OPERATOR S MANUAL. Cooling Unit LMK 1.3D/U. manufactured by: LAURI S.r.l. Via G. Di Capi, 11/A MANTOVA ITALY

Similar documents
BASIC 700 OPERATOR MANUAL

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

ENGLISH REMOTE CONTROL MANUAL

GUCHEN THERMO TRANSPORT REFRIGERATION UNITS INTRODUCTION

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

A/C-HEATER SYSTEM - MANUAL

KSD-35 DR11 KUE-35 DVN11

OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

USE AND MAINTENANCE MANUAL

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

Automotive Air Conditioning systems

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Refrigeration. User Instructions & Service History

Owner s Manual TABLE OF CONTENTS

Installation Manual Mopar Engine Compartment Upgrade Kit

HEATING AND AIR CONDITIONING

Heavy Duty Heater / Air Conditioner Model R-8545

R-2000 HEADLINER Air Conditioner Unit

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

SECTION 50 - CAB CLIMATE CONTROL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Operation Manual. AvantAC Classic Bus Air Conditioning Units. Carrier Transicold China


USER AND MAINTENANCE MANUAL

Owner's Manual TABLE OF CONTENTS

Thermostat Cold Air Evaporator

HEATING AND VENTILATION

Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Owner s Manual TABLE OF CONTENTS

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Owner s Manual Super-Slim Four-Way Cassette

YC ON-OFF SERIES. Service Manual

TECHNICAL DATA & SERVICE MANUAL

Split System, 18,000-48,000 Btu/h Underceiling Type MCC Series 50 Hz

REMOTE CONTROL MANUAL

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

USER'S MANUAL PGE Single Package Rooftop

OWNER S MANUAL VMH 09/12/18/24

40KMC KMQ

Harold Ag & Mobile Products

Service Step by Step Trouble-Shooting Check-List

Inverter Split-type Room Air Conditioner

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Owner's Manual TABLE OF CONTENTS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Part 3 Troubleshooting

V Series. Superior Temperature Control. Small trucks and vans

Operating Instructions Air Conditioner

442 Chapter 16. Figure 16-5 Gas leak detection

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 PRECAUTION... 2 PREPARATION... 4 FUNCTION DIAGNOSIS...

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

V-Series. Superior Temperature Control for Small Trucks and Vans

Operating Instructions Air Conditioner

Westinghouse. Split System Inverter Series. Service Manual

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

an ISO 9001:2015 Registered Company

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

INSTALLATION and OPERATION INSTRUCTIONS

MITSUBISHI AIR-CON SPARES TD43C/TD43D/TD60

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

RPI Industries, Inc.

Refrigerator IKE IKE IKE 229-6

PORTABLE AIR CONDITIONER (LOCAL)

Stainless Steel Counter Refrigerators Instruction manual

TECHNICAL DATA & SERVICE MANUAL

Installation Instructions

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

TCW 2000 Ice liner refrigerator and freezer PIJ

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

POLOCOOL USER MANUAL. For. PC-53AP/C 19,000 BTU(5.5kW) PC-44BP/C 15,000 BTU(4.4kW) PORTABLE REFRIGERATED AIR CONDITIONER

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

Installation, Operation, and Maintenance Information

CHILLERS. Operator s & Installation Manual

MINI SLIMLINE COOL VUY-A VUY-A

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

MODEL RD-8 Self Contained MODEL RD-2

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CHILLER. Operator s & Installation Manual

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Instructional & Operating Manual

Transcription:

OPERATOR S MANUAL Cooling Unit LMK 1.3D/U manufactured by: LAURI S.r.l. Via G. Di Capi, 11/A MANTOVA ITALY

IMPORTANT!!! The manufacturer does not accept responsibility for any action of the user, aimed to repair or simply to use the product covered by this guide, not in conformity to the instructions here enclosed. The manufacturer does not accept responsibility for damages to people or goods. 2

CONTENTS 1. INTRODUCTION 2. PRECAUTIONS 3. UNIT DESCRIPTION 4. UNIT OPERATION 5. TECHNICAL FEATURES 3

INTRODUCTION 1 Congratulations for your choice. To avoid troubles with your new cooling unit simply follow the directions of this manual. This manual must be intended as a support to a good use of your refrigeration unit but obviously it cannot help for all the cases of problems connected to the temperature controlled transports. Therefore, for your safety and for a longer operating life, we recommend to contact the nearest service point at any time. 4

PRECAUTIONS 2 Access the unit may involve certain risks. Any operation must be made by specialists. SUGGESTIONS: Take every safety measures before accessing the unit. When performing maintenance procedures on the refrigeration unit, make sure the unit is disconnected from the power source, the cab control is in OFF position and no automatic start-up are possible. Pay attention to the risks due to the presence of copper pipes with dangerous temperature gas circulation (positive or negative). Pay attention to the risks due to the presence of dangerous line voltage. Pay attention to the risks due to the presence of dangerous fans. Evaporator and condenser fans are protected by safety grills. Pay attention to the risks due to the danger involved by the sharp fins of the evaporator and condenser heat-exchangers. 5

UNIT DESCRIPTION 3 FRIGO LAMAR LMK 1.3E has been studied to equip small/medium delivery vehicles. The unit is manufactured as split-system to fit any kind of vehicle. This cooling unit is recommended when the customer has problems with the height of the vehicle as the condensing unit is fitted under the floor of the vehicle, in a safe position, and not on the roof. The unit can be driven by the vehicle engine during the daily use or by switching to standby during the parking time. LMK 1.3E D/U: unit working only driven by engine. LMK 1.3E DN/US: unit working driven by the vehicle engine and by switching to standby. 1. CIRCUIT DIAGRAM: 6

UNIT DESCRIPTION 3 2. DRAWING: Protection devices: Protection devices under described protect the parts of the unit LMK 1.3E. It s imprudent any action not executed by specialist personnel. FUSES: two 15A fuses protect the fans, they are located into the electrical equipment box; a 4A fuse protects the transformer, this fuse is located into the electrical equipment box; a 8A fuse protects the cabcontrol, this fuse is located into the cab-control box; general protection is guaranteed by a 30A fuse, this fuse is located near the battery of the vehicle. HIGH PRESSURE SWITCH: stops the working of the unit in case of elevation beyond the concurred limits of the cooling gas pressure (due to a malfunctioning of the fan of the condenser, as an example). It is located on the right side of the heating exchanger. LOW PRESSURE SWITCH: stops the working of the unit in case of lowering beyond the concurred limits of the cooling gas pressure (due to a leak in the gas circuit or to the gas filter, as an example). It is located close to the left electrical compressor. 7

7 6 f e D 4 3 UNIT OPERATION 4 Before starting the unit: Check the good condition and the belt tension of the engine driven compressor. Frequently get a look to the unit looking for leaks, loss of oil or gas, not working parts and whatever. Frequently make sure, at the end of the working day, to see water under the vehicle close to the drain hose. If you don t see water apply to your dealer to check for obstructions of the hose. The unit is controlled by the cab-control (fig. 2). The unit works by standby during the parking time or by the engine of the vehicle on road. The cab-control compounds a digital thermometer indicating the temperature inside the van, a thermostat to set the required value of temperature, a switch (3) to set the operating system: off (4), on road (1), standby (2):. V 1 1 0 1 9 es C pmo 8 t t es 5 TTELE FFO. ICE 1 2 (fig. 2) Use of the unit by the Cab-control: Start the vehicle engine; Set the switch (3) in VEIC position (1). The digital display (11) will blink for a few seconds, the necessary time for a quick diagnosis, then will show the temperature inside the van; Press the SET key (10) to check the temperature value previously set. To modify the temperature press the keys (5-6) located on the left of the box: the key on top (6) to increase the temperature, the key on bottom (5) to decrease the temperature. At the end of this procedure, after a few seconds, the display will show again the temperature inside the van. When the compressor is working the warning light (8) is on. When reached the required temperature the unit will stop. After an increasing of two degrees the unit will start again automatically; To shut-down the unit set the switch in OFF (4) position; The unit must be shut-down before connecting or disconnecting the standby supply cable; Check that the type of current corresponds to the one your unit requires; Connect the unit to the power network; Set the switch in ELETT (2) position. The defrosting system will start automatically (usually every 2/3 hours). During the defrosting time the digital display indicates DEF and the warning light (9) is on. You can start manually the defrosting by pressing for a few seconds the key (6). 8

A few suggestions: Check for abnormal noises when the unit is working. Pre-cool the van for 20/30 minutes before loading the goods. Evacuate the existing humidity by operating a manual defrost (this is possible only at proper temperatures). When loading check the temperature of the products to ensure they are at a proper temperature to be transported. The cooling unit has been engineered to maintain the temperature of pre-cooled products not to refrigerate warm goods. In order to enable a good air-flow circulation, around and through the load, pay attention to leave free space enough between the load and the box walls. If the cab-control does not switch on check the efficiency of the 8A fuse located on the back of the cab control box; If the unit does not work on road, check the efficiency of the 30A fuse located close to the battery of the vehicle; If the unit does not cool enough check the level of the refrigerant gas (2 kg of R134a), looking at the window located on the gas filter. If the compressor does not work on road check the efficiency of the 8A fuse located into the electrical equipment box (also check the standby supply cable is disconnected). If the condenser fan or the evaporator fan do not work check the efficiency of the 16A fuse located into the electrical equipment box (also check the standby supply cable is disconnected). THE UNIT STARTS UP AUTOMATICALLY. KEEP WELL AWAY FROM MOVING PARTS (BELTS, PULLEYS, FANS) FOR ANY PROBLEM DO NOT HESITATE TO CONTACT YOUR SERVICE CENTER 9

TECHNICAL FEATURES 5 Power supply: 220/240 V Max electrical current absorption: 20 A Refrigeration power at 0 C (ext. temp. = 30 C): 2029 W Refrigeration power at -10 C (ext. temp. = 30 C): 1307 W Refrigeration power at -20 C (ext. temp. = 30 C): 772 W Belt driver compressor: SANDEN SD 505 Electric compressor (2): ASPERA J6220ZX Condenser fan: 1 SPAL 190 mm (VA14-AP11/C34A) Evaporator fans: 1 GATE 250 mm (12V) Thermostatic valve: DANFOSS TEN 2 Refrigerant gas: R134a 10