor unit ball joint. 4.INSTALLATI (1) (2) (3) (4) 78 9 N.O. output N.C. output Tamper output (11-24VDC) (Non Polarity) Use the MIDIHOOD to Sensor Unit with attached screws to avoid mis-operation. Loosen the cover fastening screw and remove the cover. () (6) (7) (8) WIRE SIZE 12V 24V AWG22(.33mm 2 ) 13m 38m AWG2(.2mm 2 ) 2m 6m AWG18(.83mm 2 ) 32m 97m Wire to the P.C.B. unit block through the wiring guide. 1 23 Set each according to installation environment. (See Section and Section 6.) Loosen three ball joint fastening screws and next move the sensor unit to set the PIR area. Make a walk test to check the microwave and PIR areas. (See Section, Section 6 and Section 7.) Tighten the ball joint fastening screws, close the cover, and tighten the cover fastening screws..area setting Set the area of PIR and the microwave. On completion of respective area settings, conduct a walk test (See Section 7) to make sure that a human body is actually detected. -1 Setting the PIR area Set the PIR area in the following manner. (1) Lens masking (2) Setting area with Fin on the sensor unit (3) Setting area with VISUAL PIR sensor(far) Horizontal line HOOD angle ALIGNMENT AID Lens masking plate To check the edge of the detecting area, install the provided lens masking plate to the PIR sensor (Far). To set a desired maximum detection range, adjust the Fin angle of the sensor unit based on the table. Visual alignment aid Mount the Visual alignment aid to the sensor unit. Check the far position sighted through the sight hole, where coincides with the PIR maximum area.then, conduct a walk test. (See section 7.) -2 Setting the microwave sensor detection area Set the area with the on the P.C.B. unit. 1 2 3 Distance set Set the distance with the es to 6. The microwave distance adjusts the detectable distance. An object at a distance shorter than the set value is detected and an object at a distance longer than the set value is cancelled. Due to environmental conditions at the installation site, the detectable distance can be longer and/or shorter than the set position. After the distance is set by the dial, conduct walk-test to confirm the detection distance. And, if necessary, position should be re-adjusted. 1 2 3 6 7 894 Switch Set distance No. Unlimited 1 m 2 1m 3 1m 4 2m 2m 6 3m This function does not work under -2C degree (rated operation temperature). Set to 1m Set to m 1m 1m 4m Set to 2m Set to 1m 1 1 1 1 Set to 2m Set to 3m 2 2 3 2 2 3 [When the distance is set to to 2m ] 1m 1m Detected within this range Not detected beyond this range It is effective to utilize in the place where an alarm error may be caused by moving trees, vinyl sheet, cars, etc. at the distance longer than the set value. HINT: For easy adjustment, set the detection range slightly narrower than a targeted range first, and then expand it gradually during the walk test. 2

6 7 894 6.Function setting Set the following functions with the function set on the P.C.B. unit. 1 2 3 4 6 7 Function set 1 to 4 : Set PIR function. to 7 : Set microwave sensor function. 1.PIR detection mode selector 2.PIR sensitivity selector (Far area) 3.PIR sensitivity selector (Near area) 4.PIR pulse count selector,6.mw Repetitive Movement Discrimination function 7.MW small animal immunity function *OPM-33 is not equipped with Switch 4: Pulse count selector. 6-1 Setting the microwave sensor function 6-1-1 Repetitive Movement Discrimination function Use Switch and Switch 6. 6 OFF Use this position when the area is sterile and there are no objects which could cause false activations. See note below. The unit can cancel bigger moving objects, e.g. big trees and leaves. In this position, the detector requires enough moved distance to detect a human body. Position at delivery AUTO The unit can cancel small repetitive movements in the detection area. In the detection area, if there are not any repetitive movements for a certain period, automatically the mode will be changed to "". Depending on the degree of repetitive movement "" or "" will be selected automatically. If there are objects that can be blown and moved, e.g. vegetation, vinyl sheets, etc., it can be the cause of false alarms. When the unit would be installed at these places, "" or "" position should be selected. When "OFF" is selected, the microwave sensor might detect a little shock or vibration from installation surface (pole and/or wall). If this occurs "" or "" position is recommended. 6-1-2 Small animal immunity function Use Switch 7. : Motions of small animals such as cats and rats are cancelled. 7 OFF:Disable 6-2 Setting the PIR sensor function 6-2-1 PIR detection mode selector 6-2-2 selector Use Switch 1. NORMAL (Position at delivery) NORMAL :Set to this mode normally. 1 -density detection -density detectiion :The sensor performance is improved in this mode. Use the high-density detection mode when the unit is installed in the place where it is difficult to detect a human body due to obstacles in the PIR detection area. If this mode is selected, small animals such as cats and rats can also be detected easily. 4m 7.Walk Test to check the area setting 1 1 2 2 3 Near area <Far area sensitivity selector> Use Switch 2. <Near area sensitivity selector> Use Switch3. 2 3 6-2-3 Pulse count selector (OPM-32 only) Use Switch 4. It is recommended to set to TEST when a Walk Test is carried out. To reduce the alarm error, set to Pulse Count 2 normally. After completing each setting according to Section and Section 6, carry out a walk test finally to check if the microwave sensor and the PIR sensor detect a human body within the set ranges. It is recommended to carry out the walk test with the optional OPM-WT. LRP-12 is not applicable to. [Walk Test procedure] (1) Area setting (2) Wiring, Switch setting REDWALL,REDWIDE MEGARED connection wire Connection select Mode select CNECTI POWER MODE OPM-WT connection wire Speaker Power select Set the Mode select to. Walk around the edge of the set area to make sure that a human body is detected. While OPM-WT emits 2 different sounds, pitch sound and pitch sound, set the area to a position where the high pitch sound is available. When only pitch sound is available in whatever set position, the position of PIR DETECTI MODE OR to -density-detection. (See section 6-2-1) - PIR - Far area The PIR area consists of Far area and Near area. Each sensitivity can be set individually. When a set detection range is narrow, the sensitivity becomes too high especially on the ground within the Far area, which may allow easier detection of small animals. In such a case, the sensitivity of only Far Area to the position. In contrast, when a malfunction occurs frequently in the Near Area, the sensitivity of only Near Area to the position. - Microwave - Distance set Set the PIR area and the microwave detection area (detection range) according to Section - 1 and Section -2. (3) Checking the edge of PIR detection area (4) Checking the edge of the microwave detection area () Final area check Lens masking plate "Power Supply from Sensor" mode of OPM- WT cannot be used for LRP series. "Cell Battery" mode should be used. OPM-WT is optional walk-tester which can confirm the detection area of microwave and PIR by sound. It should be noted that it is impossible to accurately set the correct detection area without the OPM-WT. The Power for the OPM-WT can be selected from OPM-WT Connector on OPM- 32/33 or battery. Install the lens masking plate anterior to the PIR sensor (Far). Try to walk around the edge of the detection area alongside of a fence or a wall. 1 2 3 Set the Mode select to microwave. Walk around the edge of the detection area to make sure that a human body is detected. When detecting a human body, OPT-WT emits a detection sound. When no human body is detected, the Distance set (See Section -2) may be placed in a wrong position; try to check whether the is set properly. 6 7 894 Try to walk around the edge of the detection area alongside of a fence or a wall. OPM-WT connector 1 23 TEST Pulse Count 2 TEST:The pulse count is set to 1.For OPM- 33, it is fixed to 1. REDWALL, REDWIDE 4 Pulse Count 2 :Set to this mode normally. CELL BATTERY POWER SUPPLY FROM SENSOR POWER OFF Insert the connection cable into the OPM-32/33 OPM-WT connector.at the same time, set the Power select to Power supply from sensor, and the Connection select to series. In condition of "Power Supply form Sensor" mode: When cannot work properly due to lack of current by power consumption of OPM-WT, use battery to operate OPM-WT. Set the Mode select to alarm output. At this position, as the sound comes in conjunction with the output of Alarm output, it is possible to check the AND detection of PIR and the microwave. Finally, try to walk around the entire area randomly to make sure that a human body is detected.

8.TROUBLE SHOOTING No operation PROBLEM Yellow LED does not light. No MW beep tones.(opm-wt) (MW does not operats) Yellow LED lights even if no person in detaction area. Green LED does not light. No PIR beep tones.(opm-wt) (PIR does not operats) Green LED lights even if no person in detection area. Red LED does not light. PROBABLE CAUSE Power is not suppljed. Incorrect wiring. power supply. A person is moving beyond the microwave set area. Strong RFI nearby. Moving fan or motor of air-conditioning vents etc. Objects beyond walls and buildings are detected. Weeds/trees and vinyl sheets are swaying in the detection area. Detecting somebody near the sensor. A small animal is moving. Installed in a location subjected to a lot of snow and rain. A person is moving outside the PIR area. Rapid temperature changes in detection area (heating,air conditioning, lneandescent lamp etc.) Moving animals etc. Persons and cars outside the area are detected. The detector is in sunlight or car headlight. Only one of the two, MW or PIR, detects. REMEDY Supply Power. Correct wiring. Supply power between 11-24VDC. Check the microwave set area is correct. (See Section.) Switch electrical equipment off. Change the microwave distance set value to shorten. Minimize motions in the detection area. Select the microwave Repetitive Movement Discrimination function. (See Section 6.) The microwave may detect a human body (moving object) outside the area. Make sure that nobody near the sensor moves even if outside the area. Select the microwave small animal immunity function to.(see Section 6.) It is recommended to attach the optional hood. Set the PIR area appropriately. Remove such objects from detection area. Select the sensitivity to LOW". (See Section 6.) Check the PIR area. Adjust the area to avoid direct sunlight or car headlight. If it is difficult to adjust the area, attach the optional hood. Unless both of MW and PIR detect, the red LED is not lit. Recheck the MW distance setting and the PIR area setting. 9.SPECIFICATIS Model Detection method Coverage Mounting height LED indicator Alarm period Alarm output Tamper Warm up period Current draw Weight Operating temperature Environmental humidity Microwave frequancy IP rating OPM-32 OPM-33 Passive infrared and Microwave 3m x 2m wide 3m x 3m narrow 2.4-4. m GREEN : PIR detection YELLOW : MW detection RED : PIR and MW detection Approx. 2 sec N.C. 28VDC.2A max N.O. 28VDC.2A max N.C. 28VDC.1A max Approx. 6 sec 11-24 VDC 4mA max. ( at 12VDC) 2mA max.( at 12VDC, OPM-WT USED) 1.kg 26 9 max. 1.87GHz [(E)Version] 9.9GHz [(F)Version] IP 3 117 26 mm 277 3 Country of intended use Restrictions United Kingdom 1.87GHz France 9.9GHz OPTEX CO.,LTD. (JAPAN) (ISO91 Certified by LRQA) (ISO141 Certified by JET) -8-12 Ogoto Otsu Shiga 2-11 Japan Tel:+81-77-79-867 Fax:+81-77-79-819 http://www.optex.co.jp/e OPTEX (EUROPE) LTD. (UK) (ISO91 Certified by NQA) Clivemont Road, Maidenhead, Berkshire, SL6 7BU UK Tel:+44-1628-631 Fax:+44-1628-636311 http://www.optexeurope.com OPTEX SECURITY SAS (FRANCE) 7 allée du Crêt. ZA des Monts d Or 6989 La Tour de Salvagny France Tel:+33.4.78.19.67.7 Fax:+33.4.78.19.41.12 http://www.optex-security.com

Over 2 m Important Notice: For proper installation of multiple units without interference of microwave The OPM32/33 series includes models with different microwave frequency types as follows:- OPM-32(E) OPM-32(E)CH.A OPM-32(E)CH.B OPM-32(E)CH.C OPM-33(E) OPM-33(E)CH.A OPM-33(E)CH.B OPM-33(E)CH.C If your site requires the installation of multiple Redwave units mounted in close proximity to each other, then care should be taken to select units with different microwave frequencies. This will eliminate the possibility of microwave crosstalk which could cause false activations of the units. The diagrams below show how to easily configure the Redwave's where multiple units are installed. OPM-32(E)CH.B OPM-32(E)CH.B OPM-32(E)CH.A OPM-32(E)CH.C OPM-32(E)CH.A OPM-32(E)CH.A OPM-32(E)CH.B OPM-32(E)CH.B OPM-32(E)CH.A On the same pole At the corner of the same building At the corners which are closely located Same wall, back to back OPM-32(E)CH.B OPM-32(E)CH.B OPM-32(E)CH.B OPM-32(E)CH.A OPM-32(E)CH.A OPM-32(E)CH.A In parallel In horizontal Face to face If you are installing multiple Redwave units on a site which are all of the same microwave frequency, then the requirements below should be followed. Failure to do this may result in false activations due to microwave crosstalk. Over m Over m Over 2 m Can not be used On the same pole At the corner of the same building At the corners which are closely located Same wall, back to back Over 2 m In parallel In horizontal Face to face Can not be used 91293 OPM 注意書 ( 英文 ).indd 1 26/1/7 11:29:39