High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Similar documents
FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Concealed Ducted Split Series R-407C MBH

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

PAJ3. Product Specifications

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

PACKAGE AIR CONDITIONER

MAC-120HE-03 Air-Cooled Chiller

EHH SERIES DRAW THROUGH FAN COILS CFM

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

PAR5. Product Specifications

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

WJH4 Product Specifications

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

WCH5**4. Product Specifications

General Description. Operation

VariCool VAV Engineering Guide

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

16 SEER TWO-STAGE AIR CONDITIONERS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Wall Mounted Split Systems

Advance Release September 2009

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Specifications. Vertical Floor Consoles By First Co.

Condensing Units CUS 15-60

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

C13-Series Engineering Guide

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Wall Mounted Air Conditioners with Gas Heat Models AVGA

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

R4H4. Product Specifications

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

WALL-MOUNT HEAT PUMPS - (60HZ)

Ruud Commercial Achiever Series Package Gas Electric Unit

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

13 GEP A L P - 1 A

N4H4. Product Specifications

GREEN REFRIGERANT R-410A

SKYPAK II, 3 Ton Series, gives you a

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

13 SEER CONDENSING UNITS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

N4A6. Product Specifications

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Advance Product Data

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

RGE 13 A T - 1 A

Transcription:

High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007

R - 410a 50Hz Introduction: Established in the year 2004, we specialize in manufacturing of central air-conditioning and kitchen ventilation equipment, with a full-fledged manufacturing facility in Dubai Investments Park (DIP). We provide quality HVAC solutions for residential, commercial & specialized applications. Our vast experience and engineering skills allows us to offer true value added benefits to our clients. TROSTEN I Ducted Split Air Conditioners

Introduction... 01 Nomenclature... 02 Salient Features... 03 Product Specifications... 05 System Performance Data... 07 Fan Performance Data... 21 Electrical Data... 22 Recommended Pipe Selection... 23 Dimensional Drawings... 25 Wiring Diagrams... 29 Guide Specification... 34 ESMA certified split indoor and outdoor series by Trosten provides not only the ultimate comfort, but also long and trouble free operations. These products are registered under the Emirates Conformity Assessment Scheme (ECAS) based on compliance to the following requirements. UAE.S 5010-5:2014 Labeling Energy Efficiency label for electrical appliances Part 5: Commercial and Central Air Conditioners. ECAS specific requirements for registration of low voltage equipment.

Nomenclature Outdoor Unit 6: 220-240V/1Ph/50Hz 1: R-410 a 7: R-407 c Indoor Unit 6: 220-240V/1Ph/50Hz 1: R-410 a 7: R-407 c

Indoor Salient Features The concealed ductable split units are of compact and energy efficient design, delivering ultimate performance. The units provide solutions for most of the domestic and commercial applications, designed with the optimum comfort, installation time-savings and reduced running costs for the end-user. The concealed ductable indoor units are designed using the latest fan coil technology, highly efficient in performance and ideal for whisper quiet operation. The indoor air compartment is completely insulated with fire retardant polyethylene insulation. Units are designed with advanced refrigerant circuiting offering minimal pressure drop for ideal performance. The units are made out of high quality galvanized steel for reliability and durability. The concealed ductable indoor units are available with the electrical characteristics of 220-240 volts, 1 phase, 50 hz operation. The control voltage is 220 volts. Factory assembled controls with 220 volts wired remote controller (wireless remote controller is optional). Units are completely factory wired with single point power input, provided with knockouts for utility, main power supply and control connections. The evaporator coils are made out of seamless, inner grooved copper tube / corrugated aluminum fins. Efficient and dependable metering of the refrigerant is provided by thermostatic expansion device or flow restrictor, a device which improves overall system reliability and is easily accessible for routine maintenance. 03

Salient Features Outdoor The outdoor condensing units of TAC series are suitable for side and top discharge installation on the roof or on the ground. Units have been incorporated with high efficiency rotary / scroll compressor in single stage operation for improved comfort, performance and reliability. Units are designed & tested in accordance with AHRI standards. The outdoor condensing units are available with the electrical characteristics of 220-240 volts, 1 phase, 50 Hz operation up to 11 kw nominal cooling capacity and thereafter by 380-420 volts, 3 phase, 50 Hz operation. Compressors are fully hermetic rotary or scroll type designed for high efficiency and provided with standard controls & safety devices. Higher capacity compressors are provided with crankcase heaters to warm oil and prevent dilution by refrigerant. HP and LP controls for models above 11 kw are provided for the safe operation of the compressor. Units are provided with easy accessible control box, compressor and High pressure switch. Condenser fans are propeller type, direct driven, draw through side / vertical discharge with fan guard mounted to the panel. The fan design provides an efficient airflow rate while operating at low rotational speeds to reduce fan noise. The design incorporates robust characteristics that provide good performance over a range of static pressure. Condenser coils are made of seamless, inner grooved copper tube and aluminum corrugated fins, mechanically bonded for maximum heat transfer TAC units have significant performance advantages in terms of efficiency, noise performance and power consumption. The condenser coils are factory tested for leaks and pressure tested at 600 psig. The outdoor units are leak tested with electronic machines and fully charged with refrigerant R410a. The outdoor units are made out of high quality galvanized steel, powder coated for long lasting protection and durability. 04

Product Specification T1 T3 Outdoor Unit Indoor Unit Model Cooling Capacity Power Input EER Cooling Capacity Power Input EER Fan Type Air Flow Rate Coil Fan Coil Fan Compressor External Static Pressure Power Input Fan Motor Protection Material Tube Diameter Material Fin No.of Rows Condensate Drain Size Air Filter System Operation Control Unit Dimension H x W x D Weight Power Supply Air Discharge Compressor Type Quantity Vibration Isolator Protective Device Fan Type / Drive Quantity Fan Speed Blade Material Tube Construction Tube Material Fin No.of Rows Unit Dimension Weight Pipe Size Refrigerant Power Supply Indoor Unit TDF-G06S1N6 TDF-G08S1N6 TDF-G10S1N6 TDF-G12S1N6 Outdoor Unit TAC-G18D1N6 TAC-G24D1N6 TAC-G30D1N6 TAC-G36D1N6 Btu/hr 17,300 21,600 25,600 34,890 W 1,650 2,070 2,560 3,210 Btu/hr / W 10.5 10.4 10.0 10.9 Btu/hr 15,400 18,800 22,400 29,800 W 1,890 2,310 2,750 3,670 Btu/hr / W 8.1 8.1 8.1 8.1 Double Inlet Double Width CFM 490 740 850 1,200 Inches wg 0.1 0.1 0.1 0.2 W 140 210 220 380 Auto Reset Thermal Overload Inner Grooved Copper Tube Inches 5/16" 5/16" 3/8" 3/8" Aluminum 3 3 3 3 Inches 3/4" Synthetic, Washable Wired Controller With Remote mm 245 x 1025 x 469 245 x 1025 x 469 245 x 1255 x 469 378 x 1100 x 660 kg 25 25 30 70 V / Ph / Hz Type 220-240 / 1 / 50 Side Rotary Scroll No. 1 1 1 1 Rubber Mount Auto Reset Thermal Overload Propeller / Direct Drive No. 1 1 1 2 RPM 900 900 825 900 ABS Fin Tube Construction Inner Grooved Copper Tube Aluminum 2 2 2 2 H x W x D mm 650 x 870 x 320 650 x 870 x 320 1050 x 925 x 395 1150 x 925 x 395 kg 62 63 101 106 Suction 1/2" 5/8" 5/8" 5/8" Inches Liquid 1/4" 1/4" 3/8" 3/8" Type R-410a No. of Circuits 1 1 1 1 V / Ph / Hz 220-240 / 1 / 50 Notes: T1 Condition: Rated at 80.6 0 F DB, 66.2 0 F WB & 95 0 F ambient temperature. T3 Condition: Rated at 84.6 0 F DB, 66.2 0 F WB & 115 0 F ambient temperature. Specifications are subject to change without notice in accordance with our policy of continous research and product development. 05

Product Specification T1 T3 Outdoor Unit Indoor Unit Model Cooling Capacity Power Input EER Cooling Capacity Power Input EER Fan Type Air Flow Rate Coil Fan Coil Fan Compressor External Static Pressure Power Input Fan Motor Protection Material Tube Diameter Material Fin No.of Rows Indoor Unit TDF-G14S1N6 TDF-G16S1N6 TDF-G20S1N6 Outdoor Unit TAC-G42D1N5 TAC-G48D1N5 TAC-G60D1N5 Btu/hr 39,000 46,640 51,600 W 3,750 4,370 4,860 Btu/hr / W 10.6 10.7 10.6 Btu/hr 34,000 38,800 43,700 W 4,190 4,780 5,340 Btu/hr / W 8.1 8.1 8.2 Double Inlet Double Width CFM 1,382 1,600 1,800 Inches wg 0.2 0.2 0.2 W 400 440 690 Auto Reset Thermal Overload Inner Grooved Copper Tube Inches 3/8" 3/8" 3/8" Aluminum 3 4 3 Condensate Drain Size Inches 3/4" Air Filter Synthetic, Washable System Operation Control Wired Controller with Remote Unit Dimension H x W x D mm 378 x 1100 x 660 378 x 1100 x 660 435 x 1200 x 700 Weight kg 73 75 82 Power Supply V / Ph / Hz 220-240 / 1 / 50 Air Discharge Type Side Top Compressor Type Scroll Quantity No. 1 1 1 Vibration Isolator Rubber Mount Protective Device Auto Reset Thermal Overload Fan Type / Drive Propeller / Direct Drive Quantity No. 2 1 1 Fan Speed RPM 900 1,050 1,050 Blade Material ABS Metal Tube Construction Fin Tube Construction Material Tube Inner Grooved Copper Tube Fin Aluminum No.of Rows 3 2 2 Unit Dimension H x W x D mm 1150 x 925 x 395 830 x 765 x 765 830 x 765 x 765 Weight kg 110 136 136 Pipe Size Refrigerant Suction 3/4" 3/4" 3/4" Inches Liquid 3/8" 3/8" 1/2" Type R-410a No. of Circuits 1 1 1 Power Supply V / Ph / Hz 380-415 / 3 / 50 06 Notes: T1 Condition: Rated at 80.6 0 F DB, 66.2 0 F WB & 95 0 F ambient temperature. T3 Condition: Rated at 84.6 0 F DB, 66.2 0 F WB & 115 0 F ambient temperature. Specifications are subject to change without notice in accordance with our policy of continous research and product development.

System Performance Data Indoor TDF - G06S1N6 R - 410a / 50 Hz Outdoor TAC - G18D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 15.46 13.75 13.63 12.11 12.89 11.46 11.64 10.35 kw 4.53 4.03 3.99 3.55 3.78 3.36 3.41 3.03 490 / 231 (High) PI kw 1.60 1.80 2.00 2.26 MBH 16.44 15.94 15.60 15.13 14.63 14.19 11.98 11.62 kw 4.82 4.67 4.57 4.43 4.29 4.16 3.51 3.41 PI kw 1.67 1.86 1.91 2.34 MBH 17.91 15.92 16.42 14.60 15.94 14.29 12.61 11.21 kw 5.25 4.67 4.81 4.28 4.67 4.19 3.70 3.29 PI kw 1.70 1.84 1.95 2.31 MBH 14.23 12.65 12.54 11.14 11.86 10.55 10.71 9.52 kw 4.17 3.71 3.68 3.27 3.48 3.09 3.14 2.79 450 / 212 (Medium) PI kw 1.56 1.75 1.94 2.19 MBH 15.12 14.67 14.35 13.92 13.58 13.17 11.03 10.69 kw 4.43 4.30 4.21 4.08 3.98 3.86 3.23 3.13 PI kw 1.62 1.81 2.00 2.27 MBH 16.47 14.64 15.10 13.43 14.79 13.15 11.61 10.32 kw 4.83 4.29 4.43 3.94 4.33 3.85 3.40 3.02 PI kw 1.65 1.79 2.03 2.25 MBH 13.09 11.64 11.53 10.25 10.91 9.70 9.85 8.76 kw 3.84 3.41 3.38 3.01 3.20 2.84 2.89 2.57 400 / 189 (Low) PI kw 1.51 1.70 1.89 2.13 MBH 13.91 13.49 13.20 12.81 12.49 12.12 10.14 9.84 kw 4.08 3.95 3.87 3.75 3.66 3.55 2.97 2.88 PI kw 1.57 1.76 1.94 2.21 MBH 15.16 13.47 13.90 12.35 13.61 12.10 10.68 9.49 kw 4.44 3.95 4.07 3.62 3.99 3.55 3.13 2.78 PI kw 1.61 1.74 1.98 2.19 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 07

System Performance Data Indoor TDF - G06S1N6 R - 410a / 50 Hz Outdoor TAC - G18D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 14.69 13.06 12.95 11.51 12.25 10.89 11.06 9.83 kw 4.31 3.83 3.79 3.37 3.59 3.19 3.24 2.88 446 / 210 (High) PI kw 1.59 1.79 1.98 2.24 MBH 15.61 15.14 14.82 14.37 14.02 13.60 11.38 11.04 kw 4.58 4.44 4.34 4.21 4.11 3.99 3.34 3.24 PI kw 1.65 1.84 1.92 2.32 MBH 17.01 15.12 15.60 13.87 15.28 13.58 11.98 10.65 kw 4.99 4.43 4.57 4.07 4.48 3.98 3.51 3.12 PI kw 1.69 1.83 1.96 2.29 MBH 13.51 12.01 11.91 10.59 11.27 10.02 10.18 9.05 kw 3.96 3.52 3.49 3.10 3.30 2.94 2.98 2.65 410 / 193 (Medium) PI kw 1.54 1.74 1.93 2.18 MBH 14.36 13.93 13.63 13.22 12.90 12.51 10.47 10.16 kw 4.21 4.08 4.00 3.88 3.78 3.67 3.07 2.98 PI kw 1.61 1.79 1.98 2.25 MBH 15.65 13.91 14.35 12.76 14.05 12.49 11.03 9.80 kw 4.59 4.08 4.21 3.74 4.12 3.66 3.23 2.87 PI kw 1.64 1.78 2.02 2.23 MBH 12.43 11.05 10.96 9.74 10.37 9.22 9.36 8.32 kw 3.64 3.24 3.21 2.85 3.04 2.70 2.74 2.44 364 / 172 (Low) PI kw 1.50 1.69 1.87 2.12 MBH 13.22 12.82 12.54 12.16 11.87 11.51 9.64 9.35 kw 3.87 3.76 3.68 3.57 3.48 3.37 2.82 2.74 PI kw 1.56 1.74 1.92 2.19 MBH 14.40 12.80 13.20 11.74 12.93 11.49 10.14 9.02 kw 4.22 3.75 3.87 3.44 3.79 3.37 2.97 2.64 PI kw 1.59 1.73 1.96 2.17 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 08

System Performance Data Indoor TDF - G08S1N6 R - 410a / 50 Hz Outdoor TAC - G24D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 19.02 16.91 16.44 14.62 14.95 13.29 13.50 12.00 kw 5.57 4.96 4.82 4.28 4.38 3.90 3.96 3.52 740 / 349 (High) PI kw 2.01 2.17 2.32 2.62 MBH 20.52 19.90 18.82 18.25 17.86 17.32 13.90 13.48 kw 6.01 5.83 5.51 5.35 5.23 5.08 4.07 3.95 PI kw 2.09 2.24 2.33 2.71 MBH 22.36 19.87 19.81 17.61 19.46 16.58 14.63 13.00 kw 6.55 5.82 5.81 5.16 5.70 4.86 4.29 3.81 PI kw 2.13 2.22 2.38 2.69 MBH 17.50 15.56 15.12 13.45 13.76 12.23 12.42 11.04 kw 5.13 4.56 4.43 3.94 4.03 3.58 3.64 3.24 680 / 321 (Medium) PI kw 1.95 2.11 2.26 2.55 MBH 18.88 18.31 17.31 16.79 15.74 15.27 12.78 12.40 kw 5.53 5.37 5.07 4.92 4.61 4.48 3.75 3.63 PI kw 2.03 2.17 2.32 2.64 MBH 20.57 18.28 18.22 16.20 17.15 15.25 13.46 11.96 kw 6.03 5.36 5.34 4.75 5.03 4.47 3.94 3.51 PI kw 2.07 2.15 2.36 2.61 MBH 16.10 14.31 13.91 12.37 12.66 11.25 11.43 10.16 kw 4.72 4.19 4.08 3.63 3.71 3.30 3.35 2.98 600 / 283 (Low) PI kw 1.90 2.05 2.19 2.48 MBH 17.37 16.85 15.93 15.45 14.49 14.05 11.76 11.41 kw 5.09 4.94 4.67 4.53 4.25 4.12 3.45 3.34 PI kw 1.98 2.11 2.25 2.56 MBH 18.92 16.82 16.76 14.90 15.78 14.03 12.38 11.01 kw 5.55 4.93 4.91 4.37 4.63 4.11 3.63 3.23 PI kw 2.01 2.09 2.30 2.54 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 09

System Performance Data Indoor TDF - G08S1N6 R - 410a / 50 Hz Outdoor TAC - G24D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 18.07 16.06 15.62 13.88 14.20 12.63 12.83 11.40 kw 5.30 4.71 4.58 4.07 4.16 3.70 3.76 3.34 673 / 317 (High) PI kw 1.99 2.15 2.30 2.60 MBH 19.49 18.91 17.88 17.34 16.26 15.77 13.20 12.81 kw 5.71 5.54 5.24 5.08 4.76 4.62 3.87 3.75 PI kw 2.07 2.22 2.37 2.69 MBH 21.24 18.88 18.82 16.73 17.71 15.75 13.90 12.35 kw 6.22 5.53 5.51 4.90 5.19 4.62 4.07 3.62 PI kw 2.12 2.20 2.41 2.66 MBH 16.62 14.78 14.37 12.77 13.07 11.62 11.80 10.49 kw 4.87 4.33 4.21 3.74 3.83 3.40 3.46 3.07 619 / 292 (Medium) PI kw 1.94 2.09 2.24 2.53 MBH 17.93 17.40 16.45 15.95 14.96 14.51 12.15 11.78 kw 5.26 5.10 4.82 4.68 4.38 4.25 3.56 3.45 PI kw 2.02 2.16 2.30 2.62 MBH 19.54 17.37 17.31 15.39 16.30 14.49 12.78 11.37 kw 5.73 5.09 5.07 4.51 4.78 4.25 3.75 3.33 PI kw 2.06 2.14 2.34 2.59 MBH 15.29 13.60 13.22 11.75 12.02 10.69 10.86 9.65 kw 4.48 3.98 3.87 3.44 3.52 3.13 3.18 2.83 546 / 258 (Low) PI kw 1.88 2.03 2.17 2.46 MBH 16.50 16.00 15.13 14.68 13.76 13.35 11.17 10.84 kw 4.84 4.69 4.43 4.30 4.03 3.91 3.27 3.18 PI kw 1.96 2.10 2.23 2.54 MBH 17.98 15.98 15.93 14.16 14.99 13.33 11.76 10.46 kw 5.27 4.68 4.67 4.15 4.39 3.91 3.45 3.06 PI kw 2.00 2.08 2.28 2.52 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 10

System Performance Data Indoor TDF-G10S1N6 R - 410a / 50 Hz Outdoor TAC-G30D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 22.54 20.04 19.48 17.32 17.72 15.75 16.00 14.23 kw 6.61 5.87 5.71 5.08 5.19 4.62 4.69 4.17 851 / 402 (High) PI kw 2.48 2.71 2.91 3.29 MBH 24.32 23.59 22.30 21.63 21.28 20.64 16.47 15.98 kw 7.13 6.91 6.54 6.34 6.24 6.05 4.83 4.68 PI kw 2.59 2.79 2.78 3.41 MBH 26.50 23.55 23.48 20.87 23.18 19.64 17.34 15.41 kw 7.77 6.90 6.88 6.12 6.79 5.76 5.08 4.52 PI kw 2.64 2.76 2.83 3.37 MBH 20.74 18.44 17.93 15.94 16.30 14.49 14.72 13.09 kw 6.08 5.40 5.25 4.67 4.78 4.25 4.31 3.84 780 / 368 (Medium) PI kw 2.41 2.63 2.83 3.20 MBH 22.37 21.70 20.52 19.90 18.66 18.10 15.15 14.70 kw 6.56 6.36 6.01 5.83 5.47 5.30 4.44 4.31 PI kw 2.51 2.71 2.91 3.31 MBH 24.38 21.67 21.60 19.20 20.33 18.07 15.95 14.18 kw 7.14 6.35 6.33 5.63 5.96 5.30 4.67 4.16 PI kw 2.56 2.68 2.97 3.28 MBH 19.08 16.96 16.49 14.66 15.00 13.33 13.54 12.04 kw 5.59 4.97 4.83 4.30 4.40 3.91 3.97 3.53 685 / 323 (Low) PI kw 2.35 2.56 2.75 3.11 MBH 20.58 19.97 18.88 18.31 17.17 16.65 13.94 13.52 kw 6.03 5.85 5.53 5.37 5.03 4.88 4.09 3.96 PI kw 2.44 2.64 2.83 3.22 MBH 22.43 19.94 19.87 17.66 18.70 16.63 14.67 13.04 kw 6.57 5.84 5.82 5.18 5.48 4.87 4.30 3.82 PI kw 2.49 2.61 2.88 3.19 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 11

System Performance Data Indoor TDF-G10S1N6 R - 410a / 50 Hz Outdoor TAC-G30D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 21.42 19.04 18.51 16.46 16.83 14.97 15.20 13.51 kw 6.28 5.58 5.43 4.82 4.93 4.39 4.46 3.96 774 / 365 (High) PI kw 2.46 2.68 2.89 3.26 MBH 23.10 22.41 21.19 20.55 19.27 18.69 15.65 15.18 kw 6.77 6.57 6.21 6.02 5.65 5.48 4.59 4.45 PI kw 2.56 2.77 2.80 3.38 MBH 25.17 22.38 22.30 19.83 20.99 18.66 16.47 14.64 kw 7.38 6.56 6.54 5.81 6.15 5.47 4.83 4.29 PI kw 2.62 2.74 2.86 3.34 MBH 19.70 17.51 17.03 15.14 15.49 13.77 13.99 12.43 kw 5.77 5.13 4.99 4.44 4.54 4.04 4.10 3.64 710 / 335 (Medium) PI kw 2.39 2.61 2.81 3.17 MBH 21.26 20.62 19.49 18.91 17.73 17.20 14.39 13.96 kw 6.23 6.04 5.71 5.54 5.20 5.04 4.22 4.09 PI kw 2.49 2.69 2.89 3.28 MBH 23.16 20.59 20.52 18.24 19.31 17.17 15.15 13.47 kw 6.79 6.03 6.01 5.35 5.66 5.03 4.44 3.95 PI kw 2.54 2.66 2.94 3.25 MBH 18.13 16.11 15.67 13.93 14.25 12.67 12.87 11.44 kw 5.31 4.72 4.59 4.08 4.18 3.71 3.77 3.35 623 / 294 (Low) PI kw 2.33 2.54 2.73 3.08 MBH 19.56 18.97 17.93 17.39 16.31 15.82 13.24 12.85 kw 5.73 5.56 5.26 5.10 4.78 4.64 3.88 3.76 PI kw 2.42 2.61 2.80 3.19 MBH 21.30 18.94 18.88 16.78 17.77 15.80 13.94 12.39 kw 6.24 5.55 5.53 4.92 5.21 4.63 4.09 3.63 PI kw 2.47 2.59 2.86 3.16 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 12

System Performance Data Indoor TDF-G12S1N6 R - 410a / 50 Hz Outdoor TAC-G36D1N6 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 31.95 28.40 27.62 24.55 25.12 22.33 22.68 20.16 kw 9.36 8.32 8.09 7.20 7.36 6.54 6.65 5.91 1249 / 589 (High) PI kw 3.15 3.42 3.67 4.15 MBH 34.47 33.44 31.61 30.66 29.76 28.86 23.34 22.64 kw 10.10 9.80 9.26 8.99 8.72 8.46 6.84 6.64 PI kw 3.28 3.53 3.89 4.29 MBH 37.56 33.39 33.27 29.58 31.32 27.84 24.57 21.85 kw 11.01 9.79 9.75 8.67 9.18 8.16 7.20 6.40 PI kw 3.35 3.49 3.85 4.25 MBH 29.40 26.13 25.41 22.59 23.11 20.54 20.87 18.55 kw 8.62 7.66 7.45 6.62 6.77 6.02 6.12 5.44 1145 / 540 (Medium) PI kw 3.06 3.33 3.57 4.03 MBH 31.71 30.76 29.08 28.21 27.37 26.55 21.48 20.83 kw 9.29 9.02 8.52 8.27 8.02 7.78 6.29 6.11 PI kw 3.19 3.43 3.78 4.17 MBH 34.55 30.72 30.61 27.21 28.82 25.62 22.61 20.10 kw 10.13 9.00 8.97 7.98 8.45 7.51 6.63 5.89 PI kw 3.25 3.39 3.74 4.13 MBH 26.81 23.83 23.17 20.60 21.07 18.74 19.03 16.92 kw 7.86 6.98 6.79 6.04 6.18 5.49 5.58 4.96 1010 / 476 (Low) PI kw 2.98 3.23 3.47 3.92 MBH 28.92 28.06 26.52 25.73 24.97 24.22 19.59 19.00 kw 8.48 8.22 7.77 7.54 7.32 7.10 5.74 5.57 PI kw 3.10 3.33 3.67 4.06 MBH 31.51 28.01 27.92 24.82 26.28 23.36 20.62 18.33 kw 9.24 8.21 8.18 7.27 7.70 6.85 6.04 5.37 PI kw 3.16 3.30 3.64 4.02 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 13

System Performance Data Indoor TDF-G12S1N6 R - 410a / 50 Hz Outdoor TAC-G36D1N6 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 30.72 27.31 26.56 23.61 24.15 21.47 21.81 19.39 kw 9.00 8.00 7.78 6.92 7.08 6.29 6.39 5.68 1200 / 567 (High) PI kw 3.11 3.38 3.63 4.10 MBH 33.15 32.15 30.39 29.48 29.30 28.42 22.45 21.77 kw 9.71 9.42 8.91 8.64 8.59 8.33 6.58 6.38 PI kw 3.24 3.49 3.82 4.24 MBH 36.11 32.10 31.99 28.44 30.84 27.49 23.63 21.01 kw 10.58 9.41 9.38 8.34 9.04 8.06 6.92 6.16 PI kw 3.31 3.45 3.78 4.20 MBH 28.26 25.13 24.43 21.72 22.22 19.75 20.06 17.84 kw 8.28 7.36 7.16 6.37 6.51 5.79 5.88 5.23 1100 / 519 (Medium) PI kw 3.03 3.29 3.53 3.99 MBH 30.49 29.58 27.96 27.12 26.32 25.53 20.65 20.03 kw 8.94 8.67 8.20 7.95 7.71 7.48 6.05 5.87 PI kw 3.15 3.39 3.73 4.12 MBH 33.22 29.53 29.43 26.17 27.71 24.63 21.74 19.32 kw 9.74 8.66 8.63 7.67 8.12 7.22 6.37 5.66 PI kw 3.21 3.35 3.70 4.08 MBH 25.78 22.92 22.28 19.81 20.26 18.01 18.30 16.27 kw 7.55 6.72 6.53 5.81 5.94 5.28 5.36 4.77 971 / 458 (Low) PI kw 2.94 3.20 3.43 3.87 MBH 27.81 26.98 25.50 24.74 24.01 23.29 18.83 18.27 kw 8.15 7.91 7.47 7.25 7.04 6.82 5.52 5.35 PI kw 3.06 3.29 3.63 4.01 MBH 30.30 26.94 26.84 23.86 25.27 22.46 19.82 17.62 kw 8.88 7.89 7.87 6.99 7.41 6.58 5.81 5.17 PI kw 3.12 3.26 3.59 3.97 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 14

System Performance Data Indoor TDF-G14S1N6 R - 410a / 50 Hz Outdoor TAC-G42D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 36.54 32.48 31.58 28.08 28.72 25.54 25.94 23.06 kw 10.71 9.52 9.26 8.23 8.42 7.48 7.60 6.76 1447 / 683 (High) PI kw 3.68 4.00 4.29 4.85 MBH 39.42 38.24 36.15 35.06 34.03 33.01 26.70 25.90 kw 11.55 11.21 10.59 10.28 9.97 9.67 7.82 7.59 PI kw 3.83 4.12 4.54 5.02 MBH 42.95 38.18 38.05 33.83 35.82 31.84 28.10 24.98 kw 12.59 11.19 11.15 9.91 10.50 9.33 8.24 7.32 PI kw 3.91 4.08 4.50 4.97 MBH 33.62 29.88 29.06 25.83 26.43 23.49 23.86 21.21 kw 9.85 8.76 8.52 7.57 7.75 6.89 6.99 6.22 1384 / 653 (Medium) PI kw 3.58 3.89 4.17 4.71 MBH 36.27 35.18 33.26 32.26 31.31 30.37 24.56 23.82 kw 10.63 10.31 9.75 9.45 9.18 8.90 7.20 6.98 PI kw 3.73 4.01 4.41 4.88 MBH 39.51 35.13 35.01 31.12 32.95 29.30 25.85 22.98 kw 11.58 10.30 10.26 9.12 9.66 8.59 7.58 6.74 PI kw 3.80 3.97 4.37 4.83 MBH 30.66 27.26 26.50 23.56 24.10 21.43 21.76 19.35 kw 8.99 7.99 7.77 6.90 7.06 6.28 6.38 5.67 1339 / 632 (Low) PI kw 3.48 3.78 4.05 4.58 MBH 33.08 32.08 30.33 29.42 28.55 27.69 22.40 21.73 kw 9.69 9.40 8.89 8.62 8.37 8.12 6.56 6.37 PI kw 3.62 3.89 4.29 4.74 MBH 36.04 32.04 31.93 28.38 30.05 26.72 23.58 20.96 kw 10.56 9.39 9.36 8.32 8.81 7.83 6.91 6.14 PI kw 3.69 3.85 4.25 4.69 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 15

System Performance Data Indoor TDF-G14S1N6 R - 410a / 50 Hz Outdoor TAC-G42D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 35.13 31.23 30.37 27.00 27.62 24.55 24.94 22.17 kw 10.30 9.15 8.90 7.91 8.09 7.20 7.31 6.50 1384 / 653 (High) PI kw 3.64 3.95 4.24 4.79 MBH 37.91 36.77 34.76 33.72 33.43 32.43 25.67 24.90 kw 11.11 10.78 10.19 9.88 9.80 9.50 7.52 7.30 PI kw 3.79 4.07 4.36 4.96 MBH 41.30 36.71 36.59 32.53 35.19 31.43 27.02 24.02 kw 12.10 10.76 10.72 9.53 10.31 9.21 7.92 7.04 PI kw 3.86 4.03 4.32 4.91 MBH 32.32 28.74 27.94 24.84 25.41 22.59 22.94 20.40 kw 9.47 8.42 8.19 7.28 7.45 6.62 6.72 5.98 1320 / 623 (Medium) PI kw 3.54 3.84 4.12 4.66 MBH 34.87 33.83 31.98 31.02 30.10 29.20 23.62 22.91 kw 10.22 9.91 9.37 9.09 8.82 8.56 6.92 6.71 PI kw 3.68 3.96 4.36 4.82 MBH 37.99 33.78 33.66 29.92 31.69 28.17 24.86 22.10 kw 11.14 9.90 9.87 8.77 9.29 8.26 7.29 6.48 PI kw 3.75 3.92 4.32 4.77 MBH 29.48 26.21 25.48 22.65 23.17 20.60 20.93 18.60 kw 8.64 7.68 7.47 6.64 6.79 6.04 6.13 5.45 1275 / 602 (Low) PI kw 3.44 3.73 4.01 4.53 MBH 31.80 30.85 29.16 28.29 27.45 26.63 21.54 20.89 kw 9.32 9.04 8.55 8.29 8.05 7.80 6.31 6.12 PI kw 3.58 3.85 4.24 4.68 MBH 34.65 30.80 30.70 27.29 28.90 25.69 22.67 20.15 kw 10.16 9.03 9.00 8.00 8.47 7.53 6.64 5.91 PI kw 3.65 3.81 4.20 4.64 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 16

System Performance Data Indoor TDF-G16S1N6 R - 410a / 50 Hz Outdoor TAC-G48D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 40.88 36.34 35.33 31.41 32.14 28.57 29.02 25.80 kw 11.98 10.65 10.36 9.21 9.42 8.37 8.50 7.56 1671 / 789 (High) PI kw 4.29 4.66 5.00 5.65 MBH 44.10 42.78 40.44 39.23 38.07 36.93 29.87 28.97 kw 12.93 12.54 11.85 11.50 11.16 10.82 8.75 8.49 PI kw 4.47 4.80 5.29 5.85 MBH 48.05 42.72 42.57 37.85 40.07 35.63 31.44 27.95 kw 14.08 12.52 12.48 11.09 11.75 10.44 9.21 8.19 PI kw 4.56 4.75 5.24 5.79 MBH 37.61 33.44 32.51 28.90 29.57 26.28 26.70 23.73 kw 11.02 9.80 9.53 8.47 8.67 7.70 7.82 6.96 1601 / 756 (Medium) PI kw 4.17 4.53 4.86 5.49 MBH 40.58 39.36 37.21 36.09 35.02 33.97 27.48 26.65 kw 11.89 11.54 10.91 10.58 10.27 9.96 8.05 7.81 PI kw 4.34 4.67 5.14 5.68 MBH 44.21 39.30 39.17 34.82 36.87 32.78 28.92 25.71 kw 12.96 11.52 11.48 10.20 10.81 9.61 8.48 7.54 PI kw 4.43 4.62 5.09 5.63 MBH 34.30 30.49 29.65 26.36 26.96 23.97 24.35 21.65 kw 10.05 8.94 8.69 7.72 7.90 7.03 7.14 6.34 1551 / 732 (Low) PI kw 4.05 4.40 4.72 5.34 MBH 37.01 35.90 33.93 32.92 31.94 30.98 25.06 24.31 kw 10.85 10.52 9.95 9.65 9.36 9.08 7.34 7.12 PI kw 4.22 4.54 5.00 5.52 MBH 40.32 35.84 35.72 31.75 33.62 29.89 26.38 23.45 kw 11.82 10.50 10.47 9.31 9.85 8.76 7.73 6.87 PI kw 4.30 4.49 4.95 5.47 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 17

System Performance Data Indoor TDF-G16S1N6 R - 410a / 50 Hz Outdoor TAC-G48D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 39.31 34.94 33.98 30.20 30.90 27.47 27.90 24.81 kw 11.52 10.24 9.96 8.85 9.06 8.05 8.18 7.27 1599 / 755 (High) PI kw 4.24 4.60 4.94 5.43 MBH 44.31 42.98 38.89 37.72 38.15 37.01 28.72 27.86 kw 12.99 12.60 11.40 11.06 11.18 10.85 8.42 8.16 PI kw 4.41 4.74 4.97 5.61 MBH 48.27 41.07 40.93 36.39 40.16 34.87 30.23 26.87 kw 14.15 12.04 12.00 10.67 11.77 10.22 8.86 7.88 PI kw 4.50 4.70 4.92 5.56 MBH 36.16 32.15 31.26 27.79 28.43 25.27 25.67 22.82 kw 10.60 9.42 9.16 8.14 8.33 7.41 7.52 6.69 1529 / 722 (Medium) PI kw 4.12 4.47 4.80 5.43 MBH 39.01 37.84 35.77 34.70 33.68 32.67 26.42 25.63 kw 11.43 11.09 10.49 10.17 9.87 9.57 7.74 7.51 PI kw 4.29 4.61 5.08 5.61 MBH 42.51 37.79 37.66 33.48 35.45 31.52 27.81 24.72 kw 12.46 11.08 11.04 9.81 10.39 9.24 8.15 7.25 PI kw 4.38 4.57 5.03 5.56 MBH 32.98 29.32 28.51 25.34 25.93 23.05 23.41 20.81 kw 9.67 8.59 8.35 7.43 7.60 6.76 6.86 6.10 1479 / 698 (Low) PI kw 4.00 4.35 4.67 5.27 MBH 35.58 34.51 32.63 31.65 30.71 29.79 24.10 23.37 kw 10.43 10.12 9.56 9.28 9.00 8.73 7.06 6.85 PI kw 4.17 4.48 4.94 5.46 MBH 38.77 34.46 34.35 30.53 32.33 28.74 25.36 22.55 kw 11.36 10.10 10.07 8.95 9.48 8.42 7.43 6.61 PI kw 4.25 4.44 4.89 5.40 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 18

System Performance Data Indoor TDF-G20S1N6 R - 410a / 50 Hz Outdoor TAC-G60D1N5 ESP: 0.1" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 47.25 42.01 40.84 36.31 37.15 33.02 33.54 29.82 kw 13.85 12.31 11.97 10.64 10.89 9.68 9.83 8.74 1869 / 882 (High) PI kw 4.77 5.18 5.56 6.28 MBH 50.98 49.45 46.75 45.35 44.01 42.69 34.52 33.49 kw 14.94 14.49 13.70 13.29 12.90 12.51 10.12 9.82 PI kw 4.97 5.34 5.88 6.50 MBH 55.54 49.38 49.21 43.75 46.32 41.18 36.34 32.31 kw 16.28 14.47 14.42 12.82 13.58 12.07 10.65 9.47 PI kw 5.07 5.29 5.83 6.44 MBH 43.47 38.65 37.58 33.41 34.18 30.38 30.86 27.43 kw 12.74 11.33 11.01 9.79 10.02 8.90 9.04 8.04 1809 / 854 (Medium) PI kw 4.64 5.04 5.40 6.11 MBH 46.90 45.50 43.01 41.72 40.49 39.27 31.76 30.81 kw 13.75 13.33 12.61 12.23 11.87 11.51 9.31 9.03 PI kw 4.83 5.19 5.72 6.32 MBH 51.10 45.43 45.27 40.25 42.62 37.89 33.43 29.72 kw 14.98 13.31 13.27 11.80 12.49 11.10 9.80 8.71 PI kw 4.92 5.14 5.66 6.26 MBH 39.65 35.25 34.27 30.47 31.17 27.71 28.14 25.02 kw 11.62 10.33 10.04 8.93 9.13 8.12 8.25 7.33 1759 / 830 (Low) PI kw 4.51 4.90 5.25 5.94 MBH 42.77 41.49 39.22 38.05 36.92 35.82 28.97 28.10 kw 12.54 12.16 11.50 11.15 10.82 10.50 8.49 8.24 PI kw 4.69 5.05 5.56 6.14 MBH 46.60 41.43 41.29 36.71 38.87 34.55 30.49 27.11 kw 13.66 12.14 12.10 10.76 11.39 10.13 8.94 7.94 PI kw 4.79 5.00 5.50 6.08 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 19

System Performance Data Indoor TDF-G20S1N6 R - 410a / 50 Hz Outdoor TAC-G60D1N5 ESP: 0.2" Evaporator Airflow Rate CFM / LPS (Fan Speed) F (DB / WB) Cooling Capacity & Power Input Condenser Air Entering Temperature ( F) 95 105 115 125 T S T S T S T S MBH 45.44 40.39 39.27 34.91 35.72 31.75 32.25 28.67 kw 13.32 11.84 11.51 10.23 10.47 9.31 9.45 8.40 1799 / 849 (High) PI kw 4.71 5.12 5.49 6.21 MBH 49.02 47.55 44.95 43.60 42.97 41.68 33.20 32.20 kw 14.37 13.94 13.17 12.78 12.59 12.22 9.73 9.44 PI kw 4.91 5.28 5.56 6.42 MBH 53.41 47.48 47.32 42.06 45.23 40.17 34.94 31.07 kw 15.65 13.91 13.87 12.33 13.26 11.77 10.24 9.10 PI kw 5.01 5.22 5.50 6.36 MBH 41.80 37.16 36.13 32.12 32.86 29.21 29.67 26.38 kw 12.25 10.89 10.59 9.41 9.63 8.56 8.70 7.73 1739 / 821 (Medium) PI kw 4.58 4.98 5.34 6.03 MBH 45.10 43.75 41.36 40.11 38.93 37.76 30.54 29.62 kw 13.22 12.82 12.12 11.76 11.41 11.07 8.95 8.68 PI kw 4.77 5.13 5.65 6.24 MBH 49.13 43.68 43.53 38.70 40.98 36.43 32.15 28.58 kw 14.40 12.80 12.76 11.34 12.01 10.68 9.42 8.38 PI kw 4.87 5.08 5.60 6.18 MBH 38.12 33.89 32.95 29.29 29.97 26.64 27.06 24.06 kw 11.17 9.93 9.66 8.59 8.78 7.81 7.93 7.05 1689 / 797 (Low) PI kw 4.45 4.84 5.19 5.86 MBH 41.13 39.90 37.72 36.58 35.50 34.44 27.85 27.02 kw 12.05 11.69 11.05 10.72 10.41 10.09 8.16 7.92 PI kw 4.64 4.99 5.49 6.07 MBH 44.81 39.84 39.70 35.29 37.37 33.22 29.32 26.06 kw 13.13 11.68 11.64 10.34 10.95 9.74 8.59 7.64 PI kw 4.73 4.94 5.44 6.01 Notes: T S PI ESP - Evaporator Air Entering Temperature - Total Cooling Capacity - Sensible Cooling Capacity - Cooling Capacity - Total Power Input (Compressor + Condenser Motor + Evaporator Motor) - External Static Pressure 20

Fan Performance Data Imperial Fan Speed ESP Inches wg Airflow Rate (CFM) Indoor Model TDF Series: G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N6 0" 505 762 876 1285 1501 1730 1930 0.1" 490 740 851 1248 1447 1670 1870 High 0.2" 446 673 774 1201 1383 1601 1801 0.4" 1080 1310 1520 1720 0.5" 994 1247 1450 1650 0" 464 700 803 1178 1428 1650 1870 0.1" 450 680 780 1144 1383 1600 1810 Medium 0.2" 410 619 710 1100 1319 1530 1740 0.4" 990 1264 1470 1660 0.5" 911 1210 1410 1590 0" 412 618 706 1039 1383 1600 1820 0.1" 400 600 685 1009 1338 1550 1760 Low 0.2" 364 546 623 970 1274 1480 1690 0.4" 873 1219 1420 1610 0.5" 803 1165 1360 1540 Metric Fan Speed ESP Pascals (Pa) Airflow Rate (LPS) Indoor Model TDF Series: G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N6 0 238 359 413 607 709 817 911 25 231 348 401 589 683 788 883 High 50 210 317 365 567 653 755 850 100 510 618 718 812 125 469 588 685 779 0 219 330 303 556 674 779 883 25 212 320 367 540 653 755 854 Medium 50 193 291 335 519 623 722 821 100 467 598 694 784 125 430 571 666 751 0 194 291 333 490 653 755 859 25 188 283 324 475 631 732 831 Low 50 171 257 293 457 601 699 798 100 412 576 670 760 125 378 550 642 727 ESP CFM LPS - External Static Pressure - Cubic Feet per Minute - Litres per Second 21

Electrical Data Electrical Data For Indoor Units Indoor Model TDF Series: V / Ph / Hz G06S1N6 G08S1N6 G10S1N6 G12S1N6 G14S1N6 G16S1N6 G20S1N6 220-240 / 1 / 50 Operating Voltage Blower Motor Min 207 207 207 207 207 207 207 Max 253 253 253 253 253 253 253 HP 0.07 0.17 0.17 0.58 0.58 0.58 0.75 FLA 0.6 1.0 1.0 2.6 2.6 2.6 5.0 MCA Amps 0.8 1.3 1.3 1.3 3.3 3.3 6.3 MOCP Amps 5.0 5.0 5.0 5.0 5.0 5.0 10.0 Electrical Data For Outdoor Units Outdoor Model TAC Series: V / Ph / Hz G18D1N6 G24D1N6 G30D1N6 G36D1N6 G42D1N5 G48D1N5 G60D1N5 220-240 / 1 / 50 380-415 / 3 / 50 Operating Voltage Min 207 207 207 207 360 360 360 Max 253 253 253 253 440 440 440 RLA 6.85 9.20 15.00 18.60 6.90 8.60 9.50 Compressor LRA 42.0 55.0 67.0 100.0 52.0 51.5 67.1 Quantity 1 1 1 1 1 1 1 HP 0.07 0.07 0.27 0.07 0.07 0.33 0.33 Condenser FLA 0.44 0.44 1.80 0.44 0.44 2.00 2.00 Quantity 1 1 1 2 2 1 1 MCA Amps 9.0 11.9 20.6 24.1 9.5 12.8 13.9 MOCP Amps 16.0 21.0 36.0 42.0 16.0 21.0 23.0 Notes: FLA LRA RLA MCA MOCP - Full Load Amps - Locked Rotor Amps - Running Load Amps - Minimum Circuit Amps - Maximum Over Current Protection 22

Recommended Pipe Selection Liquid Line Pipe Selection (Outdoor unit above indoor unit) Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 25' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 33' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 50' 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 66' - - 3/8" 3/8" 3/8" 3/8" 1/2" 82' - - 3/8" 3/8" 3/8" 1/2" 1/2" 98' - - 3/8" 3/8" 3/8" 1/2" 1/2" 115' - - 3/8" 3/8" 3/8" 1/2" 1/2" 131' - - 3/8" 3/8" 3/8" 1/2" 1/2" Liquid Line Pipe Selection (Indoor unit above outdoor unit) Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 25' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 33' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 50' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 66' 1/4" 1/4" 3/8" 3/8" 3/8" 1/2" 1/2" 82' 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 98' 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 115' 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 131' 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" General Notes: a. Standard pipe size supplied by factory will be 16' (5m) b. Total equivalent length of piping should be limited to 131' (40 m) c. For rotary compressor the total equivalent length of piping is to be limited to 50' (15 m) d. For scroll compressor the total equivalent length of piping is to be limited to 131' (40 m) e. Additional Refrigerant Charge Liquid Line Size R410a Charge (grams / ft) 1/4" 10 3/8" 17 1/2" 24 23

Recommended Pipe Selection Suction Line Pipe selection Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D Pipe Size 16' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 25' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 33' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 50' 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 66' - - 5/8" 5/8" 3/4" 3/4" 7/8" 82' - - 5/8" 5/8" 3/4" 3/4" 7/8" 98' - - 5/8" 5/8" 3/4" 7/8" 7/8" 115' - - 3/4" 3/4" 3/4" 7/8" 7/8" 131' - - 3/4" 3/4" 7/8" 7/8" 7/8" Capacity Loss Multiplier Equivalent Pipe Length (feet) (Vertical + Horizontal) TDF-G06S TDF-G08S TDF-G10S TDF-G12S TDF-G14S TDF-G16S TDF-G20S TAC-G18D TAC-G24D TAC-G30D TAC-G36D TAC-G42D TAC-G48D TAC-G60D 16' 0 0 0 0 0 0 0 25' 0 0 0 0 0 0 0 33' 0.992 0.994 0.99 0.991 0.989 0.981 0.982 50' 0.984 0.982 0.982 0.988 0.982 0.979 0.978 66' 0.979 0.977 0.977 0.983 0.977 0.974 0.974 82' 0.974 0.972 0.972 0.978 0.972 0.969 0.971 98' 0.969 0.967 0.967 0.973 0.967 0.971 0.965 115' 0.964 0.963 0.972 0.978 0.963 0.969 0.961 131' 0.969 0.958 0.967 0.973 0.967 0.964 0.958 General Notes: a. Standard pipe size supplied by factory will be 16' (5m) b. For rotary compressor the total Equivalent length of piping is to be limited to 15 meters c. For Scroll compressor the total Equivalent length of piping is to be limited to 40 meters d. When the Outdoor unit is located above indoor unit, install a suction riser every 5 meters e. The capacity derating as per the performance chart applicable at various ambient temperatures f. The total length exceed more than 20 mts the following components to be installed at site g. Hard start kit (start capacitor and relay) must be installed on outdoor unit for single phase condensers h. Crankcase heater must be installed on compressors 24

Dimensional Drawings 25

26 Dimensional Drawings

Dimensional Drawings 27

28 Dimensional Drawings

Indoor Units Wiring Diagrams 29

Wiring Diagrams Outdoor Units 30

Outdoor Units Wiring Diagrams 31

Wiring Diagrams Outdoor Units 32

Outdoor Units Wiring Diagrams 33

Guide Specification General: Ducted Split Units shall be of high efficiency performance, being suitable for side and up flow installation on the roof or on the ground. Units shall be highly competent in performance and ideal for both commercial and residential application with whisper quiet operation. Units shall be designed to work up to 52 C (125.6 F) without tripping. Outdoor Unit: Outdoor units shall be designed and tested, conforming to AHRI Standards. Units shall be leak tested with electronic machines, piped, internally wired and fully charged with refrigerant R410a. Units shall be made from high quality, corrosion resistant galvanized steel casing and shall be powder coated for weather resistance and resilience. The galvanized steel sheets shall conform to ASTM-A525 and the powder coated panels shall be able to withstand 1000 hours as per ASTM-B117. Compressors shall be highly efficient rotary / fully hermetic scroll with standard controls and safety devices. Higher capacity compressors shall be provided with crankcase heaters which warm oil and keeps in check attenuation by refrigerant. High pressure and low pressure controls shall be provided for units above 36,000 Btu/hr. Internal thermal overload protection shall be available with the compressor. Condenser coils shall be constructed out of seamless inner grooved copper tube and aluminum corrugated fins mechanically bonded for maximum heat transfer. Coils shall be designed to have minimum pressure drop for refrigerant flow to induce the best output. Coils shall be factory pressure tested at 600 PSI. Condenser fans shall be propeller type, direct drive draw through vertical discharge with fan guard mounted to the panel. The outdoor units shall operate in electrical characteristics of 220-240 Volts / 50 Hz / 1Ø upto 36,000 Btu/hr and 380-415 Volts / 50Hz / 3Ø for capacities from 42,000 Btu/hr and above. 34

Guide Specification Indoor Unit: Indoor units shall comprise of evaporator coil, fan motor assembly, synthetic washable filter and metering device. Units shall have a compact design and a low profile suitable for horizontal Installation in most standard drop ceiling application thus providing flexibility in installation. The fans shall operate at three different speeds of Low, Medium and High. Fan type shall be double inlet double width (DIDW) and of ABS material. The motor provided shall be a single phase unit suitable for 220-240 Volts / 50 Hz. Unit shall be provided with factory assembled controls with a 220 240 Volts wired remote controller. Fan motor shall be internally thermal protected. Evaporator coil shall be constructed of seamless inner grooved copper tube and corrugated aluminum fins for high efficiency and durability. Units shall be constructed with an advanced refrigerant circuitry, offering minimum pressure drop and delivering the best possible output. The metering device shall be a flowrator / thermostatic expansion valve (TXV) Low density insulation provided in the units shall habilitate a quiet performance. The air compartment in the indoor unit shall be completely insulated with closed cell elastomeric insulation. All units shall be completely factory wired with single point power input provided with knockouts for utility, main power supply and control connections. The units shall be leak tested at 600 PSI by electronic machines, piped, internally wired and shall have a holding charge of refrigerant R410a. 35

Notes

Notes

Ref:TR/CAT/DSAC/16/02