USER-MANUAL Tamson Cool Cube Immersion Cooler

Similar documents
USER-MANUAL TC6B-10B-20B-TB

USER-MANUAL TC

USER- MANUAL TV7000MKII

USER-MANUAL TV2000MKII, TV4000MKII, TV4000MKIIDC TV17000

Operator s Manual. IP-100 Immersion Probe Cooler

Thermo-Sealer. Manual Heat Sealer. User Manual

Operator s Manual. Histology Bath

Analog Melting Point Apparatus

Sundirect Infrared Panel Heaters. Installation & Operation Instructions

Manual TV4000LT TV7000LT

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

USE AND MAINTENANCE MANUAL

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

ANTIBACTERIAL HAND VAC WITH UV LIGHT

Popcorn Warmer Cabinet

Owner & Operator s Manual. Table of Contents

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Whole Room Dryer WRD, WRD/110

Dry Bath Heating Systems

Manual TV Tamson Instruments bv

Outdoor Refrigerator USER S MANUAL

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Operations Manual VCS/VCR/VLS

SASE BULL 240C. Dust Collection System Manual

Power 4. User Guide. HC85-P4-ZA hoover.za.com

Spice / Coffee Grinder Instruction Manual

Ice Maker. Model BIM25. Instruction Manual. Write Serial Number of unit here:

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Aluminum Heating Mantles

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

ROTARY VACUUM EVAPORATOR RVO 004

MD-MINI Dry Bath. Instruction Manual

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

TCW 2000 Ice liner refrigerator and freezer PIJ

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

POLYMIX PX-IG 2000 Operating Instructions

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Portable Sous Vide Instruction Manual

User Manual. 2 & 3 Bowl Juice Dispenser. Please read and keep these instructions. Indoor use only. 1

Whynter Portable Ice Maker 33 lb capacity - White

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Instructions for the fan motor control system, SILVER C

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION INSTRUCTION MANUAL FOR MODELS: FS60-FROST

NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

ASPIRE Laboratory Aspirator

Service manual NORDIC. Juice machine S / EN. Rev Din återförsäljare / Your retail dealer

Customers must fill in and mail the warranty card in order to activate the warranty.

NoZone Ozone Scrubber

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

Sip Vacuum Cleaner 1400/35 Wet & Dry

Digital Heat Block User Manual

Model PT-05 Model PT-06

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

INSTRUCTION MANUAL MNBX14

TYPES: GASTRO VK SALAD

ANTIBACTERIAL HAND VAC

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Superdryer Dehumidifiers

Operating Instructions

USER INSTRUCTION MANUAL. Autofill Water Boiler

Models: RP-10, RP-15, RP-20. User Manual

20L Electronic Dehumidifier

V 120 SG - V 160 SG. Instructions for use

User Manual Watt Drop-In Induction Range. Model: DC /2017. Please read and keep these instructions. Indoor use only.

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

Meaco 10L small home dehumidifier Instructional Manual

ascent Installation & maintenance instructions Customer/technical services Guarantee Mono basin filler with infrared sensor GUARANTEE REGISTRATION

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

CREMALDI Cream machines Operating instructions

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

CAKE DISPLAY FRIDGE

User Manual WMF Cup&Cool WMF Cup

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Corning LSE 6L Digital Water Bath

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

USER AND MAINTENANCE MANUAL

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

INSTALLATION & SERVICE BOOKLET. Juice Machine - Postmix JM 6 JM 7

23-IN Electric Logset

TOWER COUNTER TOP STG

Transcription:

USER-MANUAL Tamson Cool Cube Immersion Cooler Page 1/14

1 SAFETY AND WARNINGS... 3 2 WARRANTY... 3 3 DISCLAIMER... 3 4 PRECAUTIONS AND HAZARDS... 4 5 INSTALLATION... 4 5.1 IMPORTANT... 4 6 USE... 5 7 WHAT IS WHAT... 6 7.1 START... 7 7.2 AIR CIRCULATION... 8 8 SPARE PARTS LIST AND PRODUCT CODE... 9 9 WIRING... 10 10 DIMENSIONS... 11 11 TROUBLE SHOOTING... 11 12 CE DECLARATION OF CONFORMITY... 13 Page 2/14

1 SAFETY AND WARNINGS Make sure before installing or operating the equipment to read and understand all instructions and safety precautions listed in this manual. If there are any questions concerning the operation of the equipment or about the information given in this manual, please contact your local dealer or our sales department first. Performance of installation, operation, or maintenance other than those described in this manual may result in a hazardous situation and may void the manufacturer's warranty. Never operate equipment that is not correctly installed. Unqualified personnel must not operate the equipment. Avoid damage to the equipment, or its accessories, caused by incorrect operation. Important: - When performing service, maintenance or moving the apparatus, always disconnect the apparatus at the main's socket, - Proper skilled and trained personnel are only allowed to operate this equipment, - Take notice of warning labels and never remove them, - Refer service and repairs to qualified technician, - If a problem persists, call your supplier or Tamson Instruments b.v. 2 WARRANTY Tamson Instruments b.v. warrants that all their manufactured equipment is free from defects in material and workmanship, preventing the device from normal operation. Tamson Instruments b.v. does not warranty that the equipment is fit for any other use than stated in this manual. The manufacturer can only be held responsible for the security, reliability and performance of the equipment, when operated in accordance with the operating instructions, extensions, adjustments, changes and/or if repair is performed by Tamson Instruments b.v. or authorized persons only. This warranty is limited to one year from the date of invoicing. All equipment and materials are subject to standard production tolerances and variations. 3 DISCLAIMER For relevant measurements always an independent reference measurement is needed. Tamson can not be held responsible for misinterpretation or consequences of an erroneous reading. Page 3/14

4 PRECAUTIONS AND HAZARDS Before attempting to operate the TCC - IC read all parts of this manual carefully to insure smooth operation and avoid damage to the equipment or its accessories. If a malfunction occurs, consult section "Trouble shooting, page 11. If the problem persists email us at: service@tamson.com. Never operate the equipment if not correctly installed. The equipment must be operated only by qualified personnel. Avoid damage to the equipment or its accessories through incorrect operation. Environment Panel sealing Confirms EN60529: IP65 Environment Temperature 0 tot 35 C. Supply enough ventilation Humidity Atmosphere Pollution cat. 2 5 tot 95 %, non condensating Not suited for altitudes above 2000m or explosive/corrosive environment Conducting pollution must be prevented REMOVE ALL PACKAGE MATERIAL READ CAREFULLY 5 INSTALLATION 5.1 Important is not responsible for any consequential damage or harm caused by using this TCC - IC. Repairs on the electrical system of the TCC IC may only be carried out by well trained and authorized persons. Unpacking Before leaving the factory Tamson products are adequately packed to prevent damage during normal transportation. Check the packing for external damage and make a note on the shipping documents if any damage is found. Always retain the cartons and packing material until the product has been tested and found in good condition. (Transport companies generally will not honor a claim for damage if the respective packing material is not available for examination). Mount spacers Mount the two spacers at the backside of the TCC-IC apparatus. MOUNT SPACERS Page 4/14

6 Use Put the unit in its proper place. Leave enough room around the cryostat for sufficient air circulation. Place the unit in a clean working environment and keep away from dust. When air can not circulate well the cryostat will overheat itself resulting in irreversible and severe mechanical damage. Dust will block the condenser and might also cause overheating of the system. Overheating will cause severe damage to the compressor. The cold finger can be placed in the TLV25 holder, next to the three opening lids for the viscometer holders. When the TLV25 is fully filled with methanol the cryostat can be switched-on. In all cases water is not recommended to use in combination with a cryostat. Water will freeze very quick around the cooling coil preventing proper energy exchange between the cold finger and the bath fluid. It is possible to cool down other processes with the cold finger i.e. rapidly lower temperature in hot fluids. It is not recommended to permanently cool fluids with a temperature above 80 C. Pressure inside the evaporator circuit will be extremely high and can cause severe thermal damage to the compressor. KEEP AIR FLOW FREE ROOM FOR AIR CIRCULATION >10cm >10cm >10cm Regularly check: The apparatus to see if airflow is not blocked around apparatus, Apparatus and condensor are free from dust, Hose is not mechanically damaged. It is advised not to move the refrigeration hose at low temperatures. Only move the apparatus and hose when switched-off and cold finger at room temperature. TLV25 Page 5/14

7 What is what 1 Indicator on / off 2 On / off switch 3 Pressure valve open 4 System error 5 High pressure 6 Pressostat stage 2 7 Pressostat stage 1 8 Compressor stage 2 running 9 Compressor stage 1 running X Not used 1 x x 8 9 3 4 5 6 7 2 Page 6/14

7.1 Start 2 Place the probe [1] in the viscometer bath TLV25 Switch on the apparatus [2] After approximately 30 seconds the compressor starts indicated by the green LED [3] After approximately 300 seconds the compressor of the second stage starts indicated by the green LED [3] 3 After a few seconds the probe starts to cool. Always keep the probe [1] in an vertical position 1 ALWAYS USE PROBE VERTICAL Page 7/14

7.2 Air circulation The system transfers heat from the probe to the ambient. It therefore uses airflow. In order to work properly free airflow should be available. The system must be kept free 10 cm from all sides. KEEP AIR FLOW FREE Keep backside and sidepanels free for air circulation ROOM FOR AIR CIRCULATION >10cm >10cm >10cm Page 8/14

8 Spare parts list and product code Ordering code 00T0300 00T0301 00T0302 Product code Description Tamson Cool Cube Immersion Cooler 230V / 50Hz Tamson Cool Cube Immersion Cooler 230V / 60Hz Tamson Cool Cube Immersion Cooler 115V / 60Hz Ordering code 24T7085 24T7086 24T7091 24T8544 28T4355 28T4354 06T0462 06T0464 24T0029 28T8006 28T1209 Image Sparepart - list Description Swing Wheel Swing Wheel with break/lock Mounting Pin Wheel Mains Switch Front Foil With Status Indicators Type Foil PCB, Mains Circuit Board Display Board Power Supply 24V/1,1A Wide Range Input Fan Motor Adjustment Key - Pressostat P20EA Johnson Control Page 9/14

9 Wiring C1 = Compressor stage 1 C2 = Compressor stage 2 C1 C2 Valve Switched Mode Power Supply 24T0029 24Vx1,1A Fuse 2A - T Mains in P1 = Compressor stage 1 P2 = Compressor stage 2 P3 = Valve P1 P2 P3 Page 10/14

10 Dimensions Dimensions Probe Remark Diameter 46 [mm] Length probe 200 [mm] Length hose + probe 2200 [mm] Dimensions Casing Height + display 660 [mm] Height casing (without display) 610 [mm] Width 380 [mm] Depth (casing) 830 [mm] Do not operate backside directly to the wall Depth with distance spacers 920 [mm] Enabling airflow at backside Weight 76 [kg] Power consumption Initial start (first 15 min. max) 2600W During first starting minutes Working load 1500W max During normal operation Working conditions (ambient) Temperature 15..26 [ C] Humidity 10..90 [%] relative humidity 11 Trouble shooting Electronics seem to be "dead" Check fuse : Replace fuse by 2A-T. So 2 ampère, slow. Fuse can be accessed by removing right side panel. FUSE Page 11/14

Compressor (C1 or C2) do not run Check apparatus for dust. : Remove all dust using a vacuum cleaner. Do not use pressurised air. Fan makes noise Check fans inside for blocking : Remove dust or litter sucked in. Ice forming on probe Water vapour in the air condensates on the top of the cold finger. In time this ice will grow, forming a block of ice. : Turn off the cryostat and let the ice melt. Prevent air from forming condensate by insulating the cold finger. System does not cool down Ice forming (crystals) on the probe. : Use new methanol Do not use ethanol Page 12/14

12 CE DECLARATION OF CONFORMITY Following equipment is in complience with EMC Directive 2014/30/EU: Product: Model: Serial code: Manufacturer: Thermostatic bath and circulator TCC - IC TCC - B Effective from 17Txxx 2665 JL Bleiswijk The Netherlands The products are in conformity with the following specifications: Item Reference Description Test result a RoHS Directive 2011/65EU p b EN61010-2-010 Safety requirements for electrical equipment for measurement, control, and laboratory use. Particular requirements for laboratory equipment for the heating of material p pi c Machine Directive 2006/42/EC Machinery Directive, of the European Parliament and of the Council of 17 May 2006/42/EC 2nd Edition June 2010 d EN 60204 Machinery Directive and Safety p, p i requirements e EN60950-1 Low Voltage Directive p f EN61000-3-2:2014 Harmonics p g EN61000-3-3 Flicker p h EN61000-4-2 +A1+A2 ESD p j EN61000-4-3 +A1+A2 Radiated immunity p (anechoic room) k EN61000-4-4 Electrical Fast Transients Minimum requirements pass l EN61000-4-5+A1 Surges Minimum requirements pass m EN61000-4-6+A1 Conducted immunity p n EN61000-4-11 +A1 Voltage dips and Voltage variations p o EN55016-2-1 Conducted emission p p EN55016-2-3 Radiated emission p (anechoic room) q Pr EN 378 Refrigerating systems and heat pumps - Safety and environmental requirements r EN 13445-5 PED Inspection and Testing Maximum working pressure level of 30 Bar is confirmed. On each apparatus following pressure and leak tests have been carried out with positive result - Low pressure side 20 Bar - High pressure side 30 Bar = Pass = Individually tested p Page 13/14

not applicable were: Conducted discontinuous emissions (Clicks) Radiated emission (OATS) Magnetic field immunity The equipment conforms with all the specifications and norms in this regard. The equipment conforms without any further notice. Entity responsible for marking this declaration : Manufacturer,,, Bleiswijk The Netherlands, Name : R.C. van Hall Function : Director Date : January, 2018 Version : 1.04 Page 14/14